Housing Urban and Rular Development Government Departments Closing in 1 days TDR #57793235

Tender For Construction Of 06 No 2-Bhk Residential Quarters, For Doctors At Sdh Sogam, Kupwara Advertised Cost: 481.92 Lacs.

Issued by Government Departments · Kupwara, Jammu and Kashmir
Tender Value
4.81 Crore
Estimated cost
Bid Submission
19 Oct 2026
1 days left
EMD
9.70 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kupwara → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of 06 No 2-Bhk Residential Quarters, For Doctors At Sdh Sogam, Kupwara Advertised Cost: 481.92 Lacs.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 CORRIGENDUM Other 19-Oct-2026

BOQ

Name of Work:- CONSTRUCTION OF 06 NO 2-BHK RESIDENTIAL QUARTERS, FOR DOCTORS AT SDH SOGAM, KUPWARA Advertised Cost: 481.92 Lacs.
Sl. No. Item Description
1Dewatering with pumps of adequate HP including Suction Delivery Pipe & DG Sets, Diesel, man-power etc. so as to dewater the entire site for laying of foundation including plugging of inflow water complete job as per the directions of Engineer in charge.
2Part A Civil Work:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil)
3Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
4Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete.
5Providing and laying in position cement concrete of specified grade M-10 including curing but excluding the cost of centering and shuttering - All work upto plinth level with 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
6Supply and filling G.S.B. under floors including watering, ramming and consolidating with hand rammer with aggregate size not exceeding 90 mm including cost and carriage of all materials involved upto site of work complete.
7Filling in with nallah boulders (75mm to 150mm thick) under floor handpacked & rammed including cost and carriage of all materials involved upto site of work complete.
8Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately.upto plinth level.
9Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately.above plinth level.
10Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete).
11Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc for mass concrete.
12Centering and shuttering including strutting, propping etc. and removal of form for:Lintels, beams, plinth beams, griders, bressumers and cantilevers
13Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars piers, abutments, posts and struts
14Centering and shuttering including strutting, propping etc. and removal of form for:Stairs, (excluding landings) except spiral staircases :
15Centering and shuttering including strutting, propping etc. and removal of form for:Suspended floors, roofs, landings, balconies and access plateform
16Providing and laying autoclaved aerated cement blocks masonry with150mm/230mm/300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. BirlaNu Aerocon AAC Blocks, Magicrete AAC Blocks, Siporex India AAC Blocks or equivalent.
17providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60±0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawingg & direction of Engineer-in Charge. (Including Single / double glass panes and silicon sealent). Casement door with top hung ventilator with 3D and S.S. friction hinges (400 x 19 x 1.9 mm) made of (big series) frame 67 x 64 mm, sash 67 x 110 mm & mullion 67 x 80 mm all having wall thickness of 2.3 ±. 0.2 mm and single glazing bead / double glazing bead of appropriate dimension.(Area of door upto 2.50 sqm). Fenesta, Prominance, VEKA, Deceuninck or equivalent.
18Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame andadjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately)Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be madeThree track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels) made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto1.75 sqm).
1915mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand)
2012mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 fine sand) in fine sand
216mm cement plaster to ceilings of mix 1:3 (1 cement : 3 fine sand)
22Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.2 mm thick
23Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer
24Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm except front side
25Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
26Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF /Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face #2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather siliconees sealant, backer rods etc
27Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 25mm thick with 12mm nominal size stone aggregate
28Providing and laying Vitrified wall tiles with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 1000x1000mm (Size 1200mm X 600mm). Bath Rooms
29Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 1000x1000mm (Size 1000x1000mm). Bath Rooms
30Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand and manufacturer, in all colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of tile 1000x1000mm (Size 1000mm X 1000mm).
31Providing and laying gang saw cut of specified thickness, mirror polished pre- moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in- Charge. 18 mm thick
32Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite Work
33Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (M.S.)
34Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brickballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
35Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
36Providing and Fixing of Hig Rib colour coated Sheet roofing of 0.50mm including polymer coated J or L Hooks and GI limpit washer
37Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2
38Providing valleys of 90cm wide overall in plain G.S. sheets fixed with polymer coated J. or L. hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gram/m2
39Providing and fixing plained eaves boarding 2nd class Deodar wood 250x32 mm (nominal size)
40Part B Sanitary and Plumbing:Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (Hand lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required.W.C pan with ISI marked white solid plastic seat and lid.
41Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps (01 Nos), 32 mm C.P. brass waste of standard pattern(01 Nos), including painting of fittings and brackets, cutting and making good the walls wherever required.White vitreous china wash basin size 550x400 mm with a pair of 15mm C.P. brass pillar taps.
42Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings
43Providing and fixing of C.P fitting of standard make and quality (Jaquar or equivalent)
44Bib Cock Long Body
45Basin Mixer
46Angle Value
47Wall Mixer
48Grating
49Ball Cock
50PVC waste pipe Flexible pipe 32mm
51GI Ball Valve (Zaloto Make) 32 mm dia
52GI Tanki Nipple 50mm Dia
53Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
54Providing and fixing toilet paper holder C.P brass
55Providing and fixing PTMT Soap Dish holder having length os 138 mm breadth 102mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms
56Providing and fixing health faucet with hose pipe for european water closet complete in all respect of approved quality (HINDWARE, Jaquare)
57Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms .
58Providing and fixing C.P. brass 32 mm size bottle trap of approved quality and make and as per the directions of engineer in charge.
59Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.
6015mm nominal outer dia pipes
6120mm nominal outer dia pipes.
6225mm nominal outer dia pipes.
6332mm nominal outer dia pipes.
6440mm nominal outer dia pipes.
6550mm nominal outer dia pipes.
66Centrifugal monoset self priming pump 1.5KW/ 2HP (CROMPTON)
67Pressure Pump with danfoss switch Kirloskar Brothers JALRAAJ-I ULTRA 1 HP
68Anti Microbial 1000 liter triple layer virgin plastic (COMFORT ISI MARK)
69Part C DrainageProviding, Fixing, Testing & Commissioning uPVC SWR pipes (Type-B) for soil, waste and vent conforming to IS 13592 along with all required fittings like tees, bends, cowls, crosses with or without access doors jointed with approved solvent cement fixed to walls and ceilings including angle supports with clamps complete including cutting holes in R.C.C/brick work (slab/beam/wall) and making good the floors, beams and walls with cement mortar where required complete of outer diameter.(Soil/ Waste pipe) (PRINCE ISI MARK)
70110 mm dia
71150 mm dia
7275 mm dia
7350 mm dia
7440 mm dia
75Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m(All Kinds of Soil)
76Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m
77Carriage of material Sand avg. lead 45 Km
78Carriage of material agg. Avg. Lead 25 Km
79Carraige of material AAC Blocks Avg Lead 110 Km
80Part D Drain:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil)
81Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m
82Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete.
83Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
84Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer- in - charge. Note: - Cement content considered in this item is @ 330 kg/ cum. Excess/ less cement used as per design mix is payable/ recoverable separately. All works upto plinth level
85Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
86Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc for mass concrete.
87Part D Boundary Wall:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil)
88Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete.
89Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
90Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) All works upto plinth level
91Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
92Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
93Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc for mass concrete.
94Centering and shuttering including strutting, propping etc. and removal of form for:Lintels, beams, plinth beams, griders, bressumers and cantilevers
95Centering and shuttering including strutting, propping etc. and removal of form for:Columns, pillars piers, abutments, posts and struts
96Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
97Extra for brickwork with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five
9815mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement : 4 fine sand)
99Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
100Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc
101Carriage of materialsSand average lead 45 km
102Stone aggregate .average lead 25 km
103Bricks lead 110 km lead
104Part E Sokage Pit & Septic Tank:Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:.(All kinds of soil)
105Providing and laying hand packed stone soling in foundation ,under floors etc. incl ramming, watering and consolidating complete ,cost and carriages of all materials involved upto site of work complete.
106Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
107Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) All works upto plinth level
108Reiforcement for R.C.C work including straightening, cutting, bending, placing in position & binding with binding wire all complete, Thermo Mechanically Treated Bars (500 D) (All work at all levels complete).
109Centering and shuttering including strutting, propping etc. and removal of form for:Foundations, footings, bases of columns etc for mass concrete.
110Brick work with common burnt clay (non-modular) bricks of class designation 7.5 infoundation and plinth including curing in : Cement mortar 1:6 ( 1 cement : 6 coarse sand)
11112mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand)
112Dry random rubble masonry with hard stone in foundation and plinth With bond stone.using quarry stone.
113Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
114Carriage of materialSand .average lead 45 km
115aggregate avg lead 25 km
116stones avg lead 25 km lead
117bricks avg lead 110 km lead
118Mechanical WorkDesign, Supply, Installation, Testing & Commissioning of a reputed make 06 passengers Machine Room Less (MRL) Type Gearless Machine lift (G+3). The lift shall be suitable for 06 passengers (408 Kg) of standard design having speed of 1.0 m/s serving from ground to 3rd floor i.e. 04 stops and 04 landings. All stops and landings on the same side. The elevator shall be of state of art technology, energy efficient drive and all its components / accessories shall conform to relevant IS standards. This shall also include a DLP of 01 year. Power Supply - 400/415 V (3 Phase AC) Control: Selective Collective Operation. Drive: VVVF Drive with feedback control (closed loop) Signals: Digital Car position indicator, car travels direction indicator in car and at all landings with call registration indicator. COP & LOP must have stainless steel face plate silver brushed with surface mounted button encoded with braille. Button: Floor pushbutton, alarm bell pushbutton, door open and close pushbutton etc. All buttons on car & landing shall be luminous & encoded with braille. Operation Push Button for lift maintenance & service should be present inside the car. Display type: Monochrome/ Colour LCD / Segmented LCD/ Scroll. CAR: • Design: Stainless steel in hairline finish. Car floor shall be of a flat non- slip or chequered surface. • Suitable for carrying minimum 06 passengers. Blower fan in car for ventilation. • Car Door: Stainless Steel Centre Opening/Side Opening provided with photocell detector technology. Landing Door: Automatic Stainless-Steel Centre Opening/Side Opening provided with photocell detector technology and having a fire rating as per OEM design. Round Handrail in Stainless steel finish provided on rear wall of car. PROTECTIVE DEVICES & OTHER ACCESSORIES: • ARD: Automatic rescue device complete with battery system for automatic evacuation to the nearest floor in case of power failure. Overload Protection: On overloading condition, the lift car will not start with door remaining open and give audio & display indication. • Motor overheat protection. Phase failure and phase reversal protection. Battery operated emergency lighting in the lift car. Emergency Alarm: Alarm button in car operating panel. Fireman switch and fireman control. • Voice Synthesizer: Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the lift. Buffers: As per manufacturer's standard conforming to IS. Counter weight shall be as per design. • Main Wire Rope / Belt: As per manufacturer's standard conforming to IS
119Supply, installation, testing & commissioning of 3-phase 15 KVA servostabilizer of reputed make including all allied electrical accessories. The stabilizer should have following specifications:Capacity: 15KVA, 3-phase unbalanced type• Input voltage: (90-220)V AC P-N, (150-460)V AC P-POutput: 415 V± 1% - phase to phaseSupply: 3 phase, 4 wires, 50Hz• Operation: Automatic• Duty cycle: 100% or continuous• Transformer windings: Copper wound on CRGO laminations as per IS specifications.• Cooling: Oilcooled (First oil filling provided)Efficiency: Better than 98% at full load• Overload Capacity: 15% for continuous 4 hours.•Waveform distortions: NilHigh speed voltage correction: up to 8V to 20V per second• Protections: Under voltage, Over voltage, Overload and short circuit protection.• Other features: LED indicators, AC ammeter, AC voltmeter, Frequencymeters, Single phase preventer, and Stabilizer by-pass arrangement.The job also includes P/F of 63A 4 Pole MCCB as incomer to the Servo Stabilizer to be provided in CRGO Enclosure
120SITC of electrical items viz., shaft bulk head lights, changeover panel comprising of 4 Pole 80A MССB (36KA Breaking capacity) as incomer, Manual change over with 125A bus bar and 4 Pole 63A MCCB -1 No. (36KА Breaking capacity) as outgoing for lifts provided in a powder coated CRC enclosure all of reputed make like Havells, L&T, Schneider. The job also includes all other allied major/minor electrical equipment's which may not have been specifically mentioned but are otherwise essential for thecommissioning of the lift. The job also includes chemical earthing of all the electrical components. The job further includes P/F of 1ft exhaust fan with all fittings in overhead area.
121Providing and laying of 4 core, 10 sqmm armoured Copper XLPE insulated cable along with timbles for connecting power source to MCCB, Servo Stabilizer, changeover panel and main panel of lift.
122Applying 12 mm cement plaster (1:4) including curing, with 3 more coats of white washing. Providing and fixing of Gang saw cut, mirror polish pre moulded and pre polished Granite of thickness 16 mm and shade/ colour/ texture as selected by site engineer fixed over base cement mortar 1:4 mix on facade and side walls of lift shaft openings on all floors, joints treated with white cement mixed with matching pigment, epoxy touch ups including rubbing, curing, moulding and polishing to edges to give high gloss finish and other minor works as per site requirements.
123Part F Electrical Part:Wiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No.of 6 Amp Modular Switch, Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/ Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & along with 2.5Sqmm (P+N+E) Circuit Wire of same make as mentinoned above & items shall be shall be approved before execution of work by SDO.
124Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Schneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work by SDO.
125Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
126Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified of Schneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work by SDO.
127Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
128Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified ofSchneider Zencelo/ Havells Crab tree/ Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work
129Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) & shall be approved before execution of work (Including Cost of Conduit/Channel)
1302x16 Sq.mm + 1 x 6 Sq.mm (P+N+E) for Power point Sub main in One run fromMain Panel to Distribution Boards.
1312x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for circuit wire
132Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/Havells/ABB/Eq. Make)
133Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K,Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens /Legrand/Havells/ABB/Eq Make)
13463 Amp
13540 Amp
13632 Amp
137Supplying and Fixing of MCB way 6-way (4 + 18), horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing ete, as required. (L&T/Siemens/Legrand/ Schneider/ABB/Eq Make)
138Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commerical Type) light luminary fitting round shape with minimumam system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,ССТ 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge 10 Protection of 2kV.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years,which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make.as approved by SDO.
139Providing & Fixing of IKO8 lP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate.The System level Luminaire efficacy >-125 Im/wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff (a>=300 V AC and Auto resetting Safety Power Factor >0.95, THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70%% of Initial Lumens maintained, CRI>70 and CСТ 5700K 355K Manufactures Word Mark Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products work, refer Annexure \\"A\\" attached with this BSR:-High Power LED Flood Light Minimum lumen output 6200 Im of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt.The job further mcludes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successfal commissioning handing over of site to intending department.
140Supply Installation Testing & Commissioning of 10W LED Mirror Light/Bed light of Havells Wipro Halonix Philıps Eq.Make as duly fitted on walls including making of necessary Connections & sample shall be approved by EIC.
141Supply Installation Testing and Commissioning of 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers. temperature rise=75 degree C (max.), nsulation resistance more than 2 mega ohm, suntable for 230 V. 50 Hz. single phase Supply, ete. complete as required. USHA Havells Anchor Crompton Greaves EqMake.(Minium 1-Star)
142SuppLaying/Connecting and Commissioning of 95 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench .(Material to be approved before execution)
143Supply/Installation/Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel ,dully Painted with powder coated paint dust protected earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified.The switch are adjustable type made of Havells/ L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/ L&T/Legrand/ Schneider Make.(1) Normal Incomer:a) 200 Amp-4-Pole ,36kA C-CURVE MCCB with extended terminalsHavells/L&T/Legrand/Schneider Make as approved=01 No.b) 300 Amps TPN Al. Bus Bar Set =01 Set, Digital Voltmeter ,Ammeter ,C.T Coils withSelector Switch & Phase indicator Set.Outgoing:(1) Normal outgoing for Heating/AC/Lighting/Inverter ete load(b) 63-Amp DP MCB = 06 No. as per site requirement)
144ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystallineconductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x300mm) with man- hole cover for the above. Including cost of 2OMM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
145Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Polycab/Eq. Make.(Min 1-Star) as directed by SDO
146Supplying, Installation, Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified
147Supplying, Installation, Testing and Commissioning of CO2 Type Fire Extinnsher 4.5 Kg. Capacity ISI Mark(1S:15683)suitable for 'B' and 'C\\" class fires inflammable liquids, gascous fires like L.P.G. and acetylene, and eleetrical fires
148Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessorics, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
149Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm/6 mm/10 mm thick (as specified), duly eut to required size and shape, fixed with necessary nuts, bolts, serews, washers, spacers ete., including finishing and making good the surface, complete as required
150Supply/Installation/Testing/Commissioning of Inverter 1150VA/12 V Pure Sinewave Inverter With Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 01 No. of 180Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery ete /Luminious/EXIDE /AMRON/Eq. Make Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57793235
AUTHORITY Government Departments
TENDER VALUE 4.81 Crore
LAST DATE 19-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of 06 No 2-Bhk Residential Quarters, For Doctors At Sdh Sogam, Kupwara Advertised Cost: 481.92 Lacs.
Basic Detail
Tender No NIT 41
Bidding Type Tender
Location
City Kupwara
State Jammu and Kashmir
Key Dates
Publish Date 15 Oct 2026
Submission Date 19 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 4.81 Crore
Tender Fee 5500
EMD 9.70 Lakhs
Exemption Not Available
Document List
19e7b55e-2df9-4040-b60d-a8178af0271e.html
BOQ_1104117.xls
Tendernotice_1 (23).pdf
Tendernotice_2 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

19e7b55e-2df9-4040-b60d-a8178af0271e.html

xls

BOQ_1104117.xls

pdf

Tendernotice_1 (23).pdf

pdf

Tendernotice_2 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender