Tender For Special Repair To Roof Treatment Of School Bldg At Kv No 2 At Af Stn Pune And Provision Of Iron Door And Tiles For Cupboard Storage Of Dry Ration At Airmen Mess 9Brd Af Stn Pune Under Ge (Af) Lohegaon
Tender Value
49 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
18 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Roof Treatment Of School Bldg At Kv No 2 At Af Stn Pune And Provision Of Iron Door And Tiles For Cupboard Storage Of Dry Ration At Airmen Mess 9Brd Af Stn Pune Under Ge (Af) Lohegaon
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old existing water proofing treament from the top of RCC/arch slab, including demolition of existing PCC padding, plaster, brick bat coba (upto the thicknes of 15cm) and hacking the top of RCC slab, cleaning with water and disposal of rubbish off the premises. Complete all as specified and directed. |
| 2 | Demolition of cement concrete of any description and in any position not otherwise specifically provided for |
| 3 | M&L cement concrete type B1-1 1:2:4 (using 20mm graded aggregate) as in roof padding, roof/chajjas kerbs or mud stops, rounded or chamfered on edges, haunching etc. finished even and smooth without using extra cement with water proofing compound. Note- WPC shall be paid separately. |
| 4 | Supply only liquid water proofing compound. |
| 5 | Supplying and laying composite 1.2 mm thick, HOME SHIELD TPO RF BG (S) Membrane is a high performance, heat wieldable, single side fleece backed thermoplastic polyolefin (TPO) sheet, manufactured and supplied in thickness of 1.2mm with overlap joint of 75 mm designed for waterproofing and heat shielding roofs of new and existing buildings. The TPO sealed properly with hot air welding machine & terminate TPO at the top of parapet wall with termination stip and fix it by screw at 300 mm C/C and sealed with HS joint seal PU on top including surface preparation like remove all those gravels, dirt, oil and other foreign particles by jet or dry air and clean the surface mechanically or by grinding to make it smooth before application. The membrane is designed for adhesion to screed, PCC, RCC, cementitious and other adhesives for easy application over flat roofs. HS TPO membranes are designed with high solar reflective index, thermal emittance, and solar reflectance, enabling the membrane to provide insulation with high surface albedo. Elongation at Break 60 Min 80 Typical as per ASTM D 751 Tearing Strength 25 Min 30 Typical as per ASTM D 751. Puncture Resistance 57 as per ASTM D751 Solar Reflectance Index 100 Weather Resistance > 21,600 as per ASTM G155. Termination of Membrane: The membrane needs to be terminated at the top of the parapet wall using aluminium strip, non-corrosive screw for anchoring with hybrid PU sealant. Expansion Joint Treatment: HS Joint Seal PU Sealant GG is single component Polyurethane elastomeric sealant. HS Joint Seal PU Sealant GG resists crack arising out of movements of joint materials. It conforms to EN 14187-S 2003, BS 5212, ASTM C-920, ISO-11600. Use polyethylene closed cell foam rod or sheet or equivalent in expansion, construction & control joints as back up material to avoid 3-face adhesion and to avoid contact between joint forming board & sealant Apply HS Joint seal PU Sealant GG from the gun slowly to avoid any air entrapment. Smooth out with soapy water by pressing the mastic against the edges and the joint while taking care not to create air bubbles. Remove protection strip. For old concrete joints where repair of joints are required, HS Elastoprime is to be used as priming material before sealant application. Elongation at break, % as per ASTM > 400. Hardness, Shore A as per ASTM D 2240 30 ± 2Elastic recovery, % as per ASTM D926 ≥ 70 Modulus of elasticity at 100 %, MPa 0.40 as per ASTM D 412 Movement Compatibility, ± 30 % (MAF)As per ASTM C 719 Solid content, > 90% Cure time @ 23 OC and 50% HR > 2 mm / 24 hrs UV resistance is good. Consumption (Approx) Joint Width is 25 mm Joint Depth is 12 mm Theoretical Coverage / 600 ml is 2 mtr. Protection Application: Thereafter, providing & Installing aluminium sheet flashing protection layer 20 gauge & 250mm wide sheet fixed on one side of the joint & free to move the other side of the joint. (For Width of up to 75 mm).” |
| 6 | Supply and Application of 3 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then top-coating with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to BIS STD IS 17218:2019 with Pull off Adhesion 2.8 Mpa, passes 2500 hrs accelerated durability test and other tests as specified, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 120 +/- 20 microns using brush, roller, airless spray gun as applicable. |
| 7 | S&F 1500 litres rotational mouded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I incl 20 mm bore ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed and incl dismantling of water capacity 1500 litres and Complete all as specified and directed. |
| 8 | S&F 1000 litres rotational mouded polyethylene three layer water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I incl 20 mm bore ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed and incl dismantling of water capacity 1000 litres and .Complete all as specified and directed. |
| 9 | S & F 25 mm dia GI tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors and incl taking up or down 25mm bore of pipe steel tubing and connections, including cleaning for re-fixing or removal to store and . Complete all as specified and directed. |
| 10 | S & F 40 mm dia GI tubing medium grade with all fittings and fixed to walls and ceiling or laid in floors. and incl taking up or down 40 mm to 50mm bore of pipe steel tubing and connections, including cleaning for re-fixing or removal to store and Complete all as specified and directed. |
| 11 | M&L 100mm thick cement concrete type B-1 1:2:4 (using 20mm graded aggregate) as in platform of water storage tank incl necessary formwork. |
| 12 | Demolition of cement concrete roof facia/chajja (unreinforced) of any description and in any position not otherwise specifically provided for. |
| 13 | M&L RCC (nominal mix) type B-1, 1:2:4 (using 20mm graded aggregate) as in chajjas, roof facia and height of bldg upto 8 m and incl necessary scaffolding. Complete all as specified and directed. |
| 14 | Formwork to chullah hoods, chajjas, troughs and similar items including edges flat rough finished surface of concrete. |
| 15 | M&L for preparation for old concrete surfaces for drilling extra bars suitable for 10mm dia deformed TMT bar upto specified depth including filling with epoxy resin and TMT bar for chajja repair etc Complete all as specified and directed. |
| 16 | Supply only applying nitto bond chemical as per manufacture instruction over demolished surface of old concrete surface complete all as specified and directed. |
| 17 | S&F GI wire netting 0.91 mm dia and 20 mm mesh lathing to wood or metal studding, joists etc in ceiling, stanchions, beams etc including all laps, cutting and waste complete all as specified and as directed. |
| 18 | S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ens and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing clips. |
| 19 | Taking down cement or cement lime plaster any description on brick or stone walls, etc including raking out joints, hacking for key scrubbing down with water etc. Complete all as specified and directed. |
| 20 | M&L 12mm thick ready mixed cement plaster in CM 1:3 on wall, chajjas surface (top, bottom and sides), roof facia, hanging facia portion etc upto 6m to 8m height and incl scaffolding. |
| 21 | M&L for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces upto 6m to 8m height incl scaffolding. |
| 22 | Removing building materials etc. (other than spoil payable under items 03028 to 03031 in Section-3—Earthwork) to a distance of upto 1km from total distance, beyond the lead included in the rates, including loading, unloading and stacking at the destination |
| 23 | Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings |
| 24 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 25 | S&F Fe 410-W (Gde E- 250) quality A Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. |
| 26 | M&L applying two coats of synthetic enamel paint on steel & iron surfaces of any description, not otherwise, described, over 10cm width or girth including preparation of new surface & applying one coat of red oxide, zinc chrome |
| 27 | Demolition of Brickwork or stone/boulder masonry/PCC block masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 28 | M&L for pre-cast cement concrete block masonry Type C-I 1:3:6 (20 mm graded aggregate) with solid block ,exc 10cm in width and set in cement mortar 1:6 complete. |
| 29 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm in floors {Superior/Premium quality}, set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15 mm thick screed bed in CM (1: 4) complete all specified and directed. |
| 30 | M&L for Brickwork with fly ash bricks straight or curved on plan exc 6 m mean radius in CM 1:6 complete. |
| 31 | M&L for stone slabs in sun-shades, chajjas, shelves, cills, landings, cover stones, templates, etc. n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4. complete all as specified and directed. |
| 32 | M&L for 10 mm thick in CM 1:6 rendering on brick or concrete surfaces finished even and smooth without using extra cement on wall complete all as specified and directed. |
| 33 | M & L for prepartion of newly plastered surfaces on walls and priming plastered surfaces with alkali resistant primer and applying two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50gms/litre, of approved manufacturer over 3 mm wall care putty in 3 layers of 1 mm each, of required shade and colour complete, as per manufacturer's specification complete all as specified and directed. |
| 34 | Labour only for full round moulding to 18 to 20mm thick granite slab all as directed by Engineer-in-Charge. |
| 35 | M&L granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platform and vertical surfaces and like in CM (1:4) incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade complete all as specified and directed. |
| 36 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to beprepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 37 | M&L for mild steel plates for covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughsand funnels, etc. cut tosize edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 30, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender