Tender For Provision Of A Partition Wall Inside The P.P. Store Office, Dismantling Of An Unused Iron Ladder On The First Floor Of The 6Th Unit Reserve Gear Building (Cescon Building) Inside Dpl Plant Premises, And Renovation Of Glazing Works At The W
Tender Overview
Project Description
Tender for Provision Of A Partition Wall Inside The P.P. Store Office, Dismantling Of An Unused Iron Ladder On The First Floor Of The 6Th Unit Reserve Gear Building (Cescon Building) Inside Dpl Plant Premises, And Renovation Of Glazing Works At The Wagon Tippler Control Room At Dpps, Dpl (Job No. 1005/Dpps)
BOQ
| Sl. No. | Item Description |
| 1 | (A) Partition of commercial ply as per design fitted and fixed complete (excluding the supporting framework but including necessary teak wood battens of size 40mmx 25 mm): In Ground Floor (ii) 6mm thick. |
| 2 | Dressed wood work in post, plate, battens etc. fitted & fixed complete (excluding the cost of bolts only, but including the cost of nails, screws etc.) (The quantum should be corrected upto three decimals) (i) Sal: Local. |
| 3 | 250 mm thick Brick work with Fly Ash Bricks (250 mm x 125 mm x 75 mm) as per IS 12894:2002 in cement mortar (1:4). a) In superstructure, ground floor. |
| 4 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). (i) With 1:6 cement mortar. (b) 15 mm thick plaster. |
| 5 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well-seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. b) 32 mm thick shutters (single leaf). |
| 6 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 7 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : a) On timber or plastered surface :With other than hi-gloss of approved quality. iv) Two coats (with any shade except white). |
| 8 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or concrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor). (a) One Coat i) Water based interior grade Acrylic Primer. |
| 9 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothening of surface. Two Coats. |
| 10 | Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia. rod with centre bolt and round fitting. (c) 300mm long. |
| 11 | Anodised aluminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod). (iii) 100 mm grip x 12 mm dia. Rod. |
| 12 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (vi) 100mm. X 50mm. X 1.25mm. |
| 13 | Labour for lowering and stacking after dismantling in parts R.S. joists, channels, angles, tees, plates etc. complete as directed. |
| 14 | Cutting to requisite length or shape departmental R.S. joists, channels, angles, tees, plates etc. |
| 15 | Loading in to trucks at the lifting point, unloading at destination, stacking properly in go downs or yard etc. as directed including carriage by head load up to a lead of 50.00 m at each of the two points. (h) Steel (Extra carriage for addl. 50 m or part thereof)(for total distance 250.00 mtrs.). |
| 16 | Carriage of Steel materials over pucca road. |
| 17 | Supplying, fitting & fixing of Aluminium fixed partion wall of all aluminium sections viz top, bottom and side member, intermediate member, glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, anodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gasket, cleat, angle screws etc. including labour charges for fitting and fixing of aluminium fixed partition wall with glass / panel board all complete as per architectural drawings and direction of Engineer-in-charge. (Excluding cost of glass/ panel board, 10-12 Micron thickness Anodizing film. Natural white. a) for unsupported length of vertical member upto 1.50m. height of both ends of vertical member restrained but panel within 0.90 sqm. |
| 18 | Supplying, fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top, bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, anodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Anodizing film Natural white. |
| 19 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; (A) clear, toughened glass conforming to IS: 2553-1992 (part-II) (i) 6 mm thick. |
| 20 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & re-fixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately. (b) Above area 2.5 Sq.m. |
| 21 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia. bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia. bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in charge. at 7.00 m high. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender