Tender For Repairing & Overhauling Of One No Vt Pump & Motor 40 Hp Rating With Supply, Fitting & Fixing Of Spares At Ts 02 (Bay No 02) Pump House Under Integration/ Swtp, Kmda.
Tender Value
1.91 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
4 days left
EMD
3950
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Hooghly → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairing & Overhauling Of One No Vt Pump & Motor 40 Hp Rating With Supply, Fitting & Fixing Of Spares At Ts 02 (Bay No 02) Pump House Under Integration/ Swtp, Kmda.
BOQ
| Sl. No. | Item Description |
| 1 | Pump Repairing |
| 2 | Maintenance and overhauling of V.T. / inclined pumps as per manufacturers instruction manual with all tools, tackles etc. This job includes labour charges, consumables like O - ring, sundry cleaning material etc. This job includes dismantling of all sub assemblies such as gear box, cooling pipes, bearing housing, stuffing box, discharge tee, muff couplings, shafts, column pipes, bowl assembly, bell mouth, strainer, line shaft enclosing tube etc. Reconditioning of all parts, inspection of all parts & replace these parts as per instructions (spares cost excluded) straighthening of shafts & refitting of all parts & sub assemblies with proper alignment including motor removing & refixing, test & trial for 24 hrs etc complete.Capacity upto 05 cusec pump. |
| 3 | Manufacture and supply of pump spares/components as per specification, drawing or existing one with proper tolerence and finish as per direction. |
| 4 | i) Transmission shaft/ head shaft/ impeller shaft (Material: ST ASTM 276-316 ANLD) |
| 5 | ii) Shaft sleeve / gland sleeve (Material: ST ASTM 276-316 ANLD) |
| 6 | iii) Coupling Pin (Mat. CS IS1570-40c8 HOT RLD) in motor coupling. |
| 7 | iv) Neoprene rubber bush |
| 8 | v) Bearing Spider (Mat: CI FG 260 IS 210) |
| 9 | vi) Threaded shaft coupling (Material C45, IS-1570) |
| 10 | Supplying, fitting, fixing bolts with nuts, washer:(i) 10 to 16 mm dia: |
| 11 | (a) Length up to 75 mm |
| 12 | Motor Repairing |
| 13 | Preliminary checking of the whole motor (LT sq. cage IM) and testing of I.R. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar, double cage rotor end rings and all of motor bars and bar joints, housing of D.E. & NDE shield bearing housing etc. before work to detect fault. |
| 14 | Complete servicing and heat varnishing of 415Volt, 3 Phase L.T. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by Dr. Beck’s graded insulating varnish to obtain stable IR value, cleaning up the rotor, including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and RO priming on the end shield covers, bearing housing and complete the necessary repairing works as per direction of E.I.C.Upto 75KW LT sq. cage IM |
| 15 | Replacing and jointing of new 1.1KV grade 70 sq.mm. fibre glass copper wire terminals leads by 100% solder (Eyre) compounded with Eyre-7 paste, (6 leads). Upto 75KW LT sq. cage IM |
| 16 | Finishing the end of terminal leads by S & F dowells copper sockets properly supplying tapes, petrollium jelly etc. 6 nos.Upto 75KW LT sq. cage IM |
| 17 | Cost of mechanical work viz. shaft truness, checking key way looping of holes grinding and polishing etc.Upto 75KW LT sq. cage IM |
| 18 | S&F of new ball bearing no SKF 6211 to the NDE side of motor as directed by EIC. |
| 19 | S&F of new roller bearing no SKF 7316B to the DE side of motor as directed by EIC. |
| 20 | Supply and fixing of smart bright street light (36 Wafl) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make: Havells, 30 W LED. |
| 21 | Supply of pressure gauge 100mm dial size as per specification as per direction of EIC. |
| 22 | Less:- @ 10% for Un-useable & scrap materials Item no.-3,4,8,9,11,12,13,14 |
| 23 | Cess @ 1% |
| 24 | Added GST@ 18% except item no 11,12 & 14 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender