Tender For Construction Of 11 Kv Line And 100 Kva ,11/0.4 Kv Pole Mounted Dss For Providing Power Supply To Common Facility Center At Ramdaspur I.E., Cuttack.
Tender Value
7.82 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
2 days left
EMD
7830
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Cuttack → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 11 Kv Line And 100 Kva ,11/0.4 Kv Pole Mounted Dss For Providing Power Supply To Common Facility Center At Ramdaspur I.E., Cuttack.
BOQ
| Sl. No. | Item Description |
| 1 | Part A- Cost of Materials for 11 KV Cut Point with 90 Degree Angle- 1 No. |
| 2 | Supply & installation of WPB (GI) Pole 160x152 (11Mtr. Long,30.44KG/Mr.)(Total pole weight with base plate & stiffner = 334.84 Kg + 10.74 Kg = 345.58).Including excavation of pole pit in all king of soil with depth upto 1/6th of pole height. Complete in all respect as per the approved technical specification and direction of EIC. |
| 3 | Supply & installation of Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr. each channel(GI) length 1.2 mtr, 4no's channel(GI) required =( 4x9.56x1.2). Complete in all respect as per the approved technical specification and direction of EIC. |
| 4 | Supply & installation of Fish Plate(GI) 50x6mm., 2.36 kg/Mtr. each 0.280 mtr length,16 no's required =(16x2.36x0.280).Complete in all respect as per the approved technical specification and direction of EIC. |
| 5 | Supply & installation of Straight Cross Arm 100X50X6mm, 9.56 KG/Mtr., each channel(GI) length 0.306 mtr. 4no's channel(GI) required =(4x9.56x0.306). Complete in all respect as per the approved technical specification and direction of EIC. |
| 6 | Supply and installation of Danger Plate,1 no. Complete in all respect as per the approved technical specification and direction of EIC. |
| 7 | Supply and installation of Back Clamp for danger Plate 25X3 mm. flat(GI), 0.59Kg/Mtr. Flat(GI) of 0.510mtr length 1 no's= (1x0.59x 0.510) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 8 | Supply & installation of GI barbed wire anticlimbing device 3 Kg. per support. Complete in all respect as per the approved technical specification and direction of EIC. |
| 9 | Supply & installation of Back Clamp for anticlimbing device 25X3 mm. flat(GI), 0.59Kg /Mtr. Flat(GI) of 0.510mtr length 4 no's =(4x0.59x0.510). Complete in all respect as per the approved technical specification and direction of EIC. |
| 10 | Supply & installation of 11 KV pin insulator polymer. Complete in all respect as per the approved technical specification and direction of EIC. |
| 11 | Supply & installation of H W fitting (B&S) 70KN,3Bolt. Complete in all respect as per the approved technical specification and direction of EIC. |
| 12 | Supply & installation of Disc insulator (B&S) 70 KN polymer. Complete in all respect as per the approved technical specification and direction of EIC. |
| 13 | Supply & installation of Earthing of support(Coil Type). Complete in all respect as per the approved technical specification and direction of EIC. |
| 14 | Supply & installation of No-8 GI wire (Dia 4.6mm) 0.131 KG/Mtr- 2Mtr for connecting pole with coil earthing. Complete in all respect as per the approved technical specification and direction of EIC. |
| 15 | Supply & installation of NON METALLIC TIES-11KV 55SQMM CVRD AAAC. Complete in all respect as per the approved technical specification and direction of EIC. |
| 16 | Supply & installation of IPC FOR 55SQMM AAA CONDUCTOR (For covered conductor) - 11 KV. Complete in all respect as per the approved technical specification and direction of EIC. |
| 17 | Supply & installation of SPIKE(GI)(using 50x6mm flat(GI) welded with 8mm square bar)(2 no. Spike per set in each pole). Complete in all respect as per the approved technical specification and direction of EIC. |
| 18 | Supply and installation of H.T. Stay clamp, 50x8 mm. flat(GI), 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no's qty. reguired(1 Pair) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 19 | Supply & installation of H.T. Stay set (Complete). Complete in all respect as per the approved technical specification and direction of EIC. |
| 20 | Supply & installation of H.T. Stay Insulator Type-C . Complete in all respect as per the approved technical specification and direction of EIC. |
| 21 | Supply & installation of 7/10 SWG Stay Wire 15kg /stay. Complete in all respect as per the approved technical specification and direction of EIC. |
| 22 | Supply & installation of GI Nut, Bolt & Washer of different sizes (7.433 Kg each Cut Pole). Complete in all respect as per the approved technical specification and direction of EIC. |
| 23 | Supply and painting of Black paint(GIS Numbering & Zebra Stripping) as required and direction of EIC. |
| 24 | Supply and painting of Yellow colour paint(GIS Numbering & Zebra Stripping) for background as required and direction of EIC. |
| 25 | Part A- Cost of Civil Works. |
| 26 | Fixing of 11KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3)Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0.5 Cum cement concrete foundation 1:2:4 size (500mmx500mmx800mnm) using 20mm BHG metal with all labour and material .Complete in all respect as per TPCODL Drawing & Standard. |
| 27 | Concreting ratio 1:1.5:3 (M-20 Grade)(500mm X500mmX1800mm) = 0.45Cu.mtr(per Pole). Complete in all respect as per the direction of EIC. |
| 28 | Couping ratio 1:1.5:3 (M-20 Grade) with dimension (500X 500X450)= 0.1125 Cumtr(per Pole). Complete in all respect as per the direction of EIC. |
| 29 | Part B- Cost of Materials for 11 KV Pin Points With WPB - 0.02CKM. |
| 30 | Supply & Stringing of 55 SQ.MM AAAC XLPE Covered Conductor. Complete in all respect as per the approved technical specification and direction of EIC. |
| 31 | Part C- Cost of meterial for Line protecting Guarding for road crossing |
| 32 | Supply and Installation of Guarding Channel(GI) 75x40 x4.8 mm, 7.14 KG/Mtr,, each Channe(GI) length 2.2 mtr., 4 no's Channel(Gl) required = ( 4x7.14x2.2) ( For Single Pole). Complete in all respect as per the approved technical specification and direction of EIC. |
| 33 | Supply and Installation of No-6 GI wire (0.192 kg/mtr.) for Main String.Complete in all respect as per the approved technical specification and direction of EIC. |
| 34 | Supply and Installation of No-8 GI wire (0.131 kg/mtr.) for lacing.Complete in all respect as per the approved technical specification and direction of EIC. |
| 35 | Supply and Installation of Eye Bolt (236mm, 16mm dia, 1.577kg/mtr.). Complete in all respect as per the approved technical specification and direction of EIC. |
| 36 | Supply and Installation of GI pipe earthing 40mm ,3mtr long. Complete in all respect as per the approved technical specification and direction of EIC. |
| 37 | Supply and Installation of 50x6mm,Flat(GI) for earthing, 2.36kg/mtr,( 10.7 meter for rising) =10.7x2.36 .Complete in all respect as per the approved technical specification and direction of EIC. |
| 38 | Part -C : Cost of Civil Work |
| 39 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation, soil treatment with bentonide powder, calculation of earth resistance, including Installation of 3Mtr GI Pipe 40mm/ 50mm including welding of Flat(GI) around pipe.Complete in all respect as per the direction of EIC. |
| 40 | Part D- Cost of meterial for Pole mounted DSS (11/0.4 KV, 100 KVA DSS) with Transformer- 01 Nos |
| 41 | Supply and Installation of WPB Pole 160x152 (11mtr long , 30.44KG/MTR)-DP(Total pole weight with base plate & stiffner = 334.84 Kg + 10.74 Kg = 345.58). Including excavation of pole pit in all king of soil with depth upto 1/6th of pole height, Complete in all respect as per the approved technical specification and direction of EIC. |
| 42 | Supply and Installation of Top Channel (GI) 100X 50X6mm , 9.56 KG/Mtr., each Channel (GI) length 3 mtr., 2 no's Channel(GI) required =( 2x 9.56x3 = 57.36 Kg). Complete in all respect as per the approved technical specification and direction of EIC. |
| 43 | Supply and Installation of Fish plate(GI) 50x6, 2.36kg/mtr ,each 0.280mtr length, 6 no's required=(6x2.36x0.280).Complete in all respect as per the approved technical specification and direction of EIC. |
| 44 | Supply and Installation of AB switch mounting channel(GI) 75x40x4.8mm, 7.14kg/mtr each channel (GI) lenth 3mtr ,2nos channel(GI) required=(7.14x3x2 = 42.84 Kg).Complete in all respect as per the approved technical specification and direction of EIC. |
| 45 | Supply and Installation of AB Switch Side Support Channel (GI) 100X50X6mm, 9.56KG/Mtr, each Channel (GI) length 0.35 Mtr., 2 no's Channel(GI) required =(9.56x0.35x2). Complete in all respect as per the approved technical specification and direction of EIC. |
| 46 | Supply and Installation of Channel(GI) Support for down Pipe 75X40X 4.8mm. 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1). Complete in all respect as per the approved technical specification and direction of EIC. |
| 47 | Supply and Installation of HG/ DO Fuse Mounting Channel(Gl) 75x40x4.8 mm Gl Channel(GI) (3000 mm long) (7.14Kg./Mtr., 2 No's.) (Each 2x3.000x7.14 = 42.84 Kg). Complete in all respect as per the approved technical specification and direction of EIC. |
| 48 | Supply and Installation of Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel (GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.81x7.14 = 11.57 Kg).Complete in all respect as per the approved technical specification and direction of EIC. |
| 49 | Supply and Installation of Cantilever Support Angle(GI) 50 X 50 X 6MM GI (1282 mm long) (4.5Kg./Mtr, 2 No's.) (Each 2x1.282x4.5= 11.54Kg). Complete in all respect as per the approved technical specification and direction of EIC. |
| 50 | Supply and Installation of Transformer Base GI Channel(GI) 100 X 50 X 6 MM (3000 mm long) (9.56Kg/Mtr, 2 No's.) (Each 2x3.000x9.56= 57.36 Kg). Complete in all respect as per the approved technical specification and direction of EIC. |
| 51 | Supply and Installation Transformer Base Support GI Channel(GI) 100X 50 X 6 MM (515 mm long) (9.56Kg./Mtr, 2 No's) (Each 2x0.515x9.56= 9.85Kg) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 52 | Supply and Installation Transformer Belting Angle(Gl) 50 X 50 X 6 MM GI (3000 mm long) (4.5Kg./Mtr., 2 No's) (Each 2x3.0x4.5 Kg) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 53 | Supply and Installation Transformer Belting Support Angle(GI) 50 X 50 X 6MM GI (580 mm long) (4.5Kg/Mtr,2 No's) (Each 2x0.580x4.5= 5.22Kg) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 54 | Supply and Installation LTDB Mounting Angel(GI) 50 x 50 x 6 MM GI (1000 mm long) (4.5Kg / Mtr, 2 no's) (Each 2x1x4.5 Kg) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 55 | Supply and Installation of 50x6mm Flat(Gl) for earthing, 2.36kg/mtr., (2.5x7 mtr. For mesh formation, 12 Mtr. For LA and 2.5 mtr. For raising, 11 mtr for AB switch 2.8 mtr for HG Fuse, 5x2 mtr. for DTR Nutral, (1.3+4.5) mtr. For DTR Body, 0.500 mtr for LTDB & AB Switch operating handle, 3 mtr. for Fencing) (Each 65.6x 2.36= 154.81 Kg) .Complete in all respect as per the approved technical specification and direction of EIC. |
| 56 | Supply and Installation 100KVA,11/0.4KV(AL) Transformer,bis Energy Loss level II,Amendment-4.Complete in all respect as per the approved technical specification and direction of EIC. |
| 57 | SITC of LT Distribution Box with MCCB, Aluminium Busbar of 2 Bay with kit kat fuse for 100 KVA S/S. Complete in all respect as per the approved technical specification and direction of EIC. |
| 58 | SITC of 55 SQ.MM. AAAC XLPE Covered Conductor.Complete in all respect as per the approved technical specification and direction of EIC. |
| 59 | SITC of 4C x 150 mm2 LT XLPE Cable (Armoured) - FOR 100 KVA Trf.Complete in all respect as per the approved technical specification and direction of EIC. |
| 60 | SITC of AB Switch (11KV,200A,3pole,50Hz). Complete in all respect as per the approved technical specification and direction of EIC. |
| 61 | SITC of H.G.Fuse( 11KV,200A,3Pole). Complete in all respect as per the approved technical specification and direction of EIC. |
| 62 | Supply and Installation of WEDGE CONNECTOR FOR 55 SQMM.CONDUCTOR. Complete in all respect as per the approved technical specification and direction of EIC. |
| 63 | Supply and Installation of POLYCARBONATE BIRD GUARD. Complete in all respect as per the approved technical specification and direction of EIC. |
| 64 | Supply and Installation of Disc insulator (B&S) 70 KN polymer. Complete in all respect as per the approved technical specification and direction of EIC. |
| 65 | Supply and Installation of HW Fitting(B&S)70KN, 3Bolt. Complete in all respect as per the approved technical specification and direction of EIC. |
| 66 | SITC of Lightning Anester(12KV,10KA) (Station Class, class-2). Complete in all respect as per the approved technical specification and direction of EIC. |
| 67 | Supply and Installation of 11 KV pin insutator polymer. Complete in all respect as per the approved technical specification and direction of EIC. |
| 68 | Supply and Installation of HT Stay set complete.Complete in all respect as per the approved technical specification and direction of EIC. |
| 69 | Supply and Installation of HT stay clamp(1.9kg/pair). Complete in all respect as per the approved technical specification and direction of EIC. |
| 70 | Supply and Installation of H.T. stay insulater Type-C .Complete in all respect as per the approved technical specification and direction of EIC. |
| 71 | Supply and Installation of 7/10 swg GI Stay wire, Grade- 2 (15Kg/Set). Complete in all respect as per the approved technical specification and direction of EIC. |
| 72 | Supply and Installation of 40 mm Nominal bore GI pipe (medium gauge) earthing device with 3 mtr .Long. Complete in all respect as per the approved technical specification and direction of EIC. |
| 73 | Supply and Fixing of GI Nuts & Bolts of Assorted size (25 Kg/ DSS DP). Complete in all respect as per the approved technical specification and direction of EIC. |
| 74 | Supply and Installation of GI Barbed wire/ Anticlimbing device (3Kg /Pole). Complete in all respect as per the approved technical specification and direction of EIC. |
| 75 | Supply and Installation of Black Clamp for anticlimbing device 25x3 mm. Flat(GI), 0.59Kg /Mtr. Flat(GI)) of 0.510mtr length 8 no's= (8x0.59x0.510).Complete in all respect as per the approved technical specification and direction of EIC. |
| 76 | Supply and Installation of Danger plate ,11kv.Complete in all respect as per the approved technical specification and direction of EIC. |
| 77 | Supply and Installation of Back clamp for danger plate 25x3mm, Flat(GI) 0.59kg/mtr, Flat(GI) of 0.510mtr length 2 no's = (2x0.59x0.510). Complete in all respect as per the approved technical specification and direction of EIC. |
| 78 | Supply and Installation of Name Plate. Complete in all respect as per the approved technical specification and direction of EIC. |
| 79 | Structure Numbering and Marking |
| 80 | Supply and Painting of Yellow Colour Paint(GIS Numbering & Zebra Stripping) for Background as per Specification and the direction of EIC. |
| 81 | Supply and Painting of Black Paint(GIS Numbering & Zebra Stripping) as per Specification and the direction of EIC. |
| 82 | Pat -D : Cost of Civil Work |
| 83 | Concreting ratio 1:1.5:3(M-20 Grade) (500mmX500mm X1800mm)=0.450Cu.mtr (Per Pole) (For WPB Pole).Complete in all respect as per the direction of EIC. |
| 84 | Couping ratio 1:1.5:3 (M-20 Grade) (500mmX500mmX450mm)= 0.1125Cu.mtr(Per Pole). Complete in all respect as per the direction of EIC. |
| 85 | PCC ratio 1:3:6(M-10 Grade) For DSS Area (5X3X0.1)=1.5 Cu. mtr.Complete in all respect as per the direction of EIC. |
| 86 | Fixing of stay set with 0.5Cum cement concrete foundation 1:3:6(M-10 Grade) size ( 900mmx 600mmx900mm) using 40mm BHG metal with all labor and material except stay set, stay wire, stay insulator.Complete in all respect as per the direction of EIC. |
| 87 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation, soil treatment with bentonide powder, calculation of earth resistance, including Installation of 3Mtr Gl Pipe 40mm/ 50mm including welding of Flat(GI) around pipe.Complete in all respect as per the direction of EIC. |
| 88 | Laying of 4 Cx 150 mm2 LT XLPE Cable.Complete in all respect as per direction of EIC. |
| 89 | SITC and Erection of GI Fencing with Gate.Complete in all respect as per the approved specification and direction of EIC. |
| 90 | Supply of AL Lugs suitable for 150 sq mm cable/conductor,Crimping with cable and Fixing/ connecting include supply and erection of PVC Tape as per voltage requirement.Complete in all respect as per the direction of EIC. |
| 91 | Supply and erection of double Compression Flameproof Type Glanding for armored Cable 3.5/4C 120-185sqmm including making hole in Base plate and dressing of cable along with vermin proofing properly .Supply to be done as per TPCODL Spec and approved make dowells. |
| 92 | N.B: The bidders are required to Quote theire rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender