Water Resources and Irrigation Government Departments Closing in 12 days TDR #57799741

Tender For Providing, Installation, Testing And Commissioning Of 400 Kva Voltage Stabilizer Along With Allied Works At Lis Kothey Kalyana New

Issued by Government Departments · Jammu, Jammu and Kashmir
Tender Value
8.50 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
12 days left
EMD
25520
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Providing, Installation, Testing And Commissioning Of 400 Kva Voltage Stabilizer Along With Allied Works At Lis Kothey Kalyana New

BOQ

Name of Work:-
Sl. No. Item Description
1Providing, Installation, testing and commissioning of 400 KVA voltage stabilizer along with allied works at LIS Kothey Kalyana New.
2Providing, Installation, Testing and Commissioning of 03 phase step up manually operated copper wound oil cooled voltage stabilizer conforming to relevant IS Code suitable for operation on unbalanced input voltage range and balanced output voltage as mentioned below for 03 phase A.C supply. The stabilizer shall be copper wound and the complete unit should be in steel case enamel painted and fitted with steel wheel rollers for easy portabilityThe other detailed specifications are as under: -Capacity: 400 KVAInput Voltage: 120 - 380 VoltsOutput Voltage :415 + 5%Frequency:50+3%Hz1. Core: The core should be of first quality of CRGO Silicon steel.2. Transformer oil: The transformer oil to be used has to be ISI Marked conforming to IS 335 with latest amendments.3. Copper conductor: The conductor should be 99.95% electrolytic copper.4. Container Gauge: The quantity of transformer oil used and the size of container should be mentioned and sheet used for manufacture of voltage stabilizer should be 14 to 16 SWG and gauge of the sheet used for fabrication of panel should be 16/18 SWG.5. Instruments: The voltage stabilizer shall be fitted with MCCB, Voltmeters (for both input and output voltage), Ampere meter, selector switches, indicator lamps, high voltage cut off relay, earth fault relay, single phase voltage preventor cut off alarm. The MCCB/fuses should be of E.E/GE/L&T/Siemens/BCH/SE or equivalent ISI make. The relays shall be Minilac/E.E./ECE. or equivalent ISI make. Similarly, voltmeter, ammeter, selector switches and indicator lamps shall be or equivalent ISI make.6. Bypass Switch: The equipment shall be provided with bye pass switch of suitable capacity of L&T / Havells / GE or equivalent ISI make.7. Rotary Switch: The Rotary Switches provided to adjust the output voltage of all the 03 phases should be of suitable rating and reputed ISI make and of heavy duty to withstand all the tests and working load. The rotary switch should have 8 steps with 02 steps down, 05 steps up and step No. 3 for line voltage.8. Terminal block: Terminal block for input and output connections should be of a reputed ISI make and meant for heavy duty.9. Characteristic Features: The three phase Manually operated copper wound oil cooled voltage stabilizers shall have the following characteristic features:-i. Continuous duty performance at ambient temperature 10 deg C to 55 deg C.ii. Stable and effective under system power factor and frequency fluctuation as well as overload upto 15% and under load upto 50% of the connected load.iii. Low internal impedance.iv. Negligible wave form distortion during starting under operation and stopping conditions.v. Accommodate the effect of higher starting current and should be able torecover from the shock.vi. No over shooting or hunting.vii. Negligible phase shift ensuring no change in system power factor.viii. The capacity of oil tank should be indicated.ix. The stabilizer shall have:a) Suitable breather.b) Leak proof de-sledging and drain cock for transformer oil.c) Lifting hooks provided at suitable positions for handling of the equipment.d) Oil gauge for monitoring level of transformer oil. x. The equipment shall be designed and manufactured ensuring the safety requirements as envisaged in IS: 8447 and IS: 302 both with latest amendments.xi. The stabilizer should be provided with suitable arrangement to avoid any seepage of water into the voltage stabilizer during storage / handling.10. Installation & Commissioning: The firm shall get the stabilizer installed inside the pump Room at a suitable place by engaging technically skilled persons. Testing first on idle load and then on full load under the supervision of firms technically skilled persons and commissioning.11.Marking : Stabilizer shall be marked with manufacturer’s name and trade mark on the plate fitted on the stabilizer indicating rating in KVA, range of input and output voltage, rated output current, frequency, number of phase, type of load viz. unbalanced input and balanced load, quantity of transformer oil and also the reference to the IS: standard.Providing/fitting of approx. 30metresingle core 400sq mm aluminium cable from the change over to the input/output of the voltage stabilizer with proper thimbling of the cable ends. The job includes cost of material, labour charges i.e. engagement of skilled and semi-skilled labour, hire charges of crane, tools and tackles and testing, commissioning and installation charges at site. Complete job.Complete job.Note: The tenderers should visit the site along with concerned J.E before quoting the rates.
3Rebate on Old Parts Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57799741
AUTHORITY Government Departments
TENDER VALUE 8.50 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Irrigation And Flood Control Department
Work Description Tender For Providing, Installation, Testing And Commissioning Of 400 Kva Voltage Stabilizer Along With Allied Works At Lis Kothey Kalyana New
Basic Detail
Tender No MID/J/e-NIT/2026-27/68
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 30 Sep 2026
Submission Date 14 Oct 2026
Open Date 15 Oct 2026
Finance
Tender Value 8.50 Lakhs
Tender Fee 1000
EMD 25520
Exemption Not Available
Document List
1a307987-d545-4247-aac4-b6403cdcdff9.html
BOQ_1105060.xls
SBD68.pdf
Tendernotice_1 (23).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

1a307987-d545-4247-aac4-b6403cdcdff9.html

xls

BOQ_1105060.xls

pdf

SBD68.pdf

pdf

Tendernotice_1 (23).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders