Tender For Repair/ Maintenance To Day To Day Complaints Of Distribution Pipe Lines Incl Allied Works At Ph-I And Ph-Ii Area Under Ge Narangi.
Tender Value
80 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
25 days left
EMD
1.45 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance To Day To Day Complaints Of Distribution Pipe Lines Incl Allied Works At Ph-I And Ph-Ii Area Under Ge Narangi.
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or water supply pipes lines etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 2 | Excavating in trenches not exceeding 1.5 m wide and exceeding 1.5 m but not exceeding 3.0 in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and exceeding 1.5 m but not exceeding 3 m in depth and getting out in soft/ loose soil complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed. |
| 4 | Removing excavated material not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 5 | Excavation in trenches acros metal road by cutting raod / by digging trench less tunnel for passing pipe of any size and making good the road as it was by proper PCC and applying two coats of blak paint to match the surface as it was complete all as specified and directed (The job included excavation/ trenchless tunneling and making good properly complete) |
| 6 | Taking up cast iron water mains (including all fittings), 100 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 7 | Taking up cast iron water mains (including all fittings), 150 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 8 | Taking up cast iron water mains (including all fittings), 200 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 9 | Taking up cast iron water mains (including all fittings), 250 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 10 | Taking up cast iron water mains (including all fittings), 300 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 11 | Taking up cast iron water mains (including all fittings), 350 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 12 | Taking up cast iron water mains (including all fittings), 450 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed. |
| 13 | Relaying of the 100mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 14 | Relaying of the 150mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 15 | Relaying of the 200mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 16 | Relaying of the 250mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 17 | Relaying of the 300mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 18 | Relaying of the 350mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 19 | Relaying of the 400mm bore size CI/DI water mains after thoroughly cleaning, with new fittings fixed to wall/ceiling/floor or laid in trenches including new tyton rubber gasket/ lead joints, CI/DI pipes and reducing to required length in position for insertion of new tees, branches, etc. before laying complete all as directed. Note : Excavation , earth work and DI fittings will be measured and paid seperately. |
| 20 | Supplying & laying in replacement of trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length, conforming to IS 8329-2000, outside shall be zinc coated with finishing layer of black bitumen/blue epoxy coating duly ISI marked,complete all as specified and as directed. |
| 21 | Supplying & laying in replacement of trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length, conforming to IS 8329-2000, outside shall be zinc coated with finishing layer of black bitumen/blue epoxy coating duly ISI marked, complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. |
| 22 | Supplying & laying in replacement of trenches 200 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length , conforming to IS 8329-2000, outside shall be zinc coated with finishing layer of black bitumen/blue epoxy coating duly ISI marked,complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. |
| 23 | Supplying & laying in replacement of trenches 300 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length , conforming to IS 8329-2000, outside shall be zinc coated with finishing layer of black bitumen/blue epoxy coating duly ISI marked, complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. |
| 24 | Supplying & laying in replacement of trenches 350 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length , conforming to IS 8329-2000, outside shall be zinc coated with finishing layer of black bitumen/blue epoxy coating duly ISI marked, complete all as specified and as directed. Note- Rubber gasket joints (push on joints) shall be measured and paid separately. |
| 25 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 80 mm complete all as specified and as directed. |
| 26 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 100 mm complete all as specified and as directed. |
| 27 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 150 mm complete all as specified and as directed. |
| 28 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 200 mm complete all as specified and as directed. |
| 29 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 250 mm complete all as specified and as directed. |
| 30 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 300 mm complete all as specified and as directed. |
| 31 | M&L for replacement of flanged joint with nuts, bolts, rubber or fibre board gasket for flanged cast iron pipes and fittings of nominal bore 450 mm complete all as specified and as directed. |
| 32 | Cutting the existing cast iron/ galvanised iron pipes 100 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. |
| 33 | Cutting the existing cast iron/ galvanised iron pipes 150 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. |
| 34 | Cutting the existing cast iron/ galvanised iron pipes 200 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. |
| 35 | Cutting the existing cast iron/ galvanised iron pipes 250 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. |
| 36 | Cutting the existing cast iron/ galvanised iron pipes 300 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed. |
| 37 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 450 mm complete all as specified and as directed. |
| 38 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 300 mm complete all as specified and as directed. |
| 39 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 250 mm complete all as specified and as directed. |
| 40 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 200 mm complete all as specified and as directed. |
| 41 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 150 mm complete all as specified and as directed. |
| 42 | M&L for replacement of run lead joint for spigot and socket cast iron pipes and fittings of nominal bore 100 mm complete all as specified and as directed. |
| 43 | Supply and laying cast iron fittings for flanged pipes such as bends (any type radius and angle), tapers any type (straight, bends, increasing, decreasing or double socket etc.), tee pieces, single branch, 'Y' junction, double branch, straight connecting pieces etc. but all ends flanged suitable for bore of pipe upto 150 mm complete all as specified and as directed. |
| 44 | Supply and laying cast iron fittings for flanged pipes such as bends (any type radius and angle), tapers any type (straight, bends, increasing, decreasing or double socket etc.), tee pieces, single branch, 'Y' junction, double branch, straight connecting pieces etc. but all ends flanged suitable for bore of pipe from 200 mm to 300 mm complete all as specified and as directed. |
| 45 | M&L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed. |
| 46 | Material and labour MS studs nuts and bolts of any size and any length with suitable Mild Steel washer of any size for jointing of flange pipes/valve gland etc. complete all as specified and as directed. |
| 47 | Taking up or down 100 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 48 | Taking up or down 80 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 49 | Taking up or down 40 mm or 50 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 50 | Taking up or down steel tubing and connections, bore of pipes 25 mm and removing away from site, complete all as specified and as directed. |
| 51 | Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 52 | Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified. |
| 53 | Refixing 100 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 54 | Refixing 80 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 55 | Refixing 40 mm or 50 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 56 | Refixing 25 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 57 | Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 58 | Refixing 15 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed. |
| 59 | Supplying & laying in replacement of trenches 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 including taking down old complete all as specified and as directed. |
| 60 | Supplying & laying in replacement of trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 61 | Supplying & laying in replacement of trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 including taking down old pipe complete all as specified and as directed. |
| 62 | Supplying & laying in replacement of trenches 40 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 63 | Supplying & laying in replacement of trenches 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 including taking down old pipe complete all as specified and as directed. |
| 64 | Supplying & laying in replacement of trenches 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 65 | Supplying & laying in replacement of trenches 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 66 | Supplying & fixing to replacement of walls and ceilings or laid in floors 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 67 | Supplying & fixing to replacement of walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 68 | Supplying & fixing to replacement of walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed. |
| 69 | M&L for replacement of 3- layer PP-R (Polypropylene random copolymer) pipes 32 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 70 | M&L for replacement of 3- layer PP-R (Polypropylene random copolymer) pipes 25 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 71 | M&L for replacement of 3- layer PP-R (Polypropylene random copolymer) pipes 63 mm dia outer dia ,SDR 7.4 (PN-16) pipes UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including fittings PP-R plain & brass threaded type polypropylene random fixed complete to walls, ceilings or in floors etc. complete all as specified and directed. |
| 72 | Supply and fixing in repair to CI Detachable D joints of CI/DI/GI pipe of size 300 mm including rubber rings, nuts n bolts complete all as specified and directed (Note: Excavation to be measured and paid under relavent item of this schedule) |
| 73 | Supply and fixing in repair to CI Detachable D joints of CI/DI/GI pipe of size 250 mm including rubber rings, nuts n bolts complete all as specified and directed (Note: Excavation to be measured and paid under relavent item of this schedule) |
| 74 | Supply and fixing in repair to CI Detachable D joints of CI/DI/GI pipe of size 200 mm including rubber rings, nuts n bolts complete all as specified and directed (Note: Excavation to be measured and paid under relavent item of this schedule) |
| 75 | Supply and fixing in repair to CI Detachable D joints of CI/DI/GI pipe of size 150 mm including rubber rings, nuts n bolts complete all as specified and directed. (Note: Excavation to be measured and paid under relavent item of this schedule) |
| 76 | Supply and fixing in repair to CI Detachable D joints of CI/DI/GI pipe of size 500 mm including rubber rings, nuts n bolts complete all as specified and directed (Note: Excavation to be measured and paid under relavent item of this schedule) |
| 77 | S&F in repair rotational moulded polyethylene water storage tank 1000 litre capacity of triple layered layer wall construction (Cylindrical, vertical with closed top) hoisted and fixed in position including 20 mm dia ball brass valves, high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule all as specified and as directed. |
| 78 | Supply and lay MS ERW Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 450 mm, 8mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. |
| 79 | Supply and lay MS ERW Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 300 mm, 8mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. |
| 80 | Supply and lay MS ERW Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 250 mm, 8mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. |
| 81 | Supply and lay MS ERW Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 200 mm, 8mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. |
| 82 | Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 150 mm, 5mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. |
| 83 | Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100 mm, 5mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. Please Enable Macros to View BoQ information |
| 84 | Supply and lay MS Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 100 mm, 5mm thick duly painted by two coats of synthetic enamel of desired tint over a coat of red primer complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender