Bids Are invited for Custom Bid For Services - Repair Maintenance And Operation Of Conventional Addressable Fire Alarm System With Auto Dialer Facility And Fire Fighting System At Sgrdji Airport Amritsar For 2026 To 2028 - Operation And Maintenance C
Tender Overview
Project Description
Bids Are invited for Custom Bid For Services - Repair Maintenance And Operation Of Conventional Addressable Fire Alarm System With Auto Dialer Facility And Fire Fighting System At Sgrdji Airport Amritsar For 2026 To 2028 - Operation And Maintenance Contract Of Fire Alarm & Detection System At New Terminal Building, Atc-Cum- Tech. Block, Cargo Complex, Aai/Bcas Offie Complex, Asr/Mssr & Smr Building, Dvor, Localizer, Glide Path, Ndb Comprising Of Control Panels, Repeater Panels, Manual Call Points, Detectors, Hootes, Mimic Panel, Pa System, Gsm/Landline Based Autodialer, Batteries Complete Circuit & Loop Wiring Etc. And Gas Suppression System At All Nav Aids Site I/C All Other Associated Accessories For Satisfactory Operation & Making The System Serviceable, Periodically Cleaning & Testing All The Associated Accessories Confirming To Oem Specification And Special Terms And Conditions Attending The Breakdown/ Faults, Preventive Maintenance, Ensuring Serviceablility / Satisfactory Working Condition Of The System, Maintenance Of Records / Documentation Etc. As Per The Detailed Specifications, Terms And Conditions Covered Under This Contract On All Days Including Sundays And Holidays Complete As Required.I) Skilled (I/C Reliever) = 04 No.Ii) Un- Skilled (I/C Reliever) = 04 No. , Operation And Maintenance Of Fire Hydrant And Sprinkler System On Around The Clock Basis With The Help Of Manpower As Specified For New Terminal Building , Atc Cum Technical Block, Aai/Bcas Office Complex, Air Cargo Complex ; Comprising Of Different Capacity Of Electric Pump Motor Sets, Diesel Engine Pump Sets, De-Watering Pumps, Butterfly/Sluice Valves, Pipe Line, Fire Hydrants, Sprinklers Etc. As Per Good Engineering Practice Complete In All Respect As Required And As Per Specification.I) Semi-Skilled (I/C Reliever) = 07 No.Ii) Un- Skilled (I/C Reliever) = 07 No. , Supervision For Operation And Maintenance Contract Of Complete Fire Alarm, Detection System, Gas Suppression System, Fire Hydrant And Sprinkler System As Per The Detailed Specifications, Terms And Conditions Covered Under This Contract On All Days Including Sundays And Holidays Complete As Required.I) Supervision (High Skilled) (W/O Reliever) = 01 No. , Replacement Of B Check Kit For The Following Capacity Diesel Engine I/C Replacement Of Multi Grade Oil As Required. , 118 Kw, Model - 6Sl9088t (Kirloskar Make) , Capacity 44.1 Kw/ 60 Hp , Model - 4R1040 Na (Kirloskar Make) , 68 Kw, Model - 6R1080 (Kirloskar Make) , Repairing, Servicing Sluice/ Butterfly Valves/ Nrv Etc. Of Different Sizes Provided In The Fire System At Various Locations Of Fire Hydrant And Sprinkler System As Required .(Item Will Be Executed Only If Required) , Repairing & Servicing Of Following Capacity Pump Sets After Dismantaling And Providing All Necessary Defective/Wornout Parts Such As Nut-Bolts, Rubber Gasket, Gland Dori, Rubber Coupling, Suitable Bearings Etc. And Re- Assembling The Pump, Making The Pump Set In Perfect Working Condition As Per Good Engineering Practice Complete In All Respect As Required At Site.(Item Will Be Executed Only If Required) , Jockey Pump Set , Sprinkler Pump Set , Hydrant Pump , Painting Of Fire Hydtant/ Sprinklar Pipeline Of Different Sizes Installed Inside/ Outside Of Terminal Building / Cargo Terminal With Two Or More Coats Of Painting With Synthetic Enamel Paint To Give An Even Shade, Including Cleaning Of Surface With Detergent Etc Of Approved Brand Or As Approved By Engineer-In-Charge As Required. , 40 Mm Dia , 80 Mm Dia , 100 Mm Dia , 150 Mm Dia. , 200 Mm Dia. , Supply And Fixing Of Fire Hydrant/ Sprinkler Ms Pipe Line To Bypass Leaking Underground Inaccessible Pipe Line Of Following Sizes Inside/Outside Of Terminal Building On Surface Including Cutting, Threading, Welding Etc. And Providing All Fittings E.G. Elbows, Reducers, Flanges, Gaskets, Nuts, Bolts And Washers Including Ms Fabricated Support Of Suitable Size For Ms Pipe Hanging On Wall With Ms Angle, Cl S, Hangers Etc. Including Painting Of Pipes And Fittings With Red Paint Over A Coat Of Ready Mixed Primer, Both Of Approved Quality And Shade Including Cutting Holes And Chases In Brick Or Rcc Walls/ Slabs And Making Good The Same Etc. Complete In All Respect As Required. , 100 Mm Dia Class C , 150 Mm Dia Class C , 200Mm Dia Class C , Supply And Laying Of Fire Hydrant/ Sprinkler Ms Pipe Line To Bypass Leaking Underground In Accessible Pipe Line Of Following Sizes Inside/Outside Of Terminal Building On Ground Including Cutting, Threading, Welding Etc. And Providing All Fittings E.G. Elbows, Reducers, Flanges, Gaskets, Nuts, Bolts And Washers Including Support Of Brick Work Upto A Height Of 600 Mm From Ground Surface Including Painting Of Pipes And Fittings With Red Paint Over A Coat Of Ready Mixed Primer, Both Of Approved Quality And Shade Etc. Complete In All Respect As Required. , 100 Mm Dia Class C , 200Mm Dia Class C , Replacement Of Existing Damaged Outdoor Type Hose Cabinet By Providing And Fixing The New Hose Cabinet ( 1.0 M X 0.55M X 0.85M) Made Of Not Less Than 3 Mm Aluminium Sheet Having Central Opening Glazed Door Including Necessary Locking Arrangement And Painting Work Including Also Providing M.S. Angles Mounting Frame Suitable For Accommodating External Hydrant Valve As Per Site Requirement. , Replacement Of The Damage Door Locks Of Internal / External Fire Hydrant Box. , Replacement Of The Damage Door Glass And Aluminium Frame Of Existing External Fire Hydrant Box. , Replacement Of Pressure Gauges With New 150/100 Mm Dial Pressure Gauges Including Required Modification And Fixing Of New 15 Mm Control Valve And Accessories As Required At Site. , Replacement Of Pressure Switches Including Required Modification, Electrical Connections, Fixing Of New 15 Mm Control Valve If Required And Accessories Etc., As Per Site Requirement. , Constructing Masonry Chamber 90X90x100 Cm Inside With 7.5 Class Designation Brick Work In Cement Mortar 1:4( 1 Cement: 4 Coarse Sand) For Butterfly/Sluice Valve With C.I. Surface Box 100 Mm Top Diameter,160 Mm Bottom Diameter And 180 Mm Deep (Inside) With Chained Lid And Rcc Top Slab 1:2:4 Mix(1Cement:2Coarse Sand: 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10( 1 Cement:5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3( 1 Cement : 3 Coarse Sand), 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design With Fps Bricks. , Providing And Fixing Of Cast Iron Butterfly Valves Of Following Size On The Existing M S Pipes, By Cutting, And Making Exact Gap On Pipe And Fixing Including Flanges, Gaskets ,Bolt ,Nut & Washers Etc. As Required:- , 200Mm Dia , 150Mm Dia , 100Mm Dia , 80Mm Dia , Providing And Fixing Of Cast Iron Ball Valves Of Following Size On The Existing M S Pipes, By Cutting, And Making Exact Gap On Pipe And Fixing Including Flanges, Gaskets, Bolt, Nut & Washers Etc. As Required:- , 25Mm Dia , 50Mm Dia , Providing And Fixing Of Gasket For Hydrants Etc. Complete Of Following Size. , 100Mm Dia , 150Mm Dia , 200Mm Dia , Providing And Fixing Of Inlet Rubber Ring Washer Etc. Complete As Required. , Service Visit Charge For Reprogramming Of Fire Alarm Panel Of Terminal Building. , Service Visit Charge For Reprogramming Of Fire Alarm Panel Of Bcas Building/ Cargo Building/ Mssr Radar Site. , Providing And Fixing Of Non-Return Valve (Dual Type Wafer Plate Nrv) Of Following Size Including Bolt, Nut, Washers And Rubber Gasket As Required:- , 200Mm Dia , 150Mm Dia , 100Mm Dia , 80Mm Dia , Providing And Fixing Of 150 Mm Dia C Class Ms Pipe With 4Mm Wrapping Coating As Per Is 1022 : 2008 As Required Complete In All Respect. , Providing And Laying C Class M.S. Pipe Of Following Size Including All Forged Fittings And Accessories Complete Including Welding, Jointing And Painting With One Coat Of Primer & Two Coats Of Post Office Red Enamel Paint Fixed, Including Chasing Of Walls/ Columns/Ceiling Etc. And Making Good The Same Complete As Required. , 150Mm Dia , 100Mm Dia , Providing And Fixing Of 150 Mm Dia Dummy Plate. , Supply Of Addressable Optical Smoke Detector. , Supply Of Conventional Optical Smoke Detector. , Supply Of Addressable Multi Detector. , Supply Of Addressable Heat Detector. , Supply Of Addressable Manual Call Point. , Supply Of Loop Driver Card Compatible With Existing Panel. , Supply Of 12 V, 130 Ah Sealed Maintenance Free Battery (Battery Make-As Per Aai Approved Make List)) , Supply Of 12 V, 150 Ah Sealed Maintenance Free Battery (Battery Make-As Per Aai Approved Make List) , Supply Of 12 Volt, 26 Ah Sealed Maintenance Free Battery For Fire Alarm Panels Of Terminal Buildings/Mssr. , Supply Of 12 Volt, 7 Ah Sealed Maintenance Free Battery For Fire Alarm Panels At Nav Aids , Supply Of Response Indicator. , Supply Of Control/ Monitor Module. , Supply Of 15 Mtr. Hose Pipe For Hydrant Point With Male Female Stainless Steel Adaptors. , Supply 63 Mm Dia Stainless Steel (Grade 304) Short Branch Pipe. , Supply Of Hydrant Cap 63Mm Dia , Supply Of Nozzle Ring (Ss) 63Mm Dia , Supply Of Hydrant Coupling (Ss) 63Mm Dia , Supply Of Nozzle Of Hose Reel 20Mm Dia , Supply Of Gland Dori (Heavy) For Main / Jockey Pump Motor , Supply Of Hydrant Wheel 63Mm Dia , Supply Of Coupling Lock (Small And Big) , Supply Of Electonic Hooter Cum Speaker , Supply Of Conventional 02 Zone Fire Alarm Panel For Nav Aids , Supply Of Auto Dialer For Addressable And Conventional Fire Alarm System , Dsr Items (%Rate Above Or Below)Complete Item Of Cpwd Schedule Rates Electrical 2025 Chapter 17 & 18.(For 10% Below Agency Will Quote 0.9 In Place Of 1 (Rate Column) & For 10% Above Agency Will Quote 1.1 In Place Of 1 (Rate Column)) (Including Labour Cess, Operation Area Charges & Gst).
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Operation and Maintenance Contract of Fire Alarm & Detection System at New Terminal Building, ATC-cum- Tech. Block, Cargo Complex, AAI/BCAS Offie Complex, ASR/MSSR & SMR Building, DVOR, Localizer, Glide Path, NDB comprising of control panels, repeater panels, Manual Call Points, Detectors, Hootes, Mimic Panel, PA System, GSM/Landline based Autodialer, Batteries complete circuit & loop wiring etc. and Gas Suppression system at all nav Aids site i/c all other associated accessories for satisfactory operation & making the system serviceable, periodically cleaning & testing all the associated accessories confirming to OEM specification and Special Terms and conditions attending the breakdown/ faults, preventive maintenance, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required.i) Skilled (I/c Reliever) = 04 No.ii) Un- Skilled (I/c Reliever) = 04 No. | Operation and Maintenance Contract of Fire Alarm & Detection System at New Terminal Building, ATC-cum- Tech. Block, Cargo Complex, AAI/BCAS Offie Complex, ASR/MSSR & SMR Building, DVOR, Localizer, Glide Path, NDB comprising of control panels, repeater panels, Manual Call Points, Detectors, Hootes, Mimic Panel, PA System, GSM/Landline based Autodialer, Batteries complete circuit & loop wiring etc. and Gas Suppression system at all nav Aids site i/c all other associated accessories for satisfactory operation & making the system serviceable, periodically cleaning & testing all the associated accessories confirming to OEM specification and Special Terms and conditions attending the breakdown/ faults, preventive maintenance, ensuring serviceablility / satisfactory working condition of the system, maintenance of records / documentation etc. as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required.i) Skilled (I/c Reliever) = 04 No.ii) Un- Skilled (I/c Reliever) = 04 No. |
| 2 | Operation and maintenance of Fire hydrant and sprinkler System on around the clock basis with the help of manpower as specified for New Terminal Building , ATC cum Technical Block, AAI/BCAS Office Complex, Air Cargo Complex ; comprising of different capacity of Electric pump motor sets, Diesel Engine Pump sets, De-watering pumps, Butterfly/sluice Valves, pipe line, Fire Hydrants, Sprinklers etc. as per good engineering practice complete in all respect as required and as per specification.i) Semi-skilled (I/c Reliever) = 07 No.ii) Un- Skilled (I/c Reliever) = 07 No. | Operation and maintenance of Fire hydrant and sprinkler System on around the clock basis with the help of manpower as specified for New Terminal Building , ATC cum Technical Block, AAI/BCAS Office Complex, Air Cargo Complex ; comprising of different capacity of Electric pump motor sets, Diesel Engine Pump sets, De-watering pumps, Butterfly/sluice Valves, pipe line, Fire Hydrants, Sprinklers etc. as per good engineering practice complete in all respect as required and as per specification.i) Semi-skilled (I/c Reliever) = 07 No.ii) Un- Skilled (I/c Reliever) = 07 No. |
| 3 | Supervision for Operation and Maintenance Contract of complete Fire Alarm, Detection System, Gas Suppression System, Fire hydrant and sprinkler System as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required.i) Supervision (High Skilled) (w/o Reliever) = 01 No. | Supervision for Operation and Maintenance Contract of complete Fire Alarm, Detection System, Gas Suppression System, Fire hydrant and sprinkler System as per the detailed specifications, terms and conditions covered under this contract on all days including Sundays and holidays complete as required.i) Supervision (High Skilled) (w/o Reliever) = 01 No. |
| 4 | Replacement of B Check Kit for the following capacity Diesel Engine i/c replacement of multi grade oil as required. | Replacement of B Check Kit for the following capacity Diesel Engine i/c replacement of multi grade oil as required. |
| 5 | 118 Kw, Model - 6SL9088T (Kirloskar make) | 118 Kw, Model - 6SL9088T (Kirloskar make) |
| 6 | Capacity 44.1 KW/ 60 HP , Model - 4R1040 NA (Kirloskar Make) | Capacity 44.1 KW/ 60 HP , Model - 4R1040 NA (Kirloskar Make) |
| 7 | 68 kw, Model - 6R1080 (Kirloskar Make) | 68 kw, Model - 6R1080 (Kirloskar Make) |
| 8 | Repairing, servicing sluice/ butterfly valves/ NRV etc. of different sizes provided in the fire system at various locations of fire hydrant and sprinkler system as required .(Item will be executed only if required) | Repairing, servicing sluice/ butterfly valves/ NRV etc. of different sizes provided in the fire system at various locations of fire hydrant and sprinkler system as required .(Item will be executed only if required) |
| 9 | Repairing & servicing of following capacity pump sets after dismantaling and providing all necessary defective/wornout parts such as nut-bolts, rubber gasket, gland dori, rubber coupling, suitable bearings etc. and re- assembling the pump, making the pump set in perfect working condition as per good engineering practice complete in all respect as required at site.(Item will be executed only if required) | Repairing & servicing of following capacity pump sets after dismantaling and providing all necessary defective/wornout parts such as nut-bolts, rubber gasket, gland dori, rubber coupling, suitable bearings etc. and re- assembling the pump, making the pump set in perfect working condition as per good engineering practice complete in all respect as required at site.(Item will be executed only if required) |
| 10 | Jockey Pump Set | Jockey Pump Set |
| 11 | Sprinkler Pump Set | Sprinkler Pump Set |
| 12 | Hydrant pump | Hydrant pump |
| 13 | Painting of Fire Hydtant/ Sprinklar pipeline of different sizes installed inside/ outside of terminal building / Cargo Terminal with two or more coats of painting with synthetic enamel paint to give an even shade, including cleaning of surface with detergent etc of approved brand or as approved by engineer-in-charge as required. | Painting of Fire Hydtant/ Sprinklar pipeline of different sizes installed inside/ outside of terminal building / Cargo Terminal with two or more coats of painting with synthetic enamel paint to give an even shade, including cleaning of surface with detergent etc of approved brand or as approved by engineer-in-charge as required. |
| 14 | 40 mm Dia | 40 mm Dia |
| 15 | 80 mm Dia | 80 mm Dia |
| 16 | 100 mm Dia | 100 mm Dia |
| 17 | 150 mm Dia. | 150 mm Dia. |
| 18 | 200 mm Dia. | 200 mm Dia. |
| 19 | Supply and fixing of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground inaccessible pipe line of following sizes inside/outside of terminal building on surface including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including MS Fabricated support of suitable size for MS Pipe hanging on wall with MS Angle, clamps, hangers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. | Supply and fixing of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground inaccessible pipe line of following sizes inside/outside of terminal building on surface including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including MS Fabricated support of suitable size for MS Pipe hanging on wall with MS Angle, clamps, hangers etc. including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade including cutting holes and chases in brick or RCC walls/ slabs and making good the same etc. complete in all respect as required. |
| 20 | 100 mm Dia Class 'C' | 100 mm Dia Class 'C' |
| 21 | 150 mm Dia Class 'C' | 150 mm Dia Class 'C' |
| 22 | 200mm Dia Class 'C' | 200mm Dia Class 'C' |
| 23 | Supply and laying of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground in accessible pipe line of following sizes inside/outside of terminal building on ground including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including support of brick work upto a height of 600 mm from ground surface including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade etc. complete in all respect as required. | Supply and laying of fire hydrant/ Sprinkler MS pipe line to bypass leaking underground in accessible pipe line of following sizes inside/outside of terminal building on ground including cutting, threading, welding etc. and providing all fittings e.g. elbows, reducers, flanges, gaskets, nuts, bolts and washers including support of brick work upto a height of 600 mm from ground surface including painting of pipes and fittings with red paint over a coat of ready mixed primer, both of approved quality and shade etc. complete in all respect as required. |
| 24 | 100 mm Dia Class 'C' | 100 mm Dia Class 'C' |
| 25 | 200mm Dia Class 'C' | 200mm Dia Class 'C' |
| 26 | Replacement of existing damaged outdoor type hose cabinet by providing and fixing the new hose cabinet ( 1.0 m x 0.55m x 0.85m) made of not less than 3 mm aluminium sheet having central opening glazed door including necessary locking arrangement and painting work including also providing M.S. angles mounting frame suitable for accommodating external hydrant valve as per site requirement. | Replacement of existing damaged outdoor type hose cabinet by providing and fixing the new hose cabinet ( 1.0 m x 0.55m x 0.85m) made of not less than 3 mm aluminium sheet having central opening glazed door including necessary locking arrangement and painting work including also providing M.S. angles mounting frame suitable for accommodating external hydrant valve as per site requirement. |
| 27 | Replacement of the damage door locks of Internal / External Fire Hydrant box. | Replacement of the damage door locks of Internal / External Fire Hydrant box. |
| 28 | Replacement of the damage door glass and aluminium frame of existing External Fire Hydrant box. | Replacement of the damage door glass and aluminium frame of existing External Fire Hydrant box. |
| 29 | Replacement of Pressure Gauges with new 150/100 mm dial Pressure Gauges including required modification and fixing of New 15 mm control valve and accessories as required at site. | Replacement of Pressure Gauges with new 150/100 mm dial Pressure Gauges including required modification and fixing of New 15 mm control valve and accessories as required at site. |
| 30 | Replacement of Pressure Switches including required modification, electrical connections, fixing of new 15 mm control valve if required and accessories etc., as per site requirement. | Replacement of Pressure Switches including required modification, electrical connections, fixing of new 15 mm control valve if required and accessories etc., as per site requirement. |
| 31 | Constructing masonry chamber 90x90x100 cm inside with 7.5 class designation brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for butterfly/sluice valve with C.I. surface box 100 mm top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix(1cement:2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement : 3 coarse sand), 12 mm thick, finished with a floating coat of neat cement complete as per standard design with FPS bricks. | Constructing masonry chamber 90x90x100 cm inside with 7.5 class designation brick work in cement mortar 1:4( 1 cement: 4 coarse sand) for butterfly/sluice valve with C.I. surface box 100 mm top diameter,160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix(1cement:2coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10( 1 cement:5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3( 1 cement : 3 coarse sand), 12 mm thick, finished with a floating coat of neat cement complete as per standard design with FPS bricks. |
| 32 | Providing and fixing of cast iron butterfly valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipe and fixing including flanges, gaskets ,bolt ,nut & washers etc. as required:- | Providing and fixing of cast iron butterfly valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipe and fixing including flanges, gaskets ,bolt ,nut & washers etc. as required:- |
| 33 | 200mm dia | 200mm dia |
| 34 | 150mm dia | 150mm dia |
| 35 | 100mm dia | 100mm dia |
| 36 | 80mm dia | 80mm dia |
| 37 | Providing and fixing of cast iron ball valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipe and fixing including flanges, gaskets, bolt, nut & washers etc. as required:- | Providing and fixing of cast iron ball valves of following size on the existing M S Pipes, by cutting, and making exact gap on pipe and fixing including flanges, gaskets, bolt, nut & washers etc. as required:- |
| 38 | 25mm dia | 25mm dia |
| 39 | 50mm dia | 50mm dia |
| 40 | Providing and fixing of Gasket for hydrants etc. complete of following size. | Providing and fixing of Gasket for hydrants etc. complete of following size. |
| 41 | 100mm dia | 100mm dia |
| 42 | 150mm dia | 150mm dia |
| 43 | 200mm dia | 200mm dia |
| 44 | Providing and fixing of Inlet rubber ring washer etc. complete as required. | Providing and fixing of Inlet rubber ring washer etc. complete as required. |
| 45 | Service visit charge for reprogramming of fire alarm panel of Terminal Building. | Service visit charge for reprogramming of fire alarm panel of Terminal Building. |
| 46 | Service visit charge for reprogramming of fire alarm panel of BCAS Building/ Cargo Building/ MSSR Radar site. | Service visit charge for reprogramming of fire alarm panel of BCAS Building/ Cargo Building/ MSSR Radar site. |
| 47 | Providing and fixing of Non-Return valve (dual type wafer plate NRV) of following size including bolt, nut, washers and rubber gasket as required:- | Providing and fixing of Non-Return valve (dual type wafer plate NRV) of following size including bolt, nut, washers and rubber gasket as required:- |
| 48 | 200mm dia | 200mm dia |
| 49 | 150mm dia | 150mm dia |
| 50 | 100mm dia | 100mm dia |
| 51 | 80mm dia | 80mm dia |
| 52 | Providing and fixing of 150 mm dia “C” class MS pipe with 4mm wrapping coating as per IS 1022 : 2008 as required complete in all respect. | Providing and fixing of 150 mm dia “C” class MS pipe with 4mm wrapping coating as per IS 1022 : 2008 as required complete in all respect. |
| 53 | Providing and laying ”C” class M.S. pipe of following size including all forged fittings and accessories complete including welding, jointing and painting with one coat of primer & two coats of post office red enamel paint fixed, including chasing of walls/ columns/ceiling etc. and making good the same complete as required. | Providing and laying ”C” class M.S. pipe of following size including all forged fittings and accessories complete including welding, jointing and painting with one coat of primer & two coats of post office red enamel paint fixed, including chasing of walls/ columns/ceiling etc. and making good the same complete as required. |
| 54 | 150mm dia | 150mm dia |
| 55 | 100mm dia | 100mm dia |
| 56 | Providing and Fixing of 150 mm dia Dummy Plate. | Providing and Fixing of 150 mm dia Dummy Plate. |
| 57 | Supply of addressable optical smoke detector. | Supply of addressable optical smoke detector. |
| 58 | Supply of conventional optical smoke detector. | Supply of conventional optical smoke detector. |
| 59 | Supply of addressable multi detector. | Supply of addressable multi detector. |
| 60 | Supply of addressable heat detector. | Supply of addressable heat detector. |
| 61 | Supply of addressable manual call point. | Supply of addressable manual call point. |
| 62 | Supply of loop driver card compatible with existing panel. | Supply of loop driver card compatible with existing panel. |
| 63 | Supply of 12 V, 130 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list)) | Supply of 12 V, 130 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list)) |
| 64 | Supply of 12 V, 150 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list) | Supply of 12 V, 150 AH sealed maintenance free Battery (Battery Make-as per AAI Approved Make list) |
| 65 | Supply of 12 volt, 26 AH sealed maintenance free battery for fire alarm panels of Terminal buildings/MSSR. | Supply of 12 volt, 26 AH sealed maintenance free battery for fire alarm panels of Terminal buildings/MSSR. |
| 66 | Supply of 12 volt, 7 AH sealed maintenance free battery for fire alarm panels at NAV AIDS | Supply of 12 volt, 7 AH sealed maintenance free battery for fire alarm panels at NAV AIDS |
| 67 | Supply of response indicator. | Supply of response indicator. |
| 68 | Supply of Control/ Monitor module. | Supply of Control/ Monitor module. |
| 69 | Supply of 15 mtr. Hose pipe for hydrant point with male female stainless steel adaptors. | Supply of 15 mtr. Hose pipe for hydrant point with male female stainless steel adaptors. |
| 70 | Supply 63 mm dia Stainless steel (Grade 304) short branch pipe. | Supply 63 mm dia Stainless steel (Grade 304) short branch pipe. |
| 71 | Supply of hydrant cap 63mm Dia | Supply of hydrant cap 63mm Dia |
| 72 | Supply of Nozzle ring (SS) 63mm Dia | Supply of Nozzle ring (SS) 63mm Dia |
| 73 | Supply of hydrant coupling (SS) 63mm Dia | Supply of hydrant coupling (SS) 63mm Dia |
| 74 | Supply of Nozzle of hose reel 20mm Dia | Supply of Nozzle of hose reel 20mm Dia |
| 75 | Supply of gland dori (heavy) for main / Jockey pump motor | Supply of gland dori (heavy) for main / Jockey pump motor |
| 76 | Supply of hydrant wheel 63mm Dia | Supply of hydrant wheel 63mm Dia |
| 77 | Supply of coupling lock (small and big) | Supply of coupling lock (small and big) |
| 78 | Supply of Electonic Hooter Cum Speaker | Supply of Electonic Hooter Cum Speaker |
| 79 | Supply of conventional 02 Zone Fire Alarm Panel for NAV AIDS | Supply of conventional 02 Zone Fire Alarm Panel for NAV AIDS |
| 80 | Supply of auto dialer for Addressable and Conventional Fire alarm system | Supply of auto dialer for Addressable and Conventional Fire alarm system |
| 81 | DSR Items (%rate above or below)Complete item of CPWD schedule rates electrical 2025 chapter 17 & 18.(For 10% below agency will quote 0.9 in place of 1 (rate column) & for 10% above agency will quote 1.1 in place of 1 (rate column)) (Including Labour Cess, Operation area charges & GST). | DSR Items (%rate above or below)Complete item of CPWD schedule rates electrical 2025 chapter 17 & 18.(For 10% below agency will quote 0.9 in place of 1 (rate column) & for 10% above agency will quote 1.1 in place of 1 (rate column)) (Including Labour Cess, Operation area charges & GST). |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender