Public Administrative Department Local Bodies Closing in 6 days TDR #57798411

Tender For Improvement And Development Of electrical installation At Mcd Primary School, Gautam Vihar School (Ward No-231) Under Shahdara North

Issued by Local Bodies · Delhi, Delhi
Tender Value
7.23 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
6 days left
EMD
16000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement And Development Of electrical installation At Mcd Primary School, Gautam Vihar School (Ward No-231) Under Shahdara North

BOQ

Name of Work:- Improvement and development of E.I at MCD Primary School, Gautam Vihar School (Ward No-231) under Shahdara North
Sl. No. Item Description
1Rewiring for light point/fan point/call bell point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required (a) group C
2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
3Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a)2x2.5 sq. mm + 1x2.5 sqmm earth wire
4(b)2x6 sq. mm + 1x6 sqmm earth wire
5(c )2x4 sq. mm + 1x4 sqmm earth wire
6(d)4x2.5 sq. mm + 2x2.5 sqmm earth wire
7Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.(a)25 mm
8Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required (a) 6 Module (200mmX75mm)
9(b)8 Module (125mmX125mm)
10(c )12 Module(200mmX150mm)
11Supply & Fixing following modular switch/socket on the existing modular plate & switch box i/c connections but excluding modular plate etc.as reqd. (a)5/6 Amp.Switch
12(b)3 pin 5/6 Amp.Socket Outlet
13(c )15/16 Amp.Switch
14(d)6 pin 15/16 Amp.Socket Outlet
15Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator (a)8 way, double door
16(b)6 way, double door
17Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(single pole)
18Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)63 amps
19(b)40 amps
20Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance asper IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulatorfor speed control and all remaining accessories including safety pin, nut bolts, washers, temperaturerise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply,Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
21Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
22Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required
23Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
24Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
25Providing and fixing following capacity MCCB disconnector fuse switch unit inside the existing cubicle panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. (a) 100 Amp 30 KA FPMCCB
26(b) 200 Amp 36 KA FPMCCB
27Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size: (a) 2X6 sqmm
28(b) 4X25 sqmm
29laying and fixing of one number PVC insullated/ PVC Sheathed/ XLPE power cable of 1.1 Kv grade of following size on wall surface as required. Up to 35 sq mm (Clamped with 1 mm saddle).
30laying and fixing of one number PVC insullated/ PVC Sheathed/ XLPE power cable of 1.1 Kv grade of following size in the existing masonry open duct as required. Up to 35 sq mm.
31Supply of 12\\" (300 mm) sweep, 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required.
32Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
33LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and 85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10%as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beamangle 30 deg-120deg as per the application and theproject requirement, suitable tilt able fitting, life time(LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM(Standard Deviation Colour Matching) <5,Maximum power consumption should not morethan the specified rating and Fixture shall be ofrelevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,PVC insulated copper conductor single core cableand earthing etc. as required with Minimum 5 yearOEM warranty. System lumen efficacy ≥120 and<135 lm/Watt output . LM79 & LM80 Test reportand all testing required for LED fixtures as perBIS shall be submitted.. Shape size and CCT shallbe as approved by Engineer-in-Charge as perrequirement. (Thermal management: heat sink ofaluminium housing such that LED junctiontemperature shall not rise above 90°C).150 watt
34P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
35LED Batten light (System lumen efficacy ≥120 <135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 18- 22 watt
36SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
37SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color
38Providing and fixing of 4.5 KG CO2 type fire extinguisher squeeze grip type, trolly wheelas well mounted type complete in all respect with ISI mark i/c fixing arrangement etc as required.
39Providing and fixing ABC (Aluminium Phosphate) power type fire extinguisher of 6kgs capacity complete in all respect with isi mark i/c fixing arrangement etc as required.
40Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required New Model (Light Weight)
41Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
42Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57798411
AUTHORITY Local Bodies
TENDER VALUE 7.23 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Improvement And Development Of electrical installation At Mcd Primary School, Gautam Vihar School (Ward No-231) Under Shahdara North
Basic Detail
Tender No EE(E)-I/Sh.N/MCD/26-27/TC-31/2
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 30 Sep 2026
Submission Date 07 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 7.23 Lakhs
Tender Fee 590
EMD 16000
Exemption Not Available
Document List
2ec90940-e376-417b-92ca-8b9c3ee68e8e.html
BOQ_341458.xls
circular.pdf
Conditions231.pdf
GCC2024.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

2ec90940-e376-417b-92ca-8b9c3ee68e8e.html

xls

BOQ_341458.xls

pdf

circular.pdf

pdf

Conditions231.pdf

pdf

GCC2024.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders