Tender For special Repair To Bldg No P-21 (Mango Area) For 567 Int & Fs Unit Of Grd Mil Complex Gorakhpur Under Ge(Af) Gorakhpur.
Tender Value
45.18 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
16 days left
EMD
90400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Gorakhpur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bldg No P-21 (Mango Area) For 567 Int & Fs Unit Of Grd Mil Complex Gorakhpur Under Ge(Af) Gorakhpur.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition /striping out of existing roof treatment (tarfelt and roof plaster etc) including PCC padding of any discription and any thikness including backing and removal the debris complete all asspecified and directed. |
| 2 | M&L PCC in roof kerbs of mud stops, rounded or chamfered on edges and base of Over head tank type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and directed. |
| 3 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to removedust, etc brushing neat cement slurry with 3.0kg of cement per sq. metre complete all asspecified and directed. |
| 4 | M&L for 40 mm thick PCC roof padding 1:2:4 type B-0, 12.5 mm graded stone aggregate in floors , finished smooth .complete as specified and directed. |
| 5 | M&L for 10 mm thick screed bed or bedding layer of mortar in CM 1:3, using Liquid Water Proofing Compound as per manufacturer's instruction, laid in roof finisshed even and smoooth without using extra cement (WPC shall be paid separately) complete all asspecified and directed. |
| 6 | M&L for water proofing treatment to flat roofs and edges (vertical or tapered) etc. in following sequence:- (i) Properly cleaning and drying the surface(ii) Applying a coat of bitumen primer @ 0.40 Kg/Sqm (iii) Applying a coat of hot air blown grade bitumen 85/25 @ 1.2 Kg/Sqm (iv) Laying 3mm thick APP modified water proofing membrane with 100mm overlaps, sealed and bonded to the surface by 'torchon' method as per manufacturer's instructions complete all as specified and directed. |
| 7 | Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. |
| 8 | Supply only liquid water proofing compound complete all as specified and directed. |
| 9 | Disconnecting existing tank 500 ltrs, setting aside (or lowering if reqd) for repairs, cleaning etc, and hoisting if reqd reconnecting and refixing in position all as pacific SSR Part- I complete all as specified and directed. |
| 10 | S&Fin repair rotantional moulded polythylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top ) hoisted and fixed in position all as specified in SSR part-I complete all asspecified and directed. |
| 11 | Demolition of brickwork and portions ordered to be dismantled built in cement mortar or cement lime mortar complete all as specified as directed. |
| 12 | M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified as directed. |
| 13 | M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thickwalls built in 1:4 all as directed. |
| 14 | Taking down cement or lime plaster any description on brick or stone walls etc including recking out joints hacking for key scrubbing down with waters. complete all as specified as directed. |
| 15 | Rendering 15mm thick in cement mortar 1:6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all asspecified and directed.. |
| 16 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, chajja, fins facia etc upto 3 storie height mixed with water proofing compound (ISI marked) @ 2% by weight of cement or as per manufacturer’s instructions, finished even & smooth without using extra cement complete all as specified. Note 1: - Supply only water proofing compound shall be measured and paid for separately. 2. Cost of scafolding for rendering is incuded in this item. 2: Rendering will be done in two layer. 1st layer will be 10-12 mm thick and 2nd layer will be 3-5 mm thick. |
| 17 | M&L rendering 5mm thick 1:3 CM on fair face of concrete surface on ceiling finished even and smooth without using extra cement complete all asspecified and directed.. |
| 18 | Rendering 15mm thick in cement mortar 1:4 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all asspecified and directed. |
| 19 | Preparation of new plaster surfaces of wall and applying two coats of distemper oil emultion over a coat of primer/putty with roller complete all as specified as directed. |
| 20 | M&L for applying two or more coat of 100% premium acrylic emulsion paint having VOC less than 50gmLtr and UV resistance as per IS 15489:2004,Alkali & fungal resistant dirt resistance exterior paint of requiredshed (Company Depot Tinted ) with silicon additives @ 1.43 Litre /10 sqm over and including priming coat of exterior primer appied @ 0.90Litre /10sqm including removal of existring paint and height of building /over head tank is up to25 mtr complete all asspecified and directed.Note- Primer emmulsion to be carried out throught air less spray machine (Mechanical means). |
| 21 | M&L for Preparation of new plaster surfaces of wall and applying two coats of cement base paint over a coat of white cement primer complete all as specified as directed. |
| 22 | M&L for preparation of newly plastered of ceiling and three coat of white wash on ceiling surface complete all specified and directed. |
| 23 | M&L preparation of old painted steel surfaces of any description, over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and as directed . |
| 24 | M&L for preparation of old painted wooden based surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed. |
| 25 | M&L for preparation of old surfaces and applying one coat of oil bound distemper with roller on the old decoreted surface of ceiling surface complete all as specified and as directed. |
| 26 | M&L for complete removal of existing treatment from surface of wall and applying two coat of cement base paint and a coat of primer over complete all as specified and directed. |
| 27 | M&L for old preparation of surface and two coat of white wash on old ceiling surface complete all specified and directed. |
| 28 | M&L for demolition of stone slabs and tiles of any description or thickness in floors, aprons etc.laid bedded and pointed in any mortar complete all specified and directed. |
| 29 | S&F 20 mm Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like 20 mm cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite. |
| 30 | M&L Rounding to edges of stone slabs one edge, such as in steps,cooking platform, and other similar situations complete all specified and directed. |
| 31 | M&L For Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all specified and directed. |
| 32 | M & L for mirror polishing of marble/granite / Kota stone and other stone work, including cleaning, grinding, rubbing and polishing with suitable abrasives and polishing compounds, using mechanical polishing machine wherever required, to give smooth, uniform and high-gloss mirror finish, complete all as specified and directed. |
| 33 | Demolition of cement concrete (unreinforced) of any description and any position not otherwise specifically provided for complete all specified and directed. |
| 34 | M & L for 75 mm thick PCC 1:3:6 type C-1 using 20mm graded stone aggregate including finished surface even & fair without using extra cement as in plinth protection including necessary form work of edge all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr intervel and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio 1:3. complete all as specified and directed |
| 35 | Demolition of concrete of any description and in any position not other wise specifically provided for cement concrete reinforced including roof padding, Rcc Tank etc complete all as specified and directed. |
| 36 | M&L for RCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in chajja, fins, fascia and similar suspended work in bld upto 6M height incl use and waste of necessary formwork and scaffolding required |
| 37 | Mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips quality confirming to Fe-410-S 0r Fe-410-O. |
| 38 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all specified and directed. |
| 39 | S&F joint free non skid coloured ceramic tiles 7 to 8mm thick(square / rectangular ) area of each tile n.exceeding 0.11 sqm , in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 15 mm thick screed bed in cm 1:6 etc complete all specified and directed. |
| 40 | S&F Glazed ceramic coloured tiles 450x300x7mm thick in skirting dados risers to steps etc set and jointed in neat cement slurry and pointed in coloured cement to match tiles over 15mm thick rcement plaster in cm 1:4 complete all as specified as directed. |
| 41 | M&L Vitrified Ceramic double charged tiles 10 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured including Screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes complete all specified and directed. |
| 42 | Material and labour for treating the sunken floor with preparing surfaces by brushing with wire brushes for removing caked mud etc sweeping with brooms and finally fanning the cleaned surface with funny bags to remove all loose dirt etc, applying consisting of the following operation:-(a) 10mm thick plaster/screed bed in cement mortar 1:3 complete mixed with liquid water proofing compound as per manufactures instructions complete all as specified & directed (Note - WPC shall be measured and paid separately).(b) Cleaning floor surface by wire brush brooming & removing dust & shall be painted with a coat of bituminous primer conforming to IS : 3384-1986 @ 0.3 Ltr per Sqm uniformily complete all as specified & directed. (c) After primer the entire roof surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to 702-1988 @ 1.2 Kg per sqm over primer.(d) Over hot bitumen laying polymeric water proofing membrance conisting of 90 to 100 micron thick center core of HMHDPE Film with standard weight not less than 3 Kg per Sqm over entire area laid with 100mm side lap/end lap on prepared surfaces as per manufacture's technical instruction & sealed complete all as specified & directed.(e) Again the entire floor surface applying tack coat of hot blown bitumen grade 85/25 grade conforming to IS 702 @ 1.2 Kg per sqm. |
| 43 | S&F 40 mm tube galvanised iron light grade cut to required size as per site requirement to be placed in sunken portion of toilet/bathroom and taking out old pipe complete all specified and directed. |
| 44 | Material and labour PCC E-2, 1:5:10, using 40mm graded aggregate for filling of sunken portion including demolition of existing material/Treatment, all as specified and directed by Engineer In Charge complete all specified and directed. |
| 45 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all specified and directed. |
| 46 | S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed |
| 47 | S&F 75mm PVC (SWR) bends any radius complete all specified and directed. |
| 48 | S&F 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors |
| 49 | S&F 110mm PVC (SWR) bends any radius complete all specified and directed. |
| 50 | Taking down chowkats or frame not exc 1.5 sqm with shutter (with out taking of shutter from frame) all as specified and remooving from site. complete all specified and directed. |
| 51 | M & LProviding and fixing factory made uPVG white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed tomthe wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured for payment purpose.) |
| 52 | S&F 4.8 mm thick sheet glass, ordinary quality & glazing with oil putty/wooden beading/rubber packing around the glass in square including hacking out old glass of any description complete all as specified and as directed. |
| 53 | Taking down chowkats or frame exc 1.5 sqm and n.exe 4 sqm with shutter (with out taking of shutter from frame) all as specified and remooving from site complete all specified and directed. |
| 54 | S & F Solid pvc Door Frame of size 100mmx45 mm made out of 5mm wood grain colour PVC Sheet reinforced with MS Square etc complete all specified and directed. |
| 55 | Supplying and fixing in frame at site, factory made solid panel pvc moulded door shutter 28 to 30 mm thick (style) with 2,4,or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing specified in SSR part -II 2020 complete all as specified and directed. |
| 56 | S & F 100 mm long medium weight, cold rolled mild steel Butt hinges and fixed complete all specified and directed. |
| 57 | S & F 150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all specified and directed. |
| 58 | S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all specified and directed. |
| 59 | S & F 300 mm long MS sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts complete all specified and directed. |
| 60 | S&F Aluminium (extruded section ) body Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all specified and directed. |
| 61 | S&F for power coated aluminium (minimum thickness of powder coating 50 micron) work in doors, windows,venteleters, partitions ( fixed portion with extruded built up standared tubular sections/ appropriate Z sections and other sections of approved make conforming to IS 733 and IS 1285 fixing with dash fasteners of required dia and size inclu necessary fillings up the gaps at junctions i;e top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechinically wherever required inclu cleat angle, Aluminium snap beadingfor glazing/ panelling, CP brass/ staineless steel screws as as per direction by Engr-in Charge. |
| 62 | S&F anodised aluminium door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats glazing clips rubber neoprene packing anodised aluminium snap beading screws etc complete all as specifid power coating of any colour(thickness of power coating not less than 50 micron. complete all specified and directed. |
| 63 | M&L fixed in repairs for 12 mm thick pre laminated particle board, interior grade prelaminated one side with decorative choice lamination &other side balancing white lamination fixed in screws to timber frame work complete all specified and directed. |
| 64 | M/L for taking down and refixing the same existing aluminium door / windoow shutters for carrying out repairs as required, removing the existing beading and fixing new rubber beading of suitable size with adhesive, overhauling of floor springs including greasing and oiling as required complete all as required and as directed by engr-in-charge each shutter area n. Exc 2 Sqm. complete all specified and directed. |
| 65 | Hacking out old broken glass ( any thick ness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and provoding and fixing new ones complete all specified and directed. |
| 66 | S & F 4 mm thick Sheet glass, ordinary quality and glazing with wooden beads in squares not exceeding 0.5 Sq. M in each panel complete all specified and directed. |
| 67 | S&F for 15 mm thick Toughned glass door as in hinged doors, partitions doors and similar work including cutting to shape, drilling holes required. Fixed to position , all necessary asseriores path fitting floor spring heavy duty handles locking arrangment top pivote sets etc with forsted glass flim cutting shape design as required all as directed by eng in charge. |
| 68 | S& F in repair Prelaminated particle board 18/19mm thick, exterior grade, prelaminated one side with decorative choice lasmination & other side balancing white lamination in pelmet boxes,cup board shutters etc, rebated or flat edged with handle hinges complete all as specified as directed. |
| 69 | S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks or stainless steel wire staples.complete all as specified and directed. |
| 70 | Dismantling wrought iron or mild steel work of any description not otherwise provided forwindows grill etc.complete all specified and directed. |
| 71 | S&F framed work such as grills, gratings etc, with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusteres, walk ways, railings, frame work of water tanks and similar work complete all as specified and directed. |
| 72 | S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates to Fe-290 (Gde E- 165) complete all as specified |
| 73 | S&F in repairs 4mm dia plain mild steel wire, galvanised class 3 incu staining and fixing and incl necessary hooks for securing in wall/ceiling complete all specified and directed. |
| 74 | S&F in repairs Harrison rails, anodised aluminium alloy mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all specified and directed. |
| 75 | S&F solid PVC wall lining consisting of 5mm thick colour wood grained PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per spcifications and drawing complete all specified and directed. |
| 76 | S&F 5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frames as per specifications complete all specified and directed. |
| 77 | Taking up or down 15 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all specified and directed. |
| 78 | Taking up or down 20 mm bore steel tubing and connections, including cleaning for Refixing or removal to store complete all specified and directed. |
| 79 | Taking up or down 25 or 32 mm bore steel tubing and connections, including cleaning for Refixing or removal to store. |
| 80 | Supply and laying 20 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all brass fittings complete all as specified. |
| 81 | Supply and laying 25 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all brass fittings complete all as specified. |
| 82 | Supply and laying 32 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all brass fittings complete all as specified. |
| 83 | S&F in repair vitreous chaina squating pan orissa pattern size 680 x 470 mm white with intregal foot rest complete including lime concrete(excl flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc complete includig'S' or 'P' traps complete all as specified as directed. |
| 84 | S&F in repair Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) including provision of lime concrete bedding with Traps ‘P’ or ‘S’ complete in all respect all as specified |
| 85 | S&F in repairs 10 Litre capacity PVC low level flushing cistern with ball valve and handle/push button 32mm dia PVC flush pipe including taking down unserviceable cistern complete all as specified and directed. |
| 86 | S&F industrial heavy duty SS double wall double bowl sink ' Over all size 1143mm x 510mm and each bowl size 335mm x 450mm x200mm made of SS-304 grade stainless steel of minimum 1.2 mm5including fixing cantilever brackets and connecting union to pipe complete all as specified and directed. |
| 87 | S&F in repairs 15mm bore angular stop cock with flange screwed down high pressure with crutch or butter fly handdle screwed both end for iron pipe complete .Make-Jaquar-Code-CON -059KN or equivalent make specified in PS. |
| 88 | S&F in repairs 15mm bore bib cock with wall flange copper alloy screwed down high pressure with crutch or butter fly handdle screwed both end for iron pipe complete .Make-Jaquar-Code-CON-041KN or equivalent make specified in PS. |
| 89 | S&F in repairs 15 mm bore Pillar Tap fancy Type CP make jaquar Code OPP-1500PM or equivalent make specified in PS. |
| 90 | S & F in repairs cromimum plated helth faucet shower with CP flexible pipe up 15 mm bore (ABS Body) with 1 mtr long Easy Flex tube in chrome finish complete all as directed.Make-Jaquar-Code-ALD-573 or equivalent make specified in PS. |
| 91 | S&F in repairs chromium plated tubular towel rail,15 mm dia D type 60 cm long between flanges all as directed.Make -Jaquar code-AKP-35711P or equivalent make specified in PS. |
| 92 | S&F in repairs CP towel ring squre all as directed.Make:- code-CAN-1121N or equivalent make specified in PS. |
| 93 | S&F in repairs soap dish holder fixed to plugs with chromium plated brass screws all as directed.Make- Jaquar(code-ACN-1131N) or equivalent make specified in PS. |
| 94 | S&F in repairs Corner glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chomium plated bracket guard & railing 45 cm long all as directed.Make - Jaquar Code-ACN-1173 or equivalent make specified in PS. |
| 95 | S&F in repairs CP toilet paper roll holder with flap incl all necessary fittings. Make-Jaquar(Code-ACN-1151N) or equivalent make specified in PS. |
| 96 | S&F in repairs vitreous china wash basin white, table top size 510x350x115mm excluding taps , waste ,but including barkets. Make Jaquar cat No FLS-WHT-0575 or equivalent make specified in PS. |
| 97 | S&F in repairs for Urinal with size of Urinal 630x375x315 mm fixed in position as directed by Engr in charge. Make - Jaquar Code URS-WHT-0702N or equivalent make specified in PS. |
| 98 | S&F in repair brass chromium plated concealed valve of 15 mm bore complete all as specified and directed. |
| 99 | S&F in repairs CP Grating doom 125 mm dia with waste hole complete all as specified as directed. |
| 100 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified as directed. |
| 101 | S&F in repair chromium plated shower rose fixing with 15mm bore pipe min 40 grms including arm 15 mm size 195mm long with bend min wt 40 gms complete all as specified as directed. |
| 102 | S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified as directed. |
| 103 | S&F in repairs PVC connections 450mm long, 15 mm size with brass chromium plated nuts at ends complete fixed in repair complete all as specified and directed. |
| 104 | S&F PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified and directed. |
| 105 | M&L 75mm dia PVC (SWR) floor trap, plane with grating including jointing with solvent cement complete all as specified and directed. |
| 106 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. |
| 107 | Material and labour for One light, fan, bell point controlled by one switch point wiring with two single core 1.5 sqmm cable (nominal area) stranded copper conductor, PVC insulated unsheathed cable, 1100 V grade in and including concealed PVC conduit of size not less than 20mm dia with modular metal flush box, 1.6 mm thick of suitable size and modular white cover plate with frame of suitable module and wiring to be terminated in pressed steel sunken boxes including all accessories and using single core 1.5 Sqmm (nominal area) stranded copper conductor, PVC insulated unsheathed cable as in earth wire (green colour) connected to common earth dolly complete all as specified and directed for following :- |
| 108 | Ditto as above but for One 3 pin switch socket outlet point 5 Amps on independent board…ditto as above… |
| 109 | Ditto as above but for one 3 pin switch socket outlet point 5 Amps on same board with other switch….ditto as above… |
| 110 | All as per item above here in before but with copper conductor cable for one 3 pin socket outlet, 15 amp independent, with cable 2.5 sqmm size.….ditto as above… |
| 111 | M&L for Modular switch 1 way 6A, 1 module, flush button single pole, one way, complete as specified and directed by Engineer in charge. |
| 112 | M&L for Modular switch, 16 Amps, one module, one way complete all as specified and directed. |
| 113 | M&L for Modular socket outlet 2/3 pin combined 2 module, 6 Amps, 230 Volts AC circuit complete all as specified and directed by Engr-in-Charge. |
| 114 | M&L for Modular socket outlet 2 in 1, 6 pins 6A and 16A, combined 2 module, complete all as specified and directed by Engineer in charge. |
| 115 | S & Fix ceiling rose surface backlite 65x50mm 3 terminals complete. |
| 116 | Supply and fixing lamp holder PVC body with back plate complete all as specified and directed. |
| 117 | S&F Modular Fan step regulator, 120W - 2 module complete all as specified and directed. |
| 118 | M&L for Modular bell push 5 Amps 230 V, AC circuit complete all as specified and directed. |
| 119 | M&L for call bell ding dong 230 V AC circuit complete all as specified and directed by Engr-in-Charge. |
| 120 | Supply and fixing 4 Module SP box including Modular socket outlet 16 Amps , 240 Volts flush type white finish with MCB 16 Amps type 'C' flush mounted and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 2.5 Sqmm single core 1100 Volts grade FRLS PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accomodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 2.5 Sqmm single core 1100 Volts grade FRLS PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed. |
| 121 | Taking down old and u/s light fittings conventional type from wall surface / ceilling or any position and making good the disturbed surfaces all as specified and directed. |
| 122 | Supply and fix in replacement of Tube light fitting integrated type suitable for LED 20W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 123 | Supply and fix in replacement of Tube light fitting integrated type suitable for LED 10W indoor decorative aluminium extruded T5 LED batten complete with hosing with all accessories pre wired and making connection with three core copper flexible cable of size 23/0.0076 from ceiling rose to PVC connection to light fitting complete all as specified and directed. |
| 124 | Supply and fixing in replacement of LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light completewith driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. Make:- Havells Cat No. LHEBAEEP7IW1W036 or equivalent make specified in PS |
| 125 | Supply and fixing in replacement LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 126 | Supply and fixing in replacement LED Lamp 12W, 220V, AC complete all as specified |
| 127 | Supply and fixing in replacement GI Pipe bend to shape 1.5 mtr (32/40mm dia as required at site) with two Nos clamps made out of 50x6mm flat and two Nos bolts with nuts duly grouted in wall or fixing on wall complete all as specified and directed. |
| 128 | Taking down carefully unserviceable DB any type/size disconnecting and making good disturbed surfaces complete all as directed |
| 129 | Supply and fixing factory made epoxy powder coated distribution board double door TP & N 4 ways (VTPN MCB DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts including one FP MCCB/MCB 125 Amps as incomer and MCBs (or any combination of SP/TP MCBs ) outgoings complete all as specified & directed. |
| 130 | Supply and fixing factory made epoxy powder coated distribution board SPN 8 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, strandard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.Make :Indo asian Or eqvt make specified make in PS. |
| 131 | Taking down carefully unserviceable MCB SP/SPN/Isolator of any rating/size. complete all as specified and directed. |
| 132 | Supply and fixing MCB single pole 240 volt 'C' curve 10 KA 5 to 32 Amps capacity all as specified and directed incl taking down old one complete all as specified and directed. |
| 133 | Supply and fixing MCB single pole & neutral 240 volt 'C' curve 10 KA 25 to 32 Amps complete all as specified and directed . |
| 134 | Taking down old and u/s sub main wiring of 2/3 runs of any sizes from any position including, making good disturbed surface of wall ceiling etc all as directed. |
| 135 | M&L for concealed sub main wiring using two single core PVC insulated, unseathed stranded copper conductor cable of size 6.0 Sqmm of voltage rarting upto and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit) |
| 136 | Supply and fix exhaust fan made of steel body complete with louvers shutters , 300 mm sweep, single phase, 230 Volts AC, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed. |
| 137 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutters , 250mm sweep, single phase, 230 Volts AC,1200 RPM, ISI marked fixed properly at directed location with provisioning of suitable fixing/tightening arrangements and connecting/testing and including writing MES No complete all as specified and directed, |
| 138 | Taking down ceiling fan by unscrewing nut , bolts, disconnection of electric cable from ceiling rose, ceiling cable end, removing blades , of any sweep and make and deposit to MES Store all as specified and directed. |
| 139 | Supply & Fixing ceiling fan 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class of insulation : B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value ( CMM/W) minimum 6.00, Air delivery minimum 210 CMM 350 RPM ( tolerance as per IS : 374 - 2019), THD less than 10 % ,electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max), insulation resistance more than 2 mega ohm, suitable for 230 V , 50 Hz, single phase AC supply, earthing etc including necessary connection with ceiling rose with 3 core 1.0 Sqmm PVC insulated round flexible cable and including writing MES No all as specified and as directed. |
| 140 | Supply and fix water heater storage vertical type, puff insulation type of 25 ltrs capactiy and 1500 watts, BEE Star rated-5, with glass line inner shell with Hot & Cold pipe, water connection pipe, electric connection and necessary fixing arrangement and including writing MES No complete all as specified and directed. |
| 141 | Supply and fixed in replacement of down rod with anti sucide safe fan down rod of 260 mm length suitable for fixing in existing ceiling fan complete with nuts bolts, check nut and washers including making holes by drilling for bolts complete all as specified and directed. Make Gold Life Note:- (i) Anti sucide safe down rod will be active if load on fan exceeded 20.00Kg, then down rod pipe opens from middle and spring in pipe will expanded for landing smoothly of person trying to commit sucide. |
| 142 | M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to GI lead wire of 4 mm dia. by means of nuts, bolts and washers, checknuts of GI and protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test point etc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SI Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. |
| 143 | Supply, laying and testing XLPE insulated, screened PVC bedded galvanized steel strip or wire armoured electric power cables( heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core (at various locations) complete all as specified and directed. |
| 144 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation of laying cable including getting out in soft/loose soil complete all as specified and directed. |
| 145 | Returning, filling in, including spreading , watering and well ramming in layers not exceeding 25cm complete all as directed. |
| 146 | Removing of surplus soil to distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 147 | Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note: Punned thickness shall be measured for the purpose of payments. |
| 148 | Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engineer-in-Charge. |
| 149 | Supply and laying in replacment GI pipe medium grade with all fittings, ISI marked, in trenches/walls /cellings or laying in floors complete of size outer dia 25 mm ,including all fittings complete all as specified and directed. |
| 150 | Supply and fixing in replacment stop valves, cast copper alloy,secrewed down,high pressure with crutch or butter fly handle,fancy type ,screwed both ends for iron pipe or for unions and fixed of size 25mm dia bore complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender