Tender For Up-Gradation Of Pump House At Khordha Industrial Estate, Khordha.
Tender Value
81.56 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
4 days left
EMD
81566
Bank guarantee accepted
Document Fee
11800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Up-Gradation Of Pump House At Khordha Industrial Estate, Khordha.
BOQ
| Sl. No. | Item Description |
| 1 | SITC of 11KV Rubber Mat(1M x 2M x 3MM) as per the approved specificatios and direction of EIC. |
| 2 | SITC of Earthing with copper plate 600m x 600mm x 3mm thick including accessories , and providing masonry enclousre with cover plate having locking arrangement and watering pipe 2.7 mtr long etc. with charcoal/coke/chemical & salt as required and Complete in all respect as per the approved technical specification and direction of EIC. |
| 3 | Wiring to light, ceiling fan, exhaust fan, call bell, & 6A On board with 1.5sqmm FRLS PVC insulated 1100 volt grade multistranded copper conductor wire for phase, neutral and earth continuity conductor run inside 2mm wall thick ISI mark HMS rigid PVC conduit pipe surface or recessed in wall/ column/ ceiling / above false ceiling / under the floor of the building including supply of materials such as clip-in type modular switches, metallic concealed box, wire, , junction box etc as per the electrical layout drawing & technical specifications complete with making good to the damages caused as required and Complete in all respect as per the approved technical specification and direction of EIC. |
| 4 | Single light point controlled by one 6A switch or first light point of group control. |
| 5 | 6A Socket & switch on existing Switch board |
| 6 | Supply, delivery, installation & testing of suitable size Separate metallic concealed box with modular plate and cover in front on surface including following type plug boards with interconnections and making good the damages caused complete as required and Complete in all respect as per the approved technical specification and direction of EIC. |
| 7 | 6 / 16 ampere plug boards consisting of a 6/16 amp clip-in type modular shuttered plug socket fixed on metallic concealed box |
| 8 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor including HMS conduit coupler,bend . Complete in all respect as per the approved technical specification and direction of EIC. |
| 9 | 2 numbers single core 4.0 sqmm copper wire for phase & neutral and 1 number single core 4.0 sqmm copper wire for earth continuity conductor including HMS conduit coupler,bend . Complete in all respect as per the approved technical specification and direction of EIC. |
| 10 | Supplying and fixing of separate 3 pin, 6 amp ceiling rose including connections etc. as required, as per drawing and Complete in all respect as per the approved technical specification and direction of EIC. |
| 11 | Supply and fixing of LED TUBE fittings with one No 20 watt, 6K LED tube . Complete in all respect as per the approved technical specification and direction of EIC. |
| 12 | Supply and Fixing of 60W LED Street Light Luminaire (>=120 lumen/Watt) of Crompton make or equivalent approved make such as Philips, Wipro, Bajaj or other approved reputed manufacturers, complete with die-cast aluminium housing, IP66 protection, high-efficiency LED module, integrated LED driver, mounted on a 40 mm dia, 1.5 m long heavy-duty hot-dip galvanized (HDG) GI bent pipe bracket, including base plate, clamps, nuts, bolts, anchor fasteners, wiring, glands, connectors, and all necessary accessories suitable for mounting on wall or any rigid structural member Complete in all respect as per the approved technical specification and direction of EIC.. Warranty from OEM for 5 years must be obtained. |
| 13 | Supply ,laying one number of 3.5C x 240 SQMM PVC insulated & PVC sheathed/XLPE cable, armoured aluminium conductor power cable of 1100 volt grade of following size in direct ground inclunding excavation,sand cushioning,protective covering and refilling etc as required, Complete in all respect as per the approved technical specification and direction of EIC. (From DTR & DG Set to Main LT Panel ) |
| 14 | Supply ,laying one number of 3.5C x 185 SQMM PVC insulated & PVC sheathed/XLPE cable, armoured aluminium conductor power cable of 1100 volt grade of following size in direct ground inclunding excavation,sand cushioning,protective covering and refilling etc as required, Complete in all respect as per the approved technical specification and direction of EIC. (From Main LT Panel to old Pump house Panel) |
| 15 | Supply ,laying one number of 3.5C x 120 SQMM PVC insulated & PVC sheathed/XLPE cable, armoured aluminium conductor power cable of 1100 volt grade of following size in direct ground inclunding excavation,sand cushioning,protective covering and refilling etc as required, Complete in all respect as per the approved technical specification and direction of EIC. (From Main LT Panel to New Pump house Panel , Old pump house Panel to 30HP Motor & 70KVAR Panel) |
| 16 | Supply ,laying one number of 3.5C x 70 SQMM PVC insulated & PVC sheathed/XLPE cable, armoured aluminium conductor power cable of 1100 volt grade of following size in direct ground inclunding excavation,sand cushioning,protective covering and refilling etc as required,Complete in all respect as per the approved technical specification and direction of EIC. |
| 17 | Supply ,Laying of one number 3.5C x 25SQMM PVC insulated and PVC sheathed /XLPE power cable of 1100 volt grade of following size on the existing cable Tray as required etc. Complete in all respect as per the approved technical specification and direction of EIC. |
| 18 | Supply laying one number of 4C x 16 SQMM PVC insulated & PVC sheathed /XLPE cable , armoured aluminium conductor power cable of 1100 volt grade of following size in the existing RCC/HUME/METAL pipe Complete in all respect as per the approved technical specification and direction of EIC. |
| 19 | Supply laying one number of 4C x 16 SQMM PVC insulated & PVC sheathed /XLPE cable , armoured aluminium conductor power cable of 1100 volt grade of following size in the existing cable Tray Complete in all respect as per the approved technical specification and direction of EIC. |
| 20 | Supply ,Laying of one number 3C x 16SQMM PVC insulated and PVC sheathed /XLPE power cable of 1100 volt grade of following size on the existing cable Tray as required etc. Complete in all respect as per the approved technical specification and direction of EIC. |
| 21 | Supplying & making end termination with Double Compression Cable Gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1KV grade as required. Complete in all respect as per the approved technical specification and direction of EIC. |
| 22 | 3.5 core x 240 sqmm A2XFY |
| 23 | 3.5 core x 185 sqmm A2XFY |
| 24 | 3.5 core x 120 sqmm A2XFY |
| 25 | 3.5 core x 70 sqmm A2XFY |
| 26 | 3.5 core x 25 sqmm A2XFY |
| 27 | 4 core x 16 sqmm A2XFY |
| 28 | 3 core x 16 sqmm A2XFY |
| 29 | HT CABLE |
| 30 | Supply laying one number of 3C x 95 SQMM PVC insulated & PVC sheathed /XLPE cable , armoured aluminium conductor power cable of 11 KV grade of following size in the existing RCC/HUME/PVC/HDPE/METAL pipe Complete in all respect as per the approved technical specification and direction of EIC. |
| 31 | Supply of 3C X 95 Sqmm cable end termination with heat shrinkable jointing kit complete with all accessories including ligs suitable for following size of 3 core XLPE aluminium conductor cable 11KV grade as required Complete in all respect as per the approved technical specification and direction of EIC. |
| 32 | Erection of outdoor end termination kits heat shrinkable type suitable for 11kv ,3 core 95 sqmm alluminium cable kits for 3core (set) as per direction of EIC. |
| 33 | Supply of HDPE PE 80-PN8 pipe of 110mm diameter (for 95sqmm HT cablel laying)as per techinical specification & direction of EIC |
| 34 | Laying of HDPE PE 80-PN8 pipe of 110mm diameter as per techinical specification & direction of EIC |
| 35 | Supply of materials & Fixing of G.I perforated cable tray along with hanging arrangements & supports fabrication complete. For sizes.300x50X1.6 mm thickness along with all fittings. Complete in all respect as per the approved technical specification and direction of EIC. |
| 36 | Supply of materials & Fixing of G.I perforated cable tray bend along with hanging arrangements & supports fabrication complete. For sizes.300x50X1.6 mm thickness along with all fittings. Complete in all respect as per the approved technical specification and direction of EIC. |
| 37 | Supply of materials & Fixing of G.I perforated cable tray along with hanging arrangements & supports fabrication complete. For sizes.100x50X1.6 mm thickness along with all fittings. Complete in all respect as per the approved technical specification and direction of EIC. |
| 38 | Supply of materials & Fixing of G.I perforated cable tray bend along with hanging arrangements & supports fabrication complete. For sizes.100x50X1.6 mm thickness along with all fittings. Complete in all respect as per the approved technical specification and direction of EIC. |
| 39 | EARTHING |
| 40 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe. Complete in all respect as per the approved technical specification and direction of EIC. |
| 41 | Supply of material & laying under ground / floor / wall including making end termination and testing of following sizes of G.I earthing conductor for loop earthing of equipments, switch boards & panels as required Complete in all respect as per the approved technical specification and direction of EIC. |
| 42 | 25 x 6 mm G.I flat (1.2 kg/mtr) |
| 43 | 50 x 5 mm Copper flat |
| 44 | Supplying and fixing of following sizes of Highly Mechanical Strenth class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. Complete in all respect as per the approved technical specification and direction of EIC. |
| 45 | 20 MM |
| 46 | 25 MM |
| 47 | OUT DOOR Panel & Distribution Boards |
| 48 | Supply, installtion, testing and commissioning of outdoorr(minimum IP54 with rain canopy) distribution boards made out of 3mm thick CRCA sheet steel duly acid treated for derusting, primered and painted with epoxy paint, dust, damp & vermin proved having hinged door with provision for cable entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant BIS and as per special conditions of contract making good the damages caused complete including supply of required supporting channels/angles with assembling the panels, interconnections etc as required and Complete in all respect as per the approved technical specification and direction of EIC. (including foundation as required) |
| 49 | Main LT PANEL |
| 50 | Incomer1:- 1 no 400A 4P MCCB 36KA ,(Microprocessor ) (from Transfromer )Incomer2:- 1 no 400A 4P MCCB 36KA ,(Microprocessor ) (from DG)Manual Change Over Switch:-1 no 400A 4P Manual Change Over SwitchBusbar : 630A. AL.TPN Busbar,415v Instruments: 2Sets of 0-500volt Digital MFM with inbuilt selector switch & 3 set of LED type phase indicating lamps with control fuses with required 400/5A CT,CL:0.5 Outgoing: (i) 2Nos 250A 4P MCCB ,36KA( For Old pump house panel & spare)(ii)3 Nos 160A 4P MCCB,36kA (For New pump house panel , 70 Kvar Panel & one spare)(iii)3 Nos 63A 4P MCCB ,25kA with KWhr & CT as required (Staff qtr, PH office & Spare)(iv) 3 Nos 32A 4P MCCB ,25kA with (Area lighting & spares)(iv)2No 16A DP MCB ,10kA 'C' Curve |
| 51 | Pump House Panel |
| 52 | New Pump House Panel |
| 53 | Supply, installtion, testing and commissioning of of indoor floor mounted type distribution boards made out of 2mm thick CR sheet steel duly acid treated for derusting, primered and painted with epoxy paint, dust, damp & vermin proved having hinged door with provision for cable entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete including Electrical panel room complete including supply of required supporting channels/angles with assembling the panels, interconnections etc as required and Complete in all respect as per the approved technical specification and direction of EIC. |
| 54 | Incomer:- 1 no 160 A 4P MCCB 25KA (from Main LT PANEL )Busbar: 200A, AL Busbar, 415 vOutgoing:(i)63Amp ,3P MCCB-6nos(iii)63Amp ,DP MCB-2nos1Set of 0-500volt Digital MFM with inbuilt selector switch & 3 set of LED type phase indicating lamps with control fuses with required 160/5A CT,CL.0.5 |
| 55 | Old Pump House Panel |
| 56 | Supply, installtion, testing and commissioning of of indoor floor mounted type distribution boards made out of 2mm thick CR sheet steel duly acid treated for derusting, primered and painted with epoxy paint, dust, damp & vermin proved having hinged door with provision for cable entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant ISS and as per special conditions of contract making good the damages caused complete including Electrical panel room complete including supply of required supporting channels/angles with assembling the panels, interconnections etc as required and Complete in all respect as per the approved technical specification and direction of EIC. |
| 57 | Incomer:- 1 no 250A 4P MCCB 25KA (from Main LT PANEL )Busbar: 400A, AL Busbar, 415 vOutgoing:(i)160Amp ,3P 25KA MCCB-3nos(ii)100Amp ,3P 25KA MCCB-2nos(iii)63 Amp ,3P 25KA MCCB-3nos(iv)63Amp ,DP MCB-2nos1Set of 0-500volt Digital MFM with inbuilt selector switch & 3 set of LED type phase indicating lamps with control fuses with required 250/5A CT,CL.0.5 |
| 58 | Pump House STATER Panel |
| 59 | Supply, installation, testing and commissioning (SITC) of 415V, 3 Phase, 50Hz, Indoor, Automatic Star-Delta Motor Starter suitable for squirrel cage induction motor operation, complete with sheet steel enclosure (IP-54 minimum), TP&N isolator/MCCB, magnetic contactors (Star, Delta & Main), thermal overload relay, timer, control transformer (where required), push buttons (Start/Stop), indicating lamps (R-Y-B, Run, Trip), control wiring, terminal blocks, cable glands, earthing terminals, name plate, and all necessary accessories for safe and satisfactory operation. The starter shall be suitable for wall/floor mounting and conform to relevant IS/IEC standards. The work shall include all labour, hardware, interconnections, testing, commissioning, documentation, and any other incidental works required for Complete in all respect as per the approved technical specification and direction of EIC. |
| 60 | 20HP/15KW Star delta stater |
| 61 | 15HP/11KW Star delta stater |
| 62 | Supply, delivery, installation, testing & commissioning of L.T. indoor wall mounted double door type distribution boards of original factory made enclosures of the same brand as the MCB conforming to the relevant IS and as per special conditions of contract making good the damages caused Complete in all respect as per the approved technical specification and direction of EIC. |
| 63 | BDB (12way SPN DB) IP-43 IK 09 with Metalic Door) |
| 64 | arial |
| 65 | 32A DP |
| 66 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Complete in all respect as per the approved technical specification and direction of EIC. |
| 67 | 5 amps to 32 SP MCB 10KA 'C' |
| 68 | SAFETY EQUIPMENTS |
| 69 | Supply and hanging of shock treatment chart duly bound/laminated/SLD. |
| 70 | SITC of carbon Dioxide (CO2) gas type fire extingulsher of 4.5 kg capacity with initial charge i/c discharge hose and hom,squeeze grip release valve,locking arrangement bracket with two screw and sleeve i/c fixing on wall as required.(Fire extinguisher shall be ISI marked conforming to IS:15683). Complete in all respect as per the approved technical specification and direction of EIC. |
| 71 | Cost of Supply,Erection,testing & commissioning of 11/0.4 KV DP S/S for 250 KVA transformer on 11 Mtr long RS Joist pole. |
| 72 | Supply,Erection,testing & commissioning of 150×150 Mtr RS Joist Pole (11mtr long)(34.6kg/mtr) including excavation of pole pit in all kind of soil and rock up to a depth of 1.5 mtr from ground level as required as per technical specification & direction of EIC. Complete in all respect as per the approved technical specification and direction of EIC. |
| 73 | SITC of Pressure Channel 100X50X6mm.2.8mtr. Long 2Nos. (9.2kg/mtr.) as per technical specification & direction of EIC. |
| 74 | SITC of Transformer mounting Channel 100x50x6mm. 2.8mtr.Long 2nos.(9.2kg./mtr.) as per technical specification & direction of EIC. |
| 75 | SITC of A/B switch and H.G. Fuse Mounting Channel 75x40x6mm. 2.8mtr.Long 4Nos.(6.8kg./mtr.) as per technical specification & direction of EIC. |
| 76 | SITC of Cantilever Channel for supporting A/B switch and HG fuse arm 75x40x6mm.1.5mtr.Long 4Nos. (6.8kg./mtr.) as per technical specification & direction of EIC. |
| 77 | SITC of Angle for cantilever arrangement for A/B switch & H.G. fuse 50x50x6mm. 1.5mtr Each , 4Nos. (4.5Kg/mtr.) as per technical specification & direction of EIC. |
| 78 | SITC of Angle for mounting L.T.Distribution box 50x50x6mm.-2.5mtr.Long,2Nos.(4.5Kg./mtr,) as per technical specification & direction of EIC. |
| 79 | SITC of 75x40x6 mm Channel 1.5 mtr. Long 1 No.(6.8 kg/mtr) for supporting of AB Switch handel as per technical specification & direction of EIC. |
| 80 | SITC of 11KV Disc Insulator (T & C type), 70KN, polymer) as per technical specification & direction of EIC. |
| 81 | SITC of 11KV H/W Fitting (T & C type),3 bolted) as per technical specification & direction of EIC. |
| 82 | SITC of 11KV A/B Switch 3Pole (400Amp) as per technical specifications and direction of EIC. |
| 83 | SITC of 11KV H/G fuse 3Pole (400Amp) as per technical specifications and direction of EIC. |
| 84 | SITC of Lightning Arrester(12KV,10KA) (Station Class,class-2) as per the technical specifications and direction of EIC. |
| 85 | SITC of H.T. Stay Set Complete as per technical specifications and direction of EIC. |
| 86 | SITC of HT Stay Insulator type-c as per technical specifications and direction of EIC. |
| 87 | SITC of HT Stay clamp(1.9kg/pair) as per technical specifications and direction of EIC. |
| 88 | SITC of 7/10 SWG Stay Wire as per technical specifications and direction of EIC. |
| 89 | SITC of G.I. Pipe Earthing, 40mm. Dia medium gauge 3mtr. Long as per technical specification & direction of EIC. |
| 90 | SITC of 25×6 mm GI flat for neutral earthing of transformer (1.2kg/mtr) as per technical specification & direction of EIC. |
| 91 | SITC of No. 6 G.I.wire for earthing(dia 4.8mm) as per technical specifications and direction of EIC. |
| 92 | SITC of Fixing of Stay anchor plate with 0.5 cum cement concreting foundation 1:3:6 size (900mm×600mm×900mm) using 40 mm BHG metal with all labour and material except stay set,stay wire,stay insulator as per technical specifications and direction of EIC. |
| 93 | SITC of Concreting of support CC 1:4:8 using 40 mm BHG metal size 5×2×2 = 20 CFT = 0.570 CUM, Padding 900×600×150mm =0.081 and couping of pole as per technical specifications and direction of EIC. |
| 94 | SITC of Material for masonary work for earth pit as required and as per the direction of EIC. |
| 95 | SITC of Charcol, Salt etc. for earthing as required and as per the direction of EIC. |
| 96 | SITC of Clamp, Connector & Jumpering material as required and as per the direction of EIC. |
| 97 | SITC of G.I. Nuts, bolt & Washer assorted size as per technical specifications and direction of EIC. |
| 98 | SITC of Sundries (Aluminum binding tap,insulating tap, Paint, danger Board, Clamp, Connectors, Anticlimbing device, etc.) as required and as per the direction of EIC. |
| 99 | SITC of L.T. distribution box with MCCB, busbar and fuse arrangement for 250 KVA transformer as per technical specification & direction of EIC. |
| 100 | SITC of L.T. 3.5core PVC Cable 300 sqmm for 250 KVA as per technical specification & direction of EIC. |
| 101 | SITC of socket & other cable accessories as required and as per the direction of EIC. |
| 102 | Construction of boundary wall with barbed wire fencing type with provision of gate as required and as per the direction of EIC. |
| 103 | Construction of Brick masonary plinth for installation of 250KVA transformer as per standard TPCODL norms as required and as per the direction of EIC. |
| 104 | Metals spreading as required and as per the direction of EIC. |
| 105 | 250KVA TRANSFORMER |
| 106 | SITC of 250 KVA, 11/0.4 KV (Cu) Transformer with Tap changer BIS Energy Loss level II, Ammendment-4. Complete in all respect as per the approved technical specification and direction of EIC. |
| 107 | CAPACITOR BANK 70 KVAr |
| 108 | Supply, installtion, testing and commissioning of outdoorr(minimum IP54 with rain canopy) distribution boards made out of 3mm thick CRCA sheet steel duly acid treated for derusting, primered and painted with epoxy paint, dust, damp & vermin proved having hinged door with provision for cable entry, earthing studs as per specification mentioned below duly factory wired conforming to the relevant BIS and as per special conditions of contract making good the damages caused complete including supply of required supporting channels/angles with assembling the panels, interconnections etc as required and Complete in all respect as per the approved technical specification and direction of EIC. (including foundation as required) |
| 109 | Busbar - 250 Amp Al busbar with SC rating of 25KA suitable for operation at 415 Volt, 50 Hz, 3 Phase supply |
| 110 | Incomer :- |
| 111 | 1no-160Amp, 4P,25 KA, MCCB with 3 Nos Phase indicating lamps with control fuse/MCB, 3 Nos 160/5 A , 15VA, Cl 0.5 CTs, Digital Voltmeter, Ammeter, |
| 112 | 1 Set - 6 step microprocessor controlled pf correction relay with LCD display, pf meter and CT of appropriate rating to be installed in Main LT Panel 1 on the incomer feeder from transformer. Auo/ Manual Selector switch |
| 113 | OutGoing:- |
| 114 | 5 Outgoing Feeders each provided with MCCB & MCB , Contactor, ON/OFF push button and indicating lamp and capacitors |
| 115 | 1 nos of Outgoings each Comprising with |
| 116 | 2 no - 63A TP, 10 KA,MCB. |
| 117 | 2 no - Capacitor duty contactor suitable for 25 KVAr capacitor(1x25 KVAr) |
| 118 | 2no-25 KVAr, 440V, TP Heavy duty capacitor with internal wiring, fuses,Harmonic Filter (7%) etc. complete as required |
| 119 | 1 no- aluminium wound dutuned Reactor for 25 KVAr capacitor. |
| 120 | 2 nos of Outgoing each Comprising with |
| 121 | 1no- 32A TP,10 KA,MCB. |
| 122 | 1no- Capacitor duty contactor suitable for 10 KVAr capacitor( 1x 10KVAr) |
| 123 | 1no- 10 KVAr,440V, heavy duty capacitor with internal wiring, fuses,Harmonic Filter (7%) etc. complete as required. |
| 124 | 1no- aluminium wound dutuned Reactor for 10 KVAr capacitor. |
| 125 | 1 nos of Outgoings each Comprising with |
| 126 | 2 no - 25A TP,10 KA,MCB. |
| 127 | 2 no - Capacitor duty contactor suitable for 5 KVAr capacitor(1 x 5KVAr). |
| 128 | 2 no- 5 KVAr, 440V, heavy duty capacitor with internal wiring, fuses,Harmonic Filter (7%) etc. complete as required. |
| 129 | 1no- aluminium wound dutuned Reactor for 5 KVAr capacitor. |
| 130 | OUTDOOR FEEDER PILLAR |
| 131 | Design Supply, delivery, installation, testing & commissioning of OFP(Outdoor feeder Pillar Panel) floor mounted type distribution boards with Suitable Indication Lamp , Voltmeter & Ameter with Selector Switch , made out of 2mm thick CR sheet metal cubicle fixed on m.s. channel base, duly acid treated for derusting, primered and painted with 2 coats of enamel paint of approved shade, dust, damp & vermin proof, having hinged with double door(minimum IP54 with rain canopy)and compartmental arrangement for each equipments , with having provision for cable entry, earthing studs as required, duly factory wired conforming to the relevant IS and as per special conditions of contract making good the damages caused Complete in all respect as per the approved technical specification and direction of EIC. |
| 132 | 1 no-400A,36 KA,4P MCCB |
| 133 | D.G.SET( 160 KVA ) |
| 134 | Supplying, Installation, Testing and Commissioning of Silent type DG Set having prime power rating of 160 KVA(CPCB IV+) at 0.8 pf at NTP conditions (Alternator directly coupled with Diesel Engine) with suitable breaker (to Satisfy all statutory norms of latest CPCB-IV norms) A. Alternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 160 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation, taken out for connecting through Cable along with all accessories.Complete in all respect as per the approved technical specification and direction of EIC. |
| 135 | Engine : Four(4) stroke, Multi cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP (to give prescribed output excluding power consumption for running Auxiliary Accessories) operating at 1500 rpm, daily fuel tank of minimum suitable capacity duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, SS flexible below for exhaust pipe and 12 V DC starting arrangement with minimum 1Nos of 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required.C. Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting as per standard practice of manufacturer etc. required.D. Acoustic Enclosur: The acoustic enclosure is made of 14 gauge CRCA sheet or more. The salient features of acoustic enclosure. |
| 136 | i) The Sheet metal components are Seven Tank pre treated before powder coating.ii) The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. iii) Specially designed attenuators to control sound at air entry and exit points.iv) Adequate ventilation to meet total air requirements. v) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature.vi) Emegency shut down button from outside the enclouser.vii) Noise level; <75 DB (A) at 1 mtr Distance. |
| 137 | Ambient Conditions: Temperature = 20 to 50 degree Celsius Relative Humidity = 95% max.Guarantee: The DG set shall be guaranteed for a period of 36 months from the date commissioning or 10000 hrs from the date of commissioning whichever occurs earlier. Coordination for Approval from Statutory Authority:Coordination for Approval from Statutory Authority all Input like Drawing & other Supporting Document & Coordination with the agency Vendor Scope CPCB IV+ etc approvals in the scope of the vendor.Cooling system: radiator cooled engine, mounted blower fan , engine mounted water pump, and thermo stat.Initial filling of corrosion inhibitor coolant by vendor. |
| 138 | Governing system : electronic governer controller Fuel system: Suitable capacity fuel tanks with connected pipes lines/hoses, stand for fuel tanks, overflow pipes, drain valves, air vent valves, strainers openings for inspection and cleaning with cover, level indication in the tank with scale to indicate the fuel stored, common outlet of tanks should be connected to the engine), full flow spin-on filters to the engine, fuel pump, injectors. The initial filling of fuel (high-speed diesel).Lubricating system: oil pump, strainer, spin-on filter, pipes, intimate lube grade, the capacity of the sump, initial tank filling of lube oil & Diesel shall be provided by the vendor. |
| 139 | Starting system :DC starter motor , battery charging alternator with in built regulator. suitable stand,suitable nos. of charged maintainace free batteries , with cable leads and terminal holders. battery make:exide /amaron /cummins pulse / amco/prestolite/sf Spare parts of filters Includes Lub Oil , Fuel & Air filter to be replaced up to 1000 hrs at free of cost whenever required. Fly wheel housing,flexible coupling,coupling guard, base frame : sturdy, fabricated, welded costruction, channel iron frame for mounting the above engine and below alternator . Battery charger from mains 230V AC Starting. HSD FUEL TANK:Supply,installation,testing and commissioning of minimum 385 liter HSD fuel tank.Errection & Commissioning:Supplier shall be responsible for carrying out the Erection, start up testing and commissioning of the new DG Set required technical personnel and labour for the same shall be provided by the vendor. Tools, tackles, required for the same shall be a arranged by the vendor. Erection of the Stack and thermal insulation of the exhaust system is also the responsibility of the vendor as per requirement. |
| 140 | .Operating Condition :The DG Set should work trouble free and efficiently under following operating conditions:Ambient Conditions: Temperature=20 to 50 degree Celsius Relative Humidity = 95% max.Coordination for Approval from Statutory Authority:Coordination for Approval from Statutory Authority all Input like Drawing & other Supporting Document |
| 141 | Suitable size of LTCT:- Metering arrangement with other accessories as required shall be provide by vendor .Design, supply and installation of Metering for DG,ISOLATOR PANEL:Isolator panel with 400A,MCCB,36KA with required CT ,Indiacation lamp & Voltmeter & Ammeter arranagement as Direction of EICFoundation:- With suitable foundation & fixing arrangement , be designed considering safe bearing capacity of soil and DG set static and dynamic load. . The depth of the foundation to be decided by the EIC |
| 142 | HT metering Unit DP |
| 143 | SITC of HT MU Mounting Channel(GI) 100X50X6mm, 9.56KG/Mtr, each Channel(GI) length 3 Mtr., 2 no's Channel(GI) required =( 9.56x3x2) as per the technical specifications and direction of EIC. |
| 144 | SITC of Cantilever Support Channel(GI) 75x40x4.8 mm GI Channel(GI) (810 mm long,2 No's.) (7.14Kg./Mtr., 2 No's.) (Each 2x0.81x7.14) as per the technical specifications and direction of EIC. |
| 145 | SITC of Angle(GI) for Cantilever arrrangement for HT MU 50 x 50 x 6 - 1282 mm.each 2 nos.(4.5 K.g. per mtr.) as per the technical specifications and direction of EIC. |
| 146 | SITC of MU and AB Switch Side Support Channel(GI) 100X50X6mm,9.56 KG/Mtr., each Channel(GI) length 0.35 mtr., 4 no's Channel(GI) required =( 9.56x4x0.35) as per the technical specifications and direction of EIC. |
| 147 | SITC of Channel(GI) Support for down Pipe 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 0.8 Mtr., 1 no's Channel(GI) required =( 7.14x0.8x1) as per the technical specifications and direction of EIC. |
| 148 | SITC of Double Pole Belting Channel(GI) 75X40X 4.8mm., 7.14KG/Mtr., each Channel(GI) length 3 Mtr., 2 no's Channel(GI) required =( 7.14x3x2) as per the technical specifications and direction of EIC. |
| 149 | SITC of 50x50x6mm.GI Bracing Angle(GI), 4.5Kg./mtr., each Angle(GI) length 3.512 mtr., 2 nos Angle(GI) required = (4.5x3.512x2) as per the technical specifications and direction of EIC. |
| 150 | SITC of Danger Plate, 2 no's as per the direction of EIC. |
| 151 | SITC of Back Clamp for danger Plate 25x3 mm. Flat , 0.59Kg/Mtr. Flat of 0.510mtr length 1 no's = (1x0.59x0.510) as per the technical specifications and direction of EIC. |
| 152 | Supply, paving and stringing of 55 mm2 ACSR PVC Insulated Conductor as per the technical specifications and direction of EIC. |
| 153 | SITC of Gi Pipe Earthing 40mm. 3 Mtr. Long as per the technical specifications and direction of EIC. |
| 154 | SITC of 50x6mm Flat (GI) for earthing, 2.36kg/mtr., (12.5 Mtr. For L.A, 3 Mtr for AB Switch Body, 2.5 mtr. For mesh formation and 2.5 mtr. For rising)= 20.5x2.36 & other uses as per the technical specifications and direction of EIC. |
| 155 | SITC of Lightning Arrester(12KV,10KA) (Station Class,class-2) as per the technical specifications and direction of EIC. |
| 156 | SITC of 11KV A/B Switch 3Pole (400Amp) as per technical specifications and direction of EIC. |
| 157 | SITC of GI Nut , Bolt & Washer of different sizes (7.433 Kg each Cut Pole) as required and as per the direction of EIC. |
| 158 | SITC of POLYCARBONATE BIRD GUARD as per the direction of EIC. |
| 159 | Supply and Painting of Black Paint as required and as per the direction of EIC. |
| 160 | Supply and Painting of Yellow colour paint for Background as required and as per the direction of EIC. |
| 161 | Civil Works |
| 162 | Construction Earthing chamber including installation of earthing pipe.Making earthing chamber including excavation , soil treatment with bentonide powder , calculation of earthresistance, including Installation of 3Mtr GI Pipe 40mm/50mm including welding of Flat(GI)around pipe. |
| 163 | Dismantling of 11 kV AB Switch set as per the direction of EIC. |
| 164 | DG & Panel Shed |
| 165 | Earth work in ordinary soil within 50m, initial lead and 1.5m, initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of the Engineer-in-charge |
| 166 | Cement concrete (1:1½:3) with 12 mm size hard granite chips .Complete as per direction of the Engineer-in-charge.(per Cum) . |
| 167 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting, fixing in position , complete as per direction of Engineer-in-charge. |
| 168 | Providing & fixing at all heights, levels and locations 0.4 mm thick GI roofing sheets and dimensions as per IS code with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed with 300mm overlap between two sheets to truss members in slope fixed with j hook,nut washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. |
| 169 | Conventional Type Lightning Arrester |
| 170 | Providing and fixing of lightning conductor finial, made of 25 mm dia 1000 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. |
| 171 | SITC of G.I. Pipe Earthing, 40mm. Dia medium gauge 3mtr. Long as per technical specification & direction of EIC. |
| 172 | SITC of 25×6 mm GI flat laid on ground & Surface with heavy-duty DMC/SMC insulated saddles/supports, including GI clamps, SS/GI fasteners, spacers and all necessary accessories complete as required shall be provided as per technical specification & direction of EIC. |
| 173 | SITC of Material for masonary work for earth pit as required and as per the direction of EIC. |
| 174 | SITC of Charcol, Salt etc. for earthing as required and as per the direction of EIC. |
| 175 | SITC of Clamp, Connector & Jumpering material as required and as per the direction of EIC. |
| 176 | N.B: The bidders are required to Quote theire rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender