Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; For The Upgradation Of Etp Installed In The Mill Committee As Per The Guidelines Of Cpcb Charter 2 0 Supply Of Flowmeters And Other M
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Industry Unit; For The Upgradation Of Etp Installed In The Mill Committee As Per The Guidelines Of Cpcb Charter 2 0 Supply Of Flowmeters And Other Materials As Per The F.. - Electromagnetic Water Flow Meterwith Plc & Iot/Telemetry Integration, Scada Mimic Display, Remote Display With Central Data Storage, Flow Management & Reporting Software, And All Mounting Hardware, Flanges Etc. Per Flowmetersize 2.0 With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal , Electromagnetic Water Flow Meterwith Plc & Iot/Telemetry Integration, Scada Mimic Display, Remote Display With Central Data Storage, Flow Management & Reporting Software, And All Mounting Hardware, Flanges Etc. Per Flowmetersize 3.0 With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal , Electromagnetic Water Flow Meterwith Plc & Iot/Telemetry Integration, Scada Mimic Display, Remote Display With Central Data Storage, Flow Management & Reporting Software, And All Mounting Hardware, Flanges Etc. Per Flowmetersize 4.0 With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal , Electromagnetic Water Flow Meterwith Plc & Iot/Telemetry Integration, Scada Mimic Display, Remote Display With Central Data Storage, Flow Management & Reporting Software, And All Mounting Hardware, Flanges Etc. Per Flowmetersize 6.0 With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal , Station Nodal Host Controllersupply Of Required Nodal Host Controller/Plc And One Local Hmi Panel Per Process Station (E.G. Etp, Boiler House, Boiling House) With Communication Cable And Flowmeter Power Cable With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal , Ultrasonic Open Channel Flow Meterfor Open Drain With V-Notch/Parshall Flume, With Iot/Telemetry Integration & Remote Display, With Central Management & Reporting Software , Computer System For Central Data Display & Scadaprocessor: Minimum Intel I3memory: Minimum 8 Gb;Storage: Minimum 256 Gb;Os: Window 10 & Abovewi-Fi & Lan Enabled, With Mouse, Keyboard & Ups With Errection Commissioning At Site And Communication With Upcb/Cpcb Portal
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 2.0” with errection commissioning at site and communication with UPCB/CPCB portal | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 2.0” with errection commissioning at site and communication with UPCB/CPCB portal |
| 2 | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 3.0” with errection commissioning at site and communication with UPCB/CPCB portal | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 3.0” with errection commissioning at site and communication with UPCB/CPCB portal |
| 3 | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 4.0” with errection commissioning at site and communication with UPCB/CPCB portal | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 4.0” with errection commissioning at site and communication with UPCB/CPCB portal |
| 4 | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 6.0” with errection commissioning at site and communication with UPCB/CPCB portal | Electromagnetic Water Flow Meterwith PLC & IoT/Telemetry Integration, SCADA mimic display, remote display with central data storage, Flow Management & Reporting Software, and all mounting hardware, flanges etc. per flowmetersize 6.0” with errection commissioning at site and communication with UPCB/CPCB portal |
| 5 | Station Nodal Host ControllerSupply of required nodal host controller/PLC and one local HMI panel per process station (e.g. ETP, Boiler House, Boiling House) with communication cable and flowmeter power cable with errection commissioning at site and communication with UPCB/CPCB portal | Station Nodal Host ControllerSupply of required nodal host controller/PLC and one local HMI panel per process station (e.g. ETP, Boiler House, Boiling House) with communication cable and flowmeter power cable with errection commissioning at site and communication with UPCB/CPCB portal |
| 6 | Ultrasonic Open Channel Flow Meterfor open drain with V-Notch/Parshall Flume, with IoT/Telemetry integration & remote display, with central management & reporting software | Ultrasonic Open Channel Flow Meterfor open drain with V-Notch/Parshall Flume, with IoT/Telemetry integration & remote display, with central management & reporting software |
| 7 | Computer System for Central Data Display & SCADAProcessor: minimum Intel i3Memory: minimum 8 GB;Storage: minimum 256 GB;OS: Window 10 & aboveWi-Fi & LAN enabled, with mouse, keyboard & UPS with errection commissioning at site and communication with UPCB/CPCB portal | Computer System for Central Data Display & SCADAProcessor: minimum Intel i3Memory: minimum 8 GB;Storage: minimum 256 GB;OS: Window 10 & aboveWi-Fi & LAN enabled, with mouse, keyboard & UPS with errection commissioning at site and communication with UPCB/CPCB portal |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender