Tender For Periodical Servicing And Maintenance Of Fire Alarm/Fire Fighting System Alongwith Connected Items At Chandigarh And Tbrl Range Ramgarh
Tender Overview
Project Description
Tender for Periodical Servicing And Maintenance Of Fire Alarm/Fire Fighting System Alongwith Connected Items At Chandigarh And Tbrl Range Ramgarh
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 22-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 29-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Testing / servicing / comprehensive maintenance and repair including renewal/ replacement of defective parts of all existing fire protection system complete of following fire protection system installed at various location once in a month for 100% serviceability of the complete including checking of fire detectors, cleaning of detector by removing dust or dirt, cleaning of heavy greasy deposit if any, checking the connection of batteries, specific gravity of electrolyte, wiring connection of detectors/hooter/response indicator and the alarm function of control panel and indicating eqpt be checked by the operation of trigger device of the fire alarm system installed in the following buildings and replacing the defective / unserviceable parts complete all as specified and directed.NOTE:- (i) Cost of new components/parts shall be paid for separately under relevant item of Schedule 'A' as suply only(ii) Contractor's rep shall visit minimum once in a month to every panel and take serviceability certificate duly signed by the users. Additional visit as and when required shall not be paid as extra.Fire Alarm Panels conventional type with PA system installed in HQ SASE Him Parisar Bldg Sec 37A Chandigarh. |
| 2 | All as per item No. 01 above fire alarm system Addressable type but for Plot - 2 bldg, Sec 37- A chandigarh |
| 3 | All as per item No. 01 above fire alarm system conventional type but for Director bldg,Library Sec and AC plant at Zone - I,TBRL Range Ramgarh complete all as specified and directed. |
| 4 | All as per item No. 01 above fire alarm system conventional type but for Telephone Exchange bldg at Zone - I,TBRL Range Ramgarh complete all as specified and directed. |
| 5 | All as per item No. 01 above fire alarm system conventional type but for C & IT bldg at Zone - I, TBRL Range Ramgarh complete all as specified and directed. |
| 6 | All as per item No. 01 above fire alarm system conventional type but for Auditorium bldg at Zone - I, TBRL Range Ramgarh complete all as specified and directed. |
| 7 | All as per item No. 01 above fire alarm system conventional type but for VAJRA bldg at Zone - I, TBRL Range Ramgarh complete all as specified and directed. |
| 8 | All as per item No. 01 above fire alarm system conventional type but for B-15 bldg at Zone - III,TBRL Range Ramgarh complete all as specified and directed. |
| 9 | All as per item No. 01 above fire alarm system conventional type but for Data Analysis centre at Zone - III,TBRL Range Ramgarh complete all as specified and directed. |
| 10 | All as per item No. 01 above fire alarm system conventional type but for control room at Zone - VI, TBRL Range Ramgarh complete all as specified and directed. |
| 11 | All as per item No. 01 above fire alarm system conventional type but for control room at Zone - VII, TBRL Range Ramgarh complete all as specified and directed. |
| 12 | All as per item No. 01 above fire alarm system conventional type but for HMX Plant Bldg at Zone - II, TBRL Range Ramgarh complete all as specified and directed. |
| 13 | All as per item No. 01 above fire alarm system conventional type but for PBX Plant Bldg at Zone - II, TBRL Range Ramgarh complete all as specified and directed. |
| 14 | All as per item No. 01 above fire alarm system conventional type but for OCTAL Plant and Press Bldg at Zone - II, TBRL Range Ramgarh complete all as specified and directed. |
| 15 | All as per item No. 01 above fire alarm system conventional type but for control room Bldg at Zone - V, TBRL Range Ramgarh complete all as specified and directed. |
| 16 | All as per item No. 01 above fire alarm system Addressablel type but for ESS test facilty at TBRL Range Ramgarh complete all as specified and directed. |
| 17 | All as per item No. 01 above fire alarm system Addressablel type but for EMI test facilty at TBRL Range Ramgarh complete all as specified and directed. |
| 18 | All as per item No. 01 above fire alarm system Addressablel type but for CADS Bldg at TBRL Range Ramgarh complete all as specified and directed. |
| 19 | All as per item No. 01 above fire alarm system Addressablel type but for Pulse Radiography Bldg at Zone - IV, TBRL Range Ramgarh complete all as specified and directed. |
| 20 | All as per item No. 01 above fire alarm system Addressablel type but for Tellic Bldg at Zone -VIII, TBRL Range Ramgarh complete all as specified and directed. |
| 21 | Supply only conventional fire alarm panel of 02 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed. |
| 22 | Supply only conventional fire alarm panel of 04 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed. |
| 23 | Supply only conventional fire alarm panel of 06 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed. |
| 24 | Supply only conventional fire alarm panel of 08 zones with LCD display facility and advanced micro controller based circuit complete all as specified and directed. |
| 25 | Supply only smoke detector conventional type (Ceiling mounted) with base, Ionization type dual chamber as per approved specification. The smoke detector should be matchable with existing system in the building complete all as specified and directed. |
| 26 | Supply only heat detector conventional type with base Ionization type dual chamber as per approved specification. The heat detector should be matchable with existing system in the building complete all as specified and directed. |
| 27 | Supply only wall mounted fire alarm manual call point conventional type complete all as specified and directed. |
| 28 | Supply only fire alarm hooter for conventional fire alarm system operated on 100V AC/ 24V DC with suitable audible range 80DB complete all as specified and directed. |
| 29 | Suppply only response indicator LED type complete all as specified and directed. |
| 30 | Supply only lead acid battery 12 volts 7 AH suitable for conventional fire alarm panel complete all as specified and directed. |
| 31 | Taking down fire extinguisher cylinder from the fire stand/wall and refilling of Gas cylinder with multi purpose dry powder suitable for class ABC, cylinder capacity 2 Kg including hydraulic pressure testing of cylinder. |
| 32 | Taking down fire extinguisher cylinder from the fire stand/wall and refilling of Gas cylinder with multi purpose dry powder suitable for class ABC, cylinder capacity 6 Kg including hydraulic pressure testing of cylinder. |
| 33 | Taking down fire extinguisher cylinder from the fire stand/wall and refilling of Gas cylinder with multi purpose dry powder suitable for class ABC, cylinder capacity 9 Kg including hydraulic pressure testing of cylinder. |
| 34 | Supply and fixing portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of Fire class A,B, C and bulk range discharge two metre minimum and Capacity 02 Kg ISI marked complete all as specified and directed. |
| 35 | Supply and fixing portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of Fire class A,B, C and bulk range discharge two metre minimum and Capacity 06 Kg ISI marked complete all as specified and directed. |
| 36 | Supply and fixing portable fire extinguisher cylinder filled with mono ammonium phosphate dry powder MAP90 suitable for all types of Fire class A,B, C and bulk range discharge two metre minimum and Capacity 09 Kg ISI marked complete all as specified and directed. |
| 37 | Supply only smoke detector addressable type (Ceiling mounted) with base, Ionization type dual chamber as per approved specification. The smoke detector should be matchable with existing system in the building complete all as specified and directed. |
| 38 | Supply only heat detector addressable type with base Ionization type dual chamber as per approved specification. The heat detector should be matchable with existing system in the building complete all as specified and directed. |
| 39 | Supply only wall mounted fire alarm manual call point addressable type complete all as specified and directed. |
| 40 | Supply only fire alarm hooter for addressable fire alarm system operated on 100V AC/ 24V DC with suitable audible range 80DB complete all as specified and directed. |
| 41 | Material and labour for sub main wiring alongwith earth wire of size 2x1.5 Sqmm+1x1.5 Sqmm earth wire (FRLSH) pvc insulated copper conductor, single core, 1100 v grade cable in surface / recessed in steel conduit as required complete all as specified and directed. |
| 42 | Supply and fixing in replacement wall mounted speaker 6 watt of PA system all as specified and directed. |
| 43 | Supply and fixing in replacement wall mounted speaker 10 watt of PA system all as specified and directed. |
| 44 | Supply and fixing LCM suitable for notifier fire alarm panel model NFS 3030 complete all as specified and directed. |
| 45 | Supply and fixing LEM suitable for notifier fire alarm panel model NFS 3030 complete all as specified and directed. |
| 46 | Supply and fixing loop card suitable for morley zx fire alarm panel complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender