Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #57785995

Tender For Provn Of Standby Power Supply To 607 Gd Flt Alongwith 5000 Ltr Water Tank With Iron Stand In Bcr Section At Af Stn Bhuj

Issued by Statutory Bodies & Commissions/Committees · Kachchh, Gujarat
Tender Value
29.35 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
16 days left
EMD
58700
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kachchh → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Standby Power Supply To 607 Gd Flt Alongwith 5000 Ltr Water Tank With Iron Stand In Bcr Section At Af Stn Bhuj

BOQ

Name of Work:- PROVN OF STANDBY POWER SUPPLY TO 607 GD FLT ALONGWITH 5000 LTR WATER TANK WITH IRON STAND IN BCR SECTION AT AF STN BHUJ
Sl. No. Item Description
1Supply, install, testing and commissioning of Diesel Engine driven generating set 100 KVA, 3 Phase, 4 wire, 415 Volts, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosure having silent features such as modular bolted construction with fabrication on imported CNC torret punch machines, nine tank treatment process with pure polyster based powder coating to ensure long life in all weather conditions and for out door application/ installation, integrated design there by facilitating / easy handling installation & shifting of the equipment at site. Compliance standard of DG set should be confirming to IS-8728. The design of integral acoustic enclosure should be any type approved by national Physical laboratory as per Central Pollution Control Board (CPCB-IV) latest norms/ regulation with fuel tank, battery and standard accessories, acoustic enclosure, vibration pad, tools and spare,as provided by manufacturer, PCC foundation size as per recommended by OEM using block masenery type 1:5:8 using 20mm graded aggregate with solid blocks & PCC (1:3:6) foundation concrete, 15 mm thick plaster in 1:4 and 2 coats of cement base paint for minimum hight from GL 1 feet all as specified and as directed with the following specifications :-ENGINE - make Greaves Cotton ,model GPWII-PIV-100 or equivelant model from make specified in Appx B, direct injection, 4 cylinder, In-line 4 stroke,radiator cooled, compression ignited, turbo charged and charged water cooled diesel engine 139 Amp at 1500 RPM and compling with BS 5514/ISO 8528-5 G2 standard :- (i) 12 V electrical starting system consisting of starter motor, charging alternator (ii) Dry type Air cleaner with restriction indicator (iii) In-line Fuel injection system with Electronic Governor (iv) Spin-on Lube oil filter elements (iv) Radiator, Air-to-Air after cooler, pusher fan & fan drive arrangement, Gear driven water pump (v) Sensor for oil pressure, Coolant temperature & level (iv) First fill of Lube oil.ALTERNATOR : Single bearing alternator suitable for continuous operation generating 100 KVA at 1500 RPM, 415 Volts, 0.8 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system confirming to IS/IEC 60034, brushless type, screen protected revolving field, self excited, self regulated through an AVR. The alternator has the following features : (a) ± 1.0% voltage regulation (max) in static conditions (b) IP : 23 protection with insulated class H (c) Permissible overload of 10% for one hour in 12 hours of operation.Features, Functions, Protections(a) 16 character x 2 line alphanumeric LCD display with LED backlight (b) Operator interface (c) Provide a record of most recent fault conditions, Fault history stored in the control non volatile memory (d) Provide Alternator data frequency.
2Provide Engine data- Starting (a) Battery Voltage (b) Engine Temp (c) Oil pressured (d) Engine Hrs runControl includes provision for service adjustment and calibration of DG control function (a) Voltage, frequency selection (b) Meter calibration (c) Configurable input and output set up Power start operates on 12 V DC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Engine Starting - The control system supports automatic engine starting, Primary and back up start disconnects are achieved by battery charging feedback or main alternator output frequency.Controller provide configurable time delay of 0-300 sec to start after remote start signal and time delay of 0-600 secs prior to shutdown after stop signal.Sleep mode increase battery life. Configurable current setting from low to minimize current draw when genset is not working.Engine Protective Functions includes :- Configurable alarm output emergency stop : Annunciated whenever an emergency stop signal is received by the control (a) Low Lube oil pressure warning and shutdown (b) High engine water temperature warning / shutdown (c) Low coolant temp warning (d) sensor failure indication (e) Low and high battery voltage warning (f) Weak battery warning (g) Fail to start shut down (h) Cranking lockout : Control will not allow the starter to engage or to crank the running engine (j) Cyclic cranking : Configurable for the number of starting cycle (1 to 7) and duration of crank and rest periods (k) Alternator Protective functions includes (l) High and Low AC voltage shutdown (m) Under and over frequency shutdown / warning (n) Loss of sensing voltage input shutdownFuel tank( In built fuel tank)
3Supply, install, testing and commissioning of AMF Panel OUTDOOR TYPE suitable for 100 KVA DG set factory made out of CRCA Steel 3.15mm thick Sheet, floor mounted type and front operated type, totally enclosed dust, damp and vermin proof, all doors and joints will be suitable gasketed to form dust and vermin proof. The panel should be powder coated with minimum thickness of 50 microns, after elaborate pre-treatment to form a long lasting characteristic. The control panel will be complete in all respect with fuses, wiring and labels etc, the following will be incorporated in the AMF Panel :-(i)Multifunctional meter digital (Amp+Volt+PF+Hz+KW+KWH)-01 No.(ii) Alternator voltage monitor 01 No(iii) Main voltage monitor - 01 No(iv) Ammeter DG digital - 01 No(v) Voltmeter DG digital - 01 No (vi) Main Power contactor -4 pole of capacity 250 Amps -01 No(vii) DG Power contactor -4 pole of capacity 250 Amps - 01 No(viii) Indicator Lamp - 02 Nos(ix) MCB (For control ckt)-10 Nos(x) Auxiliary Contactor -02 Nos (xi) Automatic battery charger 12 volt -01 No(xii) Terminal O/L relay - 01 No(xiii) Terminals (for control cable)-06 Nos(xiv) One set of copper bus bar of size 25x10 mm. (xv) Main MCCB -4 pole of capacity 250 Amps -01 No(xvi) DG MCCB -4 pole of capacity 250 Amps - 01 No(xvii) Outgoing MCCB -4 pole of capacity 250 Amps - 01 No (xviii) control cable of suitable size -1 Job Note: The required PCC foundation for AMF Panel is included in the rate .
4M&L earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 32x6 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : -(a) Excavation and earth work for electrode in any type of Soil.(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.(e) Requisite quantity of common salt and charcoal.(f) Testing of earthing. (g) GI strip exeeding 7.5 RM will be measured in respective item.
5S&F in replacement Galvanised iron strip 32 x 6mm with saddles and fixing screws etc for roof/down conductor above ground including PVC flexible tubing suitable size for the protection and insulation of strip /joining with rivets, bolts, nuts, washers etc all as directed by EIC complete.
6Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95.0 sq mm 3.5 core,incl providing and crimping of lugs/providing glands of suitable size complete all as specified and directed
7Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50.0 sq mm 3.5 core,incl providing and crimping of lugs/providing glands of suitable size complete all as specified and directed
8Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil ,For laying of pipe/cable/finding out LT cable faults complete all as specified and directed by Engineer-in-Charge.
9Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete ,For laying of pipe/cable/finding out LT cable faults all as specified and directed.
10Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all specified and directed.
11M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
12M & L unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable.all as specified and as directed by Engr-in-Charge.
13Supply, testing and commissioning of LT electrical out door distribution panel board floor mounted cubical type dust proof, weather proof, vermin proof, astehically designed, having at least IP-54 degree of ingress protection, fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of Copper bus bar minimum 300 Amps capacity having suitable cross sectional area, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including provision of angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 60 cm above GL duly painted including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete The panel shall be comprising of the following:-(a)Phase indicator lamps,modular,LED type (R-Y-B)-03 Nos (b) LED Multifunction Meter Input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC Flush mounting 96 x 96 mm Site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Runhoursetc-01 No(c) MCCB 4 POLE 415 V 200 A (35 KA) ,4 pole with adjustable thermal setting-01 No.(I/C) (d) MCCB 4 POLE 415 V 100 A (35 KA) ,4 pole with adjustable thermal setting-04 No.(3 O/G+01 Spare) (e) MCB TPN 415 V 63 A-02 No alongwith Digital timer and 70Amp ML4 contactor for street light
14M&L for road cutting for laying cables in GI pipe and making good disturbed surface by using suitable ratio of PCC all as specified and directed.Note:- Laying of cables and GI pipe will be measured separately under respective items.
15S&F in replacement of GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers all as specified of 50 mm bore complete.
16Boring holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150mm dia suitiable for 0.4 mpa working pressure complete all as specified and directed.
17M&L for heat shrinkable indoor/ outdoor LT end terminations for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing
18S&F Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.and applying a priming coat of approved steel primer using structural steel etc. all as specified
19M&L preparing New Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying two Coats of Synthetic Enamel Paint (First quality) over a coat of red oxide primer complete all as specified and as directed.
20Providing and fixing rectangular high density polyethylene water storage loft tank with cover of capecity 5000 Ltr, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.
21Providing and fixing 20mm dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
22Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour. 20mm nominal bore. Weighing not less than 62 gms.
23Providing and fixing PTMT stop cock of approved quality and colour 20mm nominal bore, 89 mm long. Weighing not less than 88 gms.
24M&L Pre-cast cement concrete block masonry Type C1 1:3:6 (20mm graded stone aggregate) with solid blocks, exc. 10 cm in width and setting in cement mortar (1:4),complete all as specified.
25M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement.
26S&F 20mm Dia Ball brass valves,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed
27S&F 20mm Dia Gate Ball CPVC valves,high pressure Fixed complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57785995
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29.35 Lakhs
LAST DATE 19-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Standby Power Supply To 607 Gd Flt Alongwith 5000 Ltr Water Tank With Iron Stand In Bcr Section At Af Stn Bhuj
Basic Detail
Tender No 8647/V/E8
Bidding Type Tender
Location
City Kachchh
State Gujarat
Key Dates
Publish Date 30 Sep 2026
Submission Date 19 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 29.35 Lakhs
Tender Fee 500
EMD 58700
Exemption Available
Document List
859351e2-411a-45da-81dc-c4a8159cda71.html
8647PS.pdf
BOQ_887698.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

859351e2-411a-45da-81dc-c4a8159cda71.html

pdf

8647PS.pdf

xls

BOQ_887698.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders