Tender for Construction And Management Of Night Shelter (Revenue). Sub-Head:- Augmentation, Maintenance And Cleaning Of Existing Bio Digester Tanks And Providing And Fixing Of Bio-Digester Tanks And Frp Fencing Around Existing Bio-Digesters Tanks Installed In Various Night Shelters Under Jurisdiction Of E-03 Division.
BOQ
| Sl. No. | Item Description |
| 1 | Recharging of bio- digester tank with bacteria inoculums (based of DRDO technology)(M.R.) |
| 2 | S/f of PVC type following accessories i/c making water tight connection etc. as regd.(M.R.) |
| 3 | S/F of P-Trap 110mm dia |
| 4 | S/F of Elbow 110mm dia |
| 5 | S/F of Socket 110mm dia |
| 6 | S/F of End cap 110mm dia |
| 7 | S/F of Tee 110mm dia |
| 8 | Supply and fixing of PVC pipe of size 110mm 6kg/sq.cm i/c dismantling the old pipe complete as reqd.(M.R.) |
| 9 | Cleaning of bio-digester tank complete from out side and inside i/c removal of sludge in solid/liquid stage so as to make the tank in funtional as reqd.The rate is inclusive of all required labour and machinery i/c nut bolt (SS)(M.R.) |
| 10 | Maintence contract of bio-digester toilet of various capacity i/c minimum weekly inspection and preventive maintence activity by engaging suitable labour i/c fitter & sweeper as reqd so as to ensure adequate working of the system (Total 30 nos Night shelter by deploying suitable manpower.)(M.R.) |
| 11 | Repair of damaged FRP Bio-diegester tank cover by fibre glass, resin putty etc as required upto capacity of 5000 Ltr tank (MR) |
| 12 | Providing and fixing of FRP fencing including civil work at underground bio - digester tanks with necessary excavation concreting for grouting vertical posts upto 300 mm in ground, hardware, accessories, fitting, lock etc. complete as shown in drawing enclosed. The fencing shall shall comprise of one gate of 1000 mm having two flaps in the existing installed bio digester tanks at night shelters under the jurisdiction of E-3 division. |
| 13 | Providing & fixing of FRP moulded four chambers sludge tank of size 2x1.20x1.50mtr with 5mm thickness internal with ribs for more strenght & capacity 3600 ltrs. The tank will contain a gas outlet pipe of 25mm diameter including connection from cubicles to biodigester tank with PVC/FRP pipe fittings of 110mm diameter as required & biodigester tank is also connected with PVC/FRP outlet pipe of 50mm diameter with standard plumbing arrangement. Each segment of tank on inner & side walls will contain PVC matrix/other suitable arrangements to enhance the surface area for bacterial attachment. Each section will contain PVC embedded FRP mesh each partition wall will be provided with PVC pipes of approximately 110mm diameter. Microbial Consortium/Bacterial Inoculum (technology developed by DRDO) & biomedia, additives as required for effectives working of bio digester shall be provided in tanks as of specific grade & required periodically for the minimum period of One (1) year from the commencement of the biodigester. Biodigester generates absolutely clear odour less water with COD>250mg/ltrs, BOD>30mg/ltrs. Specifications & designs as direction of Engineer-in-charge. Rate are inclusive of first year maintenance cost and replacement if any. |
| 14 | S/f of Nut & bolt set M6 x 50 mm Hex Head screws, Hex Head bolt with Nut & washer zink coated with 3 mm head etc as required for suitable size of biodigester tank as required. |
| 15 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m & lift upto 1.5m, disposed earth to be levelled & neatly dressed. |
| 16 | (i) All kinds of soil |
| 17 | Providing & laying in position cement concrete of specified grade excluding the cost of centering & shuttering-All work up to plinth level. |
| 18 | (i) 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) |
| 19 | (ii) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 20 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation & plinth in: |
| 21 | (i) Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 22 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming & watering, lead up to 50m & lift upto 1.5m. |
| 23 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer using structural steel etc. as required. |
| 24 | (i) In gratings, frames, guard bar, ladder, railings, brackets, gates & similar works |
| 25 | Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design |
| 26 | Correction factor on Civil DSR 2023 @ 0.973 (S. No. 10 to 15 |
| 27 | Add 3 % cofficient of Civil DSR 2023 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender