Tender For Development Of Border Tourism At Shri Tanot Complex Jaislamer Sector, Rajasthan Under The Assistance To Central Agencies For Tourism Infrastructure Development Scheme Construction of Entrance Gate With Cabin, External Development, Substati

Issued by Government Departments · Jaisalmer, Rajasthan
Tender Value
1.63 Crore
Estimated cost
Bid Submission
12 Oct 2026
8 days left
EMD
3.27 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Border Tourism At Shri Tanot Complex Jaislamer Sector, Rajasthan Under The Assistance To Central Agencies For Tourism Infrastructure Development Scheme Construction of Entrance Gate With Cabin, External Development, Substation Building, Hitheartre (Raj) (Sh: - Providing 11/0.415 Kv Sub-Stations, Ht & Lt Panels/ Cables And Shifting Of Dg Sets).

BOQ

Name of Work:- Development of Border Tourism at Shri Tanot Complex Jaislamer Sector, Rajasthan under the assistance to Central Agencies for Tourism Infrastructure Development Scheme (C/O Entrance Gate with Cabin, External Development, Substation Building, hitheartre (Raj) (SH: - Providing 11/0.415 KV Sub-Stations, HT & LT Panels/ Cables and shifting of DG sets).
Sl. No. Item Description
1Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 3 x 1.5 sq. mm.
2Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. a) 6 x 1.5 sq. mm.
3Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm.
4Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm.
5Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal).
6Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. b) 90 mm dia (OD-90 mm & ID-76 mm nominal).
7Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. c) 120 mm dia (OD-120 mm & ID-103 mm nominal).
8Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. d) 160 mm dia (OD-160 mm & ID-135 mm nominal).
9Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal).
10Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. b) 90 mm dia (OD-90 mm & ID-76 mm nominal).
11Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. c) 120 mm dia (OD-120 mm & ID-103 mm nominal).
12Supplying and laying of following size DWC HDPEpipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. d) 160 mm dia (OD-160 mm & ID-135 mm nominal).
13\\"Supplying and fixing of light class G.I. pipe of 100 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required.
14Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
15Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
16Earthing with Copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
17Providing and fixing 25 mm X 5 mm Copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
18Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
19Providing and fixing 25 mm X 5 mm Copper strip on surface or in recess for connections etc. as required.
20Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
21Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
22Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. a) 100 A,30KA,FPMCCB .
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. b) 125 A,30KA,FPMCCB .
24Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. c) 200 A,30KA,FPMCCB .
25Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. d) 250 A,30KA,FPMCCB .
26Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. e) 63 A,10KA,FPMCCB
27Desigining, Fabrication Supply/installation/testing and commissioning of compartmentalised type outdoor feeder piller, double door made out of 2.03 mm thick CRCA powdered coated sheet having 200 amps, 04 nos insulated aluminium bus bars and to accommodate following accessories, front & back openable door, R-Y-B LED indicators and P & F of internal connection with suitable size of copper wires, following accessories & angle iron frame of size 1000 mm x 400 mm with 600 mm long legs made out of 50 mm x 50 mm x 5 mm thick angle & grouting the same in suitable cement concrete foundation, arrangement for incoming & outgoing cables, cable termination, earthing, locking, interconnection etc. as required. (CPRI Approved builder). The feeder pillar should have Indicating lamp (LED type) 22.5 mm 230 volt AC Red, Yellow and blue make L&T/Havells/simens- 03 nos, CT Ratio (Amp) 100/05, accuracy class 1, burden 05 VA - make L&T/AE/Trinity -03 nos, Digital Multifunction meter (VAF + PF) make L&T Cat no. WC411011OOOO or equivalent in AE/Siemns- 01 No. .The design of the feeder pillar should get approved by Competent Technical authority before fabrication. .The feeder pillar should have following provision to acccomodate:-(a) First feeder pillar:- 250 Amp , 4 Pole MCCB-1 No as a incommer and , 63 Amp 4 pole MCCB -05 nos as outgoing) . The design of the feeder pillar should got approved from Competent Technical authority before fabrication. (The FP should be of approx size 1500x 1000 x 400 mm deep (area of Feeder pillar is taken in sq mm face area) Qnty- 01 No.(b) Second feeder pillar:- 200 Amp , 4 Pole MCCB-1 No as a incommer and , 63 Amp 4 pole MCCB -05 nos, as outgoing) . The design of the feeder pillar should got approved from Competent Technical authority before fabrication. (The FP should be of approx size 1500x 1000 x 400 mm deep (area of Feeder pillar is taken in sq mm face area) Qnty - 01 No.(c) Third feeder pillar:- 100 Amp , 4 Pole MCCB-1 No as a incommer and , 63 Amp 4 pole MCCB -05 nos, as outgoing) . The design of the feeder pillar should got approved from Competent Technical authority before fabrication. (The Fp should be of approx size 1500x 1000 x 400 mm deep (area of Feeder pillar is taken in sq mm face area) Qnty - 03 No.(d) Junction Box:- 125 Amp , 4 Pole MCCB-1 No as a incommer and , busbar, as outgoing) . The design of the feeder pillar should got approved from Competent Technical authority before fabrication. (The Fp should be of approx size 600x 500 x 400 mm deep (area of Feeder pillar is taken in sq mm face area) Qnty - 03 Nos.
28SITC of indoor/floor-mounted MAIN LT PANEL, fabricated from 2.0/1.6mm CRCA sheet steel enclosure with RAL-7035 powder coating, mounted on a 75x40 mm M.S. base channel, and fitted with an 800A Aluminium Bus Bar with color-coded heat shrinkable sleeves.The panel includes Incomer-1 (TRN) equipped with 1 No. 800A 4P EDO 50kA ACB (Microprocessor release, O/C, S/C & E/F), 1 No. Under Voltage Release (415V AC), 1 No. Digital Multifunction Meter (415V AC, 3-Phase 4-Wire, Class 1.0), 3 Nos. Metering CTs (1000/5A, Class 1, 15VA Epoxy Cast Resin), 3 Nos. Phase Indicating Lamps (Red, Yellow, Blue), 4 Nos. 6A SP MCB (10kA), and 3 Nos. C.T. Shorting Links.The Incomer-2 (DG) comprises 1 No. 400A 4P 36kA TM-based MCCB with Rotary Handle, 2 Nos. Spreader Links, 1 No. Digital Multifunction Meter (415V AC, Class 1.0), 3 Nos. Metering CTs (1000/5A, Class 1, 15VA), 3 Nos. Phase Indicating Lamps, 4 Nos. 6A SP MCBs, and 3 Nos. C.T. Shorting Links, alongside 1 No. 630A 4P Changeover SwitchOutgoing Feeders consist of 2 Nos. 200A 4P MCCB, 4 Nos. 125A 4P MCCB, 3 Nos. 100A 4P MCCB, 1 No. 63A 4P MCCB, 3 Nos. 250A 4P MCCB, and 1 No. 160A 4P MCCB (all 25kA TM-based with respective Rotary Handles and Spreader Links).The panel is complete with internal wiring, insulators, hardware, lugs, PVC channels, MCB channels, door locks, hinges, bidding, connectors, spiral wrapping, saddles, and packing materials. (Makes: Schneider / L&T / Hager / Socomec / Hindalco / TATA / Essar /ABB). As per latest BIS norms.Note: Ensure proper clearance and cable space. The detailed Single Line Diagram (SLD) and General Arrangement (GA) drawing of the panel must be got approved by the Competent Technical Authority before the commencement of fabrication.
29Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required. (i) 3 core 240 sqmm
30Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required. (i) 3 core 240 sqmm
31Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.
32Supplying and Laying of one number one number aluminium conductor, XLPE Insulated, PVC sheathed, armoured power cable of 33 KV HT grade of following size in the existing RCC/ HUME/ METAL pipe as required.. (ISI marked Make Havells /Polycab/Plaza /KEI /RR Kabel/ Grandlay)(i) 3 core 240sqmm.
33Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 2 Core X 16 sq.mm cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid in existing HDPE / RCC / Hume / Metal pipes/conduits, including necessary pulling, dressing, clamping, and end-to-end testing as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay).
34Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 2 Core x 16 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay).
35Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 4 Core x 16 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay).
36Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core X 35 sq.mm cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid in existing HDPE / RCC / Hume / Metal pipes/conduits, including necessary pulling, dressing, clamping, and end-to-end testing as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay).
37Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core x 35 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
38Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core X 50 sq.mm cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid in existing HDPE / RCC / Hume / Metal pipes/conduits, including necessary pulling, dressing, clamping, and end-to-end testing as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
39Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core x 50 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
40Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core X 70 sq.mm cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid in existing HDPE / RCC / Hume / Metal pipes/conduits, including necessary pulling, dressing, clamping, and end-to-end testing as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
41Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core x 70 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
42Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core X 95 sq.mm cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid in existing HDPE / RCC / Hume / Metal pipes/conduits, including necessary pulling, dressing, clamping, and end-to-end testing as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
43Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core x 95 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
44Supplying, Laying, Testing and Commissioning of 1.1 kV grade, 3.5 Core x 240 sq.mm power cable with stranded Aluminium conductor, XLPE insulated, PVC sheathed, galvanized steel strip/wire armored, conforming to IS: 7098 (Part-1) 1988. The cable shall be laid loosely/properly dressed in the existing masonry open duct, including necessary cleaning of duct, pulling, dressing, end-to-end testing and making necessary connections as required. (ISI Marked, Make: Havells / Polycab / Finolex / CCI / KEI / RR Kabel / Grandlay)
45Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm.
46Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. b) Above 35 sq. mm and upto 95 sq. mm.
47Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. c) Above 185 sq. mm and upto 400 sq. mm.
48SITC of 10 Watt, 240V, 3000K (Warm White) Outdoor LED Bollard Light fixture with IP65/IP66 ingress protection rating, having a minimum height of 800 mm, featuring a heavy-duty corrosion-resistant aluminium/extruded housing with a step-profile design on top for glare-free lateral (side) light distribution. The fixture shall include a high-efficiency integrated LED driver, impact-resistant diffuser, anchor bolts/base plate for floor mounting, internal wiring, making connections, testing, commissioning and providing a minimum of 01 (One) Year onsite comprehensive warranty from the date of successful commissioning as required. (Make: Orient Model: Step or equivalent approved make like Havells / CG / Philips / Surya / Syska / Bajaj)
49SITC of 05 Watt, 240V, 3000K (Warm White) Spike Light fixture with IP66 ingress protection rating, featuring a robust housing designed. The item shall include internal wiring, making connections, testing, commissioning and providing a minimum of 01 (One) Year onsite comprehensive warranty from the date of successful commissioning as required. (Make: Orient Model: LLSLPOP-05-W or equivalent approved make like Havells / CG / Philips / Surya / Syska / REO / Bajaj)
50Fabricating, SITC of pole mounted outdoor type single door control gear box of dust and vermin proof (CPRI approved) size not less than 500 mm(L) X 700 mm(H) X 150 mm deep made out of 2.0 mm (14 SWG) thick CRCA sheet duly powder coated having thickness of 80 micron (minimum) with hinged type single leaf door & pin type panel lock, suitable size 2.00 mm thick M.S. sheet inside the box as baseplate to accommodate all the accessories i.e driver, SPD, MCB, connector etc. for 4 Nos LED fitting (03 nos. existing & 01 no. for future extension) and having suitable size hole with gasket to seal entry of water from wire entry through the existing Pole/ nipple in pole, 1.6 mm thick perforated M.S. cover plate of 450 mm X 600 mm (minimum) size housed inside the box for covering SPD, Driver, MCB mounting on surface, knock out for MCB's, powder coated painting, fixing the box on pole by using 2 sets of 50 mm x 5 mm thick MS strip and U clamp with all necessary nut bolts, painting of clamp, earthing the body with 2 nos - 6 SWG GI wire from bus bar chamber to control gear box & door earthing with flexible green wire etc complete as required. (NOTE;- The control box of IP rating not less than IP54. This item shall include supply and installation of following accessories for execution of item no 1 & 3 to be accommodated in the control gear box with suitable size copper lugs/thimble, dressing all wires using PVC tags, screws etc. and necessary wiring by 2.5 sq mm copper wire for connection and interconnection etc. as required: i) Supplying and drawing 3X4 Sq. mm. FRLS PVC insulated Copper conductor cable from the existing bus bar chamber to MCBs installed in control gear box (as incomer). ii) Supplying and fixing 6 way 16 A brass neutral link with bakelite base in the box- 2 nos (as earth & neutral link). iii) Supplying and fixing 3 way 6 sq.mm- Polyamide tinned copper connector - 12 nos. iv) Supplying and fixing 04 nos. 10A/16A SP MCB, 01 no. 32A TPN MCB along with din bar suitable for mounting. v) Fixing of LED Driver- 3 nos. vi) Fixing of SPD - 3 nos. (SPD supplied under item no. 1) as required as per the direction of Engg-in-charge.\\"
51SITC of 03 Nos. of Non Integral LED Fitting with external driver and external SPD (Minimum 10 kV) of wattage 150 Watt each of CCT 3000- 6500 K, efficacy not less than 120 lumen/watt & total system lumen not less than 16500/each, outdoor type, IP66 rating, pressure die cast aluminum housing, PC/PMMA lens, efficient heat sink, driver, SPD, etc., suitable for operational input voltage range of 120-270 volt, with 2 years guarantee, conforming to relevant BIS and IES standards on existing 12 meter (approx.) high steel octagonal pole i/c providing new wiring inside the pole from the MCB of control gear box to the fitting on the top of the pole with 3 nos, 3 core 1.5 sq mm (3X1.5 Sq.mm) PVC insulated and PVC Round Sheathed, Multicore Copper Conductor flexible Cable i/c connections etc. complete as required. Total nos of LED should be minimum 60 nos in each luminary (or as per manufacturer design to meet required lumens). The external driver and external SPD shall be fixed in new control gear box which shall be paid separately under item no. 2. (One set shall consist of SITC of 3 nos. of luminaries with external driver, 3 nos SPD and 3 nos connecting cable from MCB to luminaries) i/c dismantling of existing fittings and all allied accessories etc. as required. Make: Orient / Havells / Bajaj / HPL / Philips / Polycab or its approved equivalent.
52Providing, fixing, testing and commissioning of decorative post-top LED outdoor luminaire with pole and installed at 6 Mtr pole, featuring a spun / die cast aluminium housing with integrated heat shink, UV stabilized clear/ opal optical grade polycarbonate diffuser, IP65, system efficacy >100 lm/W, 4 kV sugre protection, operating voltage240 V AC, 50 Hz, Power factor .0.95, THD < 10% Warm White CCT (3000K) and system power consumption of 70 Watt, complete with electronic driver ( 100-270 V AC) mounting on 6 pole / bracket top earting connection, testing and commissioning as per site requirements and engineer-in- charge instruction. Make :- Orient Electric- Tiara or its equivelent make like Bajaj/ Havells/ or ISI marked.
53Supplying and Erection of 6 Mtrs height hot dip G.I. octagonal pole on the cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling with following specifications - Bottom - 130 mm, Top - 70 mm , thick- 3 mm (bottom & top section) hot deep galvanise sheet , Base plate- 220 mm X 220 mm X 12 mm, foundation bolt size - 20 mm dia, bolt length - 600 mm, and - 04 Nos including supply and embedding 2 Nos. 40 mm dia medim class GI pipe for cable entry (from bottom of foundation to top of foundation for cable entry ), SMC (Sheet Moulding Compound) / FRP Looping Box / Junction Box size not less than (300x200 x 105 mm )to handle the incoming underground cable loop-in/loop-out and house the MCB or fuse, having locking arrangement etc. as required as per manufacturer specification.Make: Vipin S.T/ Crompton / Surya / Utkarsh / Bajaj / Jindal
54Supplying and Erection of 12 Mtrs height hot dip G.I. octagonal pole on the cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling with following specifications - Bottom - 210 mm, Top - 90 mm , thick- 3 mm (bottom & top section) hot deep galvanise sheet , Base plate- 310 mm X 310 mm X 16 mm, foundation bolt size - 24 mm dia, bolt length - 750 mm, and - 04 Nos including supply and embedding 2 Nos. 40 mm dia medim class GI pipe for cable entry (from bottom of foundation to top of foundation for cable entry ), SMC (Sheet Moulding Compound) / FRP Looping Box / Junction Box size not less than (300x200 x 105 mm )to handle the incoming underground cable loop-in/loop-out and house the MCB or fuse, having locking arrangement etc. as required as per manufacturer specification.Make: Vipin S.T/ Crompton / Surya / Utkarsh / Bajaj / Jindal
55S/I/T/C of Double arm bracket having cap made out of 80 mm dia GI pipe (Medium class),300 mm long and arm made out of 40 mm dia GI Pipe (Medium class) , 0.5 Mtr long one side and 0.5 Mtr another side to be welded with cap including fixing the bracket with 04 Nos GI nut on existing pole including connection testing etc as required as per direction of engg-in-charge.
56S/I/T/C of Ring Type Arm Bracket having cap made out of 80 mm dia GI pipe (Medium class),300 mm long and arm made out of Mild Steel, Hot Dip Galvanized, 3 mm thickness, 1 m length to be welded with cap including fixing the bracket with 04 Nos GI nut on existing pole including connection testing etc as required as per direction of engg-in-charge.
57S/I/T/C of straight arm bracket having cap made out of 80 mm dia GI pipe (Medium class),300 mm long and arm made out of 50 mm X 50 mm X 6 mm angle iron 1 Mtr long to be welded on cap including fixing the bracket with 04 Nos GI nut on existing pole including connection testing etc as required as per direction of engg-in-charge.
58SITC of 45 Watt, 240V, 5700K (Daylight) Outdoor LED Street Light fixture with IP65/66 ingress protection rating, featuring a heavy-duty aluminium pressure die-cast housing for optimal thermal management. The fixture shall be equipped with a high-impact UV-stabilized polycarbonate (PC) front cover and precision optical lenses designed for batwing light distribution. The item shall include an integrated high-efficiency electronic LED driver with a minimum of 4kV to 10kV surge protection, pole-mounting arrangement/brackets, internal wiring, making connections, testing, commissioning and providing a minimum of 01 (One) Year onsite comprehensive warranty from the date of successful commissioning as required. (Make: Orient Model: LSRAD-045-WC-PC or equivalent approved make like Havells / Bajaj / Wipro / HPL / Philips).
59SITC of 100 Watt, 240V, 5700K (Daylight) Outdoor LED Flood Light fixture with IP65/66 ingress protection rating, featuring a heavy-duty aluminium pressure die-cast housing for optimal thermal management. The fixture shall be equipped with a toughened glass in front and precision optical lenses designed for batwing light distribution. The item shall include an integrated high-efficiency electronic LED driver with a minimum of 4kV to 10kV surge protection, pole-mounting arrangement/brackets, internal wiring, making connections, testing, commissioning and providing a minimum of 01 (One) Year onsite comprehensive warranty from the date of successful commissioning as required. (Make: Orient Model: LFSMU-100-C-V1 or equivalent approved make like Havells / Bajaj / Wipro / HPL / Philips).
60Supply, installation, testing and commissioning of 500 Kva capacity (continuous loading) BEE 5 Star rated (Corresponding Level as per BIS amended upto date of receipt of tender) , 33/0.433 KV step down, 3 Phase, 50 Hz, Dyn 11 vector group, ONAN (Oil Natural Air Natural) copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade Cold Rolled Grain Oriented (CRGO) Core grade MOH or better, suitable for outdoor/indoor applications with On Load Tap Changer (OLTC) on HV side having AVR relay and Remote Tap Changer Control (RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to -15% in steps of 2.5%, having cable end boxes on HV side suitable for 3x400 sq.mm XLPE cable of 33 KV grade, including bus trucking arrangement on LV side including supplying and laying of copper conductor multicore control cable from transformer to HT breaker/panel for safety tripping, complete with all accessories and safety provisions as per relevant IS Code including first filling of filtered dehydrated oil, i/c supplying and grouting of suitable M.S. Channel with all accessories and transformer shall be confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 and as per CPWD specifications complete in all respects etc as required at site. The maximum flux density in any part of the core and yoke at rated voltage and frequency shall be such that the flux density with + 12.5 percent combined voltage and frequency variation from rated voltage and frequency does not exceed 1.9 Tesla. The permissible temperature-rise shall not exceed 40 0C for oil and 45 0C for above 200 KVA for winding. Inside of tank shall be painted with varnish or liquid resistant paint. For external surfaces one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall be referred to for paint thickness for normal to medium corrosive atmosphere. For highly polluted atmosphere and special application external paint work shall be as per direction of Engineer-in-Charge. Design ambient condition: a) air temperature 50 0C, b) Relative Humidity 90 % Max, c) Seismic Zone as per location of site, d) Altitude as per location/site. Noise level Shall not exceed limits as per NEMA TR-1 with all accessories running measured as per IEC 551 / NEMA standard. The transformer should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc. Marking Each transformer shall be provided with rating plate made of anodized aluminium/ stainless steel material securely fixed on the outer body, easily accessible, as per IS: 1180 Part-3. The entries on the rating plate shall be indelibly marked. Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Oil level gauge indicating oil level at minimum, 30°C and maximum operating temperature; c) Air release device (for non-sealed type transformers) d) Rating and terminal marking plates; e) Silica gel breather f) Drain-cum-sampling valve (¾″ nominal size thread, IS 554) preferably steel with plug for three phase transformers; g)Thermometer pocket with cap; h) Oil filling holes having (1¼″ nominal size thread) with cover (for sealed type transformers without conservator); i)Lifting lugs for the complete transformer as well as for core and winding assembly; j) Pressure relief device or explosion vent above 200 kVA; k) One filter valve on the upper side of the tank (for transformers above 200 kVA); l) Unidirectional flat rollers (for transformers above 200 kVA); m) Inspection hole (for transformers above 200 kVA); n) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); o) Arcing horns or suitable rating lightning arrestors for HT side – 3 Nos. p) Bird guard; q) Oil temperature indicator and winding temperature indicators for transformers above 200 kVA with suitable tripping mechanism above permissible limit r) Additional Neutral separately brought out on bushing for earthing. s) Non return valve (for conducting pressure test); t) Pressure relief device or explosion vent u).Monogram Plate v) Inspection cover w). Detachable type radiators with top and bottom shutoff valve. x) Oil Conservator with Oil level indicator, minimum level marking and drain plug for all transformers of capacity 50 KVA and above. y) Necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all transformers. As per latest BIS norms. Make Servokon/ Kirloskar Electric/ Electricfeild/ ABB/ HD Transformer/ T-Power transformer and switchgear ltd., Anmol make.
61SITC of 33KV HT VCB ICOG Panel as per SLD & BOQ with Aluminium Busbar, all complete The panel should by suitable for Indoor installation with IP-4X Rating. Construction shound be Form-4. The Design of the Panel should be Type Tested for 31,5 KA, 3 Sec Fault Level & internal arc 31.5 KA for 1sec. A. Sequence of Operation should be controlled by High Reliablity PLC with both Auto & Manual Mode. Design should incorporate hard wire fail safe measures to ensure non paralleling of the Incommers.Incoming & Outgoing: 11. 1: 800 A 3P EDO VCB2. Numerical Feeder Protection Relay with 4: Class 5 P10 Ct with 50, 51, 50N, 51N, 59, 27, 95.3. 3: Line PT for metering & protection4. 1: Master Trip Relay5. 3:50-100/5A, Class 1 CT, 10 VA6. 3 Phase Digital Voltmeter & Ammeter7. 1 Set: RY B Indication On - Off - Trip Indication.8. 1 Set. Spring Charge, Trip Circuit Healthy, Aux Supply Available Indication.9. TNC Switch & Emergency Trip Push Button10. Auto Manual Switch11. 3: Surge Arrestor12. 1:6 Window Annuciator13. 1: VAA 13 Relay.As per latest BIS norms. Make Servokon/L&K/ Kirloskar Electric/ Electricfeild/ ABB/ Schnieder Electric/ Stelmec ltd./ T-Power Transfomer & switchgear ltd. or its equivelent make.
62Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 180 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings: (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and asper CPWD specifications. (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubrication Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.(D) Base Frame & Foundation: Both the engine and alternator shall be mounted onsuitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required asper specifications.(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reactive Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following: 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/ Manual/ Test/ Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment. 9. Main supply failure monitor 10. Supply failure timer11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/ OFF/ Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring. As per latest BIS norms. Make Cummins/ Kirloskar Green/ Powerlux/ Eicher or its equivelant make.
63Supply, Installation, Testing, and Commissioning (SITC) of IS 15683 / CE / UL marked, stored pressure type ABC Multipurpose Fire Extinguisher of 4.0 kg capacity, charged with Monoammonium Phosphate powder (min. 50% MAP) and pressurized with Dry Nitrogen gas, complete with pressure gauge, discharge hose, nozzle, safety pin, wall mounting bracket, metallic fasteners, photo-luminescent instruction signage, testing certificates, and 1-year operational warranty, complete in all respects as directed by the Engineer-in-Charge
64Supply, Installation, Testing, and Commissioning (SITC) of IS 15683 / IS 2878 / CE / UL marked CO2 (Carbon Dioxide) Type Fire Extinguisher of 4.5 kg capacity, suitable for Class B and Electrical fires. The unit shall comprise a high-pressure seamless manganese steel / carbon steel cylinder conforming to IS 7285 / CCOE / PESO approval, charged with 99.5% pure industrial grade liquid CO2 gas. Complete with wheel/squeeze-lever type brass valve, safety relief valve, non-conductive frost-free discharge horn with hose/bend pipe, safety locking pin with tamper seal, heavy-duty wall mounting bracket/hook, metallic anchor fasteners, photo-luminescent instruction signage, factory pressure test certificates, CCOE/PESO certificate, and initial maintenance inspection tag, complete in all respects as per specifications and direction of the Engineer-in-Charge
65Supply, Installation, Testing, and Commissioning (SITC) of CE / ISO marked 1.3 kg Capacity Dry Powder Fire Extinguisher Ball (AFO / approved make), suitable for Class A, B, C, and Electrical fires. The unit shall feature dual-mode operation: automatic self-activation within 3 to 5 seconds upon direct flame contact at > 70 C -85 C emitting > 120 dB acoustic alarm), and manual throwing capability. Scope includes lightweight PVC casing filled with min. 50% MAP powder, circular wire mounting stand, wall fasteners, photo-luminescent signage complete in all respects.
66Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus 8.64 excavated soil as directed, within a lead of 50 metres Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus 8.64 excavated soil as directed, within a lead of 50 metres.
67Construction of DG set foundation at BOP by Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (as per direction and drawing provided by engineer-in-charge) a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
68Construction of DG set foundation at BOP by Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (as per direction and drawing provided by engineer-in-charge) b) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal sizederived from natural sources) )
69Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
70Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
7112 mm cement plaster of mix: 1:4 (1 cement: 4 fine sand)
72Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more.
73Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. as the direction Engg-in-charge (50x50x5) mm size. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57782644
AUTHORITY Government Departments
TENDER VALUE 1.63 Crore
LAST DATE 12-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Development Of Border Tourism At Shri Tanot Complex Jaislamer Sector, Rajasthan Under The Assistance To Central Agencies For Tourism Infrastructure Development Scheme Construction of Entrance Gate With Cabin, External Development, Substation Building, Hitheartre (Raj) (Sh: - Providing 11/0.415 Kv Sub-Stations, Ht & Lt Panels/ Cables And Shifting Of Dg Sets).
Basic Detail
Tender No 30/SE(E)/FTR-RAJ/2026-27
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 29 Sep 2026
Submission Date 12 Oct 2026
Open Date 29 Sep 2026
Finance
Tender Value 1.63 Crore
Tender Fee Ref. Documents
EMD 3.27 Lakhs
Exemption Not Available
Document List
8f302689-dffa-4dc5-a43a-083dcf976662.html
BOQ_975389.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.