Educational and Research Institute Government Departments Closing in 3 days TDR #57806753

Tender For Supply Installation Testing and Commissioning of Power Supply Cable From Switch Room To Mess Of Hall-5 And Supply Installation Testing and Commissioning of Flood Light And Allied Electrical Works In Tennis Court Complex And Elsewhere In Ii

Issued by Government Departments · Kanpur Nagar, Uttar Pradesh
Tender Value
1.62 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
3 days left
EMD
3242
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Power Supply Cable From Switch Room To Mess Of Hall-5 And Supply Installation Testing and Commissioning of Flood Light And Allied Electrical Works In Tennis Court Complex And Elsewhere In Iit Kanpur.

BOQ

Name of Work:- SITC of Power supply cable from switch room to Mess of Hall-5 and SITC of Flood light and allied electrical works in Tennis Court Complex and elsewhere in IIT Kanpur.
Sl. No. Item Description
1Laying of one no. PVC insulated, PVC sheathed / XLPE power cable of 1.1kV grade of size above 35 sqmm and upto 95 sq.mm.
2Direct in ground I/c excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
3In pipe
4In open duct
5On surface with MS clamp (clamped with 25 X3 mm MS flat clamp )
6Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted/welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
7Supplying and making end termination with brass compression gland, aluminium lugs for following size of PVC insulated & PVC sheathed / XLPE aluminium cable of 1.1kV grade as reqd.
83.5 x 50 sq.mm.
9Supply & Laying of 50 mm dia, 8Kg / cm², minimum 2.0 mm thick HDPE pipe, ISI mark in following manners as required complete.
10In ground i/c excavation sand cushioning protective covering, refilling of earth as reqd.
11Laying charges In Pipe
12Laying charges On Surface
13Laying charges in open duct
14Supply of one number PVC insulated & PVC sheathed/XLPE aluminium conductor steel armoured power cable of following sizes 1.1kV grade as per IS 7098 (part 1) 1988.
153.5 x 50 sq.mm.
16Supplying & drawing following sizes of FRLS PVC insulated copper conductor single core cable in / on the existing surface / recessed, PVC / steel conduit as reqd.
173 x 1.5 Sq.mm..
18S & F MCB of following pole and rating 240/415 volts, 10kA, 'C' series in the existing MCB DB complete with connection, testing & commissioning etc as reqd.
19Single Pole 6 amp to 32 amp
20LED Flood Light, powder coated pressure die cast aluminium (System umen efficacy >135lm/Watt): Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC,frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM 21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) ,SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
21250 watt
22Supply and drawing steel armoured, XLPE insulated, PVC intersheathed copper conductor 3 core round cable 1100 volt grade as per IS 7098 (Part 1) 1988 Complete as required.
233 core armoured 1.5 sq.mm
24Dismantling and fixing/refixing of LED light fittings integrated (with lamps) including connection,nut bolts, washer and screw etc. after removing old complete and depositing the dismantle in store as required.
25Above 9 meter and upto 12 Meter
26Locating fault in wiring rectifying removing & restoring supply the same & making good the damages etc as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57806753
AUTHORITY Government Departments
TENDER VALUE 1.62 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Supply Installation Testing and Commissioning of Power Supply Cable From Switch Room To Mess Of Hall-5 And Supply Installation Testing and Commissioning of Flood Light And Allied Electrical Works In Tennis Court Complex And Elsewhere In Iit Kanpur.
Basic Detail
Tender No 69/EE/Elect/2026-27
Bidding Type Tender
Location
City Kanpur Nagar
State Uttar Pradesh
Key Dates
Publish Date 30 Sep 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 1.62 Lakhs
Tender Fee Ref. Documents
EMD 3242
Exemption Not Available
Document List
BOQ_975682.xls
fb7e05d1-93c5-44f5-b193-7182c0f14432.html
Tendernotice_1.pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_975682.xls

html

fb7e05d1-93c5-44f5-b193-7182c0f14432.html

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail