Tender For Repair To Shed With Iron Work, Drainage System With Ms Grills, Security Wall, Fencing And Certain Misc Works At Lrde, Cair & Mes Premises Under Ge(I) R &D (West) Bengaluru.
Tender Overview
Project Description
Tender for Repair To Shed With Iron Work, Drainage System With Ms Grills, Security Wall, Fencing And Certain Misc Works At Lrde, Cair & Mes Premises Under Ge(I) R &D (West) Bengaluru.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 28-Oct-2026 |
| 2 | 28-Oct-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 02-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE OF WORKS |
| 2 | Dismantling of plain or corrugated steel sheeting ,any gauge,thickness ,including Nainital or similar patteren roof coverings etc complete all as specified and as directed by Engr-in-Charge. |
| 3 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet(approved profile) 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed by Engr-in-Charge. |
| 4 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws as specified complete all specified and as directed by Engr-in-Charge. |
| 5 | S&F Steel work in tubular trusses including special shaped washer, posts etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc complete all as specified and directed. |
| 6 | Dismantling framed steel trusses, span not exc 10 Metres complete all as specified and as directed by Engr-in-Charge. |
| 7 | M&L for preparation of new steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome complete all as specified and directed. |
| 8 | Demolition of brick work or stone/ boulder masonry, PCC block masonry built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish outside MD land etc complete all as specified and directed. |
| 9 | M&L for Precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 etc complete all as specified and directed. |
| 10 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finishing the surface even and smooth (without using extra cement) complete all as specified and directed. |
| 11 | Taking down cement plaster on brick or stone wall etc incl raking out joints hacking for key scrubbing down with water complete all as specifed and directed. |
| 12 | S&F steel work as in Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks & similar work conforming to Fe 290-0 Gde E-165 complete all as specified and directed. |
| 13 | Dismantling post or struts (wood,Steel or RCC) any section ,including taking out embedded portion(concrete or RCC) and making good distrubed ground complete all as specified and as directed by Engr-in-Charge. |
| 14 | S&F mild steel as in posts and struts in fencing including cutting tops to shape as directed, purlin etc. ,drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc complete all as specified and directed. |
| 15 | Fixing only steel as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work using dismantled steel sections etc complete all as specified and directed. |
| 16 | Dismantling of chain link MS galvanised fencing of any size and type complete all as specified and directed. |
| 17 | Supply only for chain link MS galvanised fencing of mesh size and type complete all as specified and directed. |
| 18 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire |
| 19 | S&F in repairs CONSEC ZAL super razor punch barb tape (SRPBT) aluminium base helix coil in security fencing with and include necessary GI fitting clips for securing, with following specification : (i) Dia of coil (unstreched-600mm) (ii) No of circle - 51 turns per coil (iii) weight of each coil with hessian pack 8.5 kg (iv) coverage per coil- 8 RM (v) central core wire : made from 2.6 mm dia GI H.T.SS wire as per IS-4454 galvanised as per IS- 2629 (vi) Razor punched strip: - razor punched tape is CONSECZAL steel comprising of AL base with Zinc alloy @ 150gm/M2 confirming to ASTM-729/A-729M with additional primer treatment of epoxy/Polyrethane & final paint top coat of caulified green shade (BSL 139) by Hot dipping process complete all as specified and as directed. |
| 20 | Taking down and restraining resecuring existing CONSECZAL super razor punch barb tape (SRPBT) aluminium base helix coil in security fencing with and include necessary GI fitting clips for securing, with following specification : (i) Dia of coil (unstreched-600mm) (ii) No of circle - 51 turns per coil (iii) weight of each coil with hessian pack 8.5 kg (iv) coverage per coil- 8 RM (v) central core wire : made from 2.6 mm dia GI H.T.SS wire as per IS-4454 galvanised as per IS- 2629 (vi) Razor punched strip: - razor punched tape is CONSECZAL steel comprising of AL base with Zinc alloy @ 150gm/M2 confirming to ASTM-729/A-729M with additional primer treatment of epoxy/Polyrethane & final paint top coat of caulified green shade (BSL 139) by Hot dipping process complete all as specified and as directed. |
| 21 | M&L for preparation of old steel surfaces of any description and applying one coat of synthetic enamel paint on steel surface over 10cm girth or width, not otherwise described complete all as specified and directed. |
| 22 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 23 | Taking down and restraining resecuring including making good staples etc of existing Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, making good or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 24 | Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish outside MD land etc complete all as specified and directed. |
| 25 | M&L for RCC type B1 1:2:4(using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and directed by Engr-in-Charge. |
| 26 | M&L for RCC type B1 1:2:4(using 20mm graded aggregate)as in beams, plinth beams etc including necessary formwork complete all as specified and directed by Engr-in-Charge. |
| 27 | M&L for RCC type B1 1:2:4(using 20mm graded aggregate)as in Columns, pillars, piers, posts and struts including necessary formwork complete all as specified and directed by Engr-in-Charge. |
| 28 | M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregates) as in walls or columns,pillars and posts(including caps and bases and also shuttering arrangement for casting) etc complete all as specified and directed. |
| 29 | Demolition of un-reinforced cement concrete in ground floors and pavings any thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M complete all as specified and as directed by the Engineer in Charge. |
| 30 | M&L for rubber moulded Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed & pointed in neat cement slurry in floors with grey cement & pigment over and including 15mm thick screed bed or bedding layers in CM 1:4 for laying floor finishes complete all as specified and directed. |
| 31 | M&L for PCC (1:4:8) typeD-2 ,using 40mm graded stone aggregate as in foundations,filling and mass concrete complete all as specified and directed. |
| 32 | M&L for 100 mm thick PCC (1:2:4) type B-2, using 40mm graded stone aggregate as in hard standing complete all as specified and directed. |
| 33 | Demolition of Stone slabs & tiles of any description or thickness in floors, aprons etc. laid dry or laid ,bedded and pointed over mortar and removal of debris outside MD land etc complete all as specified and directed. |
| 34 | M&L for rubber moulded Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M - 35 Grade with grey cement and no pigment etc complete all as specified and directed. |
| 35 | M&L for Sand cushion under floors for laying of interlocking tiles or in foundation including watering & consolidation complete all as specified and directed. |
| 36 | M&L for Plain Cement Concrete 1:2:4 Type B0 (using 12.5 mm graded stone aggregate) copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work etc complete all as specified and directed. |
| 37 | Dismantling of single layer Mangalore pattern or similar tiles in roofing complete all as specified and as directed by Engr-in-Charge. |
| 38 | Dismantling of Mangalore pattern roofing tiles with ceiling tiles or slate roofing bedded in cement mortar complete all as specified and as directed by Engr-in-Charge. |
| 39 | M&L for roof tiles Mangalore patteren interlocking at side joints laid complete on dry or sceed complete all as specified and as directed. |
| 40 | M&L for ceiling tiles for mangalore patteren tile roofing,laid dry complete all as specified and as directed by Engr-in-Charge. |
| 41 | M&L for ridge or hip tiles to suit mangalore patteren of roofing tiles,bedded and jointed in cement mortar CM1:6 with water proffing sealing compound complete all as specified and as directed by Engr-in-Charge. |
| 42 | M&L for applying of two coats of cement base paint over one coat of primer on new plastered surface complete all as specified and as directed by Engr-in-Charge. |
| 43 | Excavating in post holes (or similar holes) each n.exc 0.5 cum ,getting out hard/dense soil,returning filling in and ramming earth or broken rubble mixed with earth arround ,in layers not excceeding 25cm including removal etc complete all as specified and as directed by Engr-in-Charge |
| 44 | Cleaning of septic tank/soakage pit of any description by mechanically, of any size and depth including lifting up ad removing sludge along with sewage water not less than 3000Kg/Load including accumulated solid/semi solid sludge and any other foreign material by using vehicle KAMBI 6 LCN mounted with compressor and sucker tank of M/s Kam-avida enviro Engineers Pvt Ltd Pune or similar model vehicle and washing down with water for smooth functioning including disposal outside MD land complete all as specified and directed. |
| 45 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 ltrs suction capacity and 6000 ltrs water jetting tank capacity including skilled operator supervising engineer etc for cleaning and partial desilting of manholes and dechocking and flushing of sewer lines from one manhole to another by pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm, complete all as specified and directed |
| 46 | M&L for Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 3 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender