Housing Urban and Rular Development Local Bodies Closing in 6 days TDR #57785923

Tender For Modernization/Upgradation Of Existing Parks/Green Belts.Sub-Head:- Supply, Installation And Testing Commissioning Of 10 Mtr Octagonal Gi Pole/ 4 Mtr. Gi Poles Along With Led Lights Of Suitable Wattage And Other Accessories Including Panel

Issued by Local Bodies · Delhi, Delhi
Tender Value
34.19 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
6 days left
EMD
68392
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sub-Head:- Supply, Installation And Testing Commissioning Of 10 Mtr Octagonal Gi Pole/ 4 Mtr. Gi Poles Along With Led Lights Of Suitable Wattage And Other Accessories Including Panel Etc. At Multigym Park Park Sec-3 And Remal Wala Park Sector 3 Rohini, Under Horticulture Division-5.

BOQ

Name of Work:- Modernization/upgradation of existing parks/green belts.Sub-Head:- Supply, installation and testing commissioning of 10 mtr octagonal GI pole/ 4 mtr. GI poles along with LED lights of suitable wattage and other accessories including panel etc. at Multigym park park sec-3 and Remal wala park sector 3 Rohini, under Hort. Division-5.
Sl. No. Item Description
1Supplying, Fabrication and Installation of 4 mtr. high Pole made out of 65 mm dia. NB, B-class GI Pipe ISI marked duly welded with MS Base Plate of size 300 mm x 300 mm x 12 mm thick with stiffener of size 130 mm x 60 mm x 5 mm thick; top edge to be blunted (No sharp edge), suitable Earth Stud on Base Plate, making suitable size hole in pole at a height of 2.5 meter from base plate for cable entry/exit, painting & numbering of pole, making suitable size hole in base plate for cable entry/exit into the pole and fixing the pole on the existing foundation with the existing nuts-bolts, washers etc. complete as required.
2Supplying and Fixing of Single Over Hang (SOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long MS Tube of suitable diameter for Light Fitting accommodation, connection etc. complete as required.
3Supplying and Fixing of Double Over Hang (DOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long MS Tube of suitable diameter for Light Fitting accommodation (Angle as per EIC/AE direction).
4Supplying and Fixing of Ring type Bracket made of MS Pipe of diameter 48 mm, ring diameter 600 mm & suitable for mounting on 65 mm diameter MS/GI Pole with four nos. of spokes connecting the central mounting portion to ring, suitable for Light Fitting accommodation i/c connection etc. complete as required.
5Supplying, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt
6Supplying,Replacement, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).45 Watt
7LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, Replacement, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg, suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).70 watt
8Supplying, installation, testing and commissioning of 45 watt post top latern (for gate light), with aluminium canopy i/c supply and fixing of suitable mounting accessories ( Like Bracket/Nut bolts etc.) & suitable size wiremesh complete as required.
9Supply and Installation of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia. GI Pole with the following Provisions/Accessories Mounting in Box etc. complete as required.a) 2 Nos. Clamps made out of 19 mm x 3 mm MS Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm.g) Neutral Link- 1 No.
10Providing and Laying in Position, 1:2:4 (1 Cement : 2 Coarse sand : 4 Graded Stone Aggregate) Reinforced Cement Concrete Foundation of size 450 mm x 450 mm x 1200 mm deep (900 mm below Ground Level and 300 mm above Ground Level) including excavation of earth, refilling, providing, cutting, bending and placing in position, Reinforcement of Cold Twisted Bars of 12 mm dia.- 1200 mm long (approx.)- 8 Nos. and Reinforcement Ring of Cold Twisted Bar of 8 mm dia.- 1400 mm long (approx.)- 6 Nos. (with suitable spacing) including centering & shuttering as required with Providing, Fixing and Positioning of One Set of Foundation Bolts comprising of 4 Nos., 16 mm dia. 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 Nos. GI nuts and 2 Nos. GI washers etc. per bolt and 1 No. anchor plate (3 mm thick) of suitable size and providing 63 mm (OD) DWC pipe ISI marked for cable entry & exit and foundation should be finished with neat cement punning technique on the exposed portion of foundation complete as required.
11Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm
124C x 25 sq. mm
13Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
14Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a)63 mm dia. (OD-63 mm & ID-51 mm nominal)
15Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.Up to 35 sq. mm
16Supplying and drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the existing surface/recess steel/PVC conduit as required.3C x 1.5 sq.mm
17Supplying,Replacement, installation, testing and commissioning of floor mounted LT feeder pillar cubical type double door of size 1000 mm x 900mm x 300 mm deep duly compartmentalized and with general arrangement made out of 2mm thick CRCA sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls,duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles,ferrules wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-charge) . (a)100 Amps.30KA Four Pole MCB ('C'-Series), ----1 No.(b)16 Amps. SP MCB ('C'-Series), 10 kA------ 6Nos(c)6A-32 A DP MCB ('C'-Series),10KA ------1No.(d) Analogue Timer switch for daily operation and toggle switch for auto/manual --1 No. (e) 32 Amps. AC-3, 3 pole power contactor -----1 No. (f) 30 Ampere 4 way neutral link/connector ------2 Nos. (g) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No (h) Ammeter (0-30 A) 96mm X 96mm square type----1 no.(i) Phase Indicating Lamp Set with fuses ----1 Set (j) Danger notice plate -----1 No (k) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set. .(l) Lifting hook on the top of panel board and lighting arrangement inside the feeder pillar---- 1 No.
18Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .(a) 125 Amps. 4 pole MCCB, 36 K Amp.--1No. (b) 3 phase DOL submersible pump starter with relay range of 9 to 14 Amp. --- 1 Set. () 63 Amp MCB , C- Curve ----1 no. (c) 32 Amps. DP MCB ('C'-Series)------2No. (d) 32A TP & N MCB (C-series)----2 No. (e)Single phase preventor & dry run protection relay + VI meter (f) Danger notice plate -----1 No (g) Lifting hook on the top of feeder pillar ---1Set. (h) AI. Bus Bar 150 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set.(i) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.(j) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.(k) Phase Indicating Lamp Set with fuses ----1 Set
19Supplying, Fabrication and Installation of Wire Mesh Protection Frame for Existing Feeder Pillar, constructed from 8 SWG MS wire mesh with a Nominal size of 75 mm x 25 mm Rectangle. The Frame dimensions are 1.5 mtr. (Width) x 1.00 mtr. (Depth) x 2.00 mtr. (Height). It includes a Base Frame made of 40 mm x 40 mm x 6 mm MS Angle Iron, MS Strip Supports of 40 mm x 6 mm, and 0.5-meter-long leg supports of the same Angle Iron, all as per the approved drawing. Additionally, provide a suitably sized door, Supply and Fix a godown lock with locking arrangement, painting, and grouting with 1:2:4 Cement Concrete Foundation, as approved by the Engineer-in-Charge, complete as required.
20Repairing of existing feeder pillar i/c replacment of 2 mm CRCA sheet in front / side door with welding of hinges, gasketted cover, handle, locking arrangement painting with both sides etc as reqd.
21Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
22Providing& laying of DWC HDPE pipe of size 63 mm outer dia, by trenchless technology with no dig method by making bore hole in horizontal direction across the road/path with boring equipment i/c jointing / cleaning of pipes, excavation of pits of required size & depth etc. complete as required.
23Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required.
24Providing and fixing of monobloc pump cover made up of 3 mm MS sheet of size 1000 mm (L) x 800 mm (W) x 600 mm (H) and rain protection covers 100 mm with Suitable provision for fixing inlet and oultet GI pipe of dia. upto 65 mm with double door and proper locking arrangement, supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 0.5 mtr. long grouted with 1:3:6 CC foundation and should be 0.2 mtr. above ground level. Legs should be covered with brick walls,duly 1:4 cement plaster i/c paiting with 2 coats of red oxide metal primer and polyurethane-based anti-rust enamel paint complete as required.
25Supplying, Erection and Commissioning of HOT Dip galvanized octagonal steel pole of 10 mtr height made out of 3 mm thick sheet having bottom 210 mm A/F & top 90 mm A/F with built in connector control box with flush cover on height of 1500 mm from the bottom of pole, with base plate of size 320 mm x 320 mm x 20 mm thick with 250 mm wide 3mm thick hot dip galvanised ms strip of suitable size in octagonal shape welded permanenty around on window cover/junction box , the pole is to be fixed on existing RCC foundation with bolt and nuts making connection, interconnection with thimble/ lugs in the connector box,Earth terminal suitable for 6 SWG GI wire / 2.5 sq. mm wire welded , earthing, making/ numbering of pole etc as required with following accessories with mounted in built in control box.a) 6 mm thick laminated sheet along with 2 nos. 32 Amp, 10KA, SPMCB, 'C' charcteristic on the dinchannel, 2 no. 63 Amp terminal block suitable for 25 sq.mm Aluminum condr. cable and din channelfor MCB's.b) Earth stud weld at suitable height i/c washer, spring washers and nuts.c) Cable support clamps suitable for 2 nos. of 2x 10 sqmm Cable.d) Supply of all other fixing accesories as required. ( Drawing of pole shall be approved from the engineer incharge).
26Providing and laying in position M 20 (1:2:4) reinforced cement concrete foundation of size 500 mm long x 500 mm wide and 1600 mm deep i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia 1650mm long (approx.) -8 Nos. and reinforcement ring of cold twisted bar of 8 mm dia 1800 mm long (approx.)-10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-24 x 750 mm long (150 mm top threaded portion) GI foundation bolt (EN- 8 grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/ Anchor plate of size 320 mm x 320 mm x 4 mm thick having 4 Nos. 26 mm dia holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos DWC pipe for cable entry and exit as required. (Drawing to be approved by Engineer in charge.)
27Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 250 Watt
28Supplying and Fixing of hot dip galvanised Bracket made out of B class MS pipe of 48 mm diameter of suitable length/size for fixing following numbers of 250 W flood lights, including providing a 400 mm long canopy of suitable diameter for fixing on 90 mm OAF octagonal pole, including providing and fixing all necessary clamps, nuts, bolts, supports, accessories and other required materials, complete as required(drawing of Bracket approved by the Engineer-in-Charge).For fixing of 2 Nos 250 watt flood light
29For fixing of 3 Nos 250 watt flood light
30For fixing of 4 nos. /or upto 8 Nos. 250 watt flood light
31Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57785923
AUTHORITY Local Bodies
TENDER VALUE 34.19 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sub-Head:- Supply, Installation And Testing Commissioning Of 10 Mtr Octagonal Gi Pole/ 4 Mtr. Gi Poles Along With Led Lights Of Suitable Wattage And Other Accessories Including Panel Etc. At Multigym Park Park Sec-3 And Remal Wala Park Sector 3 Rohini, Under Horticulture Division-5.
Basic Detail
Tender No 46/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 30 Sep 2026
Submission Date 06 Oct 2026
Open Date 07 Oct 2026
Finance
Tender Value 34.19 Lakhs
Tender Fee Ref. Documents
EMD 68392
Exemption Available
Document List
35d69b0c-bb0b-4af8-aa1d-09b749d74d58.html
BOQ_975533.xls
NIT46.pdf
PressNoticeNIT46.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

35d69b0c-bb0b-4af8-aa1d-09b749d74d58.html

xls

BOQ_975533.xls

pdf

NIT46.pdf

pdf

PressNoticeNIT46.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders