Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #57806719

Tender For Provn Of Railway Underpass At Afs Uttarlai (File No. 82370/E8)

Issued by Statutory Bodies & Commissions/Committees · Barmer, Rajasthan
Tender Value
3.37 Crore
Estimated cost
Bid Submission
01 Dec 2026
19 days left
EMD
4.12 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Railway Underpass At Afs Uttarlai (File No. 82370/E8)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Amendment in tender date Date 01-Dec-2026

BOQ

Name of Work:- PROVN OF RAILWAY UNDERPASS AT AFS UTTARLAI (FILE NO. 82370/E8)
Sl. No. Item Description
1NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00 to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only.
2Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I.
3Lump sum price worked out for Site Clearance and development as listed in Sch 'A' Part II
4Lump sum price worked out for Demolition/Dismantling as listed in Sch 'A' Part III
5Lump sum price worked out for Internal Electrification as listed in Sch 'A' Part IV
6Lump sum price worked out for Internal Water Supply as listed in Sch 'A' Part V
7Lump sum price worked out for Roads/Path/Hard Standing Paved Area/Culvert as listed in Sch 'A' Part VI
8Lump sum price worked out for Sewage Disposal as listed in Sch 'A' Part VII
9Lump sum price worked out for Area Drainage as listed in Sch 'A' Part VIII
10Lump sum price worked out for External Electric Supply as listed in Sch 'A' Part IX
11Lump sum price worked out for External Water Supply as listed in Sch 'A' Part X
12Lump sum price worked out for Fencing, Gate & Boundary Wall as listed in Sch 'A' Part XI
13Lump sum price worked out for Standby Power Supply as listed in Sch 'A' Part XII
14Lump sum price worked out for Cooling Appliances as listed in Sch 'A' Part XIII
15Lump sum price worked out for Automation of Gate as listed in Sch 'A' Part XIV
16SCHEDULE 'A' PART - XV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6.
17Roads/Path/Hard Standing Paved Area/Culvert
18M&L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n.exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed.
19Sewage Disposal
20M&L for three layer LLDPE septic tank of 10 users designed to carry sewage and sullage water, excavation in any type of soil PCC 1:4:8 below foundation vent shaft etc complete with up flow filter including media complete all as specified & as directed.
21M&L Soakage well including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including interrupting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 mtr dia and 3.0 mtr effective depth complete all as specified & as directed.
22External Electric Supply
23Supply and lay for DWCPE (Double wall corrugated polyethylene) (SN8) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall bearing ISI marked with IS 14930 (Par-I &II) for protection of underground cables of followings size nominal outer dia & normal inner dia with all fittings laid in trenches/road/nallah or fixed along wall for cable protection complete all as specified and as directed.
24(a) Nominal outer dia 63 mm & nominal inner dia 50 mm dia
25(b) Nominal outer dia 120 mm & nominal inner dia 103.50 mm dia
26(c) Nominal outer dia 160 mm & nominal inner dia 136 mm dia
27Labour only for taking out serviceable HT UG cables of size 3 core 95 Sq mm from existing trench by excavation and earth work in any type of soil including and keeping aside for segregation of serviceable cable, PCC cover safe custody for reuse complete all as specified and directed.
28Labour only for relaying serviceable underground HT UG cable of size 3 core 95 Sq mm obtained from BOQ item No 19.00 here-in-before complete all as specified and as directed.
29S&F for Cable route indicator/marker made up of PCC block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/11KV CABLE/MES embossing on cable route indicator/marker including painting as per approved colour and buries in ground 45 Cm including necessary earth work (as required /order at site) complete all as specified and as directed.
30S&F for cable route indicator/marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/LT 433 VOLTS CABLE/MES or DANGER/MES” embossing on cable route indicator/marker including painting a per approved colour and buried in ground 45cm indicating necessary earth work (as required/ordered at site) complete all as specified and as directed.
31Supply, installation, Testing and commission of Outdoor type (IP54), Vacuum Circuit Breaker (VCB) 11KV, 630 Amps, 25KA-3 sec, IP-54 SF6 insulated, one side extensible, motorised vacuum circuit breaker & metering Panel Bus PT with Top LV, Battery & battery charger, Earth net switch & LIU (Configuration V+M), inside robotically welded stainless steel 304 (Non Ferrite one magnetic Grade) tank having min thickness 2.5 +/- 0.5 mm with IP67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of class 0.5 VCB should be provided with internal bus bar as well as earthing bus bars of electrolytic grade copper padlock provisions & complete with all accessories. The complete VCB must be type tested for internal arc 21KA for 1 sec with AFLR classification from Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site reparability features such as site replaceable bushing/coupling/mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediate VCB manufacture’s own make. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection complete all as specified and as directed. The unit shall include the following with all necessary standard fittings as required at site:-Note : Make of VCB are given in Appendix ‘B’. Channel partner/System Integrator/Authourized Partner/Licence partner of make of VCB should not be accepted.
32(a) Vacuum Circuit breaker consists of following accessories:-(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Draw out Type with CT Shorting feature, Graphical LCD Display (ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (iii) SF6 Gas pressure indicator on the gas tank. (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operations. (v) CT shall be minimum 50-100/1A, 2.5VA, 5P10 - 3 Nos. for protection (vi) CT shall be minimum 50-100/1A, 2.5VA, Class 0.5 - 3 Nos. for metering (vii) Right angle boot to be provided in each module (viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set (ix) Bus VT shall be 11KV/V3/110V/V3, 20VA, Class 0.5 - 3 Nos. for metering (x) Auxiliary VT shall be 11KV/230, 500VA for AC supply input to Battery Charger.
33(xi) Capacitive voltage indication fixed type system as per IE. (xii) Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. (xiii) Right angle boots (push on type) (xiv) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB. (xv) Necessary interlocking arrangement for safety and operations (xvi) One No. Operating Handle for Manual Operation and one no. manometer (xvii) Safety Interlocks shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (xviii) Above switchgear shall confirm to all relevant IEC/IS Standards.
34S&F for LED Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP65 protection security light fittings luminaries of capacity 70 watts with high power LEDs as light source and electric driver, 4kV in built and 10kV external surge protection with Top opening driver cover for easy maintenance with warranty option of 5year from date of installation with pre wired and necessary mounting arrangement and provision of 4Sqmm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as specified and as directed.
35S&F for Security light junction box of size 205x255x112 mm for luminaries, weather proof made out of polycarbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/wall mounting type comprising of MCB SP 10 Amps, fixed on pole with brackets and screws complete all as specified and as directed. Please Enable Macros to View BoQ information
36S&F for Security light junction box of size 205x255x112 mm for luminaries, weather proof made out of polycarbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/wall mounting type comprising of MCB SP 10 Amps, fixed on pole with brackets and screws complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57806719
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 3.37 Crore
LAST DATE 01-12-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Railway Underpass At Afs Uttarlai (File No. 82370/E8)
Basic Detail
Tender No 82370/E8
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 22 Oct 2026
Submission Date 01 Dec 2026
Open Date 03 Dec 2026
Finance
Tender Value 3.37 Crore
Tender Fee 2000
EMD 4.12 Lakhs
Exemption Available
Document List
1589a272-d6ee-49bc-8202-83f84e4940d1.html
BOQ_887852.xls
Drg.rar
Tender.rar
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 19 days
Dec 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Dec 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

1589a272-d6ee-49bc-8202-83f84e4940d1.html

xls

BOQ_887852.xls

rar

Drg.rar

rar

Tender.rar

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender