Power Government Departments Closing in 3 days TDR #57805387

Tender For Replacement Of Obsolete Equipments By Way Of Supply Installation Testing and Commissioning of 220 Kv, 132 Kv And 33 Kv Cts, Cvts, Las And Allied Equipments At Various Grid Stations Under The Jurisdiction Of Tlmd Iv.

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
2.50 Crore
Estimated cost
Bid Submission
05 Nov 2026
3 days left
EMD
5 Lakhs
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Obsolete Equipments By Way Of Supply Installation Testing and Commissioning of 220 Kv, 132 Kv And 33 Kv Cts, Cvts, Las And Allied Equipments At Various Grid Stations Under The Jurisdiction Of Tlmd Iv.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-Oct-2026 Extension1 Date 29-Oct-2026
2 30-Oct-2026 Extension2 Date 05-Nov-2026

BOQ

Name of Work:- Replacement of Obsolete equipments by way of SITC of 220 KV, 132 KV and 33 KV CTs, CVTs, LAs and allied equipments at various grid stations under the jurisdiction of TLMD IV.
Sl. No. Item Description
1Design, Engineering. Manufacture,workshop testing, supply including packing and forwarding, transportation, delivery at site storage charges of;-
2MAIN EQUIPMENTS
3Capacitor Voltage Transformer
4Single phase, 50 c/s 220KV Capacitor Voltage Transformers (220/√3KV /110/√3V), one minute power freq withstand 460KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement.
5Single phase, 50 c/s 132KV Capacitor Voltage Transformers (132/√3) KV/ (110/√3V), one minute power freq withstand 275KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
6Voltage Transformer
7Single phase, 50 c/s 220KV Voltage Transformers (220/√3KV /110/√3V), one minute power freq withstand 460KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement.
8Single phase, 50 c/s 132KV Voltage Transformers (132/√3) KV/(110/√3V), one minute power freq withstand 275KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
9Single phase, 50 c/s 66KV Voltage Transformers (66/√3KV /110/√3V), one minute power freq withstand 140KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
10Single phase, 50 c/s 33KV Voltage Transformers (33/√3KV /110/√3V ), one minute power freq withstand 70KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
11Current Transformer
12Single phase, 50 c/s 245KV current Transformers (1200-800-400/1-1-1-1-1-1 A or as per site specification), 50KA for one second, rated dynamic current 100KA (peak), Class A insulation, Burden 20VA, 4 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
13Single phase, 50 c/s 245KV Current Transformers (1600-800/1-1-1-1-1 A or as per site specifications), 40KA for one second, rated dynamic current 100KA(peak), Class A insulation, Burden 20 VA, 4 NO PX CORE, 1 NO 0.2s class, Galvanised tank including first fill of transformer oil plus 20% extra and all accessories, auxillaries etc.
14Single phase, 50 c/s 145KV current Transformers (1200-600-300/1-1-1-1-1-1 A or as per site specification), 40KA for one second, rated dynamic current 100KA (peak), Class A insulation, Burden 20VA, 3 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
15Single phase, 50 c/s 145KV current Transformers (800-400-200/1-1-1-1-1-1 A or as per site specification), 40KA for one second, rated dynamic current 100KA (peak), Class A insulation, Burden 20VA, 3 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
16Single phase, 50 c/s 72.5KV current Transformers (72.5KV) (1250-625/1-1-1 A) or as per site specification), 31.5KA for three seconds, rated dynamic current 31.5KA (peak), Class A insulation, Burden 20VA, 2 NO PS Core, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
17Single phase, 50 c/s 36KV current Transformers (1200-600-300/1-1-1-1-1-1 A or as per site specification), 31.5KA for one second, rated dynamic current 31.5KA (peak), Class A insulation, Burden 20VA, 4 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
18Single phase, 50 c/s 36KV current Transformers (800-400-200/1-1-1-1-1-1 A or as per site specification), 31.5KA for one second, rated dynamic current 31.5KA (peak), Class A insulation, Burden 20VA, 4 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
19Surge Arrestor
20Single phase 50c/s, outdoor metal oxide gapless type, 200KV (rms) Surge Arrestor, Class-3 inculding Surge counters/monitors, insylating base all associated accessories, auxillaries etc.
21Single phase 50c/s, outdoor metal oxide gapless type, 120KV (rms) Surge Arrestor, Class-3 inculding Surge counters/monitors, insylating base all associated accessories, auxillaries etc.
22Single phase 50c/s, outdoor metal oxide gapless type, 60KV (rms) Surge Arrestor, Class-3 inculding Surge counters/monitors, insylating base all associated accessories, auxillaries etc.
23Single phase 50c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor, Class-3 inculding Surge counters/monitors, insylating base all associated accessories, auxillaries etc.
24Circuit Breaker
2566KV 3 Pole, SF-6 (72.5KV, 2000Amps of 3 phase, 50 C/s and 31.5kA for 3 sec) outdoor circuit Breaker with operating mechanism, all accessories, auxiliaries and marshalling boxes/kiosks, SF6 Gas (first filling plus 10 Kg, cylinder additional) alongwith supporting structures etc. complete in all respects . SS Body , Universal sping charging motor with mandatory spares.
2633KV VCB (36KV, 2000Amps of 3 phase, 50c/s and 31.5KA for 3 sec) outdoor type with all accessories and auxillaries along with supporting structures etc. completed in all respects SS Body, Universal spring charging motor with mandatory spares.
27Relays
28Numerical relay E/F and O/C relay with df/dt features.
29Master Trip relay.
30Handling, transportation, delivery at site, erection work, testing and commisssioning including cable wiring to the equipments and connections with the C&R Pannels;-
31MAIN EQUIPMENTS
32Voltage Transformer
33Single phase, 50 c/s 33KV Voltage Transformers (33/√3KV /110/√3V ), one minute power freq withstand 70KV rms GALVANISED TANK Acc Class 0.2 as per specific technical requirement
34Current Transformer
35Single phase, 50 c/s 36KV current Transformers (800-400-200/1-1-1-1-1-1 A or as per site specification), 31.5KA for one second, rated dynamic current 31.5KA (peak), Class A insulation, Burden 20VA, 4 NO PS Core, 1 No. 5P20, 1 NO, 0.2s class, Galvanized tank inculding first fill of transformer oil plus 20% extra and all accessories , auxiliaries etc.
36Surge Arrestor
37Single phase 50c/s, outdoor metal oxide gapless type, 30KV (rms) Surge Arrestor, Class-3 inculding Surge counters/monitors, insylating base all associated accessories, auxillaries etc.
38Circuit Breaker
3933KV VCB (36KV, 2000Amps of 3 phase, 50c/s and 31.5KA for 3 sec) outdoor type with all accessories and auxillaries along with supporting structures etc. completed in all respects SS Body, Universal spring charging motor with mandatory spares.
40Dismantling and shifting of old equipment along with allied material to divisional stores.
4102 nos. All in one Desktop 14th Gen 24inch display along with antivirus, genuine windows with 02 nos. UPS double battery and 01 nos. Executive Chair specified as (360 Degree Managerial Chair with Adjustable Height and Retractable Wooden Frame with Upholstery, PU Leather and strong Metal Base having dimensions 54D x 55W x 83H Centimeters) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57805387
AUTHORITY Government Departments
TENDER VALUE 2.50 Crore
LAST DATE 05-11-2026
Authority
Authority Name Jammu And Kashmir Power Development Department
Work Description Tender for Replacement Of Obsolete Equipments By Way Of Supply Installation Testing and Commissioning of 220 Kv, 132 Kv And 33 Kv Cts, Cvts, Las And Allied Equipments At Various Grid Stations Under The Jurisdiction Of Tlmd Iv.
Basic Detail
Tender No TLMD-IV/J/12 Dated 30-09-2026 of 2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 30 Oct 2026
Submission Date 05 Nov 2026
Open Date 07 Nov 2026
Finance
Tender Value 2.50 Crore
Tender Fee 5900
EMD 5 Lakhs
Exemption Not Available
Document List
84f0107b-35b0-420e-9e2d-2f16f7fe6157.html
BOQ_1105057.xls
SBD.pdf
Tendernotice_1 (23).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 05, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 3 days
Nov 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Nov 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

84f0107b-35b0-420e-9e2d-2f16f7fe6157.html

xls

BOQ_1105057.xls

pdf

SBD.pdf

pdf

Tendernotice_1 (23).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender