Tender For Repair / Maintenance Of Electric Motors And Pump Set, Starters, Ats Panels,Switch Gears And Connected Works Of Various Mes Installation At Dagshai Under Ge Kasauli.
Tender Value
40 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
15 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Solan → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair / Maintenance Of Electric Motors And Pump Set, Starters, Ats Panels,Switch Gears And Connected Works Of Various Mes Installation At Dagshai Under Ge Kasauli.
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting /unscrewing coupling for 220 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: (i) All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:-(ii) Machinery breakdown complaint to be attended within 12 Hrs and after repairing the same to be fixed and tested within 48 Hrs. |
| 2 | Coupling Set suitable for 220 HP Pumping set |
| 3 | Replacement of gun metal impeller |
| 4 | Replacement of gun metal Bush |
| 5 | Replacement of Gland Sleeve |
| 6 | Replacement of body Neck ring gun metal |
| 7 | Replacement of Pump shaft stainless steel |
| 8 | Counter Plate stainless steel |
| 9 | Diffuser Packing |
| 10 | Impeller brazing machining and reboring |
| 11 | New Key way of impeller disc |
| 12 | Diffuser outer dia brazing and machining |
| 13 | Impellers outer dia brazing and machining |
| 14 | Disconnecting /unscrewing coupling for 150 HP , 125 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: (i) All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:-(ii) Machinery breakdown complaint to be attended within 12 Hrs and after repairing the same to be fixed and tested within 48 Hrs. |
| 15 | Coupling Set suitable for 150 HP /125 HP Pumping set |
| 16 | Replacement of gun metal impeller |
| 17 | Replacement of gun metal Bush |
| 18 | Replacement of Gland Sleeve |
| 19 | Replacement of body Neck ring gun metal |
| 20 | Replacement of Pump shaft stainless steel |
| 21 | Counter Plate stainless steel |
| 22 | Diffuser Packing |
| 23 | Impeller brazing machining and reboring |
| 24 | New Key way of impeller disc |
| 25 | Diffuser outer dia brazing and machining |
| 26 | Impellers outer dia brazing and machining |
| 27 | Disconnecting /unscrewing coupling for 75 HP , 60 HP pump set and seperating pump and motor, disconnecting all water connections from pump including suction and discharge pipe line and taking out the pump from base frame, transporting to workshop to carry out the necessary repairs and took back after repairs , installing on existing location ,making all the connections carefully, commissioning and testing at site to the entire satisfaction of the Engr-in-Charge. Note: (i) All the Spares/ parts/ job repairs required to be replaced shall be measured and paid seperately as under:-(ii) Machinery breakdown complaint to be attended within 12 Hrs and after repairing the same to be fixed and tested within 48 Hrs. |
| 28 | Coupling Set suitable for 75, 60 HP Pumping set |
| 29 | Replacement of gun metal impeller |
| 30 | Replacement of gun metal Bush |
| 31 | Replacement of Gland Sleeve |
| 32 | Replacement of body Neck ring gun metal |
| 33 | Replacement of Pump shaft stainless steel |
| 34 | Counter Plate stainless steel |
| 35 | Diffuser Packing |
| 36 | Impeller brazing machining and reboring |
| 37 | New Key way of impeller disc |
| 38 | Diffuser outer dia brazing and machining |
| 39 | Impellers outer dia brazing and machining |
| 40 | Supply and fixing in replacement of pressure gauge upto 100 Kg/sqcm and connected to pump set with and including syphon type pipe (as per existing sample), complete all as speciified and as directed.. |
| 41 | Supply and fixing in replacement of ball bearing 6314/6313, including replacement of old grease with new complete all as speciified and as directed.. |
| 42 | Supply and fixing in replacement of ball bearing 6319/6319-C3, including replacement of old grease with new complete all as speciified and as directed.. |
| 43 | Supply and fixing in replacement of roller bearing NU 306/307/309, including replacement of old grease with new complete all as speciified and as directed.. |
| 44 | Disconnecting existing electric motor and dismantling from foundation and transporting the same to the workshop for repairs and refixing the same on existing location after repair & making electric connection including testing and commissioning complete.The job including taking out burnt winding and rewinding the motor with super enamelled copper wires as per existing guage and size including super quality of varnish and insulating material as required for 220 HP, electric motor complete all as speciified and as directed..Note : Machinery breakdown complaint to be attended within 12 Hrs and after repairing the same to be fixed and tested within 48 Hrs. |
| 45 | Description all as per Serial item No. 8 above but of capacity 150 HP, motor complete all as speciified and as directed. |
| 46 | Description all as per Serial item No. 8 above but of capacity 125 HP, motor complete all as speciified and as directed. |
| 47 | Description all as per Serial item No. 8 above but of capacity 75 HP, motor complete all as speciified and as directed. |
| 48 | Description all as per Serial item No. 8 above but of capacity 60 HP, motor complete all as speciified and as directed. |
| 49 | Disconnecting /unscrewing Auto Transformer Starter Panel of capacity 125/150/ 220 HP, disconnecting all electric connections and carrying out necessary repair at site with replacement of parts as under complete all as specified including testing at site to the entire satisfaction of the Engr-in-Charge. Note: All the Spares/ parts/ job repairs required to be replaced shall be measured and paid as under: |
| 50 | Supply and fixing in replacement Electronic over current relay cap 0.5 – 60A 220V AC complete with arrangement for over current, phase reversal, under current and phase imbalance protection suitable for 150/250 HP ATS Panel complete all as speciified and as directed.. |
| 51 | Supply and fixing in replacement Three pole power contactor, AC Control, AC3 Rating 95A/ 47 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation incl taking out existing unsv power contactor complete all as speciified and as directed.. |
| 52 | Supply and fixing in replacement Three pole power contactor, AC Control, AC3 Rating 140A/ 75 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation incl taking out existing unsv power contactor complete all as speciified and as directed.. |
| 53 | Supply and fixing in replacement Three pole power contactor, AC Control, AC3 Rating 265A/ 140 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation incl taking out existing unsv power contactor complete all as speciified and as directed.. |
| 54 | Supply and fixing in replacement Three pole power contactor, AC Control, AC3 Rating 300A/ 160 KW, 415V complete with auxillary contact heavy duty suitable for pumping set operation incl taking out existing unsv power contactor complete all as speciified and as directed.. |
| 55 | Supply and fixing in replacement No volt coil complete all as speciified and as directed. |
| 56 | Supply and fixing in replacement Timer complete all as speciified and as directed. |
| 57 | Supply and fixing in replacement Digital voltmeter of size 96 x 96mm range 0 to 500 volts, 3 phase with in built in selector switch, suitable for CT operation - 01 set. all as speciified and as directed. |
| 58 | Supply and fixing in replacement Digital Ammeter range 0 to 400 Amps, 3 phase with iin built in selector switch, suitable for CT operation - 01 set. all as speciified and as directed. |
| 59 | Supply and fixing in replacement Indicator set R,Y,B 01 set of 3 pcs as per existing all as speciified and as directed. |
| 60 | Supply and fixing in replacement Selector switch as per existing all as speciified and as directed. Please Enable Macros to View BoQ information |
| 61 | Supply and fixing in replacement Selector switch as per existing all as speciified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender