Tender For Construction Of Kalyan Mandap, Koida G.P. Of Koida Block
Tender Value
71.81 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
7 days left
EMD
71819
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Kalyan Mandap, Koida G.P. Of Koida Block
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in hard soil or gravelly soil foundation & plinth within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per the direction of the Engineer-in-charge. |
| 2 | Filling foundation and plinth with sand well watered and rammed including cost, conveyance, royalty, taxes of all materials, labour and T & P required for the work etc. complete and as per direction of Engineer-in charge. |
| 3 | Cement concrete (1:3:6) with 4 cm. hard granite(Crusher Broken) metal including laying in layers not exceeding 300 mm in depth, ramming, compacting to proper thickness, watering and curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. |
| 4 | Cement concrete work with (1:2:4) using 12mm size hard granite(crusher broken) chips including hoisting and laying in position compacting to specified design section and curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete as per specification and direction of Engineer-in charge. |
| 5 | Brickwork with Flyash Bricks of size (23cm x 11cm x 8cm) in cement mortar (1:6) in foundation and plinth having crushing strength not less than 75.00 Kg/cm2 with dimensional tolerance ±8 percent immersing the bricks in water not less than six hours with cost conveyance, royalty, taxes of all materials, labor, and T&P required for the work, etc. complete and as per direction of Engineer-in-charge. |
| 6 | Brickwork with Flyash Bricks of size (25cm x 12cm x 8cm) in cement mortar (1:4) in superstructure having crushing strength not less than 75.00 Kg/cm2 immerging the with dimensional tolerance ±8 percent immersing in water not less than six hours with cost conveyance royalty, taxes of all materials, labour, and T&P required for the work, etc. complete and as per direction of Engineer-in-charge. |
| 7 | Reinforced cement concrete work of M-20 grade with 20mm & down grade size black hard crusher broken granite chips including hoisting and laying in position compacting to specified design section and curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. (excluding centring and shuttering) |
| 8 | Supplying, fitting, and placing uncoated HYSD bar reinforcement including labour charges for cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge with cost of steel rod and as per drawing, design, and direction of Engineer-in-charge. |
| 9 | Brickwork with Flyash Bricks of size (23cm x 11cm x 8cm) in cement mortar (1:6) in superstructure having crushing strength not less than 75.00 Kg/cm2 with dimensional tolerance ±8 percent immersing the bricks in water not less than six hours with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work, etc. complete and as per direction of Engineer-in-charge. |
| 10 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. foundation, plinth band and footings bases of columns mass concrete precast slabs, etc. |
| 11 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. Lintels Data for 7.8 sqm |
| 12 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. beams, column, grider and bressmer, etc. Data for 4.2sqm. |
| 13 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. floor and roof slabs, landings, balconies, projecting sun shades and chajjas up to 4.3m height |
| 14 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. stairs excluding landing but including railing details for 5 Sqm |
| 15 | Rigid and smooth centring and shuttering for R.C.C. works including false works and dismantling them after casting including cost of materials complete in ground floor R.C.C. walls and fins including attached pilasters |
| 16 | 2.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size hard granite chips including hoisting and laying in position compacting and curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete as per specificaion and direction of Engineer-in charge. (new work) |
| 17 | 16mm thick cement Plaster in CM (1:6) over brick work in inside including racking out joints finishing smooth with proper plumb and line, curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in-charge. |
| 18 | 6mm thick cement Plaster in CM (1:4) over R.C.C. surfaces in inside including chipping with proper level and line, curing for the proper period with cost conveyance, royalty, taxes of all materials, labour, and T & P required for the work, etc. complete and as per the direction of the Engineer-in-charge. |
| 19 | Supplying, fitting & fixing Vitrified Tile 600mmx600mm Coloured/Printed series (Homogeneous) in floors of size 600mm x 600 mm of approved make conforming IS: 13755 laid on 20 mm thick cement mortar (1:4) and filling joints with white cement of approved quality including cost of all work all materials, taxes, labour, T&P, etc. complete as per direction of Engineer-in-charge. |
| 20 | Fixing Vitrified tiles of premium grade having thickness 8mm to 10mm confirming to IS 13756 of size 600mmx600mm plain (Ivory) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the Vitrified tiles including rubbing and polishing complete including cost of precast tiles. |
| 21 | Fixing ceramic Tiles (30cmx30cm/40cmx40cm special plain/printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755) in floor, treads or steps and landing on a 25mm thick bed of cement mortar 1:1 (1cement: 1sand) jointed with neat cement slurry mixed with pigment to match the shades of the ceramic tiles including rubbing and polishing, cost of precast tiles complete as per direction of Engineer-in-charge. |
| 22 | Fixing ceramic Tiles (30cmx30cm/40cmx40cm special plain/printed series ceramic floor tiles of premium grade having thickness 7mm to 8mm confirming to IS 13755) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shade of the cerarmic tiles including rubbing and polishing, cost of precast tiles complete as per direction of Engineer-in-charge |
| 23 | Fixing Chequred Tiles in floor, treads or steps and landing on a 25mm thick bed of cement mortar 1:1 (1cement, 1sand) jointed with neat cement slurry mixed with pigment to match the shades of the Chequred tiles including rubbing and polishing, cost of precast tiles complete as per direction of Engineeer-in-charge. |
| 24 | Finishing surface of walls with cement based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour, T&P etc. complete and as per the direction of Engineer in Charge. |
| 25 | Finishing wall two coats with plastic emulsion paint of approved shades on new work to give an even shade including all costs of labour, Paint and Brushes required for the work, etc. complete and as per direction of the Engineer-in-charge.(Inside) |
| 26 | Supplying, fitting and fixing of 32mm local teak wood panelled shutters moulded panels with all labour, iron fittings, and wooden hinged cleats, etc. fitted and fixed complete in all respect, including cost of materials, labour, conveyance, taxes of all materials, T&P, etc. complete and as per direction of Engineer in charge |
| 27 | Supplying, fitting and fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Three Track-Three panel sliding window-60 Series duly manfactured using UPVC reinforced profiles of 108mm x 45 mm x 2.5 mm for outer frames and winodw sash 39 mm x 58 mm x 2.5mm capable of mounting single glazing system structurally reinforced with hot dip glavanised up to 50 microns of minimum thickness of 1.5 mm prefabricated & welded through fusion welding the window frame shall be fitted with 6 mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing/ deglazing at site etc. including cost and conveyance of all materials accessories, labour charges, materials and product conforming to ASTM D 638-14,EN-477-95 and other applicable codes and standards and as per direction of Engineer in Charge. (Rate given by Ofice of the Engineer-IN-Chief (Civil) Odisha Nirman Soudha Unit-V, Bhubaneswar vide letter no 20894 dated 26/05/2022) |
| 28 | Priming one coat with inner surface primer of approved quality water-bound primer over plastering surfaces including cost conveyance, taxes of all materials, labour and T&P required for the work complete as per direction of the Engineer-in-charge. |
| 29 | Priming one coat in inner surface with primer of approved quality over iron work including cost conveyance, taxes of all materials, labour and T&P required for the work complete as per direction of the Engineer-in-charge. |
| 30 | Painting two coats of enamel paint in outer surface paint including all costs of labour, Paint and brushes required for the work. etc. complete and as per direction of Engineer-in-charge.(Outside) |
| 31 | Supplying and fixing of 80mm thick cement concrete interlocking paver block of M-40 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018. (New miscellaneous items) and as directed by Engineer-in-Charge. |
| 32 | 12mm thick cement plaster (1:4) over brickwork in inside with cement punning for skirting/wall punning including racking out joints finishing smooth with proper plumb and line curing for proper period with cost conveyance, royalty, taxes of all materials, labour, and T & P required for the work, etc. complete and as per direction of Engineer-in-charge |
| 33 | Finishing wall two coats with weather coat with one coat waterbound Primer including all costs of labour, Paint, Primer, Brushes and putty required for the work etc. complete and as per direction of Engineer-in-charge. (Outside) |
| 34 | Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffing, polishing etc. with cost conveyance, taxes of all materials, labour. T&P etc. required for the complete in all respect and as per direction of Engineer in Charge |
| 35 | Supplying, fitting & fixing of Mild steel and put up for frames & shutters of Doors and windows fixing in position with cost, conveyance, taxes of all materials, labours and T & P required for the work etc. as per direction of Engineer-in-charge. |
| 36 | 12mm thick cement plster (1:6) over Brick work in outside including racking out joints finishing smooth with proper plumb and line curing for proper period with cost conveyance, royality, taxes of all materials, labour and T & P required for the work etc. complete and as per direction of Engineer-in-charge. |
| 37 | Supplying Installation fixing jointing testing & Commissioning of appproved Make Chlorinated Pol |
| 38 | Supplying Installation fixing jointing testing & Commissioning of appproved Make 32mm diaC PVC Pipe (Oriplast/Supreme) Chlorinated Pol |
| 39 | Supplying Installation fixing jointing testing & Commissioning of Submersibletype domestic/flushing water lift Pump |
| 40 | Supplying all materials Labour, T&P and fixing the following Vitreous Chain Wash Down water Closet |
| 41 | Supplying all materials Labour, T&P and fixing the following Vitreous Chain Wash Down water Closet |
| 42 | Supplying all materials Labour, T&P and fixing Health faucet of Hindware/Jaguar/Parryware Complete |
| 43 | Supplying all materials Labour, T&P and fixing Wash Basin of Hindware/Jaguar/Parryware Complete |
| 44 | Supplying all materials Labour, T&P and fixing of Mirror of Superior Glass mounted on 6mm thick AC |
| 45 | Fixing Rotational Moulded Poly Propelen double layer Cylinder vertical water storage tank |
| 46 | Supplying, fixing & testing PVC soil waste rain and Vent pipe (SWR) Supre conforming to 1513 |
| 47 | Supplying, fixing & testing PVC soil waste rain and Vent pipe (SWR) Supre conforming to 1514 |
| 48 | Recessed wiring to light point/fan point/exhaust point/ Wall Fan Point with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor of IS1 marked with 20 mm dia non-metalic PVC flexible conduit with 5 Amp, one way modular switch ISI marked and celling rose ISI marked mounted on Modular G.I. box having front bakelite cover of suitable size, MS box with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor as earth wire including all accesories and connection as per direction of Engineer in Charge. ( Make of wire Polycab/Finolex/L&T/Anchor/Havells/VGuard/KE/Great White] Modular Type -do-(Gr.A) (1.1.1-1.24.2) |
| 49 | -do-(Gr.B) (1.1.2-1.24.2) |
| 50 | -do- (Gr.C) (1.1.3-1.24.2) |
| 51 | S/F of M.S. Box for 2 Module 18 swg |
| 52 | S/F of M.S. Box for 4 Module 18 swg |
| 53 | S/F of M.S. Box for 8 Module 18 swg |
| 54 | S/F of M.S. Box for12 Module 18 swg |
| 55 | S/F of 3 pin 5/6 A.F.T switch and Socket on existing board (Modular type) (1.25.1+1.25.4) |
| 56 | S/Fof 6 module M.S. Box with Bakelite cover (Modular Type) on surface or in recess induding providing and foxing of 2 nos 3 pin 5/6 amp. Socket out let 5/6amp. Plano type modular switch,connection, painting etc. as required (1.24.4 +2x (1.25.1+1.25.4) |
| 57 | S/F of Power point with 4 modular metal box with modular base & cover In recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required |
| 58 | S/F of A.C.Starter 20Amp with 2 module Box. (Make Havells/Equivalent) |
| 59 | S/F of 15A Socket on 2 module for AC |
| 60 | S/F of 2 Modular box with 5A modular Socket outlet of ISI marked on Separate board for Wall fan |
| 61 | S/F of Power point with 4 modular metal box with modular base & cover in recess including providing and fixing of 6 pin 15/16 amp. piano type Modular switch & Socket, connection, painting etc as required for Inverter Connection |
| 62 | Wiring for arcuit/sub main alongwith earth wire with following sizes of PVC Insulated single core multistrand copper conductor with ISI marked conforming to 15-694/1990 in 20 mm dia non metallic heacy duty flexible conduit 1.6 mm in recessed PVC conduit as required (make of wire-Polycab/Finolex/L&T/Anchor/Mavels/V-Guard/KEI/Great White).2x1.5 sqmm+1 x 1.5 sqmm[1.8.1) |
| 63 | do-2 x 2.5 sqmm +1 x 1.5 sqmm (1.8.2) |
| 64 | do- 2x4 sqmm 1 x 1.5 sqmm (1.8.3) |
| 65 | do-2x6 sqmm +1 x 2.5 sqmm (1.8.4) |
| 66 | do-4x6 sqmm + 2 x 2.5 sqmm (1.8.10) |
| 67 | Inverter wiring (1x1.5smm) Copper wire (1.19.1) |
| 68 | S/F of 5 to 32 Amp rating 240 Voit \\"B\\" series MCB for lighting and other loads in the existing MCB Distribution Board ISI marked complete with connection, testing and commissioning etc. as required (2.6.1) |
| 69 | S/F of 32A rating \\"C\\" Series DP MCB (Make: L&T/Havells/C&S or Equivalent) |
| 70 | Supply, Installation testing and commissioning of 63 Amp. IC TPN Main Switches (IS13940 part 3/1993) with supply of metal box of following capacity on existing surface/Wall mounting & complete with H.R.C fuse links, inter connections earthing etc as required as per direction of Engineer Incharge (Make: HPL/L&T/C&S/Havells/Seimens/RK/Anchor/Havells) (2.15.3) |
| 71 | Supply of 250 mm x 300 mm x100 mm deep(1.24.23) for Foing 63 Amp ICTPN Main Switch. |
| 72 | S/F of 100 Amp. T.P.N. Cupper Bus Rar with all connections (Make:BENLO) |
| 73 | S/F of MCB 8 way Double door (2.3.6) |
| 74 | S/F of batten holder BK angle holder ISI marked including connection etc. Insulated of ceiling rose(1.29-1.28) |
| 75 | Earthing with G.I. Earth pipe 3 mtr Long 40mm dia ISI marked Including accessories & providing masonary enclosure with cover plate having locking arrangement & watering pipe with charcoal & salt as required (3.2) |
| 76 | Supply & laying 6 SWG G.I. wire in recess for loop earthing as required (3.17) |
| 77 | S/F of Fan hook S, Type on celling |
| 78 | S/F of step type modular fan regulator |
| 79 | S/F of 12 Watt. LED bulb. (Make Havells/Polycab or Equivalent) |
| 80 | S/F of 300 exhaust fan with all accessories and connections (Make-Usha-Aero Clean plus DBB/Polycab-Fress on DBB/Cromton-Trans Air 12\\" reversible/Havells-Ventil Air DS(HS)/Ancor-Anmol DelusR/Orient-Power Flow DBB |
| 81 | S/F of 1200mm A.C. Celling fan (1Star) with all accessories and connections with out fan regulator (Make:Usha-Striker One/Neo/Crompton-highspeed/Havells-Samrat ES/Anchor-Turbo Speed Star/Orlent-Summer Breeze Pro/Great White-ALDOUS/Pollycab-Vital HS) |
| 82 | S/F of 400mm A.C. wall fan with all accessories (Make: Usha-Max air ultra/Polycab-Aery HS/Crompton-wmhiflo wave/Havels-Accelero HS/Anchor-Altrix HS/Orient- Wall 43/Great white-WYNO Pro HS) |
| 83 | S/F of 18-25 watt LED Tube light fitting compoete with all connection. Inc'uding fixing and all accessories as per direction of Engineer-In-charge (Make: Havels/Phillips/Crompton/Polycab/HPL) |
| 84 | Supply & Fixing of 60 Watt single L.E.D street light fitting with LED & Electrinic driver including all accessories and connections (Make:Crompton/Philips/HPL/Polycab/Havells) |
| 85 | Supply of 3.5core 25 sqmm PVC insulated and PVC seathed / XLPE power cable of 1.1 KV grade Armoured cable (MAKE-HAVELLS/polycab/RR Kable/Rhino cable/equivalent) |
| 86 | Laying of MV Cable upto 25sqmm in ground (5.1.1) |
| 87 | Laying of MV cable upto 25sqmm on surface (5.5.1) |
| 88 | S/F of 40 mm HDPE pipe for laying & protection of cable(Make:Sudhakar or Equivalent) |
| 89 | S/F of 18W Recess Mount(Round/Square) Type Celling light (Havels/crompton/Polycab or Equivalent) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender