Housing Urban and Rular Development Local Bodies Closing in 8 days TDR #57793479

Tender For Conservation Of Waterbodies.Sub Head:- Design, Supply, Installation, Testing & Commissioning Of Prefabricated Packaged / Potable Container Based Wastewater Treatment Plant Having Capacity Of 75 Kld And 25 Kld Including Operation & Maintena

Issued by Local Bodies · New Delhi, Delhi
Tender Value
1.74 Crore
Estimated cost
Bid Submission
08 Oct 2026
8 days left
EMD
3.48 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conservation Of Waterbodies.Sub Head:- Design, Supply, Installation, Testing & Commissioning Of Prefabricated Packaged / Potable Container Based Wastewater Treatment Plant Having Capacity Of 75 Kld And 25 Kld Including Operation & Maintenance For Three Years At Waterbody ( Khasra No.437, 75 Kld,) Ghitorni ,Waterbody(Khasra No.1030, 25 Kld) Mahipalpur, Waterbody(Khasra No.191, 25Kld) \Madangir.(Specialized Work) .

BOQ

Name of Work:- Conservation of waterbodies.Sub Head:- Design, supply, Installation, testing & commissioning of prefabricated packaged / potable container based wastewater treatment plant having capacity of 75 KLD and 25 KLD including operation & maintenance for three years at waterbody ( Khasra No.437, 75 KLD,) Ghitorni ,waterbody(khasra No.1030, 25 KLD) Mahipalpur, waterbody(Khasra No.191, 25KLD) \Madangir.(Specialized work) .
Sl. No. Item Description
1Design, supply, installation, commissioning and testing of fully FRP (steel/metal tanks coated with FRP shall not be accepted) suitable for underground installations and to withstand earth pressure, prefabricated packaged wastewater treatment plant (WWTP) of 75 KLd capacity (from reputed manufactures of make of Daiki Axis/ Shreya/ Fontus/ Ion Exchange/ Thermax/Sintex/Welspun or its equivalent approved make from waste water/ sewerage treatment plant manufacturers to the satisfaction of Engineer-in-charge with MBBR technology having treatment process with sedimentation and separation chamber, anaerobic contact media chamber, moving bed chamber (AEROBIC), sedimentation chamber, recirculation of accumulated sludge from sedimentation of 1st chamber, disinfectant chamber, clarified water tank, tertiary treatment processes: pressure sand filter, activated carbon filter etc. including all E & M and civil works for WWTP such as installation of plant/system i/c cost of excavation, preparation of foundation and making good after installation etc. complete in all respect and as per directions of Engineer-in-charge to make the system functional WWTPs shall also be operated and maintained for a period of one year (free of cost) after successful testing and commissioning. All consumables and chemicals required for operation, routine, preventive & breakdown maintenance and testing for outlet parameters shall also be borne by the agency during DLP. The FRP WWTP would be portable and shall conform to manufacturer’s specification. For designing purpose, inlet parameters to be considered are: pH : 6.5-8.5 BOD : 250-350 mg/ltr. Total TSS: 250-350 ms/ltr. COD: 400-500 mg/ltr. Fecal Coliform (FC) MPN/100 ml:> 10**7MPN/100ml. And Treated Waste Water Quality shall be: pH: 5.5-9 BOD:< 10 mg/ltr. TSS:<10 mg/ltr. COD, 50 mg/ltr. FC MPN/100 ml: Desireable-100 Permissible – 230. Scope of work is detailed as below:- a) Packaged and automatic plant of 75 KLd capacity with blowers, media etc. i/c transportation complete.b) Tertiary treatment Dual Media Filters (DMF) & Activated Carbon Filter (ACF) of capacity 75 KLd to achieve WWTP discharge standards prescribed by CPCB. The FRP vessel filter (Both DMF & ACF) complete with frontal piping and Automatic Multiport Valves with all the required accessories. Filters shall include media, standard fittings like pressure gauges, sampling cock, rinse drain. Filter Dia Minimum : 900 mm.Filter HOS Minimum : 1800 mm.Max Operating Pressure: 10 bar. Activated Carbon Media used for ACF shall be Coconut shell based, with minimum lodine value of 900 IV & minimum bed depth of 600 mm over supporting media.c) Raw water pumps 2 nos. (1W+1S) of appropriate capacity & approved make.d) Raw water tank of 20000 litres of HDPE of approved make.e) All interconnecting pipes and fittings in CPVC, Sch 20.f) The control panel shall be fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well s at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats or red oxide primer and final approved shade of powder coated paint. 2 nos. earthing terminals shall be provided for 1/3 phase, 4 wire, 50 Hz supply system. Panel should be complete with Isolation push button for every equipment and auto manual selection switches. The control shall be one integrated panel with all requisite controls for Raw Water Pump, Air Blowers & With Automatic Water Level Control. The panel shall be programmed for Auto operation & start up to requisite equipment as per indication from Water Level Controllers installed Treated Raw water tanks complete with all interconnecting can be and fittings.g) Bulk meter.h) All arrangements for supply of treated water for the area i/c cost of pump of required capacity.i) Making necessary connections with existing irrigation pipe network of the park along-with pump having appropriate capacity as per site requirement/ direction of Engineer-in-charge.j) Providing MS steel framed shelter of adequate size and height for housing tertiary units, pumps, blowers, panels, etc. using pre-coated GI profile sheets of approved brand of minimum thickness of 0.53/ mm with walls, roofs, flooring, locking arrangements, etc. complete as per the requirement /directions of Engineer-in-Charge.k) Any other items not specified/indicated in the contract but essentially required for satisfactory functioning of the plant will be deemed to have been included and same shall be executed bythe agency after approved of the Engineer-in-charge.
2COMPREHENSIVE OPERATION & MAINTENANCE OF WWTP of 75 KLD capacity and all other allied works/structures etc. created under the contract for a period of 2 years after expiry of free service period of 12 months on commissioning of WWTPs including all cost of labour, consumables, chemicals, repair/replacement of E & M parts, testing of outlet parameters/Security etc. as required. Year wise amount to be quoted in this BOQ Payment to be shall be released on quarterly on pro rata bases. No payment shall be made on account of any escalation or prices. Duties during O& M, plant shall be run 24/7. Adequate operators to be provided for proper plant operation. Treated water quality target should be monitored by random sampling. The scope of item includes monthly comprehensive maintenance for the WWTP (i/c tertiary treatment) including all spared supply and consumables. Electricity supply for the plant will be provided by DDA. .The O & M will commence from commissioning date (including free Ist year free O&M). The security deposit @ 2.5% deducted shall be released after completion of maintenance period (3 years) to the entire satisfaction of Engineer-in-Charge. Non-compliance of O & M requirement shall make the agency liable for recovery from the security deposit and/ or BG with DDA. The defect liability and safety of the WWTP/STP plant and its accessories during contract period (Construction, installation, commissioning and 3 years O & M) shall be sole responsibility of the contractor/agency.a) 2nd year
33rd year
4Design, supply, installation, commissioning and testing of FRP prefabricated single unit packaged wastewater treatment plant (WWTP) of 25 KLD capacity (from reputed manufacturer of make ofDaiki Axis/Shreya/Fontus/Ion Exchange/Thermax/Sintex/Welspun or its equivalent approved make to the satisfaction of Engineer-in-Charge) with MBBR technology having treatment process with sedimentation and separation chamber, anaerobic contact media chamber, moving bed chamber (aerobic), sedimentation chamber, accumulated sludge from sedimentation to 1st chamber, disinfectant chamber, clarified water tank, tertiary treatment process pressure sand filter and activated carbon filter etc. including all E&M and civil works for WWTP such as excavation, installation of plant/system (if cost of excavation, preparation of foundation and making good after installation etc. complete as required) and all consumables and chemicals required for operation, routine, preventive & breakdown maintenance and commissioning for a period of one year (free of cost) during defect liability period (DLP). The WWTP should be portable and containerized and all outlet parameters shall also be monitored by random sampling. For designing purpose, inlet parameters to be considered are: pH-6.5-8.5, BOD 250-350 mg/ltr., Total TSS-250-350 mg/ltr. The treated wastewater quality shall be: pH 5.5-9, BOD<10 mg/ltr., TSS<10 mg/ltr., COD<50 mg/ltr., FC.a) Packaged and automatic plant of 25 KLD capacity with blowers, media etc. c/c transportation complete.b) Tertiary treatment Dual Media Filters (DMF) & Activated Carbon Filter (ACF) complete with frontal piping and Automatic Multiport Valves with all required accessories. Filters shall include media, standard fittings like pressure gauges, sampling cock, rinse drain etc.Filter Dia Minimum : 400 mmFilter HOS Minimum : 1600 mmMax Operating Pressure : 10 barActivated Carbon Media used for ACF shall be Coconut shell based, with minimum iodine value of 900 IV & minimum bed depth of 600 mm over supporting media.c) Raw water pumps 2 Nos (1W+1S) of appropriate capacity & approved maked) Raw water tank of 10000 litres capacity of PVC of approved makee) All interconnecting pipes and fittings in CPVC, Sch 20f) The control panel shall be fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with an anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for each panel.1/3 phase, 4 wire, 50 Hz supply system. Panel should be complete with isolation push button for every equipment and auto manual selection switches. The control shall be one integrated panel with all requisite controls for Raw Water pump, Air Blowers & with Automatic Water Level Control. The panel shall be programmed for Auto operation & startup of requisite equipment as per indication from Water Level Controllers installed in Treated Raw water tanks complete with all interconnecting cable and fittings.g) Any other items not specified/indicated in the contract but essentially required for satisfactory functioning of the plant will be deemed to have been included and the same shall be executed by the agency after approval of the Engineer-in-charge.
5COMPREHENSIVE OPERATION & MAINTENANCE of WWTP of 25KLD and all other allied works/structures etc. created under the contract for a period of 2 years after expiry of defect liability/free service period of 12 months commissioning of WWTP including all cost of labour, consumables, chemicals, repair/replacement of E&M parts, testing of outlet parameters/Security etc. as required. Year wise amount to be quoted in this BOQ. Payment to be released on quarterly or pro rata bases. No payment shall be made on account of any escalation of prices. Duties during O&M plant shall be run 24/7. Adequate operators to be provided for proper plant operation. Treated water quality target should be monitored by random sampling. The scope of items includes monthly comprehensive maintenance for the WWTP (Tertiary treatment) including all spares, supply and consumables. Electricity supply for the plant will be provided by DDA. The O&M will commence from one year from the commissioning date. The contractor to submit Bank Guarantee (BG) at the end of the initial liability period of one year for an amount equivalent to yearly O&M amount before release of 1st RA bill for O&M. The security deposit @ 2.5% deducted from RA bills shall be released after completion of maintenance period of 3 years to the entire satisfaction of Engineer-in-Charge. Noncompliance of O&M requirements shall make the agency liable for recovery from the security deposit and/or BG and action.a) 2nd Year
6b) 3rd Year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57793479
AUTHORITY Local Bodies
TENDER VALUE 1.74 Crore
LAST DATE 08-10-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Conservation Of Waterbodies.Sub Head:- Design, Supply, Installation, Testing & Commissioning Of Prefabricated Packaged / Potable Container Based Wastewater Treatment Plant Having Capacity Of 75 Kld And 25 Kld Including Operation & Maintenance For Three Years At Waterbody ( Khasra No.437, 75 Kld,) Ghitorni ,Waterbody(Khasra No.1030, 25 Kld) Mahipalpur, Waterbody(Khasra No.191, 25Kld) \Madangir.(Specialized Work) .
Basic Detail
Tender No 37/EE/SPD-1/DDA/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 30 Sep 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 1.74 Crore
Tender Fee Ref. Documents
EMD 3.48 Lakhs
Exemption Not Available
Document List
58089825-be95-4baa-8708-b29b66cc7cca.html
BOQ_975465.xls
Tenderdocument037.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

58089825-be95-4baa-8708-b29b66cc7cca.html

xls

BOQ_975465.xls

pdf

Tenderdocument037.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders