Power Government Departments Closing in 8 days TDR #57794617

Tender For Construction Work 220 Kv D/C Lohawat- Badi Sid Line At 220 Kv Gss Lohawat - 65 Kms. On Turnkey Basis Under Bid Enquiry No. Rvpn/Ehv/Bn-9019002612

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
136.59 Crore
Estimated cost
Bid Submission
19 Nov 2026
8 days left
EMD
2.74 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Work 220 Kv D/C Lohawat- Badi Sid Line At 220 Kv Gss Lohawat - 65 Kms. On Turnkey Basis Under Bid Enquiry No. Rvpn/Ehv/Bn-9019002612

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 03-Nov-2026 NIB_Date_Extn_Lohawat Lines_9019002612 Date 19-Nov-2026

BOQ

Name of Work:- Construction work 220 KV D/C LOHAWAT- BADI SID LINE AT 220 KV GSS LOHAWAT - 65 KMS. on Turnkey basis UNDER BID ENQUIRY NO. RVPN/EHV/BN-9019002612
Sl. No. Item Description
1Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
2High Tensile Steel
3Mild Steel
4Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
5Supply of Earthing material of Towers
6Pipe Type Set
7Counter Poise Earthing set
8Supply of following Tower Accessories
9Danger Plate
10Number Plate
11Phase Plate (Set of three)
12Design, manufacture and supply of following line material. **
13Disc Insulator - 70 kN
14Porcelein Long Rod Insulators 70 kN
15Disc Insulator - 120 kN
16Porcelein Long Rod Insulators 120 kN
17HTLS Conductor equivalent to ACSR Zebra Conductor
18Hardware Fittings for HTLS equivalent to Zebra Conductor
19Single Suspension H/W fittings with Preformed Armour Rod for HTLS equivalent to Zebra Conductor
20Single Tension H/W fittings for HTLS equivalent to Zebra Conductor
21Double Suspension H/W fittings with Preformed Armour Rod for HTLS equivalent to Zebra Conductor
22Double Tension H/W fittings for HTLS equivalent to Zebra Conductor
23Single suspension H/W fittings for pilot string HTLS equivalent to Zebra Conductor
24Accessories for HTLS equivalent to Zebra Conductor
25Mid Span Compression Joint for HTLS equivalent to Zebra Conductor
26Repair Sleeve for HTLS equivalent to Zebra Conductor
27Vibration Damper for HTLS equivalent to Zebra Conductor
28OPGW Cable
2948 Fibre (DWSM) OPGW fibre optic cable
30Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box*
31Joint box (48 Fibre)
32BIRD FLIGHT DIVERTER
33NON LED TYPE BIRD FLIGHT DIVERTER
34LED TYPE BIRD FLIGHT DIVERTER
35Any Other item required for successful completion of work
36Note: *One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW. ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
37Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
38Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
39Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
40(i) Any soil, soft rock other than hard rock
41(ii) Hard Rock (with blasting subject to permission or without blasting)
42SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
43(i) Tower including extension upto 9 Meter
44CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
45(i) 1:3:6 Mix (M-10)
46(iii) 1:1.5:3 Mix (M-20)
47STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
48EARTHING:
49(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
50(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm l.
51ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
52Erection of tower (with extension upto 9 Meters)
53Erection of HTLS equivalent to Zebra Conductor with associate hardware and accessories as per technical specification
54Installation of OPGW cable & Accessories
55Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
56Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
57Joint box (48 Fibre)
58Revitment work
59(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
60(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
61(C )Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
62(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
63Land Compensation
64Identifcation of land and preparation of land compensation case
65Documentation of preparation of case of land compensation
66BIRD FLIGHT DIVERTER
67INSTALLATION OF NON LED TYPE BIRD FLIGHT DIVERTER
68INSTALLATION OF LED TYPE BIRD FLIGHT DIVERTER
69Any Other Item
70Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
71High Tensile Steel
72Mild Steel
73Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
74Supply of Earthing material of Towers
75Pipe Type Set
76Counter Poise Earthing set
77Supply of following Tower Accessories
78Danger Plate
79Number Plate
80Phase Plate (Set of three)
81Design, manufacture and supply of following line material. **
82Disc Insulator - 70 kN
83Porcelein Long Rod Insulators 70 kN
84Disc Insulator - 120 kN
85Porcelein Long Rod Insulators 120 kN
86Hardware Fittings for ACSR Zebra Conductor
87Single Suspension H/W fittings for ACSR Zebra Conductor
88Single Tension H/W fittings for ACSR Zebra Conductor
89Double Suspension H/W fittings for ACSR Zebra Conductor
90Double Tension H/W fittings for ACSR Zebra Conductor
91Accessories for ACSR Zebra Conductor
92Mid Span Compression Joint for ACSR Zebra Conductor
93Repair Sleeve for ACSR Zebra Conductor
94Preformed Armour Rod for ACSR Zebra Conductor
95Vibration Damper for ACSR Zebra Conductor
96OPGW Cable
9748 Fibre (DWSM) OPGW fibre optic cable
98Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box*
99Joint box (48 Fibre)
100BIRD FLIGHT DIVERTER
101NON LED TYPE BIRD FLIGHT DIVERTER
102LED TYPE BIRD FLIGHT DIVERTER
103Any Other item required for successful completion of work
104Note: *One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW. ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
105Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
106Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
107Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
108(i) Any soil, soft rock other than hard rock
109(ii) Hard Rock (with blasting subject to permission or without blasting)
110SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
111(i) Tower including extension upto 9 Meter
112CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
113(i) 1:3:6 Mix (M-10)
114(iii) 1:1.5:3 Mix (M-20)
115STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
116EARTHING:
117(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
118(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm l.
119ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
120Erection of tower (with extension upto 9 Meters)
121CONDUCTOR STRINGING: Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
122(i) Single Conductor
123Installation of OPGW cable & Accessories
124Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
125Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
126Joint box (48 Fibre)
127Revitment work
128(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
129(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
130(C )Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
131(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
132Land Compensation
133Identifcation of land and preparation of land compensation case
134Documentation of preparation of case of land compensation
135BIRD FLIGHT DIVERTER
136INSTALLATION OF NON LED TYPE BIRD FLIGHT DIVERTER
137INSTALLATION OF LED TYPE BIRD FLIGHT DIVERTER
138Any Other Item
139Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
140High Tensile Steel
141Mild Steel
142Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
143Supply of Earthing material of Towers
144Pipe Type Set
145Counter Poise Earthing set
146Supply of following Tower Accessories
147Danger Plate
148Number Plate
149Phase Plate (Set of three)
150Design, manufacture and supply of following line material. **
151Disc Insulator - 70 kN
152Porcelein Long Rod Insulators 70 kN
153Disc Insulator - 120 kN
154Porcelein Long Rod Insulators 120 kN
155Hardware Fittings for ACSR Panther Conductor
156Single Suspension H/W fittings for ACSR Panther Conductor
157Single Tension H/W fittings for ACSR Panther Conductor
158Double Suspension H/W fittings for ACSR Panther Conductor
159Double Tension H/W fittings for ACSR Panther Conductor
160Accessories for ACSR Panther Conductor
161Mid Span Compression Joint for ACSR Panther Conductor
162Repair Sleeve for ACSR Panther Conductor
163Preformed Armour Rod for ACSR Panther Conductor
164Vibration Damper for ACSR Panther Conductor
165OPGW Cable
16648 Fibre (DWSM) OPGW fibre optic cable
167Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
168Joint box (48 Fibre)
169BIRD FLIGHT DIVERTER
170NON LED TYPE BIRD FLIGHT DIVERTER
171LED TYPE BIRD FLIGHT DIVERTER
172Any Other item required for successful completion of work
173Note: *One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW. ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
174Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
175Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
176Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
177(i) Any soil, soft rock other than hard rock
178(ii) Hard Rock (with blasting subject to permission or without blasting)
179SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
180(i) Tower including extension upto 9 Meter
181CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
182(i) 1:3:6 Mix (M-10)
183(iii) 1:1.5:3 Mix (M-20)
184STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
185EARTHING:
186(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
187(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm l.
188ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
189Erection of tower (with extension upto 9 Meters)
190CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
191(i) Single Conductor
192Revitment work
193(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
194(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
195(C )Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
196(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
197OPGW cable & Accessories
198Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
199Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
200Joint box (48 Fibre)
201Land Compensation
202Identifcation of land and preparation of land compensation case
203Documentation of preparation of case of land compensation
204BIRD FLIGHT DIVERTER
205INSTALLATION OF NON LED TYPE BIRD FLIGHT DIVERTER
206INSTALLATION OF LED TYPE BIRD FLIGHT DIVERTER
207Any Other Item
208Tower: Fabrication, galvanising and supply of various types of towers (including special towers), & its body / leg (equal & unequal) extensions (complete) including stubs and hangers, D-shackles, Bird Guard, U-Bolt, Pack washer, Anticlimbing devices etc.
209High Tensile Steel
210Mild Steel
211Supply of Bolts & Nuts for towers and stubs (including step bolts & nuts and anti theft bolts & nuts, Spring Washers Etc. )
212Supply of Earthing material of Towers
213Pipe Type Set
214Counter Poise Earthing set
215Supply of following Tower Accessories
216Danger Plate
217Number Plate
218Phase Plate (Set of three)
219Design, manufacture and supply of following line material. **
220Disc Insulator - 70 kN
221Porcelein Long Rod Insulators 70 kN
222Disc Insulator - 120 kN
223Porcelein Long Rod Insulators 120 kN
224Hardware Fittings for ACSR Panther Conductor
225Single Suspension H/W fittings for ACSR Panther Conductor
226Single Tension H/W fittings for ACSR Panther Conductor
227Double Suspension H/W fittings for ACSR Panther Conductor
228Double Tension H/W fittings for ACSR Panther Conductor
229Accessories for ACSR Panther Conductor
230Mid Span Compression Joint for ACSR Panther Conductor
231Repair Sleeve for ACSR Panther Conductor
232Preformed Armour Rod for ACSR Panther Conductor
233Vibration Damper for ACSR Panther Conductor
234OPGW Cable
23548 Fibre (DWSM) OPGW fibre optic cable
236Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box
237Joint box ( 48 Fibre)
238BIRD FLIGHT DIVERTER
239NON LED TYPE BIRD FLIGHT DIVERTER
240LED TYPE BIRD FLIGHT DIVERTER
241Any Other item required for successful completion of work
242Note: *One set of installation hardware shall contain all installation hardware fittings as may be required for 1 km of OPGW. ** Quantity indiacted is for evaluation purpose. Actual quantity to be supplied after getting approval from owner. *** Bidder will quote either for Disc or Long Rod or Composit Long Rod insualtors. In case of bidder quote for more than one types of insulators, then in evaluation heighest cost of insulators will be considered.
243Detail Survey as per tentative route-Which includes the following major activities-Pegging of line route, providing of survey pillar at an interval of 3-4 KM in the line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line, marking of side clearance for hills, sand dunes etc, as per specification and tower scheduling.
244Check survey as per approved route of line which includes-Re-checking of the line route as per approved profile, chainage, tower center marking, pit marking, bisection of angle tower as required at site.
245Excavation-Excavation, excluding back filling, including shoring,shuttering, dewatering, etc. upto the required depth as per foundation specification/drawings.
246(i) Any soil, soft rock other than hard rock
247(ii) Hard Rock (with blasting subject to permission or without blasting)
248SETTING OF TEMPLATE & STUB/ANCHOR BOLT:-Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
249(i) Tower including extension upto 9 Meter
250CONCRETING: Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size,water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
251(i) 1:3:6 Mix (M-10)
252(iii) 1:1.5:3 Mix (M-20)
253STEEL REINFORCEMENT: Cutting, bending, welding of joints if required,fixing and placing of steel reinforcement as per specification and drawings including material.
254EARTHING:
255(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats &connectors, but including coke/charcoal, etc.,excavation,augering and backfilling in all types of soil.
256(B) Earthing of towers legs with counterpoise typeearthings excluding supply of materialsbut including excavation and backfilling in all types of soil.(i)each set by laying 4 wires each 15m long at a depth of 600mm l.
257ERECTION OF TOWERS: Erection of super structures including D-shackles,ACD, Hangers, U-Bolts, step bolts, danger plate, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rich paint
258Erection of tower (with extension upto 9 Meters)
259CONDUCTOR STRINGING: Stringing of ACSR Panther including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
260(i) Single Conductor
261Revitment work
262(A) Providing & laying cement concrete including curing compaction etc. complete using stone aggregate 40 mm nominal size (Crusher broken) in foundation plinth using 1 cement : 5 sand : 10 Aggregate mix
263(B) Random rubble stone massonary for rivetment in 1:5 cement sand mortat including providing and fixing 100 mm dia PCC drain pipe and raised and cut pointing on stone masonary in 1:3 cement sand mortar excluding excavation but including Back filling inside rivetment using excavated/ borrowed earth (with all lead & lift) in layers not exceeding 20cm in depth & consolidating each depositing layer by ramming and watering.
264(C )Random rubble dry stone pitching including preparing surface etc. complete with raised & cut pointing in cement sand mortar 1:3, curing etc.
265(D)Cement concrete coping grade 1:2:4 (1 Cement:2 Coarse sand:4 Graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of step etc. complete for 50mm thik with 20mm thik nominal size aggregate
266OPGW cable & Accessories
267Stringing of 48 Fibre (DWSM) OPGW fibre optic cable
268Installation Hardware set for 48 Fibre OPGW Fibre Optic cabling including all cable fittings & accessories except joint box**
269Joint box (48 Fibre)
270Land Compensation
271Identifcation of land and preparation of land compensation case
272Documentation of preparation of case of land compensation
273BIRD FLIGHT DIVERTER
274INSTALLATION OF NON LED TYPE BIRD FLIGHT DIVERTER
275INSTALLATION OF LED TYPE BIRD FLIGHT DIVERTER
276Any Other Item Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57794617
AUTHORITY Government Departments
TENDER VALUE 136.59 Crore
LAST DATE 19-11-2026
Authority
Authority Name Rajasthan Rajya Vidhyut Prasaran Nigam Limited
Work Description Tender for Construction Work 220 Kv D/C Lohawat- Badi Sid Line At 220 Kv Gss Lohawat - 65 Kms. On Turnkey Basis Under Bid Enquiry No. Rvpn/Ehv/Bn-9019002612
Basic Detail
Tender No RVPN/EHV/BN-9019002612
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 03 Nov 2026
Submission Date 19 Nov 2026
Open Date 20 Nov 2026
Finance
Tender Value 136.59 Crore
Tender Fee 29500
EMD 2.74 Crore
Exemption Not Available
Document List
879a3a07-f490-4b6e-ace3-588c02ec87cb.html
BOQ_1064999.xls
CommercialBidDocument.pdf
ProjectSection.pdf
TechnicalspecificationofL_1.pdf
Tendernotice_1 (79).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 8 days
Nov 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Nov 20, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

879a3a07-f490-4b6e-ace3-588c02ec87cb.html

xls

BOQ_1064999.xls

pdf

CommercialBidDocument.pdf

pdf

ProjectSection.pdf

pdf

TechnicalspecificationofL_1.pdf

pdf

Tendernotice_1 (79).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender