Tender For Re-Arrangment & Up Gradation Of Entire Electrical Distribution System Including Replacement Of Batten Wirings And Installation Of Extra Plug Points In The Ranibhawani Girls Hostel At N.B.U. Main C Us
Tender Value
21.91 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
11 days left
EMD
43830
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Darjeeling → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Re-Arrangment & Up Gradation Of Entire Electrical Distribution System Including Replacement Of Batten Wirings And Installation Of Extra Plug Points In The Ranibhawani Girls Hostel At N.B.U. Main C Us
BOQ
| Sl. No. | Item Description |
| 1 | Re-arrangment & up gradation of entire electrical distribution system including replacement of batten wirings and installation of extra plug points in the Ranibhawani Girls Hostel at N.B.U. main Campus” |
| 2 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish [PVC casing capping on surface and Switch board concealed]a) Avg Run 5 M |
| 3 | b) Avg Run 8 M |
| 4 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as requireda) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC |
| 5 | Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC)of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.a) 2 x 2.5 Sq mm + 1 x 1.5 sq mm |
| 6 | b) 2 x 4 sq mm + 1 x 2.5 sq mm |
| 7 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 8 | Supply & Fixing 240 V 16 A Modular type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 9 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc |
| 10 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 11 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 12 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 13 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.a) 2 Module |
| 14 | Supplying & Fixing GI Modular Switch Board of the followingsizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksa) 6 Module |
| 15 | b) 2 Row 12 Module |
| 16 | Supplying and fixing double-door (2 + 10) Ways SPN MCB Distribution Board (Legrand/Seimens/ABB/L&T) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 17 | Supplying and fixing double door Horizontal TPN MCB Distribution board (Legrand/Seimens/ABB/L&T) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provisionfor earthing attachment a) 4 Ways |
| 18 | b) 6 Ways |
| 19 | C) 8 Ways |
| 20 | Supplying and fixing double door Up to 160A Vertical TPN MCB Distribution board (Legrand/Seimens/ABB/L&T) for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmenta) 4 Ways |
| 21 | b) 6 Ways |
| 22 | c) 8 Ways |
| 23 | Supplying and fixing 240/415 V MCB (Legrand/Seimens/ABB/L&T) of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectiona) 6A-32A S.P |
| 24 | b) 16 - 32 A D.P |
| 25 | c) 40A/63A T.P |
| 26 | d) 63A T.P.N |
| 27 | Supplying and fixing 415 V Four Pole MCCB (Legrand/Seimens/ABB/L&T) of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connectiona) 63 A |
| 28 | b) 100 A |
| 29 | c) 125 A |
| 30 | Supplying and fixing 415V, 160A TPN on load front operated Changeover switch (Seimens/ABB/L&T)open execution type in SS enclosure / cubical with nuts bolts etc |
| 31 | Supply & Fixing of perforated GI cable tray cross member with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.a) 200x50x1.25mm (18SWG) |
| 32 | Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed |
| 33 | Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 34 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 35 | Laying of cable upto 50 sq mm, on existing Cable Tray and binding with suitable size GI wire. |
| 36 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :a) 2 core x 10 sq mm |
| 37 | b) 3.5 core x 25 sq mm |
| 38 | c) 3.5 core x 50 sq mm |
| 39 | d) 3.5 core x 70 sq mm |
| 40 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials a) 2 core x 10 sq mm |
| 41 | b) 3.5 core x 25 sq mm |
| 42 | c) 3.5 core x 50 sq mm |
| 43 | d) 3.5 core x 70 sq mm |
| 44 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.a) 2.5 sq mm |
| 45 | b) 4 sq mm |
| 46 | c) 6 sq mm |
| 47 | Supplying & fixing medium gauge 50 mm dia. GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 48 | Excavation of soil for installation of Earth Electrode and filling & ramming.(a) For Soft Soil |
| 49 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia. x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:(a) By ISI-Medium GI pipe |
| 50 | Extra for treatment of soil by using salt & charcoal or coke for plate electrode |
| 51 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc. |
| 52 | Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 53 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: |
| 54 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall with necy. bolts & nuts (6 mm dia x 62 mm long)a) 30 cm Exhaust fan (12\\") |
| 55 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 56 | Fixing only single/twin fluorescent light fitting complete with allaccessories directly on wall/ceiling by screws etc. |
| 57 | Fabrication, Supply & Installation of double door outdoor type both side openable feeder pillar box. Size of the box – (1.2M x 0.6m x 1.4M) construction having crown top made by CRCA sheet (Crown top and support frame by 3mm and rest of part by 2mm) with powder coated paint. Angle iron for frame work and base channel or angle leg shall be provided at the bottom as per weight of feeder pillar. Well ventilation, locking arrangement dust proof, two point for body ear-thing and proper support for incoming and out-going cable shall also be provided. The feeder pillar has comprising of copper bus-bar with separate compartment (3 phase neutral shall be high conductivities electrolytic copper high PVC heat shrinkable sleeves with suitable colour coding.) including supply of digital voltmeter (500V), ampere meter (500A), CT coil, danger board, fuse unit with indicator lamp etc. The feeder pillar shall have provision for 2nos MCCB ( as incomer) with TPN on-load front operated change over switch and 4nos. MCCB(out-going) with separate compartment for each part, including supply of proper size of copper bar to inter-connection of incomer and out-going switches and internal wiring complete set on brick foundation (size of the foundation 4.5’ x 2.5’ x 4.5’) including necessary plaster & neat cement punning as per the satisfaction & direction of the Engineer-in-charge. (Front size of feeder pillar is 18.08 sq. ft.) |
| 58 | Supply of 1.1 Kv grade XLPE / PVC armored Alluminium cables (brand approved by the EIC) a) 2 core x 10 sq mm |
| 59 | b) 3.5 core x 25 sq mm |
| 60 | c) 3.5 core x 50 sq mm |
| 61 | d) 3.5 core x 70 sq mm |
| 62 | Add GST @ 18.00 % |
| 63 | Add L W Cess@ 1.00% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender