Educational and Research Institute Government Departments Closing in 19 days TDR #57798233

Tender For Supply, Installation, Testing, And Commissioning For The Renovation Of Chemical Laboratory On A Turnkey Basis (Civil, Electrical, And Modular Lab Furniture) At The Department Of Chemistry, Iit (Bhu), Varanasi.

Issued by Government Departments · Varanasi, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Oct 2026
19 days left
EMD
38000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Installation, Testing, And Commissioning For The Renovation Of Chemical Laboratory On A Turnkey Basis (Civil, Electrical, And Modular Lab Furniture) At The Department Of Chemistry, Iit (Bhu), Varanasi.

BOQ

Name of Work:- Supply, Installation, Testing, and Commissioning for the Renovation of Chemical Laboratory on a Turnkey Basis (Civil, Electrical, and Modular Lab Furniture) at the Department of Chemistry, IIT (BHU), Varanasi.
Sl. No. Item Description
1A. LABORATORY MODULAR FURNITURE
2PLINTH MUS (GI) — Centre Island BenchOverall size: 2709 + 1050 + 1580 + 1050 + 2709 mm (L) × 750/1050 mm (W) × 900 mm (H) • Worktop Material: 20 mm HPL (Trespa) — 80 sq ft; Position: Modular U-Shape; Type: WET • Material of Construction: 18–20G thick GI sheet; interior & exterior powder-coated finish (50–70 microns) • Storage: 600 mm one-drawer-two-shutter with one shelf (Qty 4); 1050 mm one-shutter (Qty 2); 750 mm one-drawer-two-shutter with one shelf (Qty 6) • Filler Panel (Qty 3) • Reagent Rack: single-side double-tier (Qty 3)• Electrical & LAN Module: 3M plate with 16/6A socket & 16A MCB/switch (Qty 6); CAT 6 Cable Ethernet Information Outlet with RJ45 Jack (Qty 2).• Sink, Tap & PEG Board: Polypropylene sink 560×355 (Qty 1); three-way swan-neck CPVC & brass faucet (Qty 1); Polypropylene PEG Board (Qty 1).• Hardware: SS304 soft-close hinges & channels; SS304 “D”-type drawer handles; all storage lockable
3PLINTH M-WALL (GI) — Wall-Side BenchOverall size: 2700 mm (L) × 750 mm (W) × 900 mm (H) • Worktop Material: 20 mm HPL (Trespa) — 22 sq ft; Position: Modular Wall; Type: DRY • Material of Construction: 18–20G thick GI sheet; powder-coated finish (50–70 microns) • Storage: 600 mm one-drawer-two-shutter with one shelf (Qty 2) • Leg Space: 600–900 mm (Qty 2)• Electrical & LAN Module: 3M plate with 16/6A socket & 16A MCB/switch (Qty 6); CAT 6 Cable Ethernet Information Outlet with RJ45 Jack (Qty 2).• Supporting Panel (Qty 1); Filler Panel (Qty 2) • Hardware: SS304 soft-close; SS304 “D”-type handles; lockable
4PLINTH M-WALL (GI) — Wall Bench (Extended)Overall size: 3680 mm (L) × 750 mm (W) × 900 mm (H) • Worktop Material: 20 mm HPL (Trespa) — 30 sq ft; Position: Modular Wall; Type: DRY • Material of Construction: 18–20G thick GI sheet; powder-coated finish (50–70 microns) • Storage: 600 mm one-drawer-two-shutter with one shelf (Qty 3) • Leg Space: 900–1200 mm (Qty 2)• Electrical & LAN Module: 3M plate with 16/6A socket & 16A MCB/switch (Qty 6); CAT 6 Cable Ethernet Information Outlet with RJ45 Jack (Qty 2).• Filler Panel (Qty 2) • Hardware: SS304 soft-close; SS304 “D”-type handles; lockable
5PIPE M-WALL (GI) — Pipe-Frame BenchOverall size: 2650 mm (L) × 600 mm (W) × 750 mm (H) • Worktop Material: 25 mm laminated HDHMR table top — 17 sq ft; Position: Modular Wall; Type: DRY • Assembly: pipe-frame structure, cross-section 38×38×1.2 mm CRCA; finish 50–60 microns powder-coated • Material of Construction: 18–20G thick GI sheet; powder-coated finish (50–70 microns) • Structure: 38 mm × 38 mm × 1.2 mm MS pipe (Qty 1)• Electrical & LAN Module: 3M plate with 16/6A socket & 16A MCB/switch (Qty 6); CAT 6 Cable Ethernet Information Outlet with RJ45 Jack (Qty 2).• Filler / cover panels as required
6PIPE M-WALL (GI) — Pipe-Frame BenchOverall size: 2030 mm (L) × 600 mm (W) × 750 mm (H) • Worktop Material: 25 mm laminated HDHMR table top — 13 sq ft; Position: Modular Wall; Type: DRY • Assembly: pipe-frame structure, cross-section 38×38×1.2 mm CRCA; finish 50–60 microns powder-coated • Material of Construction: 18–20G thick GI sheet; powder-coated finish (50–70 microns) • Structure: 38 mm × 38 mm × 1.2 mm MS pipe (Qty 1)• Electrical & LAN Module: 3M plate with 16/6A socket & 16A MCB/switch (Qty 6); CAT 6 Cable Ethernet Information Outlet with RJ45 Jack (Qty 2).
7Glass-Shutter Over Head Cabinet (GI)• Wall-mounted lockable storage cabinet made of epoxy powder-coated 20-gauge GI sheet • Toughened-glass front shutters with lock; internal adjustable shelving • Overall size: 600 mm W × 400 mm D × 600 mm H
8Laboratory Revolving Study Chair• Revolving study chair with castor wheels; powder-coated MS frame • Height-adjustable seat; suitable for laboratory use (equivalent to Godrej Interio or approved equivalent)
9Under-Desk Pedestal Storage Unit (2-Drawer, Lockable)Free-standing 2-drawer pedestal / chest of drawers• Material: engineered wood — particle board (primary & secondary); Color: White; Finish: Matte• Drawers: 2 box drawers on side-mount drawer slides; top drawer with secure key lock; modern C-handles• Mount: free-standing; Shape: rectangular; opening mechanism: handles• Overall size: 40 cm (W) × 45 cm (D) × 62.5 cm (H); approx. weight 10 kg• Suitable for office/study & storage of files, documents & personal items; DIY assembly; warranty 1 year (manufacturing defects)
10B. Civil Works
11Roller Blinds (Blackout)Providing & fixing blackout roller blinds with head rail; screen fabric (25% polyester / 75% PVC, zero openness, 410–465 g/sqm, 0.67 mm); fire-resistance NFPA 701; 38 mm OD anodised aluminium-alloy 6063-T6 tube with clutch mechanism; ball-chain control & powder-coated bottom rail; complete as per approved sample.
12Structural Steel WorkSteel work in built-up tubular (round/square/rectangular hollow) sections/trusses — hot-finished welded tubes; including cutting, hoisting, fixing in position, priming coat, welding & bolting with special washers; complete.
13Cement Plaster15 mm cement plaster on rough side of single/half brick wall, mix 1:6 (1 cement : 6 coarse sand); finished smooth & true to line and level.
14Synthetic Enamel PaintPainting with synthetic enamel paint of approved brand — two or more coats on new work to give an even shade.
15Wall PuttyProviding & applying white-cement-based putty of average 1 mm thickness over the plastered wall surface to prepare an even & smooth surface; complete.
16Acrylic Emulsion PaintWall painting with premium acrylic emulsion (interior grade, VOC < 50 g/l) of approved brand — two coats including additional coats to achieve even shade.
17PrimerApplying priming coat with water-thinnable cement primer (low-VOC, < 50 g/l) on wall surface — two coats.
18R.C.C. DemolitionDemolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 m lead, as directed.
19Dismantling Doors/WindowsDismantling doors, windows and clerestory windows (steel or wood) including chowkhats, architraves, holdfasts, etc. — of area 3 sq.m and below.
20Disposal of DebrisDisposal of building rubbish / malba / unserviceable dismantled material by mechanical means including loading, transporting & unloading to approved municipal dumping ground beyond 50 m initial lead, all lifts.
21Carpenter (Deployment)Supply of skilled carpenter for carpentry-related works, on daily deployment basis.
22Labour (Deployment)Supply of general labour for construction and allied finishing activities, on daily deployment basis.
23False CeilingProviding & fixing calcium-silicate false ceiling tiles 595×595 mm (per CPWD 2019) on interlocking hot-dipped galvanised T-grid (main-T 24×38 mm, cross-T 24×32 mm) suspended with GI hangers, wall angles & fasteners; complete in all respects.
24Plumbing WorkProviding complete plumbing work — GI pipe, PVC pipe, gate valve, 02 nos stop cock and 01 no SS grating etc., complete.
25uPVC Partition, Doors & WindowsuPVC partition & 2-track sliding window with 5 mm clear glass — casement outer frame AP201 (45×50 mm, 2.2 mm), 2-track sliding frame AP101 (60×52 mm, 2.2 mm), sliding sash AP114, mullion AP206, door sash AP205; 1.2–1.5 mm reinforcement; Mccoy hardware; 5 mm float glass; as per approved drawing (2 partitions, 4 windows, 3 doors, 2 wall-sections).
26Vitrified FlooringProviding & laying double-charge vitrified polished floor tiles 600×600 mm (water absorption < 0.08%, IS:15622) of approved brand on 20 mm cement mortar 1:4, jointing with grey cement slurry; zero-chipping diamond-cut, laid with leveling system; complete.
27Epoxy GroutingGrouting flooring tile joints (5 mm width) with epoxy grout mix (organic-coated filler, hardener & resin); filling, grouting & finishing complete as directed.
28Block-out Roller Blind (Cordless, Ready-Made Unit)Ready-made block-out roller blind, white, size 140 × 195 cm, or approved equivalent).• Function: 100% block-out fabric; cordless (child-safe) operation with soft-close mechanism• Material: top & bottom rail anodised aluminium; fabric 100% polyester (min. 90% recycled); inner fabric polyethylene; cover panel ABS plastic; bracket polycarbonate/ABS• Size: fabric width 140 cm, roller width 143.4 cm, length 195 cm (coverage ≈ 2.73 m² each); Color: White; Finish: matte• Wall/ceiling fixing devices suitable for the substrate (screws not included); draw rod as required; fabric cannot be cut; care: wipe clean with damp cloth
29C. Electrical Works
30SUB HEAD - I : IN-WALL WIRING
31Point Wiring (Group C)Wiring for light / fan / Air Conditioner / exhaust-fan / call-bell point with 1.5 sq.mm FRLS PVC-insulated copper single-core cable in surface/recessed medium-class PVC conduit, with modular switch, modular plate, GI box and earthing.
32Light/Power Plug WiringWiring for light/power plug with 2×4 sq.mm FRLS PVC copper single-core cable in medium-class PVC conduit along with 1×4 sq.mm loop-earth conductor.
33Sub-Main WiringCircuit / sub-main wiring 2×1.5 sq.mm + 1×1.5 sq.mm earth wire, FRLS copper single-core in surface/recessed PVC conduit.
34Sub-Main Wiring (Heavy)Circuit / sub-main wiring 4×10 sq.mm + 2×6 sq.mm earth wire, FRLS copper single-core in PVC conduit.
35Cable Drawing (4 sq.mm)Supplying & drawing 3×4 sq.mm FRLS PVC copper single-core cable in existing surface/recessed conduit / DLP trunking.
36Cable Drawing (1.5 sq.mm)Supplying & drawing 3×1.5 sq.mm FRLS PVC copper single-core cable in existing conduit / trunking.
37SUB HEAD - II : FITTING
386/16A Modular SocketGI box with modular plate & cover including 6-pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection & painting.
39Twin 3-pin SocketGI box with modular plate & cover including 2 nos 3-pin 5/6A modular socket outlet and 2 nos 5/6A modular switch, connections (non-residential).
40Ceiling Fan (1200 mm)SITC of 1200 mm sweep ceiling fan (Class B insulation, PF ≥ 0.9, service value ≥ 6.85 CMM/W, air delivery ≥ 215 CMM, IS:374-2019) with electronic regulator, down-rod, canopies, shackle kit & complete wiring.
41Exhaust Fan (250 mm)SITC of 250 mm ABS Body Exhaust Fan (PF ≥ 0.9, Color: White, air delivery ≥ 800 CMM, IS:374-2019).
42Fan RegulatorSupplying & fixing two-module stepped-type electronic fan regulator on existing modular plate, including connections.
43LED Panel (2'×2')SITC of 2'×2' surface/recess LED luminaire — min. 4200 lm, CCT > 6500 K, THD < 10%, ripple < 5%, efficacy ≥ 120 lm/W, PMMA diffuser with constant-current driver; wiring & earthing complete.
4425A Socket + SP MCBGI box with modular plate including 25A modular socket outlet and 25A modular SP MCB (C-curve), connections & painting.
45SUB HEAD - III : DISTRIBUTION BOARDS & ACCESSORIES
468-Way TPN DBSupplying & fixing 8-way (4+24) double-door TPN MCB distribution board, 415 V, CRCA sheet steel Grade-D, PU-gasketted, powder-coated, IEC 61439-3, with tinned copper busbar, neutral & earth bars, DIN bar & earthing (without MCBs/incomer).
4712-Way SPN DBSupplying & fixing 12-way SPN distribution board complete with enclosure and accessories.
4863A TP MCBSupplying & fixing 63A TP MCB, 10 kA, C-curve, in the existing MCB DB.
4963A TPN MCBSupplying & fixing 63A TPN MCB, 10 kA, C-curve, in the existing MCB DB.
50SP MCB (5–32A)Supplying & fixing 5A–32A SP MCB, 10 kA, C-curve, in the existing MCB DB.
51CAT 6 LAN CableSupplying & drawing UTP 4-pair CAT 6 LAN cable in existing surface/recessed steel/PVC conduit, as required.
5225A Modular Socket + SP MCBGI box with modular plate & cover including 25A modular socket outlet and 25A modular SP MCB (C-curve), connections & painting. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57798233
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-10-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Supply, Installation, Testing, And Commissioning For The Renovation Of Chemical Laboratory On A Turnkey Basis (Civil, Electrical, And Modular Lab Furniture) At The Department Of Chemistry, Iit (Bhu), Varanasi.
Basic Detail
Tender No IIT(BHU)/CHY/26-27/BKS-Lab/01
Bidding Type Tender
Location
City Varanasi
State Uttar Pradesh
Key Dates
Publish Date 30 Sep 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 1180
EMD 38000
Exemption Available
Document List
327451d6-122c-4ab1-81f4-fa998fe15a6c.html
BOQ_975669.xls
Tendernotice_1.pdf
Tender_Document_for_Lab_R_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

327451d6-122c-4ab1-81f4-fa998fe15a6c.html

xls

BOQ_975669.xls

pdf

Tendernotice_1.pdf

pdf

Tender_Document_for_Lab_R_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders