Tender For Provn Of Railway Underpass At Afs Uttarlai (File No. 82370/E8)
Tender Value
3.37 Crore
Estimated cost
Bid Submission
01 Dec 2026
19 days left
EMD
4.12 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Railway Underpass At Afs Uttarlai (File No. 82370/E8)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Amendment in tender date | Date | 01-Dec-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | NOTE: Schedule ‘A’ Part I to XII under Ser No. 1.00 to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. |
| 2 | Lump sum price worked out for BUILDINGS/ STRUCTURES as listed in Sch 'A' Part I. |
| 3 | Lump sum price worked out for Site Clearance and development as listed in Sch 'A' Part II |
| 4 | Lump sum price worked out for Demolition/Dismantling as listed in Sch 'A' Part III |
| 5 | Lump sum price worked out for Internal Electrification as listed in Sch 'A' Part IV |
| 6 | Lump sum price worked out for Internal Water Supply as listed in Sch 'A' Part V |
| 7 | Lump sum price worked out for Roads/Path/Hard Standing Paved Area/Culvert as listed in Sch 'A' Part VI |
| 8 | Lump sum price worked out for Sewage Disposal as listed in Sch 'A' Part VII |
| 9 | Lump sum price worked out for Area Drainage as listed in Sch 'A' Part VIII |
| 10 | Lump sum price worked out for External Electric Supply as listed in Sch 'A' Part IX |
| 11 | Lump sum price worked out for External Water Supply as listed in Sch 'A' Part X |
| 12 | Lump sum price worked out for Fencing, Gate & Boundary Wall as listed in Sch 'A' Part XI |
| 13 | Lump sum price worked out for Standby Power Supply as listed in Sch 'A' Part XII |
| 14 | Lump sum price worked out for Cooling Appliances as listed in Sch 'A' Part XIII |
| 15 | Lump sum price worked out for Automation of Gate as listed in Sch 'A' Part XIV |
| 16 | SCHEDULE 'A' PART - XV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. |
| 17 | Roads/Path/Hard Standing Paved Area/Culvert |
| 18 | M&L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like n.exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 19 | Sewage Disposal |
| 20 | M&L for three layer LLDPE septic tank of 10 users designed to carry sewage and sullage water, excavation in any type of soil PCC 1:4:8 below foundation vent shaft etc complete with up flow filter including media complete all as specified & as directed. |
| 21 | M&L Soakage well including excavation in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including interrupting chamber and screen chamber made of brick masonry in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 mtr dia and 3.0 mtr effective depth complete all as specified & as directed. |
| 22 | External Electric Supply |
| 23 | Supply and lay for DWCPE (Double wall corrugated polyethylene) (SN8) high density polythene pipes having corrugation on the outer wall and plain surface on the inner wall bearing ISI marked with IS 14930 (Par-I &II) for protection of underground cables of followings size nominal outer dia & normal inner dia with all fittings laid in trenches/road/nallah or fixed along wall for cable protection complete all as specified and as directed. |
| 24 | (a) Nominal outer dia 63 mm & nominal inner dia 50 mm dia |
| 25 | (b) Nominal outer dia 120 mm & nominal inner dia 103.50 mm dia |
| 26 | (c) Nominal outer dia 160 mm & nominal inner dia 136 mm dia |
| 27 | Labour only for taking out serviceable HT UG cables of size 3 core 95 Sq mm from existing trench by excavation and earth work in any type of soil including and keeping aside for segregation of serviceable cable, PCC cover safe custody for reuse complete all as specified and directed. |
| 28 | Labour only for relaying serviceable underground HT UG cable of size 3 core 95 Sq mm obtained from BOQ item No 19.00 here-in-before complete all as specified and as directed. |
| 29 | S&F for Cable route indicator/marker made up of PCC block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/11KV CABLE/MES embossing on cable route indicator/marker including painting as per approved colour and buries in ground 45 Cm including necessary earth work (as required /order at site) complete all as specified and as directed. |
| 30 | S&F for cable route indicator/marker made up of PCC Block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900x300x100mm thick with DANGER/LT 433 VOLTS CABLE/MES or DANGER/MES” embossing on cable route indicator/marker including painting a per approved colour and buried in ground 45cm indicating necessary earth work (as required/ordered at site) complete all as specified and as directed. |
| 31 | Supply, installation, Testing and commission of Outdoor type (IP54), Vacuum Circuit Breaker (VCB) 11KV, 630 Amps, 25KA-3 sec, IP-54 SF6 insulated, one side extensible, motorised vacuum circuit breaker & metering Panel Bus PT with Top LV, Battery & battery charger, Earth net switch & LIU (Configuration V+M), inside robotically welded stainless steel 304 (Non Ferrite one magnetic Grade) tank having min thickness 2.5 +/- 0.5 mm with IP67 degree of protection and enhanced BIL of 75 kVp internally to manager voltage surges and Air Insulated Metering Module of class 0.5 VCB should be provided with internal bus bar as well as earthing bus bars of electrolytic grade copper padlock provisions & complete with all accessories. The complete VCB must be type tested for internal arc 21KA for 1 sec with AFLR classification from Gas tank & Cable Chamber as per IEC 62271-200. HT RMU shall preferably have on-site reparability features such as site replaceable bushing/coupling/mechanism and gas refilling to have very less downtime in the event of bushing breakage and restoration can be done at site immediate VCB manufacture’s own make. The earthing bus bar shall be provided inside each cable compartment for solid earthing of cable shields. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection complete all as specified and as directed. The unit shall include the following with all necessary standard fittings as required at site:-Note : Make of VCB are given in Appendix ‘B’. Channel partner/System Integrator/Authourized Partner/Licence partner of make of VCB should not be accepted. |
| 32 | (a) Vacuum Circuit breaker consists of following accessories:-(i) Microprocessor based Numerical Protection Relay for Circuit Breakers - REF615, Feeder Protection and Control Relay, Protections 50, 51, 50N, 51N, 46, 49, 67, 67N, 32, 27, 59, 25, 81U, 81O, 95 Measurement for 3I,I0,3U,U0,Kw,KVA,PF,Hz,Kwh, 16 DI + 10 DO, One front RJ45 Port, One Rear RJ45 Port for IEC-61850 Protocol, Draw out Type with CT Shorting feature, Graphical LCD Display (ii) Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. (iii) SF6 Gas pressure indicator on the gas tank. (iv) Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10,000 mechanical operations. (v) CT shall be minimum 50-100/1A, 2.5VA, 5P10 - 3 Nos. for protection (vi) CT shall be minimum 50-100/1A, 2.5VA, Class 0.5 - 3 Nos. for metering (vii) Right angle boot to be provided in each module (viii) 2 x12 Volts, 26 AH Battery with Charger - 1 Set (ix) Bus VT shall be 11KV/V3/110V/V3, 20VA, Class 0.5 - 3 Nos. for metering (x) Auxiliary VT shall be 11KV/230, 500VA for AC supply input to Battery Charger. |
| 33 | (xi) Capacitive voltage indication fixed type system as per IE. (xii) Interlocked Cable box for front termination of the cable suitable upto 3 core 120 Sqmm, 11 KV XLPE cable (IP3X). Safety interlocked to prevent access to cable termination in live-condition. (xiii) Right angle boots (push on type) (xiv) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB. (xv) Necessary interlocking arrangement for safety and operations (xvi) One No. Operating Handle for Manual Operation and one no. manometer (xvii) Safety Interlocks shall be provided as per relevant IEC/IS Standards and Manufacturers directions. (xviii) Above switchgear shall confirm to all relevant IEC/IS Standards. |
| 34 | S&F for LED Energy saving new generation environmental friendly long life versatile pressure die cast aluminium IP65 protection security light fittings luminaries of capacity 70 watts with high power LEDs as light source and electric driver, 4kV in built and 10kV external surge protection with Top opening driver cover for easy maintenance with warranty option of 5year from date of installation with pre wired and necessary mounting arrangement and provision of 4Sqmm three core copper conductor cable multi stranded from fitting terminal to street junction box complete all as specified and as directed. |
| 35 | S&F for Security light junction box of size 205x255x112 mm for luminaries, weather proof made out of polycarbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/wall mounting type comprising of MCB SP 10 Amps, fixed on pole with brackets and screws complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 36 | S&F for Security light junction box of size 205x255x112 mm for luminaries, weather proof made out of polycarbonate housing fire retardant, non fusing, shock & rust proof, single piece moulded and cover with hinged door, pole/wall mounting type comprising of MCB SP 10 Amps, fixed on pole with brackets and screws complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Oct 22, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Dec 01, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 19 daysDec 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysDec 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender