Tender For Providing 33 Kv Feeder Line And Supply Installation Testing and Commissioning of Transformer, Dg Set, Rmu And Other Electrical Work For Electric Bus Depot, Sector-90, Noida.
Tender Overview
Project Description
Tender for Providing 33 Kv Feeder Line And Supply Installation Testing and Commissioning of Transformer, Dg Set, Rmu And Other Electrical Work For Electric Bus Depot, Sector-90, Noida.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 13-Oct-2026 | Corrigendum for Additional Required Condition and date extended | Date | 19-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply of steel tubular pole 11 mtrs long designated at 410-sp 56 in 1:3:6 cement concrete foundation including excavation back filling etc complete in all respects UPERC P-30 |
| 2 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 10.00 metre and upto 12.00 metre DSR Electrical 2018/I.No. 11.3.4 |
| 3 | Supply of 300 sq. mm 3 core high conductivity aluminum strand compacted circular conductor XLPE armoured 33 KV(E) Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment complete in all respects as per direction of E/I. Make: Gloster/ /Universal/ Polycab/ Havells/ KEI/ Diacab/ (as per approved rate) |
| 4 | Laying of One number XLPE power cable of 33KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.7.2/P34) Above 120 Sqmm and upto 400 Sqmm |
| 5 | S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson/ Capseal as per direction of E/I. (UPERC P-47) |
| 6 | S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. (UPERC P-47) |
| 7 | Painting of the electric pole with 2 coat of AI paint over red oxide primer complete in all respects As per PS No. 634 |
| 8 | S/F of 6\\" dia G.I. pipe B class for cable duly duly clamped with support by 1 no. with clamps for 20x3mm MS flat, bolt, nuts and washer required for proper completion of work (UPERC P-47) |
| 9 | Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50mm, inner Dia 25, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with food mixture of retaining capacity one earth lead of 25mm x 3mm G.I. Strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra.) along with 30 cm squrare C.I. frame with hinged cover masonry housing . ps 725 (B) |
| 10 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 300 Sqmm |
| 11 | S/Laying of heavy density poly ethylene pipes ISI marked anti rediant grade OD 160mm dia PN-8 PE 100 (PE 400) grade as per IS code 4984 with excavation at a depth of 1.20 Mtr below ground level i/c the cost of cutting of pipes for making up to length and making joints complete all respects as per direction of E/I. (creator poly extrusion/duraline/rex/times/ narander plast/pioneer make). (AOR) |
| 12 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to ISI 14930, part-II complete with filling and cutting, jointing etc. direct in ground (75 cm below ground level ) including sand cushioning and protective covering etc. complete in all respect .( Trenchless if required) Rex/Duraline/Time/CPE make. as per DSR 2018 item no.14.16.2 page no.49. |
| 13 | Providing and laying of MS Pipe of 200mm dia 6mm thickness as per IS 3589 grade FE 410 through trenchless method including jointing of pipe, excavation of thrust pit and receiving pit of required size with all T & P and the excavation & back filling with compaction complete as per specification for road crossing by H.D.D machine method pipoe will be installed at minumum depth 2M to 3 m below the ground surface or downward as per site condition in required slope.(AOR) |
| 14 | Supplying of channel iron 75mmx40mmx6mm(7.14 Kg Per mtr) pole top bracket/cross arm for single 11 kV overhead line conductor complete with 50mmx6mm flat iron clamp, bolts, nuts and washer including drilling holes for insulator pins bolts and nuts etc, and painting with primer and finish paint as required (Electrical DSR-2018 item no. 13.2 pg.44) |
| 15 | S/E of straight MS Channel 50x100x2600 mm. (9.2 Kg/M) 2.60 M long as per design with required clamps made of M.S. flat of size 50x6 mm. with nut & bolts etc. as per direction of E/I. .((UPERC P-30) |
| 16 | S/E of over head line with ACSR Panther Conductor on pole/service braket including binding etc. Complete in all respects as per PS No. 627 |
| 17 | Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules PS No. 1109 |
| 18 | Supply and laying of 32 mm x 6 mm G.I. strip from earth electrode directly in the ground as required complete in all respect. PS No. 717 |
| 19 | S/E of Stay set atleast 3.5 M away the pole Complete with galvan ished 19mmdiax 1.80m long stay rod, 30cmx30cmx6.3mm anchor plate thimble, Stay clamps, Stay insulator, 19mmx600mm stay double screw tightner 7/3.5mm of G.I. Wire etc. 1:3:6 (cement concrete) PS No. 631 |
| 20 | Numbering of poles with combination of yellow and black colour paint etc complete in all recpects as per direction of E/I (AOR) |
| 21 | Supplying and erection of 33 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required..(DSR Electrical 2018/Item 13.23 Page 50) |
| 22 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.(AOR) |
| 23 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required.bituminous portion..(AOR) |
| 24 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge .(AOR) |
| 25 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 26 | Providing and laying 60mm thick factory made cement concrete interlocking paver block kof M-30 grade made by block making machine with strong vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of E/I (AOR) |
| 27 | Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.DSR-2018 Item No.14.06 |
| 28 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 29 | L.T. Cables : Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-in Charge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS No. 501.( Make: Gloster/ Polycab/ Havells/KEI) |
| 30 | 400 sq mm 3.5 core |
| 31 | 185 sq mm 3-1/2 core |
| 32 | Supply of following type high conductivity aluminium strand compacted circular conductor XLPE armoured 11 KV Cable neutral earthed system confirming to IS 7098-Part-II (1985) with latest amendment at a depth of 900 mm. below ground level over a cushion of 100 mm. thick sand around and protect with brick on sides and top of cable shall be properly connecting with the earth conductor by clamps etc. with the cost of all material, labour, T&P etc. required for proper completion of the work. (CCI/ Gloster/Havells/Diacab/KEI/ Polycab make)(UPERC 2019 Pg-28) |
| 33 | i) 185 Sq.mm. 3 Core E-48 |
| 34 | Laying of One number PVC insulated and PVC sheathed/ XLPE power cable of 11KV grade of following size in the existing RCC/ HUME/ METAL/HDPE pipe as required.(DSR elect 2018 Item.N. 8.3.2/P31) Above 120 Sqmm and upto 400 Sqmm |
| 35 | S/F of jointing of following sizes outdoor/indoor type 11 KV jointing kit heat Shrinkable type for 11 KV Cable including cost of all material, labour, T&P etc. for proper completion of the E/I. (Raychem/Denson Make) uperc Pg-29 |
| 36 | 185 Sq.mm. |
| 37 | S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as pe direction of E/I PS No. 504. i) 185 Sqmm |
| 38 | S/Making of Straight through joint suitable for 185 sq.mm x 3 core 11 KV armoured cable as per ISS & complete as per the direction and satisfaction of E/I (Raychem, Denson, Cabseal Make) UPERC 2019 Pg-29 |
| 39 | Providing, installation testing & commissioning of Diesel Generating Set along with having prime power rating 1250 KVA, 415 Volts at 1500RPM, 0.8 lagging Factor at 415 V suitable for 50 Hz, 3 phase system and for 0.85 load factor and consisting of the following:- |
| 40 | Diesel Engine |
| 41 | Diesel Engine 4 stroke radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator at 400C, 50% RH & at 1000 metre MSL and confirming to BS 5514, bs 649, is 10000, capable of taking 10% overloading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. |
| 42 | Engine Mounted Instrument Panel fitted with and having digital display for following: |
| 43 | Start- stop switch with key. |
| 44 | Water Temperature indication |
| 45 | Lubrication Oil pressure indication |
| 46 | Battery charging indication |
| 47 | RPM indication |
| 48 | Over Speed trip Indication |
| 49 | Low lubrication oil trip indication |
| 50 | Engine Hours Indication |
| 51 | Alternator: |
| 52 | Synchronous alternator rated at 1250 KVA, 415 Volts at 1500 RPM, 3 phase 50 Hz, AC Supply with 0.8 lagging power factor at 400C, 50% RH & at 1000 metre MSL. The alternator shall be having SPDB enclosure, brushless, continuous duty, self-excited and self-regulated through AVR confirming to IS:4722/ BS 2613 suitable for tropical conditions and with class- F insulation. |
| 53 | Base Frame & Foundation |
| 54 | Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. |
| 55 | Fuel Tank: |
| 56 | Daily service fuel tank of 990 litres capacity, fabricated out of 3mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class 'C pipes of suitable dia. Complete with valves level indication & accessories as required as per specifications |
| 57 | Exhaust System : |
| 58 | Dry exhaust mainfold with hospital grade exhaust silencer and catalytic convertor. |
| 59 | Starting System: |
| 60 | 24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with 2 Nos. of batteries (25 plates, 160 AH lead Acid type) as required as per specifications. |
| 61 | Diesel Generating Set 1250 K.V.A. described as above. Make Kirloskar, Greaves cotton, Cuummins, Sudhir, Jackson) |
| 62 | Supply, installation, testing & commissioning of 33 Kv Outdoor type extensible 3 way ring main unit (RMU Should have two Incomer and one outgoing) floor mounted with internal copper busbars,consisting of 2 Nos Fixed type Motoried Load break switches and 01 Nos fixed type motorized vaccum circuit breaker including protection metering with CT& PT(33/110V) and Communication including Foundation and accesories etc complete in all respects.(2LBS+1VCB) The complete RMU shall be consisting of followings: |
| 63 | All VCB module shall have 630A VCB for making & breaking of fault current alongwith Earth Swicth of full making capacity. |
| 64 | All VCB module shall have Auxiliary powered numerical protection relay having Over Current, earth fault with Modbus protocol (RS485) complaint with programable 6 DO & 4DI. |
| 65 | Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder. |
| 66 | SF6 Gas pressure indicator on the gas tank. |
| 67 | Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO amd suitable for 10000 mechanical operation. |
| 68 | CT shall be minimum 40/1A ,2.5VA , 5P20 - 3 nos. for protection for each VCB Module. |
| 69 | Auxiliary VT shall be 33KV/230 ,500VA for AC supply input to Battary Charger. |
| 70 | 2X12V, 26AH Battary with Charger - 1 Set |
| 71 | Touch proof screen seperable right angle boot to be provided in each module as RMU OEM's recomanded make and termination to be done by RMU OEM at site. (Rate Approved in AOR). (Make Siemens, ABB, Schneider, CG) |
| 72 | Supply installation testing & commissioning of 33 KV VCB /SF6 Braker Three Panel Board indoor Type as 1 Incomoing and 2 Outgoing shall be metal clad floor mounting complete as per specification and as described 1250 A VCB/SF6 Breaker of 18.4 KA of Higher capacity ruputuring capacity at 33 KV rated, Totally enclosed. Air insulated metal clad housing floor mounting, Horizontal isolation, vermin proof, fully interlocked horizontal drawout type having isolation features and control devices complete. (Make Siemens, ABB, Schneider, CG) |
| 73 | Supplying, installation, testing and commissioning of 2500 KVA capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 33/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural Air Natural] copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better),Dielectric material shall be type -A, suitable for out door/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x400 sqmm XLPE cable of 33 KV grade, including bus trunking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS 1180 (Part-3) including first filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with +12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible. temperature-rise shall not exceed 40 0C for oil and 45 0C for winding up to 200 KVA and 45 0C for oil and 50 0C for winding for above 200 KVA. Inside of tank shall be painted with varnish or liquid resistant paint. |
| 74 | For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall B44be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g) Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i) Lifting lugs for the omplete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); |
| 75 | n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Buchholz relay for transformers above 800 kVA. p) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. q) Bird guard; r) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit s) Jacking pads (for transformer above 1 600 kVA); t) Additional Neutral separately brought out on bushing for earthing. u) Magnetic oil level gauge (for transformer above 1600 kVA) with low oil level alarm contact; v) Non return valve (for conducting pressure test); w) Pressure relief device or explosion vent x). Monogram Plate y) Inspection cover z). Detachable type radiators with top and bottom shutoff valve. aa) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. bb) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. (Make ABB, CG, Schneider, Voltamp with 15 Years Warranty |
| 76 | Supply, Installation, Testing & commissioning of Sheet Moulded Compound and Thermoplatic LT Distribution box for 3 Phase Out door connection to LT Line consumers through incl. 2500A TPN ALUMINIUM BUSBAR having these accessores & equipments :-. |
| 77 | INCOMER FOR TRANSFORMER a) 01 Nos. 2000A FP 50KA ACB EDO TYPE - MPR O/L, S/C E/F |
| 78 | METERING :-a) 01 Nos. MULTIFUNCTION METERb) 03 Nos. 2000/5A CT CLASS-1c) 03 Nos. INDICATION LED LAMP RYB d) 03 Nos. ON/OFF / TRIP INDICATING LIGHT e) 07 Nos. 2A SP MCB |
| 79 | INCOMER FOR DG SET a) 01 Nos. 2000A FP 50KA ACB EDO TYPE - MPR O/L, S/C E/F |
| 80 | METERING :-a) 01 Nos. MULTIFUNCTION METERb) 03 Nos. 2000/5A CT CLASS-1c) 03 Nos. INDICATION LED LAMP RYB d) 03 Nos. ON/OFF / TRIP INDICATING LIGHTe) 07 Nos. 2A SP MCB f) AMF relay g) Suitable Control Contactorh) Timer |
| 81 | INCOMER FOR SOLAR a) 01 Nos. 2000A FP 50KA ACB EDO TYPE - MPR O/L, S/C E/F1 |
| 82 | METERING :-a) 01 Nos. MULTIFUNCTION METERb) 03 Nos. 2000/5A CT CLASS-1c) 03 Nos. INDICATION LED LAMP RYB d) 03 Nos. ON/OFF / TRIP INDICATING LIGHT e) 07 Nos. 2A SP MCB |
| 83 | NCOMER FOR BSUS ( BATTERY STORAGE UNIT SYSTEM) |
| 84 | METERING :-a) 01 Nos. MULTIFUNCTION METERb) 03 Nos. 2000/5A CT CLASS-1c) 03 Nos. INDICATION LED LAMP RYB d) 03 Nos. ON/OFF / TRIP INDICATING LIGHT e) 07 Nos. 2A SP MCB |
| 85 | OUTGOING |
| 86 | a) 01 Nos. 1000A FP 50KA ACB EDO TYPE - MPR O/L, S/C E/F for APFC Panel |
| 87 | b) 05 Nos. 400A FP 36KA MCCB WITH ROTARY HANDLE AND SPEADER LINK- MPR |
| 88 | c) 02 Nos. 400A FP 36KA MCCB WITH ROTARY HANDLE AND SPEADER LINK( Spare ) |
| 89 | d) 06 Nos. 100A FP 36KA MCCB WITH ROTARY HANDLE AND SPEADER LINK ( Spare ) |
| 90 | including Nuts, Bolts, Washers, Ferul Numbers, Cable Ties, Tie Base, Copper PVC Control Wire, Power Wire, Copper Thimbles, Panel Locks, I-Hooks, PVC Tape, Insulators E- type, L-Type , Round Type, MCB Chanel, Pvc Chanel, Connector Chanel, Connectors, Foam Gaskit Etc |
| 91 | Construction Panel shall be free standing floor /wall mounted, dust and vermin proof construction Load Bearing - 2.0 mm. CRCA sheet Non load Bearing - 1.6 mm. CRCA sheet Gland Plate -2.0 mm. undrilled detachable |
| 92 | Paint- Surface of enclosure shall be pre treated by seven tank process.- Powder Coated, inside and outside Siemens Grey,(RAL7032)- Base frame shall be painted with Black |
| 93 | Bus bars- Electrolytic grade Copper bus bars of required ratings shall be provided- Busbar shall be supported on SMC supports.- Busbar shall be insulated with heat shrinkable PVC sleeves color coded |
| 94 | Name Plates- Each feeder shall have engraved anodized Al nameplates with each feeder details & rating of feeder.- Feeder name plates, Panel name plate and manufacturers name plate shall besecured by screws- MV Danger notice plate shall be provided |
| 95 | Earth bus- A continuous earth bus of Al shall run at bottom |
| 96 | Panel shall have removable gland plates at Top/Bottom as required |
| 97 | Bus bars & Cable entry shall be from Top/Bottom as required |
| 98 | Wiring- All internal wiring with PVC insulated Copper wires.- Current Transformers secondary circuit shall be wired by 2.5sq.mm PVC insulated copper wires.- Control wiring shall be with 1.5sq.mm PVC insulated copper wires.- Identification ferrules shall be used at both ends of wires |
| 99 | Necessary control fuses &terminals provided as required |
| 100 | The panel supply and installation,testing and commissioning with all above accessories complete in allrespects as per direction of E/I |
| 101 | Main L.T. Panel describe as above.(AOR) (Make RP Control, Advance Panel, Tricolite, Slemens, CG) |
| 102 | FRP fencing (6 feet height including civil work) as per UPERC 2019 Page 53 |
| 103 | Plinth of Transformer as per UPERC 2019 Page 53 |
| 104 | Cable Trench as per UPERC 2019 page 53 |
| 105 | Interlocking tiles inside Transformer fencing as per UPERC 2019 page 53 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender