Tender For Repair To Roof Sheeting, Roof Treatment And Other Connected Works In Tech Area At Afs Chakeri Kanpur
Tender Value
45 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
18 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur Nagar → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair To Roof Sheeting, Roof Treatment And Other Connected Works In Tech Area At Afs Chakeri Kanpur
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of concrete including top finish of any type by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed. |
| 2 | M&L for plain cement concrete type B0 (1:2:4 ) using 12.5 mm graded stone aggregate as in padding, coping, roof kerb including hunching, benching etc with non shrink chemical and curing with curing compound complete all as specified and directed. Note :- Unit rate quoted by contractor shall be deemed to inclusive rate of non shrink chemical and curing compound. Contractor shall quote his rate accordingly. |
| 3 | M&L for 10 mm thick in CM(1:3) rendering on fair faces concrete surfaces/roof top mixed with water proofing compound finished even & smooth without using extra cement complete all as specified and directed.Note :WPC shall be measured and paid separately under respective items of schedule. |
| 4 | M&L for Preparation of plastered roof surface by cleaning surface free from dust and other foreign materials etc. and laying in repair Atatic poly propylene polymer modified membrane pre fabricated 3mm thick with non woven polyester matt central core of 160 gms/Sqm weighing not less than 3.5kg per sqm laid over primer conforming to IS 3384 @ 0.4 lit/sqm by using LPG/Butane torch and applying uniform pressure with a roller with overlap of 100mm in longitudinal direction and 150mm in transverse direction laid as per manufacturers instructions complete all as specified and directed by Engineer-in-Charge with and including following courses of descriptions given below :-(a) A coat of bonding material using blown grade bitumen 85/25 confirming to IS-702 @ 1.20 Kg per Sqm.(b) Laying of APP modified membrane described hereinbefore with joints sealed with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and curved well before lying the membrane. |
| 5 | M & L Painting with superior quality aluminium paint of approved make and brand over the top surface of APP membrane in two coats complete all as specified and directed. |
| 6 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 7 | M&L for Disconnecting existing tanks, exc 250 & n. exc. 500 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisted if required reconnecting and refixing in position complete all as specified and directed. |
| 8 | M&L for Disconnecting existing tanks, exc 500 & n. exc. 1000 ltrs capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisted if required reconnecting and refixing in position complete all as specified and directed. |
| 9 | Taking down steel water tubing of 15 mm dia bore including connection & from site, complete all as specified and directed.. |
| 10 | Taking down steel water tubing of 20 mm dia bore incl connection & from site, complete all as specified and directed.. |
| 11 | S & F GI tubing 15 mm bore medium weight fixed to wall including all required fitting etc complete all as specified and as directed. |
| 12 | All as per item No 11 above but except GI tubing complete all as specified and as directed. |
| 13 | GI tubing 20 mm bore medium weight fixed to walls including all necessary required fittingscomplete all as specified and as directed. |
| 14 | All as per item No 13 above but except GI tubing complete all as specified and as directed. |
| 15 | Supply and fix in repair 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed. complete all as specified and as directed. |
| 16 | S&F in repair 15mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed , complete all as specified and directed.. |
| 17 | All as per item No. but 20 mm dia --Ditto-- |
| 18 | Dismantling of plain or corrugated steel sheeting, any gauge or thickness at any position or similar pattern of roof covering complete all as specified and directed. |
| 19 | Dismantling of Asbestos cement corrugated and semi corrugated sheets in roof covering complete all as specified and as directed by the Engineer-in-charge. |
| 20 | S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as directed. |
| 21 | S & F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as directed. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed |
| 23 | S & F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. cut to ordinary lengths conforming to Fe-410 (Gde E-250) complete all as specified and as directed. |
| 24 | Fixing only rolled sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.complete all as specified and as directed. |
| 25 | S&F fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugation side lap fixed with coach screw and washer or self tapping screw in roof, wall etc,including taking down old sheet complete all as specified and directed. |
| 26 | S & F wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165. complete all as specified and as directed |
| 27 | Dismantling of Brick work / stone masonry built in cement mortar complete all as specified and directed. |
| 28 | M&L brick work with sub class B bricks old size bricks, straight or curved on plan exc 6 metre mean radius built in CM 1:6, all as specified and directed. |
| 29 | All as per item No 28.00 above but except bricks complete all as specified and as directed. |
| 30 | M&L for rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 finished even and smooth complete all as specified and as directed. |
| 31 | M & L for preparing new plastered surface and applying two coats of cement base paint complete all as specified and as directed. |
| 32 | Taking down cement plaster on brick or stone walls exposing the surface till brick level, as specified and directed. |
| 33 | S & Fix in repair wind driven turbo ventilators of 600 mm size with fixing sheet. The top portion shold be made of aluminium with power coating, The shaft and varipitch should be made of stainless steel and aluminium respectively alongwith heavy quality ball bearing system without FRP base complete all as specified and directed by Engineer -in-Charge. |
| 34 | All as per item no. 33 but with FRP corrugated base sheet |
| 35 | Taking down eaves, gutters and rain water pipes any size and pattern including all fittings complete all as specified and as directed |
| 36 | S & F UPVC rain gutter pipe of dia 250mm and made up in shape of half circle as in valley gutters end connection jointed with elastomeric rubber seal as approved by GE complete all as directed by Engr in charge |
| 37 | PVC pipes 160 mm bore single socketed in any length of pressure rating 4 Kg/Sqcm with or without rubber ring joints fixed to Hanger wall. |
| 38 | S&F PVC SWR bend/shoe of any radius for 160 mm dia complete all as specified and directed. |
| 39 | S&F of MS Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 40 | Dismantling of wall and ceiling boards any type (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets any thickness including cover fillets all as directed. |
| 41 | S&F 16mm thick of size 600 x 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular ) including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping ,main runner and cross runner and to comprise main tee/runner 15 mm x 38mm size (load carring capacity 14 kg /sqm ) spaced at 1200 mm centres securely fixed to the structural sofit and flush fitting 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module , cut sub cross tee/runner 600mm require independent support ,wall angle of size 19mm x 19mm secured to the periphery of the wall at 450 mm maximum centre the above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350mm , complete all as specified and directed |
| 42 | Supply and fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and pattern having moister content less than 2%, humidity resistant of 99%, NRCO.50 to 0.75 as per IS 8225:1987, noncombustible as per BS 476 (part 4) - 1970 and light reflectance of 85% minimum to be laid in true horizental level suspended on inter-locking metal T-Grid of hot dipped galvanised ireon section of 0.33mm thick (galvanised @120gm/Sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm, cross T of size 15 x 32 mm of length 1200mm and secondary intermediate corss T of size 15 x 32 mm of length 600mm to from grid module of size 600x 600 mm suspended from ceiling using galvanised mild steel items (galvanised @ 80gm/Sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm centre to centre and 40mm long dry wall wood screws. The work shall be carried out as per specifiection, drawing and as per directed of Engineer-in-Chagre. |
| 43 | Refixing only the depressed/sagged portion of existing false ceiling grid system of any description after taking down existing ceiling board of any description and refixing the same in position. Note- The quoted unit rate include supply and fixing 4 mm dia GI bar hanger and fly clip if required in refixing. |
| 44 | S&F 16 mm thick of size 595 x 595mm or 600 x 600 mm mineral fibre false ceiling board of pattern classic lite RH -99 (Bevelled tegular) of armstrong or equivalent make including taking down old ceiling board from existing snap grid complete all as specified and directed. |
| 45 | S&F of 12mm thick false ceiling at all heights with semi perforated micro tegular edged GRG (Glass fibre Reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and pattern fibre false ceiling board including taking down old ceiling board from existing snap grid complete all as specified and directed. |
| 46 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed. |
| 47 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. laid over and including 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 48 | M&L for Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tilesnot exceeding 0.36 sqm, in dado/skirting etc. and including 10 mm thick backing coat in CM 1:4 and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed. |
| 49 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.complete all as specified and as directed |
| 50 | M & L for Kota Stone 20 - 25 mm thick laid over and including 15mm thick screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match including rendering, moulding & polishing on exposed edges & complete all as specified and directed. |
| 51 | M & L for Kota Stone 20 - 25 mm thick as in skirting laid over and including 10 mm thick cement plaster in CM 1:4, fixed and jointed with grey cement slurry mixed with pigment to match complete all as specified and directed. |
| 52 | M&L for 25 mm thick PCC type B-0 1:2:4 (using 12.5 mm graded stone aggregate) as in leveling /sub base of flooring complete all as specified and directed. |
| 53 | M&L for servicing existing unservicable steel rolling shutter of any size and dimension and its operating box including replacement of any operating part like helical spring etc. complete all as specified and directed |
| 54 | M&L for servicing existing main steel sliding hangers doors leaf by aligning cleaning/oiling/ greasing and including cleaning rails of shutter movement complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender