Housing Urban and Rular Development Government Departments Closing in 0 days TDR #57807573

Tender For Renovation Of Jantanbari Electrical Inspection Dakbanglow/Sh: Providing Internal Electrification Thereof/ Sh:-Maintenance And Repairs Of electrical installation Thereof.

Issued by Government Departments · Gomati, Tripura
Tender Value
7.89 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
0 days left
EMD
15799
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gomati → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Renovation Of Jantanbari Electrical Inspection Dakbanglow/Sh: Providing Internal Electrification Thereof/ Sh:-Maintenance And Repairs Of electrical installation Thereof.

BOQ

Name of Work:- Renovation of Jantanbari Electrical Inspection Dakbanglow/SH: Providing Internal Electrification thereof/ SH:-Maintenance and repairs of E.I thereof.
Sl. No. Item Description
1Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
22 x 1.5 sq.mm:-
32 x 2.5 sq.mm:-
42 x 4 sq.mm:-
54 x 6 sq.mm:-
6Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/ surface including connection etc. as required.
71 x 1.5 sq.mm:-
82 x 4 sq.mm:-
94 x 6 sq.mm:-
10Earthing with Copper earth plate 600 mm x 600 mm x 3 mm thick i/c accessories and providing masonry enclosure with CI cover plate Size 12\\"x 12\\" having locking arrangement, along with 20 mm dia (medium gauge) watering pipe including CC work etc as required:-
11Extra for using salt (12 kg) and charcoal (96kg) for plate earth electrode as required.
12Proving and fixing / Drawing 4.06 mm dia (8 SWG) Copper wire on surface or in existing G.I / PVC / Polythene pipe for loop earthing as required.
13Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of 4.06mm (8SWG) dia G.I./ Copper wire for earth connection from earth electrodes etc as required.
14Supplying and fixing of following ratings MCB B/C curve having breaking capacity 10 KA in the existing MCB, DB including connection as reqd.
156 to 32 amps SP MCB:-
166 to 32 amps DP MCB:-
1740/50/63 amps TPN MCB:-
18Providing, fabrication and erecting of 7 mtr long(TATA/Jindal) medium gauge G.I Pole consisting of three distinct concentric sections: with base plate attachment of 300mmX300mmX10mm MS plate with necessary nuts and bolts of suitable length on base made of 1: 2: 4 c.c. work with net finishing connected with adjustable nuts & bolts suitable for injecting the pole with bottom section of 65 mm dia G.I Pole 2 mtr long medium gauge (TATA/Jindal) , middle section 50 mm dia G.I pipe of 3m long(TATA/Jindal)medium gauge and top section of 40mm G.I pipe 2m long(TATA/Jindal) medium gauge which will be firmly bended and fabricated to a suitable angle ,all the pipes jointed or welded properly with necessary joints/reducer sockets along with cable gland, with necessary black colour painting, and wiring with 3 core 1.5 sq.mm pvc insulated copper conductor etc as required
19Supplying and fixing of 3 phase Astronomical/Digital Street light panel of 6 KW Range, consisting of 32 A TP contactor , 40 A TPN MCB, Conforming to IS/IEC 60947-4-1 provided with Protection Degree of IP 54, Extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring ,In-built Short-Circuit Protection with Class H Insulation including necessary connection etc as required.
20Suppling, installation ,testing and commissioning of totally enclosed compartmentalized cubical electrical panel board double door type having size of (.40 x 0.40 x 0.30)mtr fabricated with standared MS angle (40 x40 x6)mm in size with 04 nos.70 cm long legs grouted on Base by c.c.work 2 mm thick (14 SWG) M.S. sheet painted with powder coating and necessary earth bars etc for installation of existing 32 Amps TPN MCB, 32A busbar chamber,and 02 nos 32A DP MCB well insulated etc with necessary insulators , cable etc i/c cable terminals and interconnections as required:
21Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement- 1:2:4 ( 1 Cement: 2 fine sand : 4 graded well burnt brick aggregate 20 mm nominal size):-
22Centering shuttering including struttings, propping etc.and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank:-
236 mm cement plaster in single layer including cost of materials required and finishing even and smooth and curing complete. In cement mortar 1 : 4 ( 1 cement : 4 fine sand ):-
24Neat cement punning:-
25Supplying and fixing of M.S Box size (12\\"x8\\"x6\\") made of 3 mm size MS sheet with an arrangement of fittingMCB SP and Neutral link i/c rubber Gasket to the cover, water outlet duct to the below and locking arrangement.
26Drawing of armoured/un-armoured cable with proper saddling etc as required:-
27Supplying & fixing of different sizes of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing outdoor light on wall /RCC base with necessary MS clamp, nut, bolt etc as required:-
2840 mm dia
29Supplying & fixing of 1200 mm sweep white color AC ceiling fan capacitor type double ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR) (ISI marked, BEE 1 star/minimum service value 4.0 m3/min/W) : -
30Supplying & fixing of 1200 mm sweep white color AC ceiling fan with brush less dirrect current (BLDC) motor having class B insulation, power factor not less than 0.9 complete with 300 mm down rod, canopies, shackle kit, 3nos blades, safety rope including wiring the down rod with 2x1.5 sqmm PVC insulated copper conductor cable(FR) (BEE 5 star/minimum service value 6.0 m3/min/W & tolerance as per IS:374-2019) : -
31Supplying & installation of 400 mm sweep AC wall mounting fan with plastic blade including connection etc as required:-
32Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:-
33Supplying of 400 mm sweep AC padestal fan with metal blade etc as required:-
34Supplying and fixing of following vertical storage water heater 5 star catagory complete with 15 amps top, connection pipes including necessary connection etc as required.
3510 litre storage capacity:-
36Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc. as required (with 50000 burning hours and minimum lumen output of 100 lm/watt):-
37Surface mounted box type batten suitable for single 18/20 watt integrated LED tube lamp (without lamp):-
38Recessed round/Square shaped 6 watt LED downlight with integral driver and high quality polycarbonate diffuser:-
39Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:-
4018/20 watt LED tube with integral driver and polycarbonate diffuser (50000 burning hours and minimum lumen output of 100lm/watt):-
41Supplying & installation of Astronomical timer Switch including necessary connection etc as required:-
42Supplying & installation of following power contactors including necessary connection etc as required:-
433 pole 18 amps (AC3) power contactors with 1NO+1NC Aux. Contact.
44Supplying, installation, testing and commissioning of following ratings Valve regulated lead acid(VRLA) battery with all accessories including necessary connections etc. as required:-
4512 V/ 180AH tall tubular/ flat plate Battery:-
46Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):-
4760 watt LED street light fixture with integral driver and secondary lens (IP 66):-
489 watt/10 watt LED Bollard light with high quality polycarbonate diffuser (IP 65):-
4940 watt LED post top light fixture with integral driver and high quality polycarbonate diffuser (IP 65):-
50Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
513core 4 Sq mm
524 core 6 Sq mm
53Excavation of earth for cable trench of 800mm depth & 300mm width in all kinds of soil including back filling of cable trench with the excavated soil with 20cm layer of sand, 3.5 nos bricks per metre for protection including ramming, consolidating to the original shape as per dirrection of Site Engineer :- Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57807573
AUTHORITY Government Departments
TENDER VALUE 7.89 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Renovation Of Jantanbari Electrical Inspection Dakbanglow/Sh: Providing Internal Electrification Thereof/ Sh:-Maintenance And Repairs Of electrical installation Thereof.
Basic Detail
Tender No EE-IED/UDP/11/2026-27
Bidding Type Tender
Location
City Gomati
State Tripura
Key Dates
Publish Date 30 Sep 2026
Submission Date 07 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 7.89 Lakhs
Tender Fee 1000
EMD 15799
Exemption Not Available
Document List
2bf5f1bb-aa5c-4696-86f6-a65a9396067d.html
BOQ_78738.xls
EDNIT.pdf
Tendernotice_1 (34).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

2bf5f1bb-aa5c-4696-86f6-a65a9396067d.html

xls

BOQ_78738.xls

pdf

EDNIT.pdf

pdf

Tendernotice_1 (34).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders