Tender For Provn Of 125 Kva Dg Set With Amf Panel And Connected Items At 652 Coy Asc (Civ Gt) Imtrat Under Ge(Af) Hasimara
Tender Value
19 Lakhs
Estimated cost
Bid Submission
23 Oct 2026
22 days left
EMD
38000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalpaiguri → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of 125 Kva Dg Set With Amf Panel And Connected Items At 652 Coy Asc (Civ Gt) Imtrat Under Ge(Af) Hasimara
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : PROVN OF 125 KVA DG SET WITH AMF PANEL AND CONNECTED ITEMS AT 652 COY ASC (CIV GT) IMTRAT UNDER GE(AF) HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Supply installation testing and commissioning of silent Diesel Engine driven generating set 415 volts, 125 KVA / 100 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG Set, with CPCB -IV+ type latest approved and, self excited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Hasimara including testing carried out by the contractor in presence of IEM, Engr-in-Charge & rate included of DG Set testing is deemed in quoted rate including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following :-Alternator - Standard design alternator, Power Rating 125KVA/ 100 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8(lagging) Current 203 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Water cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722. Make of the Alternator : Diesel Engine : Minimum 206 BHP capacity, multi stroke, 6 Cylinder, TurboCharged Diesel Engine suitable for 125KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under :-Insulation class - 'H', Temperature rise class - 'H', Excitation- Self excited Regulation performance - The voltage is kept constant with +/- 1%, manual voltage adjustment with in +/- 5%, Frequency Regulation +/- 1% suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel shall deemed to be include in quoted rate.(i) Flywheel with housing(ii) Cooling System : Mounted radiator with fan and belts(iii) Cooling Water Pump : Centrifugal type belt driven |
| 3 | (iv) Exhaust System : As per OEM recommendation/specification. (Exhaust system high should be building hight + 03 mtr) duly wrapped with aluminium cladding for MS Exhaust Pipe (v) Starting System :- Electric Self Starter with maintenance free batteries including battery charging alternative belt driven.(vi) Batteries :- 24 Volts DC electrical batteries of suitable AH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed.(vii) Fuel tank of adequate capacity:- As per OEM norms and specifications designed in built tank for above capacity of DG Set.AM Panel: Auto Main Failure (AMF) Panel made out 14/16 Gauge CRCA sheet weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 125 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable trom Gen Set to AMP Panel. Contactor of Suitable capacity 3 pole with required nos as per OEM, TP contactor for netural for both supplies, suitable capacity of MCCB, 4 Pole for both supplies CTs 150/5A for both the supplies, Push buttons, Indication Lamps, 2 over load + earth leakage relay, Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 24 V, with trickle and boost charging, ON/OFF Switch, Automatic/Manual Switch, Hooter, Voltage sensing relay.Six window anunciator for fault indications.(i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. sound ratio less than 7Db Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder/epoxy to be provided for better weather resistance.(v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic/weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used. (xiv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform.(xv) The DG set should be provided with external emergency stop push button.(xvi) Provn of 2 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled. (xvii) Fuel gauge to be provided with the neck of fuel tank.(xviii) Tools as per manufacturers with the box. Making of foundation for placement of DG Set as per site requirement and including provision of anti-vibration pads shall deemed to be included in quoted rate. Note :- 1.All outgoint feeders shall be connected by cable through suitable size gland palte/glands. 2. DHPPN required for testing deemed to included in unit Quoted rate. |
| 4 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, for shafts, wells cesspits, manholes, foundation of pole/stayetc. and n.exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 5 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 6 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil, complete all as specified and directed. |
| 7 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 120mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 8 | Supply, laying and testing XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross sectional area 120 Sqmm 3.5 core laid in trenches, complete all as specified and directed.Note : Earth work shall be measured and paid seperately. |
| 9 | M &L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6.0cm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part -1, including necessary excavation and earth work, P.C.C (1:3:6) type C-1 with 50mm thick Pre-cast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8mm dia deformed bar 10cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15cm compacted thickness all around the earth electrode, with funnel and 20mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, Gl earth wire protected by 40mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion including dismantling of old unserviceable earthing of any descriprtion, complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysOct 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 29 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender