Tender For Repair/Maint Of Acb, Mccb, Junction Boxes, Loop In/Out Boxes Control Panels And Ug Cables And Connected Work At Smqs And Omqs Of Afs Yelahanka.
Tender Value
45 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Acb, Mccb, Junction Boxes, Loop In/Out Boxes Control Panels And Ug Cables And Connected Work At Smqs And Omqs Of Afs Yelahanka.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed . |
| 3 | Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 4 | Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm complete all as specified and as directed. |
| 5 | Supply and laying in trenches, LT underground cable of size 16 Sqmm 4 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed .Note :- Necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 6 | Supply and laying in trenches, LT underground cable of size 25 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed .Note :- Necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 7 | Supply and laying in trenches, LT underground cable of size 35 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed.Note :- Necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 8 | Supply and laying in trenches, LT underground cable of size 50 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 9 | Supply and laying in trenches, LT underground cable of size 70 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 10 | Supply and laying in trenches, LT underground cable of size 95 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 11 | Supply and laying in trenches, LT underground cable of size 120 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 12 | Supply and laying in trenches, LT underground cable of size 240 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 13 | Supply and laying in trenches, LT underground cable of size 300 Sqmm 3.5 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-charge.Note :- necessary excavation and connected items shall be measured and paid separately under respective items of this schedule. |
| 14 | Material & Labour for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including GI pipe of 50/80/100mm dia suitable for 0.4mpa working pressure complete all as specified and as directed.. |
| 15 | Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. |
| 16 | Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and as directed. |
| 17 | Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 30 cm x 20 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 50x50x3 mm, angle height 75 cm, (30cm below ground level and 45 Cm above ground level ) with PCC 30cmx30cmx 30cm all as specified and as directed. |
| 18 | Supply, installation and commmissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coars of syntehtic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 16 KA as incomer including taking down old terminal boxes complete all as specified and directed . |
| 19 | Supply and fix in repair bus bar box of size 450x300x500mm fabricated by 3 mm thick MS sheet outdoor type, dust/vermin proof, mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr, erected in ground with PCC foundation 1:4;8 with 40mm stone aggregateand including aluminium bus bar flat of size 50x6 mm fixed as bus bar over the insulators, sleeved for three phase and neutral and spray painting the box with two coats of enamel paint over a coat of metal primer including necessary excavation, PCC for fixing the box complete all as specified and directed . |
| 20 | Supply, install, testing and commissioning of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 500 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: INCOMINGMCCB 4 pole 315 Amps ,with thermal and mangnetic setting,35 kA - 01 Nos OUTGOINGMCCB 4 pole 200 Amps ,with thermal and mangnetic setting, 25 kA - 01 NosMCCB 4 pole 125 Amps , with thermal and mangnetic setting, 25 kA - 01Nos MCCB 3 pole 63 Amps , with thermal and mangnetic setting, 16 kA - 01 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set of three for each outgoing and incoming MS work incl angle iron frame and PCC workSpace for mounting of additional MCB In future.Internal wiring including copper lugsNote: Bottom portion of the Panels should minium 45 cm above the ground level |
| 21 | Supply, install, testing and commissioning of LT Panel board CPRI approved outdoor type, floor mounted, factory made suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with aluminium bus bars duly insulated by insulation of RYB colour 500 Amps rating mounted on porcelain insulators .The panels shall be factory made, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 50X50X5 mm duly embedded in PCC platform and duly powder coated with 7 tank process with colour as directed including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable all as directed at site and comprising of the following: INCOMINGMCCB 4 pole 160 Amps 35 kA with thermal and magnetic settings - 01 Nos OUTGOINGMCCB 4 pole 125 Amps 25 kA, with thermal magnetic settings - 01 NosMCCB 4 pole 63 Amps 16 kA - 01 Nos MCB DP 32 Amps 16 kA - 01 Nos Multifunctional VAF meter, PF meter - 1 No RYB Neon indicating lamp -1 set of three for each outgoing and incoming MS work incl angle iron frame and PCC workSpace for mounting of additional MCB In future.Internal wiring including copper lugs |
| 22 | Fabricate, supply ,install testing and commissioning of LT panel intdoor type 415 Volts, 50 Hz, 3 phase, 4 wire for accomodating the following accessories totaly enlosed self supporting structure fully compartmentalized suitable for indoor use with bottom cable entry with suitable cable glands made out of CRCA sheet 2mm thick with angle iron frame works with suitable legs of ISA 50x50x5mm with four legs grouted PCC (1:2:4) type B1, foundation block with suitable monting arrangement for aluminium bus bars 400 Amps capacity, hindged door at front with suitable locking arrangement, provision of louvers at sides, CPRI approved, dust and vermin proof, powder coated and with following asseccories suitable for incoming/outgoing arrangements complete all as specifed and directed(a) 4 Pole MCCB 250 Amp, 50 Hz, 415 V,36 KA , with thermal and mangnetic setting , Incomer -1 No(b) 4 Pole MCCB 200 Amp, 50 Hz, 415 V,25 KA with thermal and mangnetic setting , Incomer, -01 No(c) 4 Pole MCCB 160 Amps 50 Hz 415 V, 25 KA with thermal and mangnetic setting , Incomer-01 nos (d) SPN MCB 32 Amp , 10 KA-01 Nos (e) Digital VAF meter -01 No(f) CT's 200/5- set of 3 No(g) LED type Indication lamps (RYB)-one set with each incoming and outgoing |
| 23 | Supply and fix in repair MCCB 400 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed . |
| 24 | Supply and fix in repair MCCB 350 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed. |
| 25 | Supply and fix in repair MCCB 200 Amps, 4 pole 36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed . |
| 26 | Supply and fix in repair MCCB 125 Amps 4 pole 25KA, adjustable thermal setting complete all specified and directed . |
| 27 | Supply and fix in repair MCCB 100 Amps 4 pole 25KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed . |
| 28 | Supply and fix in repair MCCB 63 Amps 4 pole 16KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed . |
| 29 | Servicing, cleaning and repairing by dismantling and taking out air circuit breaker 400/630/800 amps capacity 3 pole 415 volts 50 Hz and removing mechanical assembly fixed and moving contact set and replacing mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed .Note:- Replacement of unserviceable electrical parts will be measured and paid for separately under relevant items of this schedule. |
| 30 | Supply & fix contact assembly fix type for 630/800 Amps 3 pole 415 volts ACB all as specified and as directed. |
| 31 | Supply & fix contact assembly fix type for 400 Amps 3 pole 415 volts ACB all as specified and as directed . |
| 32 | Supply & fix moving contact assembly for 630/800 amps 3 pole 415 volts ACB all as specified and as directed . |
| 33 | Supply & fix moving contact assembly for 400 amps 3 pole 415 volts ACB all as specified and as directed . |
| 34 | Supply & fix pole assembly for 630/800 amps 3 pole 415 volts ACB all as specified and as directed . |
| 35 | Supply & fix pole assembly for 400 amps 3 pole 415 volts ACB all as specified and as directed |
| 36 | Supply & fix Arc chute for 630/800 amps 3 pole 415 volts ACB all as specified and as directed |
| 37 | Supply & fix Arc chute for 400 amps 3 pole 415 volts ACB all as specified and as directed |
| 38 | Supply & fix charging motor for 630/800 amps 3 pole 415 volts ACB all as specified and as directed . |
| 39 | Supply & fix charging motor for 400 amps 3 pole 415 volts ACB all as specified and as directed |
| 40 | Supply & fix control relay for charging motor for 630/800 amps 3 pole 415 volts ACB all as specified and as directed. |
| 41 | Supply & fix control relay for charging motor for 400 amps 3 pole 415 volts ACB all as specified and as directed. |
| 42 | Supply and fix in repair glow signage boards with base frame made from angle iron and backside form ACP sheet 3mm thick with IP 68 Protection LED module , good quality virgin monomer Acrylic sheet , MES Logo & Southern Command logo in letters with 5 mm sun board channel , including complete wiring and power supply with IP 68 protection , each letter will be made with computer offset for having same letter style and type as approved by Engineer - in- charge , complete all as specified and directed.Note : Layout of display board will obtained from Engr - In - charge before placing the order |
| 43 | Material & Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate in foundation complete all as directed . |
| 44 | Material & Labour for PCC 1:3:6 type C1 using 20mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surface finished smooth and even all of specified. |
| 45 | Supply and fix roof trusses (framed ) trussed , purlins , crane gantries , rails and fastenings and heavy bracket framing (Beam , tee, agnle , channel or falt sections) including distance pieces , cleates etc Fe -410W (gde -E--250) quality A complete all as specified and directed |
| 46 | Material & Labour for plates (Planeor chequered ) Channel square cut or notched (Ordinary and counter sunk) forming holes with reiveted bolted attachement complete all as specified and directed. |
| 47 | S/F bands straps , clamps cleats and small articles , support or stay for rainwater ventilating pipes inclduding bolts etc conforming to Fe-290Gde -E-165 complete all as spcecified and directed. |
| 48 | S/F Mild steel screw machine made with hexagonal or square heads at one end and secrewed both ends screwed end to end fitted with washer and one hexagonal or square nut length exc 5 cm but n exc 10 cm neck dia 5 to 10mm complete all as specified and directed. |
| 49 | S/F for prepainted galvanium aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength 550mpa as in roof covering / cladding to wall , fixed with self tapping screws as specified and directed |
| 50 | Material & Labour for Pre painted galvaume aluminium zinc coating GI Based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mps as in ridge , hip valley gutters , drip and straight flashing with grade of zinc coating 275 (lenth and girth as fixed ) complete all as specified and directed. |
| 51 | Material & Labour for two coats synthetic enamel paint over a coat of red oxide on new iron surface of any description not otherwise described over 10cm including preparation of new or previously untreated surface complete all as specifed and directed. |
| 52 | Material & Labour for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to GI Strip of size 32x6mm upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15 mm dia and 20 mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed. |
| 53 | Material and Labour for maintenance free earthing complete comprising of 17.2 mm dia 3 mtr long Earth electrode of low carbon steel electriode with 250 micron copper bonding, 50 pounds of Ecosafe based environment friendly backfill and suitable clamp, back-fill earthing enhancing compound shoould strictly be a Eco Safe carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive (like in metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed water and set like concrete and should not leach /diffuse into the ground. Back-fill compound shal not mixed with any soil while pouring in the bore hole. Test Certificate as per IEC :62561-7 for Back-fill compound shall be submitted laongwith the material. 17.2 OD SS clamp both side, Eco friendly rust proof heavy duty weather proof Polythylene Earth pit chamber with following dimensions : 254 mm dia (top),330 mm dia (bottom) & 260 mm (height). |
| 54 | Supply and fix in repair 10 mm copper bonded Round steel solid Conductor in compliance with IS/ IEC 62305 and IEC 62561-2. The coating shall be smooth, continuous & free from flux stains(Ring Earthing) should be tested and use exclusively for lightning protection ,earthing system and ring equipotential bonding complete all as specificed and directed . |
| 55 | Supply and fix in repair test link in order to disconnect the earth termination system for enabling measurements. to connect Aluminium round conductor to Ring Earthing complete all as specificed and directed . |
| 56 | Servicing, cleaning and repairing of existing LT panel boards/feeder pillar boxes of various sizes including replacing the unserviceable CTs,Voltmeters,Ammeters,Selector switches, MCBs, MCCBs, indicator lamps etc. all as specified and as directed.Note:(i) Cleaning of inside/outside of LT panels/Feeder pillar boxes shall be done by using through suitable Blower. (ii) Spare parts like CTs, Voltmeters, Ammeters,Selector switches,MCBs,MCCBs,indicator lamps etc shall be measured and paid separately under relevant items of the schedule. |
| 57 | Supply and fix in repair CTs suitable for existing LT panel board of capacity 400 to 630 Amps all as specified and as directed. |
| 58 | Supply and fix in repair CTs suitable for existing LT panel board of capacity 250 to 320 Amps Amps all as specified and as directed. |
| 59 | Supply and fix in repair CTs suitable for existing LT panel board of capacity 63 to 200 Amps Amps all as specified and as directed. |
| 60 | Supply and fix in repair LED indicator lamps (R Y B ) suitable for existing panel all as specified and directed. |
| 61 | Supply and fix in repair digital ammeter 500amps range suitable for mounting existing panel all as specified and directed |
| 62 | Supply and fix in repair digital voltmeter 500 Volts range suitable for mounting existing panel all as specified and directed |
| 63 | Supply and fix in repair selector switches suitable for ammeter/voltmeter all as specified and as directed. |
| 64 | Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 25 sqmm to 3.5x 95 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed . |
| 65 | Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for3.5x 120 sqmm to 3.5x 240 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed . |
| 66 | Supply & fixing in repair shock treatment chart of size 1Mtr x .5mtr printed in English, Hindi and local language , framed on all sides with wooden beeding and glazing with 3mm thick ordinary glass complete all as directed .Note :contractor has get apporoval of layout of Shock treatment chart from Engr In Charge before printing). |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender