Home Affairs Statutory Bodies & Commissions/Committees Closing in 13 days TDR #57806792

Tender For Construction Of Multi Purpose Hall Against The Authorized Area Of Community Centre, Info And Recreation Centre, Darbar Shed & Drill Shed) At Tpt Bn, Itb Police, Chandigarh

Issued by Statutory Bodies & Commissions/Committees · Chandigarh, Chandigarh
Tender Value
5.07 Crore
Estimated cost
Bid Submission
22 Oct 2026
13 days left
EMD
10.15 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Multi Purpose Hall Against The Authorized Area Of Community Centre, Info And Recreation Centre, Darbar Shed & Drill Shed) At Tpt Bn, Itb Police, Chandigarh

BOQ

Name of Work:- Construction of Multi Purpose Hall Against the Authorized Area of Community Centre, info and Recreation Centre, Darbar Shed & Drill Shed) at TPT Bn, ITB Police, Chandigarh
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil
2Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
3Supplying and stacking at site. Good earth Earth upto 20 Km
4Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
5Supplying chemical emulsion in sealed containers including delivery as specified Chlorpyriphos / Lindane emulsifiable concentrate of 20%
6Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300 mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
7Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work upto plinth level. 1:4:8 (1 cement : 4 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 8 graded stone aggregate 40 mm nominal size Recycled Aggregate (RA))
9Providing and laying damp proof course 50 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
10Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
11Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
12Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed by dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth.
13Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M30 grade with minimum cement content of 350 kg /cum
14Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum
15Add for using extra cement in the items of design mix over and above the specified cement content therein.
16Centering and shuttering including strutting propping etc. and removal of form work for : Foundations, footings, bases of columns etc. for mass concrete.
17Suspended floors, roofs, landings, balconies and access platform.
18Lintels, beams, plinth beams, girders, bressumers and cantilevers.
19Columns, pillars, piers, abutments, posts and struts.
20Edges of slabs and breaks in floors and walls. Under 20 cm wide.
21Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore.
22Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D ormore
23Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
24Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
25Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
26Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
27Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
28Providing and fixing ISI marked flush door shutters conforming to IS 2202 (part I) decorativie type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked stainless steel butt hinges with necessary screws
29Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : With ISI marked stainless steel butt hinges of required size Second class teak wood
30Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
31Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady] the frame.
32Providing and fixing to existing door frames. 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge
33Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
34Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
35Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250 x 16 mm
36Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm
37Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 200x10 mm
38Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm
39Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 100 mm
40Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
41Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineerin-charge: Profile Fixing with adjustable lugs with split end tail toeach jamb
42Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. Using R3 series with frame (98 mm & above ) x (40 mm & above) & both glazed and fly screen sash (30mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed pannel along with multi-point locking system ( Height upto 1.8m)
43Fixed window / ventilator without mullion / transom Using R3 series with frame (55mm & above) x (45mm & above). ( Height upto 2.5m)
44Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
45Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 8 mm thickness
46Filling the gap in between aluminium frame & adjacent RCC / Brick / Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge. Upto 5 mm depth and 5 mm width
47Providing and fixing hard drawn steel wire fabric of size 75 x25 mm mesh or other suitable size wire mesh to be fixed & firmly anchored to the concrete surface by means of “L” shaped mild steel shear key welded with existing reinforcement including the cost of materials, labour, tool & plants as approved by Engineer-in-charge.
48Cement Plaster (In Fine & Coarse Sand) 15 mm cement plaster of mix : 1:6 (1 cement : 6 coarse sand)
49Cement Plaster (In Fine & Coarse Sand) 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
50Cement Plaster (In Fine & Coarse Sand) 6 mm cement plaster of mix. 1:3 (1 cement : 3 fine sand)
51Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof.
52Neat cement punning
53Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
54Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats
55Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
56Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
57Melamine polishing on wood work (one or more coat).
58Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sq.m.
59Extra for providing edge moulding to 18 mm thick marble stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Granite work
60Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
61Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size Size of Tile 800 x 1600 mm
62Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick
63Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
64Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
65Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
66Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mm
67Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm diameter
68Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.Coupler 75 mm
69Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend
70Providing and fixing on wall face unplasticised- PVC moulded fittings / accessories for unplasticised rigid PVC rain water pipes conforming to IS : 13592 type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Shoe (Plain) 75 mm
71Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs screwed with MS screws of required length including cuting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 75 mm
72Providing and fixing to the inlet mouth of rain water pipes cast iron grating 15 cm diametre and weighing not less than 440 grams.
73Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
74Making khurras 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge and making and finishing the outlet complete.
75Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
76Finishing walls with textured exterior paint of required shade : New Work (Two or more coats applied @ 3.28 ltr/ 10 Sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
77Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
78Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required : 1.00 mm thick with zinc coating not less than 275 gm/m²
79Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet andbitumen washers complete.0.80 mm thick with zinc coating not less than 275 gm/m²
80Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S.sheet gutter with iron brackets 40x3 mm size, bolts, nuts and washers etc.,including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m²
81Extra for providing and fixing wind ties of 40x 6 mm flat iron section. metre 195.60
82Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
8325 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood
84Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
85Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
86Providing and fixing Health Faucet With Tube 1 Meter & Hook, S. Steel 304 fixed to wall with rawl plugs screws complete. (Make: Euronics : Model. No. EHF-10)
87Providing and fixing CP brass Two way cock with wall flange (Make: Euronics : Model. No. FLO-3004A)
88Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
89Half threaded waste coupling. (Make:Euronics Model No. EWC02-CP-32mm)
90Wall Mounted Kitchen Sink Mixer with swivel spout (Make: Euronics Model. No. FLO-3012A)
91Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 40 mm dia
92Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
93Providing and fixing Minimum 8mm thick bevelled edge Mirror covering full wall width (from 1st wash basin to last wash basin) of height 800mm over wooden backdrop of approved design.
94Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
95Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineerin- charge.
96Providing and fixing toilet paper holder : C.P. brass
97Providing and fixing MS holder bat clamps of approved design to sand cast iron/cast iron spun pipe embedded in and including cement concreteblocks 10x10x10cm of 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) including cost of cutting holes & making good the walls. etc. 100mm dia pipe
98Cutting chases in brick mansonry walls for following diameter sand cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.5mm nominal size), incliding necessary plaster and pointing in cement mortal 1:4 (1 cement :4 coarse sand): 100mm dia
99Cutting chases in brick mansonry walls for following diameter sand cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.5mm nominal size), incliding necessary plaster and pointing in cement mortal 1:4 (1 cement :4 coarse sand): 75mm dia
100Cutting chases in brick mansonry walls for following diameter sand cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.5mm nominal size), incliding necessary plaster and pointing in cement mortal 1:4 (1 cement :4 coarse sand): 50mm dia
101Providing and fixing C.P.brass long body bib cock of approved quality conforming to IS standard and Weighing not less than 690 gms. 15 mm nominal bore.
102Providing and Fixing 450mm\\" long C.P. brass towel rail with C.P. brass brackets fixed to raw plugs fixed with C.P. brass screws complete including cutting and making good the walls wherever required. (Make: Cera Cat. No.5013104CH)
103Providing and fixing Soap Dish -Ss304, Chrome Plated fixed in position by rawl plugs and CP brass screws. (Make: Euronics Model No. ACC01 or equivalent)
104Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in-charge.
105Providing and fixing wall mounted recess hand dryer complete including fixing on wall with PVC rawl plug and CP brass screw complete. (Make: Euronics Model - RHD2)
106Providing Fixing CP brass shower set comprising of CP brass single lever Shower mixe with spout, shower arm, shower rose complete including cutting and making good the wall etc. Shower mixer with spout (Make:Jaquar Cat. No. COP-273NPM or equivalent)
107Providing Fixing CP brass shower set comprising of CP brass single lever Shower mixe with spout, shower arm, shower rose complete including cutting and making good the wall etc. CP brass shower arm (Make:Jaquar No.SHA-CHR-477 or equivalent)
108Providing Fixing CP brass shower set comprising of CP brass single lever Shower mixe with spout, shower arm, shower rose complete including cutting and making good the wall etc. CP brass shower head & rose (Make: Jaquar Cat. No. OHS-CH R-1661 or equivalent)
109Providing and fixing Soap Dispenser (S. Steel ) complete including fixing on wall with screw complete. (Make: Euronics Model -ES04)
110Providing & fixing, testing and commissioning of storage type electric water heater with automatic thermostatic control electric element, pressure release valve, brackets fixed to expansion fasteners with M.S. nuts and bolts all complete including cutting and making good the walls wherever required. Racold model no 4009009/approved equal. 25 litres capacity (2kw)
111Providing and fixing 100% stainless steel grating with frame of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works. 127 mm dia (Make: Chilly Cat. No. SKS05)
112Providing and fixing 100% stainless steel grating with frame of approved make and quality grade 304 on top of floor trap. The rate includes the cost of all ancillary works and material as required to complete the works. 101 mm dia (Make: Chilly Cat. No. SKS04)
113Providing and fixing soil, waste and vent pipes : 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
114Providing and fixing soil, waste and vent pipes : 75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
115Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100mm dia Hubless centrifugally cast(spun iron) pipes epoxy coated inside & outside is 15905
116Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 75mm dia Hubless centrifugally cast(spun iron) pipes epoxy coated inside & outside is 15905
117Providing and fixing plain bend of required degree. 100 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
118Providing and fixing plain bend of required degree. 75 mm dia Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905
119Providing and fixing single equal plain junction of required degree. 100x100x100 mm Hubless centrifugally cast(spun iron) pipes epoxy coated inside & outside is 15905
120Providing and fixing single equal plain junction of required degree. 75x75x75 mm Hubless centrifugally cast(spun iron) pipes epoxy coated inside & outside is 15905
121Providing and fixing terminal guard. 100mm dia Hubless centrifugally cast(spun iron) pipes epoxy coated inside & outside is 15905
122Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 100 mm dia SS 304 grade coupling with EPDM rubber gasket
123Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe 75 mm dia SS 304 grade coupling with EPDM rubber gasket
124Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905
125Painting sand cast iron/centrifugally cast iron(spun) soil,waste vent pipes and fittings with two coats of synthetic enamel paintof any colour such as chocolate rey or buff etc. over a coat of primer (of approved quality) for new work. 100 mm diameter pipe
126Painting sand cast iron/centrifugally cast iron(spun) soil,waste vent pipes and fittings with two coats of synthetic enamel paintof any colour such as chocolate rey or buff etc. over a coat of primer (of approved quality) for new work. 75 mm diameter pipe
127Providing and fixing GI pipes complete with GI fittings including trenching & refilling etc. 32mm dia nominal bore
128Providing and fixing GI pipes complete with GI fittings including trenching & refilling etc. 40mm dia nominal bore
129Providing and fixing GI pipes complete with GI fittings including trenching & refilling etc. 50mm dia nominal bore
130Painting GI pipes & GI fittings with two coats of anti bitumastic paint of approved quality. 32mm dia nominal bore
131Painting GI pipes & GI fittings with two coats of anti bitumastic paint of approved quality. 40mm dia nominal bore
132Painting GI pipes & GI fittings with two coats of anti bitumastic paint of approved quality. 50mm dia nominal bore
133Providing & fixing below counter installation type Drinking Water R.O. unit with micron filtration pre-treatment unit, skid mounted R.O. module with pressure pump and pressure tank, 6 m long food grade PP permeate line including connection to drinking water cooler, Coffee machine, complete in all respects. Permeate 20 ltr/hr. For supply, installation, testing & commissioning of sanitary fixtures as per above details.
134Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diametre
135Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
136Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm
137Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
138Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110mm Shoe
139Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm
140Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams.
141Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
142Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm dia nominal bore
143Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 20 mm dia nominal bore
144Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25 mm dia nominal bore
145Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 32 mm dia nominal bore
146Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 40 mm dia nominal bore
147Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 50 mm dia nominal bore
148Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 15 mm dia nominal bore
149Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore
150Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 20 mm dia nominal bore
151Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm dia nominal bore
152Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm dia nominal bore
153Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm dia nominal bore
154Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm dia nominal bore
155Providing and fixing ball valve(brass) of approved quality.High or low pressure with plastic floats complete : 25 mm dia nominal bore
156Painting GI pipes & fittings with synthetic enamel white paint wth two coats over a ready mixed priming coat both of approved quality for new work : 20 mm dia nominal bore
157Painting GI pipes & fittings with synthetic enamel white paint wth two coats over a ready mixed priming coat both of approved quality for new work : 25 mm dia nominal bore
158Painting GI pipes & fittings with synthetic enamel white paint wth two coats over a ready mixed priming coat both of approved quality for new work : 32 mm dia nominal bore
159Painting GI pipes & fittings with synthetic enamel white paint wth two coats over a ready mixed priming coat both of approved quality for new work : 40 mm dia nominal bore
160Painting GI pipes & fittings with synthetic enamel white paint wth two coats over a ready mixed priming coat both of approved quality for new work : 50 mm dia nominal bore
161Providing & placing on terrace (at all floor levels) polyethylene water storage tank IS 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet & overflow pipes but without fittings and the base support for tank.
162Excavating trenches by mechinical / manual masns of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All Kind of Soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia.
163Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm dia. R.C.C. pipe
164Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia. R.C.C. pipe
165Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of R.C.C. pipes including bed concrete as per standard design : 150 mm dia. R.C.C. pipe
166Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of R.C.C. pipes including bed concrete as per standard design : 250 mm dia. R.C.C. pipe
167Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
168Extra for depth for manholes : Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
169Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with SFRC cover and frame (heavy duty, HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
170Extra depth for circular type manhole 0.91m internal dia (at bottom) beyond 0.91 m to 1.67 m With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
171Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacture's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design.
172Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.50 mm dia niminal bore
173Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm dia niminal bore
174Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
175Wiring for light point / fan point /exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC Conduit, with modular switch,modular plate ,suitable GI Box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
176Wiring for group controlled (looped) light point / fan point /exhaust fan point/ call bell point (without independent switch) with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed PVC Conduit,and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
177Wiring for light /power plug with 2x4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface /recessed PVC conduit along with 1 No 4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
178Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 2x1.5 sq.mm + 1x1.5 sq.mm earth wire
179Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire
180Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 2 x 4 sq.mm + 1 x 4 sq.mm earth wire
181Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 2x6 sq.mm + 1x6 sq.mm earth wire
182Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 4x10 sq.mm + 2x6 sq.mm earth wire.
183Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed medium class PVC Conduit as required. 4x16 sq.mm + 2x6 sq.mm earth wire.
184Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch ,connection etc as required.
185Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 15/16 and 5/6 amps modular socket outlet and 15/16 amps modular switch connections, etc as required.
186Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
187Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm
188Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing of 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections painting etc. as required.
189Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator)8 way (2+8), Double door
190Supplying & fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 4 way (4+12) Double door
191Supplying & fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 6 way (4+18) Double door
192Supplying & fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) 8 way (4+24) Double door
193Supplying & fixing 5 amps to 32 amps rating.240/415 volts.10kA, 'C' curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing & commisioning etc.as required Single pole
194Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
195Supplying & fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
196Supplying & fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
197SITC of cubical type sheet steel clad IP52, wall / floor mounted totally enclosed LT switch board suitable or use on 415 V 3 phase 4 wire 50 cycles complete housed with incoming and outgoing bus bars including interconnection accessories with cable glands etc complete as required and with following incoming and outgoing switchgear as per specs and drawings. MAIN PANEL INCOMER 1 No. 200A, 4P MCCB (16KA) Each Incomer Metering & Protection. 1 Set of Multifunction meter (96x96mm) for V/A/PF/Hz/KVAH/KWH with LCD/LED Display as per IS 14697 3 Nos. 200/5A ratio CTs 15 VA class 5P 10 3 Nos. phase indicating lights with control fuses. 1 Set of control fuses & control terminals. 3 Nos. breaker ON/OFF/TRIP indication lamp with SP MCB. Bus Bar 250 Amp TPN Aluminium bus bar with heat shrinkable coloured insulated PVC sleeves having a current density of not less than 1.0 Amp sq.mm. and the neutral bus of 50% capacity interconnections between bus bars and breakers shall be through solid strip. Outgoings 63A 4P MCB 10KA - 04 Nos. 40A 4P MCB 10KA - 02 Nos. 40A DP MCB 10KA - 03 Nos.
198SITC of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser & construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 8- 10W LED Downlghter (Round)
199SITC of LED Recessed/ surface Down lighter (Round/square/ Rectangular) SMD type of following bodymaterial with PMMA and prismatic diffuser & construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 12- 15W LED Downlghter (Round)
200SITC of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36W 2x2 Panel
201SITC of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electricalcircuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 18-22 Watt LED Batten
202SITC of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).70 Watt
203SITC of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 100 Watt
204SITC of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conducto 1200mm, service value >_ 6.0 CM/Min/Watt, air delivery 210 CM/Min
205Supplying of 300 mm 900 RPM exhaust fan complete with louver and bird guard screen with 3 core flexible wire as required.
206Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
207ITC of pre-wired, fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required.
208Installtion of exhasut fan in the existing opening, including making good the damage, connection testiing and commissioning etc as requried Upto 450mm sweep
209Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
210Supply and Fixing of 400mm 240V, 1 phase Wall Fans oscillating type with in built fan regulator complete with all accessories with connection with three core copper wire of suitable size complete as required.
211Supplying and fixing of following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module 75 mm x 75 mm
212Supplying and drawing following pair, 0.5.mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
213Supplying and fixing following modular switch/ socket on the existing modular plate and switch box including connections but excluding plate etc .as required. Telephone socket outlet
214Supplying and fixing of the following sheet steel clad wall / recess mounting telephone tag blocks of krone make constructed from 14 SWG sheet steel finished with red oxide coating of two coats of paint with hinged gasketted powder coated door and complete. 05 pairs
215Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
216Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required
217Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. 1 Run of cable
218Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Copper Patch Cords of length 1m (3ft)
219Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required 9 U Rack
220Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance withANSI/TIA-568.2-D etc. complete as required. 24 Port
221SITC of sector panel suitable for following zones, complete with visula indication for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area / zone covered, complete with all connections interconnections as required. 4 Zone
222Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required
223SITC of manual call box of MS construction in surface / recess with stainless steel chain and hammer assembly complete with glass and oush button etc. as required.
224SITC of fire alarm sounder with facility to make announcements mounted in MS box (16 SWG) with hinged cover plate and suitable for operation with amplifier i/c line matching transformer etc. complete as required.
225Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
226Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charoal or coke and salt as required.
227Providing & fixing 25mm x 5mm GI Strip in 40mm dia GI pipe from earth elecrode including connections with GI nut, bolt, spring, washer excavation and re-fiiling etc. as required.
228Providing & fixing 25mm x 5mm GI Strip on surface / recess for connections as required.
229Providing & fixing of 6 SWG dia G.I wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required.
230Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 50 mm dia.
231Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80mm dia
232Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 100mm dia
233Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges ,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 150mm dia
234Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 100 mm dia
235Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts,washers etc.as required : 150 mm dia
236Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore.
237Providing & placing on terrace (at all floor levels) polyethylene water storage tank IS 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet,outlet & overflow pipes but without fittings and the base support for tank.
238Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia.
239Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 100 mm dia. 150 mm dia.
240Providing and fixing dial type pressure gauge with isolation cock and copper pipe at hydrant station. Dial diameter 100 mm calibration 0-15 kg/ sq.cm.
241Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100mm dia
242Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
243Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Gunmetal
244Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30m
245Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal
246Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun Metal
247Providing and fixing door with frame for all internal fire hydrants fabricated from 20x20x3 mm and 40x20x3 mm aluminium hollow box sections mounted with 3 no. of 100 mm Aluminium butt hinge on Aluminium angle frame of 45x45x5 mm size with hold fasts fixed to wall with P.C.C. (1:2:4) blocks 100x100x100 mm including 2 nos allen key lock for locking along with padlock arrangement & fully glazed with 4 mm thick float glass approved by local Fire Authority, powder coated fire red finish with \\" fire hose' written on front suitable to house 15 mm long two length of canvas hose with couplings, one no of branch pipe, one fire mans axe and two numbers of portable extinguishers, first aid fire hose and supports for hoses, branch pipes, Axe and hose reel. Size 2100x 900 mm complete as per approved design including necessary fixing arrangement for hoses & axe and branch pipe.)
248Providing and fixing gunmetal fire brigade inlet head as per IS:904 Specification tested for 20 Kg/cm2 with 63 mm dia. instantaneous type inlet and 100/150mm dia.. flanged outlet with built-in check valve for fire brigade connection to under ground tanks and fire risers including companion flanges as portable \\" E\\" including nuts, bolts & washers etc. Three way
249Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawl plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked.( Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.)
250Providing and fixing water Co2(ISI marked) extinguishers including all accessories as per IS specification with wall bracket with rawl plug Capacity 6 liters.(IS:15683)
251Providing and fixing ISI Marked of approved make Fire Extinguishers complete with all accessories as per manufacturer's specifications. ABC dry powder stored pressure type 6 kg capacity (IS:15683).
252Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type,fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable door, dust and vermin proof, powder coated of approved shade after 7 tank treatment process,cable alley ,interconnection with suitable size copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump and diesel pump set complete as per CPWD specification with following in coming and outgoings, suitable for operation on 415V,3 phase,50Hz Ac supply with enclosure protection class IP 42 as required: 400A, 50KA 4pole MCCB, Ics= 100% Icu rating Digital Voltmetre 0-500V with selector switch Digital Ammeter (0-400 A) with selector switch and CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of copper Bus Bar 500A OUTGOING Note : Outing feeder for pump should have digital ammeter with selector switchs, and LED type ON, OFF< trip indicating lamps) DOWN COMER PUMP 63 A, 50kA TPN MCCB, Icu=100% Icu, with suitable HP fully automatic Star/Delta starter with overload proction, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
253Providing and fixing of self illuminated / auto glow \\"EXIT\\" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
254Providing fixing, testing and commissioning of pressure vessel (minimum 450 mm dia & 1800 mm height) for pressurization of hydrant system complete with pressure gauge, valves at outlet / drain to operate as per operating sequences including 50 mm dia drain valve, air release valve with stop cock on the top Duly painted from inside and outside complete as required.
255Providing and fixing standard firemans axe with heavy rubber handle.
256Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57806792
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5.07 Crore
LAST DATE 22-10-2026
Authority
Authority Name Indo Tibetan Border Police Force
Work Description Tender for Construction Of Multi Purpose Hall Against The Authorized Area Of Community Centre, Info And Recreation Centre, Darbar Shed & Drill Shed) At Tpt Bn, Itb Police, Chandigarh
Basic Detail
Tender No ITBP/ENG/TPT/MPH/TENDER/26-870
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 01 Oct 2026
Submission Date 22 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 5.07 Crore
Tender Fee Ref. Documents
EMD 10.15 Lakhs
Exemption Not Available
Document List
7b353861-7d06-4802-8941-75f51d4221f1.html
BOQ_975702.xls
Tendernotice_1.pdf
TFMPHALLFORCPPP.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

7b353861-7d06-4802-8941-75f51d4221f1.html

xls

BOQ_975702.xls

pdf

Tendernotice_1.pdf

pdf

TFMPHALLFORCPPP.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders