Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #57788579

Tender For Replacement Of Rubber Seal And Epoxy Painting Work On Radial Gates And Other Electrical And Mechanical Work Of Kaka Sahib Gadgil Dam Under (Drip-Ii).

Issued by Government Departments · Ujjain, Madhya Pradesh
Tender Value
1.75 Crore
Estimated cost
Bid Submission
20 Nov 2026
0 days left
EMD
3.50 Lakhs
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ujjain → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Rubber Seal And Epoxy Painting Work On Radial Gates And Other Electrical And Mechanical Work Of Kaka Sahib Gadgil Dam Under (Drip-Ii).

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 06-Oct-2026 Amendment regarding Date Date 02-Nov-2026
2 03-Nov-2026 Keyssss date extended due to single bid as per attached document. Date 10-Nov-2026
3 15-Oct-2026 Amendment in Affidavit regarding correctness of information provided Other 10-Nov-2026
4 15-Oct-2026 Amendment in Affidavit regarding correctness of information provided Other 20-Nov-2026
5 10-Nov-2026 Amendment Date Date 20-Nov-2026
6 10-Nov-2026 Amendment regarding Eligibility and qualification criteria Technical Bid 20-Nov-2026

BOQ

Name of Work:- Replacement of rubber seal and epoxy painting work on Radial Gates and other electrical and mechanical work of kaka sahib gadgil dam under (Drip-II).
Sl. No. Item Description
1Supplying and fixing flat rubber seals and stainless steel countersunk bolts/ nuts/ washers of approved quality including cost of all materials, labour, removing existing worn-out/ damaged flat type rubber seals from gates, cleaning surface, making holes in new seals, fixing new seals /bolts/ nuts/ washers tightly in position, scaffolding etc. complete. Required size are as follows-
2Supplying and fixing bulb type teflon cladded rubber seals and stainless steel countersunk bolts/ nuts/ washers of approved quality including cost of all materials, removing existing worn-out/ damaged bulb type rubber seals from gates, cleaning surface, making holes in new seals, fixing new seals/ bolts/ nuts/ washers tightly in position, labour, scaffolding etc. complete.
3Painting of Spillway gates, sluice gates, canal gates (both vertical or radial),stop log gates, exposed embedded parts and all un machined ferrous surface (hoist cylinders, cylinder heads, hydraulic piping, pipe fittings, bonnet covers), exposed to water as per IS 14177,for which surface preparation by blast cleaning of class \\"B\\" primer coat (one coat) of inorganic zinc silicate (preferably airless spray)or alternatively, two coats of zinc rich primer(containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150±5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns, this will include expenses on mobilization and demobilization of equipment. For maintenance painting the surface preparation shall be done by appropriate hand and power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylot or white gasoline. After hand and power tools cleaning the surface should be cleaned of loose dust and debris and/or blast cleaned as laid down in para 7.0 of IS code 14177. After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. complete.
4Painting of machinery, including gearing, housing, shafting, bearing, pedestals, oil tanks, control cabinets, hoist beams, pipe support, clamps, ladders etc., of hoists and supporting structures, as per IS 14177, for which surface preparation by blast cleaning of class 'B', primer coat (one coat) of Zinc phosphate paint to give a minimum dry film thickness of 50 ± 5 microns and finish coat(three coats) of aluminium paint or synthetic enamel paint, using airless spray, to provide a dry film thickness of 25 ± 5 microns per coat. Thus, total dry film thickness of all the coats, including the primer coat, should not be less than 125 microns. This will include expenses on mobilisation and demobilisation of equipment. For maintenance painting, the surface preparation shall be done by appropriate hand and power tool cleaning. Prior to hand and power tool cleaning, any heavy layer of rust should be removed by chipping. Visible oil, grease, dirt and other foreign material can be cleaned using solvents like clean mineral spirits, xylol or white gasoline. After hand and power tool cleaning, the surface should be cleaned of loose dust and debris and / or blast cleaned as laid down in para 7.0 of IS Code14177. After the surface preparation, the primer and finishing coats shall be carried out as provided above for painting etc. complete
5Industrial hooter: Providing & fixing of industrial hooter speaker horn type ABS body with working AC Voltage 220V A.C./24V D.C. current consumption, sound output 120 DB, material M.S. sheet.
6G.I. pipe for protection of underground cable - Supplying & installing G.I. pipe for protection of underground cable fixed on wall/ support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendant for light luminaries /fan/ protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. For 'B' class pipe ISI marked (IS-1161-68) 50.00 mm
7Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor
83 core armoured- 50 sq. mm ( from control room to High Mast light )
92 core armoured - 4 sqmm( for pole to pole & pole bottom to top )
10Armoured 2 core - 16 sq mm ( for street lights power supply )
11Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 90Watt, color temp 3000-6500k as required.
12Supplying and fixing of analog time switch for automatic ON - OFF street light of approved make in existing LT panel including connections etc. as required as per specification
13Supply, fixing, testing & commissioning wall/floor mounted LT panel primer coated with powder coated paint & provided with required gasket for dust/vermin proof with degree of protection IP42 suitable for 415Volt 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) duly compartmentalized for incomer, bus section, outgoings, cable alleys & CT, PT Ampere Metre, Volt Metre, selector switches, frequency Metre, phase indicating lamp, Energy Metre complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs, ACB, panel mounted changeover switch/SFUs, etc. as required but excluding cost of busbar strips, Ampere Metre, Volt Metre, selector switch as per approved design & specification
14Supply and fixing of LT panel accessories of approved make in existing LT panel including connections etc. as required as per specification. 11.01 Digital Ampere Metre with CTs with selector switch
15Digital Volt Metre with selector switch & HRC fuse
16Frequency Metre Frequency Metre
17Copper bus bar strips Copper bus bar strips with PVC sleeves
18LED lamp indicator LED lamp indicator
19Supplying, erection and testing of approved make electric Ceiling fan of double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts including connections with all necessary material complete of approved as required confirming to IS :374/2019 with upto date amendments.Ceiling Fan (ISI marked)-1200 mm Sweep, with minimum air delivery 210 m³/min and service value ≥ 4.00 as per BEE.
20Supply and fixing of approved make flush type step type electronic fan regulator including connection etc. as required on existing board 100W
21Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. 'J' type (EN8 grade) complete, erected in an approved manner on provided foundation. 7 meter height, 130 X 70mm A/F, 220x220x12mm base plate having weight 60 kg ± 3%, 4 nos. X 20 x 700mm bolt having weight 7.7 kg ± 3%.
22Providing and fixing of sword canopy type single arm GI bracket upto 2 meter Long for 70mm A/F top octagonal pole
23Supply, installation, testing and commissioning of G.I. cross over/junction box for duct entry 1/3 compartments junction box c/w fly overs (frame & trap) including all necessary civil works. 225 x 225 x 65 - 90 mm
24Supply and erection of hot dip G.I. cable tray perforation not more than 17.5% for specific dimensions along with tees, bends. The cable tray shall be hang from ceiling/ fixed to wall with necessary angle/flat iron/hanging rod, for ceiling suspensions, clamp, anchor fastener, nuts, bolts, washers, not more than 1.0 mtr. apart complete as per specification to complete the job. The tray shall be as follows :-300 x 50 x 1.6mm thick
25Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge.
26Supplying and fixing of 32mm dia. X 2.00 meter long G.I. pipe (medium class) bracket for mounting of fluorescent/S.V/M.H/L.E.D lamp street light fittings on poles including bending the pipe to the required shape and wiring with 1.5sq.mm W.P./PVC wire etc. as required.
27Supply & fixing fencing of chain link mesh 100 x 100 mm, 12 SWG GI wire for for D.P. structure electric sub-station switch yard including single post of angle iron size 50x50x5mm, 2.5 mt long should be provided upto 2.00 mt. apart or as required. The panel frame with required angle iron/ flat iron members/cross members including mesh welded in frame panel shall be erected between the posts. The angle iron post shall be erected in cement concrete M-15 (1:2:4) (20 mm graded metal) foundation, including excavation of pit and refilling the same. The fencing shall be provided with one entrance gate including locking arrangement as required as per specification. The height of fencing shall be 2 mt. above ground level. Fencing shall be painted with required shade. (to avoid illegal entry of people on the top of Dam from both side of entry point. 22 mtr length from right side + 30 mtr form left entry point = total 52 metre length ; i.e. 52x2 =104 sqmt.)
28Supplying of ISI marked iron clad/metal clad triple pole and neutral switch fuse unit with two earthing terminals & without HRC fuses – 100Amp 415/500 Volts. (1 for Dam Top light and 1 for dam approach road light)
29Supplying and erection of water tight terminal box made of 16 SWG M.S. Sheet (1.6mm thick) i/c rubber gasket of required size suitable for kit kat/MCB/switch including 2 nos. pole clamp of M.S. flat iron size 32x3mm, nut and bolts, The box shall be powder coated excluding the cost of the kit kat/MCB/Switch 4 Pole epoxy connector nut & bolt type, 30Amp, 500Volt complete as per specification as mentioned below. 20x15x10 Cms
30Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per MPMKVVCO. Specification.
31Supply of rubber mat 2 x 1.0Mtr, 1100V tested
32Supply of hand gloves 11KV tested
33Supply of first aid box complete with medicine & bandage as per specification.
34Supply of shock instruction chart duly framed with glass, as reqd.
35Supply, installation, testing and commissioning of surge arrester for protection of DC side(420V to 1,200V) of systems in photovoltaic applications upto Imax 30 KA, 8/20 µs and protection level of 2 KV. Short circuit withstand current of 125 A. Has visual indication of healthy/replace status onboard and remote, with replaceable modules and complies with EN 50539-11:2010
36Supply, installation, testing and commissioning of Pure sine wave Inverter , Display Indications (Status, Fault conditions and Battery Charging) ,Standard Voltage range from 100 V~ 300 V , High Peak Current Handling Capability & High Voltage Surge Protection excluding battery and wiring for connections. 1.2-1.5 KVA
37Supply, installation, testing and commissioning of 12/24 V Battery system in series/parallel combinations or as single as per requirement including interconnetion wiring, lugs and other required material as required with maunting stand/trolley, warranty period: Minimum 3 year 180/200 AH, Tall Tubular
38Supply, Installation testing and commissioning of red colour aviation light LED integral type comprising of aluminium powder coated housing with polycarbonate enclosure IP 65 on existing pipe/support including connection, testing etc. as required. Guarantee as per tender agreement condition. 20 watt (300 LED)
39Supplying, erecting and testing of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250 complete connection and including, frame bolt/anchor hole fasteners etc. complete finished and as required. 300mm sweep RPM 900 / 1400
40Supplying of PVC Body Desert coolers/ Tower Cooler / Window cooler operating at 230 V and 50 Hz Supply, with submersible pump, Fan motor with regulator, woodwool wall pads/Honeycomb type wall pad, without stand. Manul operating type with Tank capacity 51-55 ltrs, Air delivery 2000 cubic metre/hr
41Supply and fixing Led tube rod comprising of LED tube with non- integral/integral driver, upto 6500K color temp having 40000 burning hrs life with minimum @ L 70, system lumen output should be minimum with system efficacy> 100 lm/Watt. LED driver PF> 0.95 & THD < 20%. The colour rendering index of LED light should be more than 70. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. Tube light LED 1 X 20/22Watt, Integral i/c batten aluminium body, PC diffuser.
42Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for:35.1 3 module pvc box
434 module pvc box
448 module pvc box
45Supplying and fixing PVC casing and capping (double fold) ISI marked along with accessories on surface etc. as required PVC casing and capping (double fold) 25 mm x 12mm
46Supply of XLPE insulated FRLS heavy duty power cable conforming IS-7098 (Part-1) 1988, 1100 Volt grade, 2/3/4/8/10/12 core ISI marked with copper stranded/solid conductor. Armoured 2 core- 2.5 sqmm
47Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 300Watt, color temp 3000-6500k as required.
48Earthing with G.I. earth plate 600mm X 600mm X 6mm thick including accessories and providing masonry encloser in cement mortar, cover plate having locking arrangement on the top and G.I. watering pipe 20mm dia 2.7 metre long etc. (but without charcoal or coke and salt) complete as required
49Add extra for using salt and charcoal/coke for G.I. plate or copper plate earth electrode as required including excavation and refilling the pit in all type of soil, murrum
50Point wiring (excluding metallic switch box & sheet but including switches, sockets, lamp holders/ceiling roses etc) with 1.5sq. mm. PVC insulated cable FRLS with copper multi strand conductor ISI marked in Surface rigid P.V.C. casing and caping ISI marked of suitable size and 1.5sq. mm. PVC insulated FRLS copper earth continuity conductor of green colour inside casing & capping screwless connector for joints etc. as required as per specification for41.1 Primary short point
51Primary medium point
52Primary long point
53Supplying and fixing flood light with high power LED of 3 to 6 Watt each assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt.luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF > 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79-08/IS16106 (2012), IEC60598, IEC61347i/c connection wire, testing etc. to complete the job. 150Watt, color temp 3000-6500k as required.
54Laying of underground cable armoured./unarmoured as per specification in air suspended on existing approved type of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete. 16 sq. mm. 1/2/3/4 Core cable upto 16 sq. mm
55Fixing of street light bracket of required angular shape and size pipe bracket on wall/pole including M.S. clamp not less than 40X5mm flat, nut, bolt 12mm of required length with necessary material including connection 3 core flexible wire etc. complete as required excluding cost of pipe paid separately.
56DG SET WATER COOLED:-Supply, installation, testing and commissioning of 'Silent Type' diesel generating set comprising with diesel engine water cooled, Synchronous alternator, AMF control panel single/three phase, acoustic enclosure, battery with charger and related accessories including incoming cable 10 mtr, exhaust pipe 'B' class with insulation as per CPWD specification and CPCB - IV Norms. Note:- 1. Two No Cu plate (600mmx600mmx3mm) earthing and Two No GI plate (600mmx600mmx6mm) earthing with GI/Cu Strip to be done for each installation as per specification and will be separtely paid. 2. Suitable size of PCC/RCC plateform to be made seprately as per requirement and instruction of Enguineer-in-charge. Supply, installation, testing and commissioning of diesel generating set three phase, water cooled with AMF control panel, 25 KVA, 415V.
57Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor unarmoured 4 core with 50 sqmm
58Supply, Installation, Testing & Commissioning of complete SCADA System for 9 Nos. Radial Gates (rope‑drum) – PLC Panels, Field Instruments, Cables, Electrical Installation, Operator PC & 65‑inch Screen
598 MP IP IR fixed lens bullet camera - Supply, installation testing and commissioning of the IP bullet camera shall be equipped with a 1/2.5′′ 8 MP progressive scan CMOS imager to capture ultra HD 4K/8 MP resolution at 15fps or3 MP at 25/30 fps, a 4.0 mm fixed lens,and a waterproof (IP66) IK10 impact-resistant camera housing, as a true day/night solution, the camera shall use smart IR technology and provide up to 98 ft (30 m) of IR illumination. The camera shall accept PoE (802.3af) or 12 V DC power input. min. illumination:0.07 lux (color)/0 lux (B/W) @ F2.0 (with IR LEDs on)) video compression :- H.265 , noise reduction: 3DNR,Backlight Compensation :- DWDR, angle of view horizontal: 88° vertical: 48°,UL listed
604 Pair shielded twisted pair (STP)- Supplying and drawing 4 pair shielded twisted pair (STP), 0.5 mm PVC insulated copper conductor un-armoured Cat-6 computer cable FRLS in existing surface/concealed,steel/PVC.conduit / casing-n- capping as required.
6116 channel NVR with 4 SATA- Supply, installation testing and commissioning of 16 channel NVR with 1080p real-time live view H.265/H.264MJPEG dual codec decoding Up to 12 MP resolution preview & playback max 320 MBPS incoming bandwidth support 4 SATA HDDs up to 32TB, supports fisheye video de-warping in local and web user interface, supports visual or auditory notifications(a flashing light, bell, or siren) complete with UL certification
62Hard Disk - 4 TB Providing & fixing of 4 TB hard disk
63CCTV colour monitor- 32\\" flat LED colour Monitors Supply, installation, testing and commissioning of 32\\" flat LED colour monitors
64G.I. pipe for protection of underground cable - Supplying & installing G.I. pipe for protection of underground cable fixed on wall/ support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendant for light luminaries /fan/ protective for earthing, lightening conductor down strip/overhead service line/for submersible cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, tee, elbow, nuts and bolts etc. complete in an approved manner as required to complete excluding cost of excavation/dismantling & other finished masonry Item complete. For 'B' class pipe ISI marked (IS-1161-68) 50.00 mm
65Supply, installation testing and commissioning of High-Speed HDMI corrosion - resistant connector & braided cable, Supports Ethernet, 3D, 4K video, computers and other HDMI enabled devices Black as required to complete the job as mentioned below 15 Metre, HDMI cord
6620 Metre, HDMI cord.
67Supply, installation testing and commissioning of wall mounting rack, for computer switches/Patch Panel etc complete as mentioned below :- 6U cabinet with min. Dimensions 366X600X600, wall mounting with 6 point 5 Amp. socket power supply strip, and fan, cable manager, tray as per Site requirement
68Supply, installation, testing and commissioning of UPS with isolation transformer & battery for backup, minimum load power factor 0.8,power factor 0.99, having OVCD (over voltage cut-off device), having CVCF (constant voltage constant frequency, bypass parameters configurable, 2 stage charging(constant current/float charge), having temperature compensated charger, Fan speed control, digital signal processor controller, total harmonic distortion (current)-THDi (<10%@50% R Load, Input 1 phase voltage 230v, voltage range 110-300v, Output voltage (220AC/230AC/240AC ± 1%), Total harmonic distortion Voltage (THDv- <3% linear load, <5% nonlinear load, 90 % AC/AC efficiency, Over load capacity(105-110%: 3min, 111-130%: 30Sec), operating temperature with full load 0-40°C, communication features (RS232, USB com port, Intelligent slot(optional). UPS installation with all required material arrangements as required as per IS specification.1 KVA (1 phase input & 1 phase output)For 30 minute backup, min. 800 VAH
698 port PoE switch with 2 SFP portsSupply, installation testing and commissioning of 8 port PoE switch with 2 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP cat. 5, cat. 5e (100 m max.), full/halfduplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 40 GBPS, maximum 64 bytes packet forwarding rate, 14.88 MBPS, ports 1 to 8 compliant with 802.3at
70Supplying and fixing of approved make modular type PVC box minimum depth 40mm and minimum thickness 2mm with modular base and cover plate including fixing on surface etc. as required for: PVC box 1 Or 2 module - 1 Or 2 Module PVC box
71Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor Armoured 3 core - 6 sq. mm. ( for CCTV Camera power input )
72Providing and erection of hot dipped galvanized octagonal poles in single section made from 3mm thick sheet having lockable weather proof flush door junction box, suitable size & type of foundation bolts 4 nos. 'J' type (EN8 grade) complete, erected in an approved manner on provided foundation. 7 meter height, 130 X 70mm A/F, 220x220x12mm base plate having weight 60 kg ± 3%, 4 nos. X 20 x 700mm bolt having weight 7.7 kg ± 3%.
73RJ-45 computer jack (2Module):- Supply, installation testing and commissioning RJ - 45 computer jack cat 6 with shutter modular (2Module)
74Supply and erection of hot dip G.I. cable tray perforation not more than 17.5% for specific dimensions along with tees, bends. The cable tray shall be hang from ceiling/ fixed to wall with necessary angle/flat iron/hanging rod, for ceiling suspensions, clamp, anchor fastener, nuts, bolts, washers, not more than 1.0 mtr. apart complete as per specification to complete the job. The tray shall be as follows :-300 x 50 x 1.6mm thick
75Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, shuttering, curing etc. with existing foundation bolts complete as per specifications in an approved manner as per manufacturer drawing or engineer-in-charge.
76Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per MPMKVVCO. Specification.
77Laying of underground cable armoured./unarmoured as per specification in air suspended on existing approved type of iron clamp, G.I wire 7/1.6mm & shackle insulator/insulated strip complete. 16 sq. mm. 1/2/3/4 Core cable upto 16 sq. mm Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57788579
AUTHORITY Government Departments
TENDER VALUE 1.75 Crore
LAST DATE 20-11-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Replacement Of Rubber Seal And Epoxy Painting Work On Radial Gates And Other Electrical And Mechanical Work Of Kaka Sahib Gadgil Dam Under (Drip-Ii).
Basic Detail
Tender No 1234/2026-27/Einc/Etendering/ dt.06-08-2026
Bidding Type Tender
Location
City Ujjain
State Madhya Pradesh
Key Dates
Publish Date 15 Oct 2026
Submission Date 20 Nov 2026
Open Date 01 Jan 0001
Finance
Tender Value 1.75 Crore
Tender Fee 5000
EMD 3.50 Lakhs
Exemption Not Available
Document List
525967.pdf
a04bb052-9996-4bc8-b154-4190305dbf61.html
BOQ_638374.xls
LoFB.pdf
Tendernotice_1 (23).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 02, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 10, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 20, 2026
18:00 IST

Corrigendum-4 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 20, 2026
18:00 IST

Corrigendum-5 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 20, 2026
18:00 IST

Corrigendum-6 Issued

Clarifications on tender conditions and amendments issued.

Today
Nov 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today

Tender Documents

Download All (ZIP) ↓
pdf

525967.pdf

html

a04bb052-9996-4bc8-b154-4190305dbf61.html

xls

BOQ_638374.xls

pdf

LoFB.pdf

pdf

Tendernotice_1 (23).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender