Tender For Providing 1 No 1.5 Tr Airconditioner Units And Its Electrical Provisions To The Tmt Room Of Cardiology Department At Cath Lab Building In Kanniyakumari Govt. Medical College Hospital At Asaripallam In Kanniyakumari District..
Tender Overview
Project Description
Tender for Providing 1 No 1.5 Tr Airconditioner Units And Its Electrical Provisions To The Tmt Room Of Cardiology Department At Cath Lab Building In Kanniyakumari Govt. Medical College Hospital At Asaripallam In Kanniyakumari District..
BOQ
| Sl. No. | Item Description |
| 1 | Supply and Installation of 1.5 TR (4500 K.cal/Hr) ABS Plastic Split type Air conditioner conforming to IS 1391 (Part-2) 1992 with Amdt No. 1 to 2 fitted with rotary compressor operating on refrigerant R-32/non CFC suitable for wall mounting for operation on 230V, 50HZ single phase AC supply with star rating of 3 star as per BEE specification and capable of performing the functions of |
| 2 | CoolingDehumidifyingAir CirculatingFilteringThe installation works for the above split type AC units includes the following.1.Mounting/Fitting Indoor and outdoor units at their respective locations.2. Laying refrigerant pipeline of required length connecting not exceeding 3 metre distance and both units after drilling hole/holes in the wall if required.3. Insulating the suction pipe with expanded polyethylene foam 5mm tubing.4. Laying 15mm dia flexible PVC drain pipe to throw out the condensate water being formed within the indoor unit.5. Leakage testing the entire system unit.6. Charging refrigerant gas in the unit.7. Suitable electric wiring to be provided with 2.5 Sq.mm PVC insulated copper wire between indoor and outdoor units up to 6 Mtrs length and up to switch within 3 Meters of location of indoor unit up to switch within 3 Meters of location of indoor unit (Carrier/Voltas/ O General) (Blood Bank ) |
| 3 | Supply and Installation of 4KVA Electronic Automatic Voltage Stabilizer V-GUARD make VGS 500 Model with Input Voltage range of 170Volt- 270 Volt and Output Voltage range 200Volts to 240 Volts with High and Low Voltage cut off and 3 minutes time delay relay with demonstration. |
| 4 | Supply and fixing of MS stand to rest the Outdoor unit. |
| 5 | Supply and laying of 5/8\\" and 3/8\\" copper pipe (Extra beyond 3 metres supplied with AC unit) |
| 6 | Supply and fixing of water drain pipe line |
| 7 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire with painting of suitable colour. |
| 8 | Supply and fixing of 32 Amps DP MCB with sheet steel enclosure (Higher end) in flush with wall and making good of the concealed portion with earth connection. (The DP MCB & Enclosure should be of (Higher end) |
| 9 | GST Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender