Tender For Electrical Re-Wiring/ Replacement Of Bungalow No -1494 In Bbmb Colony Sector 35-B Chandigarh.
Tender Value
3.20 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
5 days left
EMD
6420
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Re-Wiring/ Replacement Of Bungalow No -1494 In Bbmb Colony Sector 35-B Chandigarh.
BOQ
| Sl. No. | Item Description |
| 1 | 36w LED Tube Light. NS item |
| 2 | Wall Fancy Light. NS item |
| 3 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four-way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- CSR item No. 34.02 (i) a Wiring fan point (Without fan box) |
| 4 | (ii) Wiring light point. CSR item No. 34.02 (ii) |
| 5 | (iii) Wiring call-bell point. CSR item No. 34.02 (iii) |
| 6 | (iv) Wiring 6Amp. wall socket point. CSR item No. 34.02 (iv) |
| 7 | (vi) Wiring 16/20Amp. power plug control point. CSR item No. 34.02 (vi) |
| 8 | RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES): Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.CSr item No. 34.01 (ix) |
| 9 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (i) Overall size 1sq.mm (Un-sheathed). CSR item No. 34.09 (i) . |
| 10 | ii) Overall size 1.5sq.mm (Un-sheathed). CSR item No. 34.09 (ii) |
| 11 | (iii) Overall size 2.5sq.mm (Un-sheathed). CSR item No. 34.09 (iii) |
| 12 | (iv) Overall size 4sq.mm (Un-sheathed). CSR item No. 34.09 (iv) |
| 13 | (vi) Overall size 10sq.mm (Un-sheathed).CSR item No. 34.09 (vi) |
| 14 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- (ii) MCB Single Pole 6-32amp. (10kA, Curve-C). CSR item No. 34.16 |
| 15 | RCBO's: Supply and erection of RCBO (Residual Current Breaker Overload) for Earth leakage, overload and short circuit protection suitable for 240/415 volts 50 cycles AC supply with breaking capacity of 10kA as per IEC 61009 in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs: - (iv) RCBO Double Pole 63amp., Sensitivity 30mA. CSR item No. 34.16 (B) (iv) |
| 16 | xii) RCBO Four Pole 63amp., Sensitivity 30mA. CSR item No. 34.16 (B) (xii) |
| 17 | (xiv) Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) and with G.I. reducing socket including erection of the same, 10.50 metre (34.44 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 14 metre in length (including boring & refilling). (a) Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 14Metre in length). CSR item No. 34.13 (xiii) (a) |
| 18 | SHEET METAL BUS BAR CHAMBERS (COPPER STRIPS): Supply and erection of sheet metal busbar chamber (factory fabricated) duly powder coated on existing surface with required 4Nos. of tin plated copper busbar strips of suitable length and cross sectional area mounted on DMC/ SMC moulds at sufficient distance, enclosure made of M.S. sheet 1.6mm thick with hinged cover and lock, fitted with dust excluding gaskets and secured with sufficient no. of cadmium plated iron screws and of given overall dimensions and to be fixed with G.I. bolts and nuts/ rag bolts and nuts etc. complete with all accessories including connections with suitable size of thimbles, bonding to the existing earth and painting etc. as desired by the Engineer-in-charge at site:- (ii) Bus Bar Chamber 63amp., 415volts Overall Dimensions (350mm x 450mm x 150mm) nominal. CSR item No. 34.20 (ii) |
| 19 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure): Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications: - (ii) On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure). CSR item No. 34.22 (A) (ii) |
| 20 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB's/ RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- (viii) TP&N Horizontal Double Door Distribution Board 12 way each. CSR item No. 34.17 (viii) |
| 21 | (ii) SP&N Double Door Distribution Board 8 way each. CSR item No. 34.17 (ii) |
| 22 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537: Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications: - (x) Heavy Gauge PVC Conduit Pipe 25mm dia.(Flushed). CSR item No. 34.12 (x) |
| 23 | ERECTION OF FANS: Erection of Ceiling/ Cabin/ Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete: - Erection of Ceiling fan. CSR item No. 34.28(A) (i) (a) |
| 24 | Erection of Exhaust fan with louver shutter on the wall/ window grill. CSR item No. 34.28 (A) (i) © |
| 25 | Erection of light fixtures on wall/ ceiling having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete: - Erection of 1X28/36/40W and 2X28/36/40W Mirror optics (LED/ Fluorescent) light fixture.CSR item No. 34.28 (A) (ii) (b) |
| 26 | DISMANTLING WIRING POINTS & FITTINGS: Dismantling old wiring points includeing necessary repairs to wall etc: - Fan, light or call bell point.CSR item No. 34.39 (i) |
| 27 | Wall socket, power plug point.CSR item No. 34.39 (ii) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 15, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender