Tender For Providing, Installation, Testing And Commissioning Of Fire Fighting With Wet Riser System In Cto Amin Building (G+6) Floor And Micro Wave Technical Building (G+3) Floor At Prayagraj (Up).
Tender Value
59.95 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
3 days left
EMD
1.19 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Prayagraj → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing, Installation, Testing And Commissioning Of Fire Fighting With Wet Riser System In Cto Amin Building (G+6) Floor And Micro Wave Technical Building (G+3) Floor At Prayagraj (Up).
BOQ
| Sl. No. | Item Description |
| 1 | SH-1 ( Wet Riser System) |
| 2 | Main Fire Pump |
| 3 | a) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, fire pump capable for delivery of 2280 LPM against atotal head of 70 Mtrs (Approximately) while running at 1450/1500 rpm mechanical seal as required BSNL approved make. c) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-12615: 2018. d) M.S. fabricated Common base plate, coupling,coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation dulyplastered with anti vibration pads Note: *The head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point.**The pump room is situated on the underground water tank. |
| 4 | 2280 lpm at 70 m Head |
| 5 | (Diesel Driven Pump) |
| 6 | a) Supplying, installation, testing and commissioning of die sel engine driven main fire pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required :(Diesel Driven Pump) (b) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze peller with stainless steel shaft, mechanical seal suitable to delivering 2280 LPM against atoatl head of 70 Mtrs ( Approxi) as required.(c) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.(d) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete foundation duly plastered and with anti vibration pads Note: * The head of the pump is selected in a manner so as to give a minimum 3.5kgf /cm2 pressure at the highest/farthest point. **The pump room is situated on the underground water tank. |
| 7 | 2280 lpm at 70 m Head |
| 8 | Jockey Pump |
| 9 | (a) Supplying, installation, testing and commissioning of electric driven pressurisation pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)(b)Horizontal type, multistage, centrifugal pump ofcast iron body and bronze impeller with stainlesssteel shaft, mechanical seal as required.(c)Suitable HP squirell cage induction motor TEFCtype suitable for operation on 415 volts, 3 phase50 Hz AC supply with IP 55 class of protection forenclosure, horizontal foot mounted type with Class'F' insulation, conforming to IS-12615: 2018. (d)M.S. fabricated Common base plate, coupling,coupling guard, foundation bolts etc. as required.(e) Suitable cement concrete foundation dulyplastered and with anti vibration pads.Note: *The pump room is situated on the underground water tank. |
| 10 | 180 lpm at 70 m Head |
| 11 | Supplying, installation, testing and commissioning of electric driven terrace pump conforming to IS 12469: 2019 suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(b) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal as required.(c) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class- 'F' insulation, conforming to IS-12615: 2018.(d) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(e) Suitable cement concrete foundation duly plastered and with anti vibration pads. |
| 12 | 900 lpm at 35 m Head |
| 13 | CONTROL PANELS:-Fabrication, supplying, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA eet, artmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required. INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A. |
| 14 | OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey PumpJockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto /manual /OFF operation Diesel Engine ControlControl for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual modeIndicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter |
| 15 | System ControllerDesigning, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication,complete as per specification |
| 16 | SITC of fully automatic DOL starter for Terrace pump Terrace Pump siutable for operation on 3 Phase 415 Volt AC supply I/c making inter connection testing etc as requiored at site. |
| 17 | SH-II (PIPES & ACCESSORIES) |
| 18 | Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS 1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. |
| 19 | 150 mm Dia |
| 20 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 21 | 50 mm dia |
| 22 | 80 mm dia |
| 23 | 100 mm dia |
| 24 | 150 mm Dia |
| 25 | 200 mm dia (wall thickness 6.3 mm) |
| 26 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required |
| 27 | Single headed Gunmetal |
| 28 | Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : |
| 29 | Single headed Gunmetal |
| 30 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 31 | 50 mm dia |
| 32 | 80mm dia |
| 33 | 100 mm dia |
| 34 | 150mm dia |
| 35 | 200mm dia |
| 36 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. |
| 37 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required |
| 38 | 50 mm dia |
| 39 | 80 mm dia |
| 40 | 100mm dia |
| 41 | 150 mm dia |
| 42 | Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. |
| 43 | 80 mm dia |
| 44 | 150 mm dia |
| 45 | 200 mm dia |
| 46 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and femalecouplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : |
| 47 | Gun Metal |
| 48 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required. a) 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 b) 20 mm nominal internal dia gun metal globe valve & nozzle. c) Drum and brackets for fixing the equipmets on wall. d) Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket |
| 49 | 30 Mtrs |
| 50 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required: |
| 51 | Gun metal |
| 52 | Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd for suitable dia MS pipe connection conforming to IS 904 as required: |
| 53 | 2 way-100 mm dia M.S. Pipe |
| 54 | 4 way - 150 mm dia M.S. Pipe |
| 55 | Providing, installation, testing and commissioning of C.I flanged swing type Foot valve ISI marked of following sizes confirming to IS: 4038 complete with all acessories complete etc.as required |
| 56 | 200 mm dia |
| 57 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with airrelease valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 58 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. |
| 59 | Providing and fixing in position industrial type pressure gauge with gun metal / brass valves complete etc. asrequired. |
| 60 | Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required: |
| 61 | 150 mm dia |
| 62 | Supplying and fixing of hose cabinet of size 750x mm X 600 mm X 250 mm made of 2 mm thick MS sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve , 2 Nos . 15 mtr. long Hose pipe, 1 no branch pipe, mounted on wall OR raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respect , for external hydrant ,as required. |
| 63 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 64 | SH-III ( Cabling and other Misc work) |
| 65 | Control wiring required |
| 66 | Providing of following sizes Stranded Aluminum Conductor, XLPE Insulated, PVC Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 |
| 67 | 4x16 sqmm |
| 68 | 3½ x 25 sq. mm |
| 69 | 3½ x 70 sq. mm |
| 70 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 71 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 72 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 73 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 74 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. |
| 75 | Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 76 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 77 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 78 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 79 | Upto 35 sq. mm |
| 80 | Above 35 sq. mm and upto 95 sq. mm |
| 81 | Above 185 sq. mm and upto 400 sq. mm |
| 82 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 83 | Upto 35 sq. mm |
| 84 | Above 35 sq. mm and upto 95 sq. mm |
| 85 | Above 185 sq. mm and upto 400 sq. mm |
| 86 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 87 | Above 185 sq. mm and upto 400 sq. mm |
| 88 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 89 | 4 X 16 sq. mm (28mm) |
| 90 | 3½ x 25 sq. mm (28mm) |
| 91 | 3½ X 70 sq. mm (38mm) |
| 92 | 3½ X 300 sq. mm (70mm) |
| 93 | Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. |
| 94 | Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. |
| 95 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 96 | SH-IV (Earthing ) |
| 97 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal / coke and salt as required. |
| 98 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 99 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 100 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 101 | Providing and fixing following sizes G.I. pipes complete with G.I. fittings including trenching and refilling etc. |
| 102 | 80 mm dia nominal bore Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender