Tender for Various Repair And Maintenance Works At Burari Pump House, New Delhi
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 2 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering as required and as directed- All work up to plinth level:1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | 1:5:10 (1 cement: 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(for shed,gates etc.) as required and as directed. |
| 5 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(for shed,gates etc.) as required and as directed.Hot finished seamless type tubes |
| 6 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 20/22 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(for both sheds) |
| 7 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) |
| 8 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws completeGutter (600 mm over all girth) |
| 9 | CEMENT PLASTER (IN FINE SAND) 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand) |
| 10 | Dismantling of 01 no. non-operational electrical panel and 03 nos. damaged/non-operational starters (total 01 job) including safe disconnection, handling, shifting, and stacking at the designated store room within Burari Pump House premises |
| 11 | Dismantling and removal of 03 Nos. old, non-operational/defective electrically driven pumps installed on concrete foundations, including cutting, disconnection, lifting using hydra crane,heavy duty labour T&P, gas cutter etc. as required and shifting to the designated store within 100 m. |
| 12 | Fabrication/Making and Installation/ connection of M.S Dead Flange for closing of main body from top to make hole by gas cutter at side and rubber packing, nut bolts to closed the main body of old existing sluice valve to make leak proof arrangement in order to cover the entire cross section (round) with flange. |
| 13 | Charges for chain pulley block, fitter/welding grade and tripod for lifting and workign of the old rusted sluice valve/GI pipes/other dismantled parts of the pump etc. from the chamber along with accessories tools as required by Engineer-Incharge. |
| 14 | Charges for gas cutting machine with LPG and Oxygen gas for cutting the dusted MS nuts and bolts etc. with operator |
| 15 | Removing mud, garbage, hyacinth silt etc. from the chamber of connecting pipes and sump of the pump house with the help of heavy duty labours and dispose within 50m. |
| 16 | Filling E.C Bags with available good earth and stacking upto a lead of 50 meters as per direction of Engineer-in-Charge This item is for stopping the flow of water as per the requirement for keeping the working area dry so that the repairing/replacement work of gates, channel, grooves, finishing etc. can be carried out at Burari Pump House for effecient and smooth operation of dismantling & shifting the pumps. |
| 17 | Dismantling of 03 Nos. existing non-functional/non-operational inlet (suction) pipes and 01 No. non-functional/non-operational outlet/delivery pipe affected due to clogging, including cutting and removal of damaged/rusted M.S. pipes, sheets, channels, etc., using gas cutter, grinder, and required tools. Work includes disposal/stacking of dismantled material and refilling of excavated area with cement concrete (CC) to prevent leakage, complete in all respects as per directions of Engineer-in-Charge. |
| 18 | Repair of window frame located in pump house shed, including dismantling of damage/obsolete glass/fibre sheets and providing & fixing new transparent fibre sheet (approx. 4 ft × 3.5 ft for both casement/sides). Work includes welding, grinding, alignment, fixing with M.S./S.S. clamping strips, nuts, bolts, washers, painting with red oxide primer and enamel paint, and refitting of window, complete in all respects as per directions of Engineer-in-Charge. |
| 19 | Repairing and Re-fixing of MS structural pump foundation (base frame) using ISMB/ISMC steel sections, including cutting, welding, alignment, anchoring, and grouting on RCC foundation for electric pump at Burari Pump House, complete in all respects as per direction of Engineer-in-Charge(including dismentling if required). The refixing shall be on the existing induction motor on the existing base frame, including proper all greasing, oiling and painting with proper alignment with the centrifugal pump, refixing of tyre-type flexible coupling, providing and fixing new connection plate, replacement of damaged/broken nuts and bolts (if required), including cartage of motor from site to workshop and back to site,(if requires) and complete testing and commissioning on full load, all as per direction and entire satisfaction of Engineer-in-Charge |
| 20 | Supplying and replacing the bearings for 180/150 HP pump sets at Burari Pump House, including supply of bearings, installation, testing, commissioning, labour, tools, consumables, and all incidental charges, complete as required.Pump Bearings:Bearing No. 6412 – 2 Nos. (Make: SKF/NBC/FAG)Bearing No. 51314 – 1 Nos. (Make: SKF/NBC/FAG)Motor Bearings:Bearing No. NU319-E-XL-M1-C3 – 2 Nos. (Make: SKF/NBC/FAG)Bearing No. 6316-C3 – 2 Nos. (Make: SKF/NBC/FAG)The rate shall include: Dismantling of existing bearings, supply of new bearings, fitting, alignment, reassembly, lubrication, testing, commissioning, labour, transportation, tools & tackles, and all other incidental charges required for satisfactory completion of the work. and also include gland adjustment/change as required in the process. |
| 21 | Repairing, greasing, oiling, and proper alignment of 02 Nos. large shutters, including strengthening of weakened portions by welding, and providing & fixing an adequate locking system to ensure smooth operation and safe closure, complete in all respects as per direction of Engineer-in-Charge |
| 22 | Repairing, greasing, oiling, and proper alignment of 04 Nos. small shutters, including structural strengthening by welding at weak/damaged points, and providing & fixing an adequate heavy-duty locking system to ensure smooth operation, proper closing, and safety, complete in all respects as per direction of Engineer-in-Charge. |
| 23 | Repairing and maintenance of 03 Nos. electrical starters installed at Burari Pump House, including inspection, cleaning, tightening of electrical and mechanical connections, replacement of minor defective components (if required), and ensuring smooth and safe operation, complete in all respects as per direction of Engineer-in-Charge |
| 24 | Repairing, servicing, and maintenance of 01 No. LT panel installed at Burari Pump House, including internal cleaning, tightening of all electrical connections, checking of protection devices, replacement of minor defective components i.e MCCB, MCB, ELCB etc. (if required), and ensuring safe and proper operation of the panel, complete in all respects as per direction of Engineer-in-Charge |
| 25 | Scrapping, Cleaning, Greasing & Painting of all the frames of shed inlcuding truss, purlin and MS Sheets/channels,all the existing shutters, Main Gates, and doors of the store rooms, platform, panels and minor civil structures and other parts, etc as required and directed with ISI approved paint etc. minimum two or more coat of paint after applying primer redoxide etc. and greasing and oiling of complete gates inner and outer including side channels spindle and nut and bolt etc. complete in all respect as per direction of Engineer-in-Charge. |
| 26 | Hiring of DG Set, welding set, drill machine, gas cutter, Hilti cutter and other T&P for shed work and minor mech/civil repairing at various Inlet Gates of Supplementary Drain |
| 27 | Taking out of following capacity/type fire extinguishers from the vaious laoctions on hanging stand(or as situated/installed), removing the old gas/other extinguisher material from the cylinder at site hydraulic pressure at work shop and refilling the new gas/catridege/other extinguisher material required i/c pasting stickers, reinstallation of cylinder at their position as requiredCO2 type fire extinguisher 4.5 k.g capacity |
| 28 | Taking out of following capacity/type fire extinguishers from the vaious laoctions on hanging stand(or as situated/installed), removing the old gas/other extinguisher material from the cylinder at site hydraulic pressure at work shop and refilling the new gas/catridege/other extinguisher material required i/c pasting stickers, reinstallation of cylinder at their position as requiredCO2 type fire extinguisher 9/18/22.5 k.g capacity |
| 29 | Taking out of following capacity/type fire extinguishers from the vaious laoctions on hanging stand(or as situated/installed), removing the old gas/other extinguisher material from the cylinder at site hydraulic pressure at work shop and refilling the new gas/catridege/other extinguisher material required i/c pasting stickers, reinstallation of cylinder at their position as requiredAB C type extinguishers 4.5 k.g./6k.g. capacity |
| 30 | Taking out of following capacity/type fire extinguishers from the vaious laoctions on hanging stand(or as situated/installed), removing the old gas/other extinguisher material from the cylinder at site hydraulic pressure at work shop and refilling the new gas/catridege/other extinguisher material required i/c pasting stickers, reinstallation of cylinder at their position as requiredAB C type extinguishers 6 k.g./9k.g capacity |
| 31 | Supplying of 4.5 Kg capacity CO2 type Fire Extinguisher at various location in Burari Pump Houseas per direction of Engineer-in-Charge(Life Guard/Omax/Minimax with ISI Marked) |
| 32 | Supplying of 06 Kg capacity ABC type Fire Extinguisher at various location in Burari Pump Houseas per direction of Engineer-in-Charge(Life Guard/Omax/Minimax with ISI Marked) |
| 33 | Providing 1HP monobloc pump with size 25*25 mm, Head range 6-32m, Discharge range 2880-500 LPH, Rate Voltage 220V, Power 0.75KW/1HP, Single Phase at Burari Pump House (Make:- Kirsolkar, Crompton, ABB) |
| 34 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 35 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender