Tender For Repair/Replacement And Maintenance Of Lt Cable, Joints, Pole, Lt Panels, Feeder Pillar Panel, Acb, Mccb And Other Connected Works For Western Area At Hisar Mil Stn Under Ge Hisar
Tender Value
45 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
20 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hisar → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement And Maintenance Of Lt Cable, Joints, Pole, Lt Panels, Feeder Pillar Panel, Acb, Mccb And Other Connected Works For Western Area At Hisar Mil Stn Under Ge Hisar
BOQ
| Sl. No. | Item Description |
| 1 | Taking out the old unserviceable LT underground cable 10 sqmm 2 core 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors from trenches/wall/floor/road/ culverts or pole etc complete all as specified and directed . Note : Excavation and earth work, duct work, GI pipe for laying of cable and sand cushing/cable protection covers etc are beyond the scope of this item and shall be measured & paid for separately |
| 2 | All as per item No 1.00 (here-in-before) but 16 Sqmm 4 core. |
| 3 | All as per item No 1.00 (here-in-before) but 25 Sqmm 3.5 core. |
| 4 | All as per item No 1.00 (here-in-before) but 35 Sqmm 3.5 core. |
| 5 | All as per item No 1.00 (here-in-before) but 50 Sqmm 3.5 core. |
| 6 | All as per item No 1.00 (here-in-before) but 70 Sqmm 3.5 core. |
| 7 | All as per item No 1.00 (here-in-before) but 95 Sqmm 3.5 core. |
| 8 | All as per item No 1.00 (here-in-before) but 120 Sqmm 3.5 core. |
| 9 | All as per item No 1.00 (here-in-before) but 185 Sqmm 3.5 core. |
| 10 | All as per item No 1.00 (here-in-before) but 240 Sqmm 3.5 core. |
| 11 | All as per item No 1.00 (here-in-before) but 300 Sqmm 3.5 core. |
| 12 | All as per item No 1.00 (here-in-before) but 400 Sqmm 3.5 core. |
| 13 | Laying only old serviceable LT underground cable , 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe of cable 10 sqmm to 50 Sqmm 2/3.5/4 core all as directed |
| 14 | All as per item No 13 (here-in-before) but size of cable 70 Sqmm to 185 Sqmm 3.5 core. |
| 15 | All as per item No 13 (here-in-before) but size of cable 240 Sqmm to 400 Sqmm 3.5 core. |
| 16 | Supply , laying, jointing, testing and commissioning of size 10 sqmm 2 core LT underground cable, 1100 volts grade, XLPE insulated and PVC sheathed, armoured heavy duty with multistrand aluminium conductors IS-7098, laid in trenches /fixed on wall /floor /road /culverts /pole or encased in GI pipe complete all as specified.Note : (i) All incoming and outgoing cable shall be connected by suitable size of thimples/legs. |
| 17 | All as per item No 16.00 (here-in-before) but 16 Sqmm 4 core. |
| 18 | All as per item No 16.00 (here-in-before) but 25 Sqmm 3.5 core. |
| 19 | All as per item No 16.00 (here-in-before) but 35 Sqmm 3.5 core. |
| 20 | All as per item No 16.00 (here-in-before) but 50 Sqmm 3.5 core. |
| 21 | All as per item No 16.00 (here-in-before) but 70 Sqmm 3.5 core. |
| 22 | All as per item No 16.00 (here-in-before) but 95 Sqmm 3.5 core. |
| 23 | All as per item No 16.00 (here-in-before) but 120 Sqmm 3.5 core. |
| 24 | All as per item No 16.00 (here-in-before) but 185 Sqmm 3.5 core. |
| 25 | All as per item No 16.00 (here-in-before) but 240 Sqmm 3.5 core. |
| 26 | All as per item No 16.00 (here-in-before) but 300 Sqmm 3.5 core. |
| 27 | All as per item No 16.00 (here-in-before) but 400 Sqmm 3.5 core. |
| 28 | Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth for laying cables, foundation for pole etc and getting out in soft/loose soil etc complete all as specified and as directed.Note : 1. The rate inclusive of taking down and refixing of any type of cheqered tiles, interlocking tiles complete as per existing for good make. 2. The PCC work shall be measured & paid for separately uner respective item of Sch 'A' / BOQ |
| 29 | M&L for sand cushioning 230mm thickness with dry sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punned down to 180mm after laying of cable in trenches for protection of cable complete all as directed.Note :- For the purpose of payment only punned thickness shall be measured. |
| 30 | Taking up bricks laid as cable covers and stacking serviceable brick for reuse at site etc complete all as specified and directed. |
| 31 | Laying only old bricks retrieved from item Srl Item No. 30.00 (here-in-before) as cable covers in trenches etc complete all as specified and directed. |
| 32 | M&L for brick covering to underground electric cable using sub class ‘B’ bricks, laid dry, flat, perpendicular to the direction of cable etc complete all as specified and directed. . |
| 33 | Returning filling in incl spreading leveling watering and well ramming in layers n. exc 25cm thick etc complete all as specified and as directed. |
| 34 | Removing excavated material to distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point etc complete all as specified and as directed. . |
| 35 | M&L for boring of hole under road/pavement/hard standing or any other situation by mannual means and suitable for passing of GI pipe 100 mm bore and making good both ends all specified and directed. |
| 36 | Supply and fixing in replacement 40 mm bore steel tube of light grade galvanised with all fittings fixed to walls / floors / poles or under road etc of following sizes complete all as specified and directed. |
| 37 | Supply and fixing in replacement 80 mm bore steel tube of light grade galvanised with all fittings fixed to walls / floors / poles or under road etc of following sizes complete all as specified and directed. |
| 38 | Disconnecting and taking out underground cable, including carry out megger testing of dismantle LT cable of length not more than 5 mtr and locating the fault and cutting the faulty damaged portion of cable, connecting with providing new heat shrinkable straight through jointing kit of cable size 25 to 50 Sqmm, 3.5/4 Core, including excavation, returning filling and all connected materials complete all as specified and directed.Note:- Necessary excavation, sand cushioning, cable cover as bricks etc beyond 5 mtr should be measured and paid separately. |
| 39 | All as per item sl No 38 above but cable size 70 to 150 Sqmm, 3.5 Core. |
| 40 | All as per item sl No 38 above but cable size 185 to 240 Sqmm, 3.5 Core. |
| 41 | All as per item sl No 38 above but cable size 300 to 400 Sqmm, 3.5 Core. Please Enable Macros to View BoQ information |
| 42 | All as per item sl No 38 above but cable size 300 to 400 Sqmm, 3.5 Core. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer