Tender For Construction Of Meeting Hall (S+1) At Sub-Collector Office At Uditnagar, Rourkela As Per Revenue And Dm Deptt. Lr. No. 1214 Dt. 08.01.2026 Buildings.
Tender Value
81.14 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
9 days left
EMD
81200
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Sundargarh → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Meeting Hall (S+1) At Sub-Collector Office At Uditnagar, Rourkela As Per Revenue And Dm Deptt. Lr. No. 1214 Dt. 08.01.2026 Buildings.
BOQ
| Sl. No. | Item Description |
| 1 | Civil Work-I Earth work in excavation in foundation in all kinds of soil including dressing and leveling the bed and depositing the soil within initial lead of 50 M and initial lift of 1.5 M as may be directed and providing shoring and shuttering & struts if necessary complete. |
| 2 | Supplying, filling in foundation and plinth with sand well watered and rammed in 22.5cm 9\\" layers with all leads and lifts cost, conveyance, labour, T&P etc. complete (measurement will be taken on finished compacted section only.) |
| 3 | Cement concrete (1:3:6) in foundation and plinth with HGCB metal of 4cm. (1/2\\") size including lowering, laying, cost, conveyance, royalties, taxes, labour, T&P watering, curing etc. complete. |
| 4 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. i)Column base |
| 5 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. vi) CHAJA & SUNSHED a) First floor |
| 6 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. ii)Column & beam a)Stilt floor |
| 7 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. ii)Column & beam b) First floor |
| 8 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. ii)Column & beam c) Second floor |
| 9 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. iii) Plinth beam a) Stilt floor |
| 10 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. iv) Lintel a) First floor |
| 11 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. v) ROOF SLAB a) Stilt floor |
| 12 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. v) ROOF SLAB b) First floor |
| 13 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. v) ROOF SLAB c) Second floor |
| 14 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. vi) CHAJA & SUNSHED b) Second floor |
| 15 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. vii) STAIR CASE a) Stilt floor |
| 16 | RCC work M20 grade using 12mm size HGCB chips of approved quality and from approved quarry including centering, shuttering, watering and curing with cost, conveyance, royalties & taxes of all materials, cost of labour, T&P etc. complete as per direction of the Engineer-in-charge. vii) STAIR CASE b) First floor |
| 17 | Cutting, bending, binding and tying the M.S. rod or Tor steel for RCC work including cost of all labour and materials etc. complete. a) Stilt floor |
| 18 | Cutting, bending, binding and tying the M.S. rod or Tor steel for RCC work including cost of all labour and materials etc. complete. b) First floor |
| 19 | Cutting, bending, binding and tying the M.S. rod or Tor steel for RCC work including cost of all labour and materials etc. complete. c)Secondfloor |
| 20 | Flyash brick of 9\\" size of work in cement mortar (1:6) on foundation and plinth including splays and cutting circular molding, watering and curing all cost, conveyance, royalties, taxes, labour T&P etc. complete. |
| 21 | Flyash brick of 9\\" size of work in cement mortar (1:6) in superstructure including splays and cutting circular molding, watering and curing all cost, conveyance, royalties, taxes, labour T&P etc. complete. a) Ground floor |
| 22 | Flyash brick of 9\\" size of work in cement mortar (1:6) in superstructure including splays and cutting circular molding, watering and curing all cost, conveyance, royalties, taxes, labour T&P etc. complete. b) First floor |
| 23 | Flyash brick of 9\\" size of work in cement mortar (1:6) in superstructure including splays and cutting circular molding, watering and curing all cost, conveyance, royalties, taxes, labour T&P etc. complete. c) Second floor |
| 24 | Supplying, fitting and fixing vertified tile in floors of size 600mm x 600mm ( Coloured or Printed ) of approved make laid on 20mm thick cement mortor (1:4) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work. a) First floor |
| 25 | Fixing vetrified tiles in dados skiring and risers of steps on 12mm thick cement plaster (1:3) joined with neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing ceomplete including cost of precast tiles. a) First floor |
| 26 | Fixing granite stones in floors treads or steps and landing on 25 mm thick bed of cement mortar 1:1 ( cement : sand ) jointed with neat cement slury mixed with pigment to match the shades of the tiles including and polishing complete including cost of granite. a) Ground Floor |
| 27 | Fixing granite stones in floors treads or steps and landing on 25 mm thick bed of cement mortar 1:1 ( cement : sand ) jointed with neat cement slury mixed with pigment to match the shades of the tiles including and polishing complete including cost of granite. b) 1st Floor |
| 28 | Supplying & fixing of industrial vitrified tiles on 20 mm thick bed of cement mortar 1:4 jointed with neat cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing etc complete. |
| 29 | 12mm ( ½) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete. a)Ground Floor |
| 30 | 12mm ( ½) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete. b) First floor |
| 31 | 12mm ( ½) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete. c) Second floor |
| 32 | 16mm (5/8) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete.a)Ground Floor |
| 33 | 16mm (5/8) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete. b) First floor |
| 34 | 16mm (5/8) thick cement plaster (1:6) finished smooth to brick walls after racking out joints including watering, curing all cost, conveyance, royalties, taxes, labour, T&P etc. complete. c) Second floor |
| 35 | Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge. a)Ground Floor |
| 36 | Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge. b) First floor |
| 37 | Providing 6 mm thick cement plaster in cm (1:4) to RCC surfaces finished smooth including closed deep chipping and slurry treatment including cost of all materials, labour, conveyance, loading and unloading, taxes, royalties, sundries, tols and plants etc. complete as per the driection of the Engineer in Charge. c) Second floor |
| 38 | Supplying, fitting and fixing well dressed seasoned sal wood work framed & fixed (wrought & put up) in trusses frames of doors, windows & ventilators including cost, conveyance, all labour, sundries, T&P etc. complete. |
| 39 | Supplying, fitting and fixing 32mm thick flush door shutters conforming to IS : 2002 including cost, conveyance, taxes of all materials and anodized aluminum fittings in all floors a) First floor |
| 40 | 2.5cm. (1) thick grading concrete (1:2:2) on roof slab with 6mm and down grade hard granite chips for old work including cost, conveyance, royalties and taxes of all materials, labour, T&P watering, curing etc. complete. |
| 41 | Appying wall surface of walls with acrylic wall putty s (water based) of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete. a)Ground Floor |
| 42 | Appying wall surface of walls with acrylic wall putty s (water based) of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete. b) First floor |
| 43 | Appying wall surface of walls with acrylic wall putty s (water based) of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete. c) Second floor |
| 44 | Distempering two coats over a coat of primer of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete.a)Ground Floor |
| 45 | Distempering two coats over a coat of primer of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete.b) First floor |
| 46 | Distempering two coats over a coat of primer of approved make and finished smooth and even including cost of scaffolding staging charges with cost of all materials, taxes, labour T&P etc. complete.c) Second floor |
| 47 | Supplying, fitting and fixing of M.S. window shuter made out of M. S. flat & sheet with ornamental design and hold fast attachment with all cost, labour T&P with one coat of red oxide primer etc. complete. |
| 48 | Supplying, fitting and fixing of M.S. window grill made out of square bar with ornamental design and hold fast attachment with all cost, labour T&P with one coat of red oxide primer etc. complete. |
| 49 | Supply and fixing of uPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 2 Track 2 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. |
| 50 | Supplying, fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90 Mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in staircase as per approved design and specification, buffinhg, polishing etc. with cost, conveyance, taxes of all materials, labour, T&P etc. required for the work complete in all respect. |
| 51 | Cement concrete (1:2:4) with 12mm size black hard granite crusher broken chips of approved quality from approved quarry including cost, conveyance, royalties & taxes of all materials, labour, T&P etc. complete. |
| 52 | Wall painting two coats with any approved weather paint over a coat of primer including cost, conveyance, taxes of all materials, labour, T&P required for the work including cost of paint complete in all respect. a)Ground Floor |
| 53 | Wall painting two coats with any approved weather paint over a coat of primer including cost, conveyance, taxes of all materials, labour, T&P required for the work including cost of paint complete in all respect. b) First floor |
| 54 | Wall painting two coats with any approved weather paint over a coat of primer including cost, conveyance, taxes of all materials, labour, T&P required for the work including cost of paint complete in all respect. c) Second floor |
| 55 | Painting two coats to wood and ironwork in any approved shade over one coat of primer including cost, conveyance, taxes of all materials, labour T&P required for the work including cost of paint complete in all respect. |
| 56 | Providing, fitting and fixing of false ceiling with Arm strong silhouette main runner, cross tee wall angle with fine tissured rH-99 board on 4 walls to be fixed by means of steel screw PVC plug and the Arm strong grid 2'0\\" x 2'0\\" suspended from ceiling etc. complete with all materials and all labour, T7P etc. as per specification approved by the Department and Engineer-in-charge. |
| 57 | Providing wall panelling made out of aluminium section vertical & horizontal at an interval of 2' 0\\" x 2'0\\" with 12 mm thick BWR ply with sunmica fixed on top layer including all cost, conveyance, taxes, labour , T&P etc complete. |
| 58 | Providing & fitting Centre table in Video Conference Room made of BWR plywood (ISO Certified) of 18 mm thick plywood with 1 mm decorative laminates (Sun-mica) etc complete including alll cost of labour, T&P hire charges of drilling machine, labour charges etc. complete |
| 59 | E.I. Work-II GROUP-A Sub-Head I (modular Wiring Items) Surface/Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable or equievalant) of ISI marked with 20 mm dia PVC flexible non metallic conduit(Make-AKG/Polycab or equievalant) with 6A modular type switch(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) ISI marked , and ceiling rose(Havells/Anchor/equievalant) ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. |
| 60 | GROUP-B Sub-Head I (modular Wiring Items) Surface/Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable or equievalant) of ISI marked with 20 mm dia PVC flexible non metallic conduit(Make-AKG/Polycab or equievalant) with 6A modular type switch(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) ISI marked , and ceiling rose(Havells/Anchor/equievalant) ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. |
| 61 | GROUP-C Sub-Head I (modular Wiring Items) Surface/Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor (Make-Havells/Polycab/Finolex/RR Kable or equievalant) of ISI marked with 20 mm dia PVC flexible non metallic conduit(Make-AKG/Polycab or equievalant) with 6A modular type switch(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) ISI marked , and ceiling rose(Havells/Anchor/equievalant) ISI marked of modular type G.I box with cover , of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. |
| 62 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. |
| 63 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 64 | Supplying,fixing of 16A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) (Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. |
| 65 | Supplying,fixing of 2x6A Plug on the separate board with complete fitting by 02 no of 6A switch & socket(modular type)with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power)complete suitable for office standard.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 66 | 1nos single core 1.5 sq. mm copper wire for phase copper wire for phase continuty conductor in 20 mm dia non metallic heavy duty PVC conduit (LDB to LSB/5A SOCKET) 1 x 1.5 sq. mm (for inverter wiring) Receass wiring for circuit/submain wiring with the following mentioned size PVC insulated, copper conductor FRLS, single core cable (Make-Havells/Polycab/Finolex/RR Kable or equievalant) or any other equivallent reputed make ISI marked as approved, in recessed PVC conduit Heavy duty (Make-AKG/Polycab or equievalant) of mentioned size or any other equivallent reputed make ISI marked as approved) as required as per direction of Engg.-in-Charge.. |
| 67 | 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty flexible conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 68 | 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5) |
| 69 | 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty flexible conduit . (2X4+1X2.5) |
| 70 | 2 nos single core 10 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty flexible conduit .(PANEL TO BDB EACH QTR) (2X10+1X4) |
| 71 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (OUTDOOR LIGHT-1, UPS -4 ) BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 /ABB(Equivalant model)/L&T(Equivalent model) or equievalant reputed make & model A catagory ISI marked as approved. as per direction of Engg.-in-Charge. |
| 72 | Supplying and fixing 6-32 amps rating, 240 volts, C series, Single Pole MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 73 | Supplying and fixing 6-32 amps rating, 240 volts, C series, Double poles MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 74 | Supplying and fixing 40-63 amps rating, 240 volts, C series, double pole MCB of Make-L&T/Legrand/Schneider/Siemens/ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 5 years Warranty on MCB is 5 years. |
| 75 | Supply and fixing modular type indicator on the existing switch box/cover of Anchor make as required as per direction of Engg.-in-Charge.(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) |
| 76 | Supplying and installation of AC starter Modular type or any other equivalent reputed make as approved coil voltage-415 Volt A.C. & O/L range of suitable range range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) |
| 77 | Supplying and fixing step regulator modular type on the existing switch box including connections but excluding box etc. as required as per direction of Engg.-in-Charge.(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) |
| 78 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover. as required as per direction of Engg.-in-Charge.(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) |
| 79 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge . |
| 80 | Supplying,fixing of Blanking plate(modular type) in existing switch box(including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..(Make-Legrand(myrius),Schneider (Zencelo),Panasonic(vision),Havells(equievalant),Hagar(equievalant) or equievalant) |
| 81 | Sub-Head II (Light fitting Fixture & Fan) Supplying, installation, testing and commssioning of BLDC 1200 mm sweep white/milky colour ceiling fan of or any other equivalent reputed make star rated as approved including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge .(With out fan Regulator) Make-Havells/Bajaj/Usha/Cromtron or equievalant model & make. |
| 82 | Supplying and fixing of Energy efficient recessed mounted 36 W LED luminaire (2 yrs warranty) and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. ( Make : Havells/Crompton/Jaquar/Panasonic/Bajaj/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved) |
| 83 | S/F of 12 Wled Bulb |
| 84 | Supplying, installation, of exhaust fan of 150 mm plastic exhaust fan (Make- Havells/almonard/Crompton/Usha or equievalant reputed make & model A catagory ISI marked as approved ) in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 85 | SITC of energy efficient LED tube light fittings with aluminium batten and LED tube light having power rating not more than 20 watt having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Havells/Crompton/Jaquar/Panasonic/Bajaj/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved) |
| 86 | 2.0 TRwith 5 StarBEE Ratine (Mitsubishi-MsY-GR22) 1 No 89,466.00 |
| 87 | S/F of Volatge Stablizer 5KVA for 2 ton split AC (130Vto300V.)make(V-Guard,Alfa , Microtek) |
| 88 | Supply ,installation ,testing & commissioning of 220VA Inverter(2 yr warranty) with double battery of 200AH 48 months warranty Make: Luminous/Microtek/Sukam/V-guard/Equivalent with stand, accessories, connections etc. each for one Light DB |
| 89 | S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITH charcoal and salt) as required as per direction of Engg.-in-Charge. |
| 90 | AIR TERMINAL AND ACCESSORIES ARRESTER+ MAST: Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, G.I tube,having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc complete as required with as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.2) .The entire LA system should be Replacement Warranty will be 5 years |
| 91 | Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required .as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.4) The entire LA system should be Replacement Warranty will be 5 years |
| 92 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.7) The entire LA system should be Replacement Warranty will be 5 years |
| 93 | Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For virtical run) as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.8) The entire LA system should be Replacement Warranty will be 5 years |
| 94 | Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.12) The entire LA system should be Replacement Warranty will be 5 years |
| 95 | Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required as per direction of Engg.-in-Charge. .(RATE REFERING OSR 2018 SOR NO-4.14) The entire LA system should be Replacement Warranty will be 5 years |
| 96 | S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ termination of G.I. flat / wire with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 97 | Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge. |
| 98 | Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.(DOUBLE RUN TO MAIN PANEL & APFC PANEL ,AC PANEL) |
| 99 | S/F of 63 A Main switch |
| 100 | Supplying and fixing of Energy efficient 90 w street light with bracket (2 yrs warranty) and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. ( Make : Havells/Crompton/Jaquar/Panasonic/Bajaj/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved) |
| 101 | P.H. Work-III Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge.25mm dia PVC ASTM pipe (sch-80) Ground floor |
| 102 | 32mm dia PVC ASTM pipe (sch-80) roof top |
| 103 | 50mm dia PVC ASTM pipe (sch-80)roof top |
| 104 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge First floor 20mm dia C-PVC Pipes |
| 105 | 25mm dia C-PVC Pipes |
| 106 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 15mm dia CP angle stop cock (Con-CHR-053KN Jaquar make) |
| 107 | 15mm dia CP Long Body Bib cock ( Jaquar make) |
| 108 | 15mm dia CP two in one bib cock ( Jaquar make) |
| 109 | 25mm dia brass full way valve (Shakti make) |
| 110 | 32mm dia brass full way valve (Shakti make) |
| 111 | 50mm dia brass full way valve (Shakti make) |
| 112 | Heallth Faucet |
| 113 | 15mm CP Extension piece |
| 114 | 125mm CP grating |
| 115 | 15mm size C.P. flange |
| 116 | 15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make) |
| 117 | Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 Meters. lengthx0.25 Meters width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13Meters thick circular protection wall of 0.46Meters height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank top of floor |
| 118 | supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.First floor |
| 119 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge First floor |
| 120 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge. First floor |
| 121 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Ori Plast/Finolex/Supreme Make ) |
| 122 | 110mm U-PVC P Trap(Ori Plast/Finolex/Supreme Make) |
| 123 | 110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make) |
| 124 | 110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make) |
| 125 | 110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make) |
| 126 | 110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make) |
| 127 | 110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make) |
| 128 | 110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make) |
| 129 | 110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make) |
| 130 | Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge.580mm size Orissa pan (Hindware/Parryware/Neycer make) |
| 131 | Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make ) |
| 132 | Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge European water closet with 'p' trap plain(Hindware/Parryware/Neycer make) |
| 133 | Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge |
| 134 | Supplying all materials,labour,T&P and fixing Flat back lipped wall (Mini stall urinal -630mmx180mm) urinal of the following sizes including connecting the urinal with 32mm. dia pvc waste pipe 910mm. long by means of white lead mixed with chopped hemp, fixing 32mm. dia CP dome waste, 15mm. dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. all complete as per specification and direction of the Engineer in charge Half stall urinal |
| 135 | Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge Halfpedestal basin(560x450)Hindware No.91049+91115 |
| 136 | Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mm x 600mm long CP towel rail(Jaquar)ACN-ACR-1111N |
| 137 | CP towel Ring(Jaquar)ACN-ACR-1121N |
| 138 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 600 x 125mm plate glass shelf with CP guard rails(Jaquar)AKP-CHR-35771P |
| 139 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. Design Large Mirror |
| 140 | Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder (Jaquar)ACN-ACR-1131N |
| 141 | SOAP DISPENSER WITH GLASS BOTTLE (Jaquar)ALD-BCH-769L250X190MI |
| 142 | Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 143 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 144 | Supplying the waterproofing material Tarshild or equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1'-6\\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge. First floor |
| 145 | Supplying all materials labour T&P filling sand in lavatories well watered and rammed including lead of materials to work site. |
| 146 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge First floor |
| 147 | Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size 40cmx40cm special printed series to be pre-approved by the Engineer-in-charge ) Ceramic tile 60cmx60cm First floor |
| 148 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. First floor |
| 149 | Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size 25cmx33cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Glazed tile 60cmx30cm First floor |
| 150 | Granite Tiles First floor |
| 151 | Supplying and fitting-fixing of Un-plasticised Poly Vinyl Chloride (UPVC) (FENESTA INCL VEKA LTO) Casement Toilet Door - 60- Series duly manufactured using UPVC reinforced profiles of 60 mm x 55 mmx2.5 mm for outer frames, 102 mm x 60 mm x 2.25 mm for casement Door Sash Profile and 74 mm x 60 mm x 2.5mm mullion profile capable of mounting single glazing system, structurally reinforced with hot dip galvanised up to 50 micrC?nsof minimum thickness of 2.0 mm prefabricated & welded though fusion welding. The Door sash shall be fitted with 12mm thick WPC Board ofGreenply make duly fixed with EPDM weathering seal resistant accessories like Toilet locking system made of aluminium 1 No., per set of sashes and the system is to beinstalled at the site using anchor fasteners, silicon rubber sealant. easy glazing/deglazing at site etc., including cost and conveyance of all materials. accessories,labour charges. The materials and product confirming to ASTM 0 638-14, EN-477-95 and other applicable codes and standards. |
| 152 | Supplying all materials, labour, T&P and providing fitting and fixing hight with water storage capacity 80 liter's along with 2 noa of faucets 1 for cold water and 1 for normal water including a flow of 1.5 ltr per munite etc all complete as per approved drawing , specification and direction of the Engineer in charge purifier |
| 153 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe |
| 154 | 150mm dia P.V.C. pipe |
| 155 | Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18 dia RCC MH cover |
| 156 | Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.8 m with 0.45 m (18 dia RCC Cover ) |
| 157 | Supplying all materials labour T&P and constructing .9m dia x 2.00 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site. |
| 158 | 1 no 05 Users Septic TankEarth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge. |
| 159 | Earth work in excavation of foundation in all kinds of soil with in 1.5m initial lift including dressing and leveling of bed and breaking the clods and the excavated materials with in 50m initial lead as per direction of Engineer in charge with 1st extra lift of 1.50 m over initial laft. |
| 160 | Supplying all materials labor T&P filling sand in foundation and plinth with well watered and rammed etc all complete as per direction of Engineer-in-charge. |
| 161 | Supplying all materials, labor T&P providing CC (1:3:6) with 4 cm HG metal including watering curing lead of all materials to site etc. complete. |
| 162 | Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge |
| 163 | Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge. |
| 164 | Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge. |
| 165 | Supplying all materials, labour, T&P and providing rigid & smooth centering and shuttering for RCC works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc. all complete as per specification and direction of the Engineer-in-charge RCC floor, roof slab chhaja up to 4.430 m height |
| 166 | Supplying all materials.labour.T&P and providing brick work in foundation and plinth with Fly Ash bricks having curshing strength not less than 75 kg/sqcm with dimensional tolerance+ 8% in cement mortar ( 1:3 ) including watering,curing,cost of all materials,conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer in charge. |
| 167 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. |
| 168 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:6) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.out side |
| 169 | Supplying all materials, labour, T&P and providing cement punning including watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per specification and direction of the Engineer-in-charge |
| 170 | Supplying all materials labour T&P and fitting and fixing 12mm dia MS/CI step iron including supply of necessary CC(1:2:4) for fixing etc. complete as per PH specification. |
| 171 | Supplying all materials, labour T&P for providing fitting & fixing 150mm x 150mm SW Tee in wall including filling the recess with cement concrete (1:2:4) with 12mm size HG chips all complete including watering curing conveyance of all materials to work site payment of royalty all complete as per specification and direction of Engineer in charge. |
| 172 | Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysOct 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender