Tender For Repair/ Maintenance Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories Under The Aor Of Poonch Under Ge 881 Ews
Tender Value
25 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
18 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of Lt Overhead Conductor, Underground Cable, Lt Panel And Allied Accessories Under The Aor Of Poonch Under Ge 881 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE 881 EWS C/O 56 APO NAME OF WORK: REPAIR/ MAINT OF LT OVERHEAD CONDUCTOR, UNDERGROUND CABLE, LT PANEL AND ALLIED ACCESSORIES UNDER THE AOR OF POONCH UNDER GE 881 EWS Contract No : GE/PNH-67/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavation in trenches n.exc 1.50m wide and n.exc 1.50m in depth for foundation etc. and getting out in hard/dense soil, complete all as specified and directed. |
| 3 | All as per Item No.01 above but for depth exceeding 1.50 m and not exceeding 3m complete all as specified and directed. |
| 4 | Returning, filling in including spreading,levelling, watering and well ramming in layers n.exc 25cm thick in soil completed all as specified and directed. |
| 5 | Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point as in soil complete all as specified and directed. |
| 6 | Supply ,laying and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 100 mm dia , conforming to IS 16205 complete with fittings and including cutting , jointing and clamping all as specified and directed. |
| 7 | Supply ,laying and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 80 mm dia , conforming to IS 16205 complete with fittings and including cutting , jointing and clamping all as specified and directed. |
| 8 | Supply ,laying and fixing DWC HDPE pipe for protection of power cable (orange in colour) of size 50 mm dia , conforming to IS 16205 complete with fittings and including cutting , jointing and clamping all as specified and directed. |
| 9 | Supply, laying, jointing and testing in replacement in trenches, passing through ducts/pipes, fixing along poles, jointing and testing ; XLPE cable insulated, screened, PVC bedded, galvanized steel wire or strip armoured electric power cable (heavy duty) with aluminium stranded conductor 1100 volts grade of size 3.5 core 185 Sq mm including taking down old unserviceable cable complete all as specified and directed . |
| 10 | Ditto as per ser item N0-08, but Sec . Area 120 Sqmm 3.5 core |
| 11 | Ditto as per ser item N0-08, but Sec . Area 95 Sqmm 3.5 core. |
| 12 | Ditto as per ser item N0-08, but Sec . Area 70 Sqmm 3.5 core. |
| 13 | Ditto as per ser item N0-08, but Sec . Area 50 Sqmm 3.5 core. |
| 14 | Ditto as per ser item N0-08, but Sec . Area 35 Sqmm 3.5 core. |
| 15 | Ditto as per ser item N0-08, but Sec . Area 25 Sqmm 4 core. |
| 16 | Ditto as per ser item N0-08, but Sec . Area 16 Sqmm 4 core. |
| 17 | Ditto as per ser item N0-08, but Sec . Area 10 Sqmm 2 core. |
| 18 | Taking down unsv PCC pole, Supplying, install and errect in true vertical position steel tubular swaged welded pole, 9.0 meter long, conforming to IS-2713 part-II, type 410 SP-31, complete with cast iron/MS base plate 6mm thick and of size 300x300mm, finial taper, pole cap, bolts, nuts, washers & screws etc., pole made out of ERW M.S. tubing including of holes of reqd Nos and size for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embedded in concrete, painting three signal red colour bends at lower portion of exposed pole starting from plinth block , each band of 300mm height at 300mm spacing, painting pole No the black paint by stenciled letters/figures of 8cm height complete all as specified and directed by Engr-in-charge.Note: Excavation, earth work and PCC in foundation of poles, coping etc shall be measured and paid separately in respected items. |
| 19 | Dismantling Cross arms, bracings, supports, clamps complete all as specified and directed. |
| 20 | Cross arms, bracings, supports, clamps (including stay clamps, clamps for fixing GI tubes for passing through of cables) and back plates fabricated out of standard steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as directed and inclusive of providing two coats of aluminium paint over a coat of primer after preparation of steel surfaces complete all as specified and directed. |
| 21 | S&F in replacement pin type insulator vitreous white/brown/green including one galvanized mild steel spindle and two galvanized iron washer and nut complete suitable for 1100 V grade 100mm height 65mm dia all as specified and directed. |
| 22 | M&L for replacement of Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts,100 mm high and 115 mm dia with tension clamps for conductor working pressure 1100 volts complete all as specified and directed. |
| 23 | Stay assembly complete with accessories i.e stay plate 300mm x 300mm x 6mm, galvanized thimbles, G.I. stay wire 7/4 SWG, loop type insulators, vitreous porcelain, white brown or green of large size with overall dimensions 90mm x 140mm, clearance of hole 25.5mm, etc and all other accessories as shown in electrical plate No.1 on Ser Page No.19-47 of MES Schedule Part-I complete. Note : Stay clamp, excavation and earth work and concrete for stay pit and insulator shall be measured and paid for separately complete all as specified and directed. |
| 24 | Supply and fix in replacement galvanised stay strand , size 7/3.15 mm for connecting stay assembly with MS clamps on poles complete all as specified and directed. |
| 25 | Supply and fix in replacement Loop insulator Porcelain, vitreous white/brown/green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, large size with overall dimensions 90mm x 140mm, clearance of hole 25.5 mm, Complete all as specified and directed. |
| 26 | Cradles, hexagonal/rectangular , fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified and directed. |
| 27 | Dismantling of ACSR conductors and removing from the site complete all as specified and directed. |
| 28 | S&F in replacement ACSR conductor, stretching properly on insulators and binding with aluminium binding wires, jumpers including fixing on insulators on each poles in span and tightening with permissible sag in between span etc of any size and type complete all as specified and as directed by Engineer-in-charge. |
| 29 | Trimming tree branches coming in proximity to LT over head lines and involved with over head lines where detected , over head lines to be cleared of tree branches at least 2.5 Mtrs apart from ACSR conductor from all sides all as directed. (Contactor is supposed to manage long wooden ladder atleast 32 feet height, rope and handsaw machine to clear the lines from tree branches having girth upto 6\\" dia at his own arrangement and cost ) complete all as specified and directed. |
| 30 | Re-streching of loose over head ACSR conductor of any type/GI wire and repair of the broken conductors and adding new length( if required) in place of old and burnt conductor of any size on existing poles with proper sagging including winding with winding wire all as specified. ( Old conductor shall be reused where required for repairing broken length of conductor as directed by Engr-in-charge) Note:- Five lines together will be measured as one span from pole to pole. |
| 31 | Painting to poles including cross arms, 'V' brackets, 'D' clamps, nuts, bolts, complete including painting with five strips of 30cm each black and white paint in alternate strips from the base of pole upto 1.5mtr height complete, spray painting with two coat of synthetic enamel paint of first quality silver paint over a coat of red oxide primer after and including complete removal of old paint by scratching, rubbing complete all as specified and directed. |
| 32 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below normal ground level, surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to galvanised steel earth lead strip 32mm x 6mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 40mm bore, including wire mesh, funnel, lugs, excavation in any type of soil, returning filling in & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregates and pit cover slab 50mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates reinforced with welded steel wire fabric or XPM weighing not less than 4Kg/sqm with cast iron frame including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance is not obtained,no payment shall be made till the desired earth resistance is not obtained. (ii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode. |
| 33 | Earthing complete with galvanized steel earth plate electrode 600 x 600 x 3.15 mm thick buried directly vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below normal ground level, surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to galvanised steel earth lead wire 4mm upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe medium grade GI 20 mm bore including protection pipe GI light grade 15mm bore, including wire mesh, funnel, lugs, excavation in any type of soil, returning filling in & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregates and pit cover slab 50mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates reinforced with welded steel wire fabric or XPM weighing not less than 4Kg/sqm with cast iron frame including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes:- (i) On testing if the desired earth resistance is not obtained,no payment shall be made till the desired earth resistance is not obtained. (ii) The chamber shall be constructed atleast 1.5 mtr away from the earth electrode. |
| 34 | Supply and fix in replacement GI tubing light grade with all fitting for protection of cable at road crossing 40mm bore complete all as specified and directed. |
| 35 | Supply and fix in replacement GI tubing light grade with all fitting for protection of cable at road crossing 80mm bore complete all as specified and directed. |
| 36 | M&L for replacement of MCCB 3 pole 63 Amps 415 volts with breaking capacity 16 KA. Ics=75% Icu,complete all as specified and directed. |
| 37 | M&L for replacement of MCCB 3 pole 100 Amps 415 volts with breaking capacity 16 KA. Ics=75% Icu,complete all as specified and directed. |
| 38 | M&L for replacement MCCB 3 pole 160 Amps 415 volts with breaking capacity 35 KA specified and as directed by Engr-In-charge. |
| 39 | M&L for replacement of MCCB 3 pole 200 Amps 415 volts with breaking capacity 36 KA, specified and as directed by Engr-In-charge. |
| 40 | M&L for replacement of MCCB 3 pole 250 Amps 415 volts with breaking capacity 36 KA specified and as directed by Engr-In-charge. |
| 41 | M&L for replacement of MCCB 3 pole 400 Amps 415 volts with breaking capacity 36 KA specified and as directed by Engr-In-Charge. |
| 42 | M&L for replacement of thimble aluminium 400 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 43 | M&L for replacement of thimble aluminium 185 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 44 | M&L for replacement of thimble aluminium 120 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 45 | M&L for replacement of thimble aluminium 95 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 46 | M&L replacement of thimble aluminium 70 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 47 | M&L for replacement of thimble aluminium 50 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 48 | M&L for replacement of thimble aluminium 35 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 49 | M&L for replacement of thimble aluminium upto 25 sqmm suitable for LT XLPE cable complete all as specified and directed. |
| 50 | PCC 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 51 | PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 52 | PCC 1:2:4, Type B-1 using 20 mm graded aggregate for coping of poles including necessary form work and finishing the exposed surface even and smooth without using extra cement complete all as specified and directed at site. |
| 53 | Energy efficient LED street light fittings, 35 Watt, 230 volt AC out door type with high pressure die-cast aluminium housing and heat resistant complete with dirver, lamp bracket with impact and corrosion resistant including thermal management in multiple optic complete with IP66 protection, with inbuilt surge protection device including taking down old us light fittings any type complete all as specified and as directed. |
| 54 | All as per item No. 52 above but for 60 Watt complete all as specified and directed by Engr-in-Charge. |
| 55 | All as per item No. 52 above but for 75 Watt complete all as specified and directed by Engr-in-Charge. |
| 56 | All as per item No. 52 above but for 90 Watt complete all as specified and directed by Engr-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender