Tender for Annual Rate Contract For Commissioningof Various Sources Under Rigep Division Barmer
BOQ
| Sl. No. | Item Description |
| 1 | PHED BSR-2023 Revised Rate is exclusive of GST. |
| 2 | Providing & laying ISI marked GI Pipe Light duty ( “A” class) as per IS: 1239 for casing pipe for submersible cable external work 40 mm dia comRate is exclusive of GST.plete in all respect. |
| 3 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.Rate is exclusive of GST. |
| 4 | Up to 2.0 KW |
| 5 | Above 2.0 KW |
| 6 | Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.Rate is exclusive of GST. |
| 7 | Supply & Installation of 3 phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. Up to 5.5 KW (7.5 HP) & head up to 120 mtr.Rate is exclusive of GST. |
| 8 | Up to 5.5 KW (7.5 HP) & head above 120 mtr. |
| 9 | 7.5 KW (10 HP) & head up to 120 mtr. |
| 10 | 7.5 KW (10 HP) & head above 120 mtr. |
| 11 | 9.3 KW (12.5 HP) & head up to 120 mtr. |
| 12 | 9.3 KW (12.5 HP) & head above 120 mtr. |
| 13 | 11 KW (15 HP) & head up to 120 mtr. |
| 14 | 11 KW (15 HP) & head above 120 mtr. |
| 15 | 13 KW (17.5 HP) & head up to 120 mtr. |
| 16 | 13 KW (17.5 HP) & head above 120 mtr. |
| 17 | 15 KW (20 HP) and above, head up to 120 mtr. |
| 18 | 15 KW (20 HP) and above, head above 120 mtr. |
| 19 | SITC of Digital Type Single Phase DOL Starter Electrical Control Feeder Panel, 63A, suitable for operation of Single-phase pump set on 215V AC supply, comprising input MCB (DP 63A.), GFU with auxiliary contact for earth fault protection, AC-3 duty PMC based DC contactors 50 Amp. 1P (DOL type), Microprocessor basedDigital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal, connectors, complete internal wiring with copper conductors (for control and power), capacitor bank and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all res ects as er s ecification and direction of Engineer-in-Charge. Upto 5 HP (Single Phase) |
| 20 | SITC of Digital Type DOL Starter Electrical Control Feeder Panel, 40A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input MCB (40Amp. FP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (f DOL and APSC type),Microprocessorbased Digital MotorProtection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications,Heavy Duty terminal, connectors, complete internal wiring with copper conductors (forcontrol and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge upto 5 HP (DOL Type) |
| 21 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 32Amp. AC-3 duty PMC based DC contactors (For Star and Main), 40Amp. 1 Pole Contactor for APSC, 22Amp. Contactor for DeIta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Above 5 HP and up to 10 HP (Star Delta type) |
| 22 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 35Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 25Amp. Contactor for DeIta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Above 10 HP and up to 15 HP (Star Delta type) |
| 23 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 100A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 100Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 40Amp. AC-3 duty PMC based DC contactors (For Star and Main), 45Amp. 1 Pole Contactor for APSC, 32Amp. Contactor for DeIta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 7 kVAR, and all necessaryhardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indication and automation features requied for safe efficient and reliable operation of pump sets under varying fiedl conditions, complete in all respects as per specification and direction of Engineer-in-Charge Above 15 HP and up to 20 HP (Star Delta type) |
| 24 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 415V AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 45 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 50 Amp. 1 Pole Contactor for APSC, 40 Amp. Contactor for DeIta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 8.3 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of En ineer-in-Charge. Above 20 HP and up to 25 HP (Star Delta type) |
| 25 | SITC of Digital Type Star Delta Starter Electrical Control Feeder Panel, 125A, suitable for operation of 3-phase pump set on 41SV AC supply, comprising input 125Amp. MCCB (TP), GFU with auxiliary contact for earth fault protection, 63 Amp. AC-3 duty PMC based DC contactors (For Star and Main), 80 Amp. 1 Pole Contactor for APSC, 50 Amp. Contactor for DeIta,Microprocessor based Digital Motor Protection Unit with necessary protections, RTC timer, MCBs for power and control circuits, LED indications, Heavy duty terminal connectors, complete internal wiring with copper conductors (for control and power), capacitor bank of 12.5 kVAR, and all necessary hardware.The panel shall be housed in outdoor type fabricated GI enclosure of 1.6 mm thickness, Complete with all standard protections, indications and automation features required for safe, efficient and reliable operation of pump sets under varying field conditions, complete in all respects as per specification and direction of Engineer-in-Charge. Above 25 HP and up to 30 HP (Star Delta type) |
| 26 | Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay, ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM). All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be of minimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18\\" and double door including in built locking system. The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. Above 5 HP and up to 10 HPRate is exclusive of GST. |
| 27 | Above 10 HP and up to 15 HP |
| 28 | Above 15 HP and upto 20 HP |
| 29 | Above 20 HP and upto 30 HP |
| 30 | Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc. 3 core 4.0 Sq.mmRate is exclusive of GST. |
| 31 | 3 core 6.0 Sq.mm |
| 32 | 3 core 10.0 Sq.mm |
| 33 | 3 core 16.0 Sq.mm |
| 34 | Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 10.0 Sq.mm, 4 core Rate is exclusive of GST. |
| 35 | 16.0 Sq.mm, 4 core |
| 36 | 25.0 Sq.mm, 3.5 core |
| 37 | 35.0 Sq.mm, 3.5 core |
| 38 | Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required. Rate is exclusive of GST. |
| 39 | Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc for holding the riser pipe assembly of submersible pump set.Rate is exclusive of GST. |
| 40 | Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2\\" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 125 mm diaRate is exclusive of GST. |
| 41 | 150 mm dia |
| 42 | 200 mm dia |
| 43 | 250 mm dia |
| 44 | Providing & Lowering in tube well ISI marked GI Pipe medium duty (“B\\" class), Steel tube as per IS:1239 or amended up to date and zinc coating as per IS 4736, threaded and double flanged (welded) on both ends and two number 25x3mm MS flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. Rate is exclusive of GST. |
| 45 | 50 mm dia |
| 46 | 65 mm dia |
| 47 | 80mm dia |
| 48 | Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. 40 mm diaRate is exclusive of GST. |
| 49 | 50 mm dia |
| 50 | 63 mm dia |
| 51 | 75 mm dia |
| 52 | 90 mm dia |
| 53 | Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.Rate is exclusive of GST. |
| 54 | Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes Rate is exclusive of GST.65 mm dia |
| 55 | 80 mm dia |
| 56 | Proving and Fixing 32 mm dia Full way valve or wheel valve as per IS:778 or amended up to date of approved make, on pump delivery pipe.Rate is exclusive of GST. |
| 57 | Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg. including all jointing material as per specification with safety cover.Rate is exclusive of GST. |
| 58 | Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves straight and pocket less body passage of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - AISI- 410 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel Insertion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Rate is exclusive of GST. |
| 59 | Manually Operated CI Sluice valve of Class PN-1.0 |
| 60 | 80 mm HW |
| 61 | 100 mm HW |
| 62 | 125 mm HW |
| 63 | 150 mm HW |
| 64 | 200 mm HW |
| 65 | Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.Plain ended CI specials including tail piece, spigot end and socket end.Rate is exclusive of GST. |
| 66 | Up to 300 mm dia |
| 67 | Above 300 mm and up to 600 mm dia |
| 68 | Double flanged CI pipe fittings. |
| 69 | Up to 300 mm dia |
| 70 | Above 300 mm and up to 600 mm dia |
| 71 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)Rate is exclusive of GST. |
| 72 | MS pipe specials above 600mm dia(with minimum 6.3mm thickness sheet) |
| 73 | Providing and Fixing of ISI marked PVC storage tank of following capacity as per IS: 12701-1989 (of approved make) with cover, 25 mm dia. 1 mtr long GI overflow pipe, 25 cm long 25 mm dia washout GI pipe with plug & socket, including P&F 32 mm dia Ball Cock (Float valve) IS 1703 marked with rod and PVC ball complete with brass weight 1000 gm, including P&F 15mm dia CI quarter turn heavy duty Bib Cocks four no's of superior quality and approved make, including interconnections complete job.1000 litres capacityRate is exclusive of GST. |
| 74 | 2000 litres capacity |
| 75 | Fabrication & Fixing M.S. Stand of specified class of angle iron L-shaped of 50 mm size with four legs grouted by 300*300*300 mm CC Block M-15 in the ground and all legs tied up with each other through same size of angle iron along with cross bars to support the bottom of 1000 Ltr./ 2000 Ltr. PVC tank complete in all respect.Rate is exclusive of GST. |
| 76 | 6.8 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanised rubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367 (Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.0/1.6 Rate is exclusive of GST. |
| 77 | 80 mm dia |
| 78 | 100 mm dia |
| 79 | 125 mm dia |
| 80 | 150 mm dia |
| 81 | 200 mm dia Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender