Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #57772504

Tender For Special Repair Replacement Of Lt Oh Line To Underground Electric Cable Against Job No W/Sr (E/M)-03/Stn Hq Khunmoh/2025-26 At Khunmoh Grn Under Ge 861 Ews

Issued by Statutory Bodies & Commissions/Committees · Anantnag, Jammu and Kashmir
Tender Value
20.43 Lakhs
Estimated cost
Bid Submission
21 Oct 2026
17 days left
EMD
40900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Special Repair Replacement Of Lt Oh Line To Underground Electric Cable Against Job No W/Sr (E/M)-03/Stn Hq Khunmoh/2025-26 At Khunmoh Grn Under Ge 861 Ews

BOQ

Name of Work:- SPECIAL REPAIR REPLACEMENT OF LT OH LINE TO UNDERGROUND ELECTRIC CABLE AGAINST JOB NO W/SR (E/M)-03/STN HQ KHUNMOH/2025-26 AT KHUNMOH GRN UNDER GE 861 EWS
Sl. No. Item Description
1Dismantling and taking down existing ACSR conductor of any size by opening the binding wire from LT elctric poles complete all as specified and directed by Engineer-in-Charge.
2Taking down insulators off anysize and any type complete all as specified and directed by Engineer-in-Charge.
3Taking down cross arms,channels,angle iron,clamps,nut,bolts,stay wire,stay assembly,GI wire,anti climbing devices,danger notice boards etc complete all as specified and directed by Engineer-in-Charge.
4Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 185 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
5Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 120 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
6Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 95 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
7Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
8Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
9Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
10Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2.00 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately)
11Supply and Fabrication, installation , testing and commissioning out door type sub panel of size 1.00 mtr x 0.9mtr x 0.45mtr with canopy at top , fabricated with 3.15 mm thick made of CRCA, powder coated 3 Phase 4 wire mounted on PCC platform including with alumiium busbar of capacity 150 Amp with minimum 60cm ground clearence with following complete all as specified and directed by Engineer-in-Charge:-(a) MCCB 4 Pole 415 Volts 63 Amps 25KA – 01 No. (Incoming)(b) MCCB 4 pole 415 volts 32 Amps 25KA – 03Nos. (Outgoing)(c) MCB TP 63 Amps 'C' Curve , 10KA -01 No. (Outgoing)(d) Voltmeter digital type-01 No(e) Ammeter 0-100 Amp-01 No(f) Indicator (RYB)-03 Nos.
12Supply and Fabrication, installation , testing and commissioning out door type sub panel of size 1.00 mtr x 0.9mtr x 0.45mtr with canopy at top , fabricated with 3.15 mm thick made of CRCA, powder coated 3 Phase 4 wire mounted on PCC platform including with alumiium busbar of capacity 400 Amp with minimum 60cm ground clearence with following complete all as specified and directed by Engineer-in-Charge:-(a) MCCB 4 Pole 415 Volts 250 Amps 36 KA – 01 No. (Incoming)(b) MCCB 4 Pole 415 Volts 160 Amps 36 KA – 01 No. (Outgoing)(c) MCCB 4 Pole 41 Vvolts 32 Amps 25 KA-07 Nos. (Outgoing)(d) MCB TP 63 Amps 'C' Curve , 10KA -01 No (Outgoing)(e) Voltmeter digital type-01 No.(f) Ammeter 0-100 Amp-01 No(g) Indicator (RYB)-03 Nos
13Supply and Fabrication, installation , testing and commissioning out door type sub panel of size 1.00 mtr x 0.9mtr x 0.45mtr with canopy at top , fabricated with 3.15 mm thick made of CRCA, powder coated 3 Phase 4 wire mounted on PCC platform including with alumiium busbar of capacity 240 Amp with minimum 60cm ground clearence with following complete all as specified and directed by Engineer-in-Charge:-(a) MCCB 4 Pole 415 Volts 160 Amps 36 KA – 01 Nos (Incoming)(b) MCCB 4 Pole 415 Volts 100 Amps 36 KA – 01 Nos (Outgoing)(c) MCCB 4 Pole 415 Volts 32 Amps 25KA-05Nos (Outgoing)(d) MCB TP 63 Amps 'C' Curve , 10KA -01 No (Outgoing)(e) Voltmeter digital type-01 No(f) Ammeter 0-100 Amp-01 No(g) Indicator (RYB)-03 Nos
14Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 32mm x 6mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI strip 32mm x 6mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge.
15Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes,poles etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed by Engineer-in- charge.
16Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil (hard/dense) complete all as spefied and as directed by Engineer-in-Charge.
17Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as spefied and as directed by Engineer-in-Charge.
18Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as spefied and as directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose)
19Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge.
20Supply and Laying GI tubing 100mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'BoQ.
21Supply and Laying GI tubing 80mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'BoQ.
22Supply and Laying GI tubing 40mm bore Light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'BoQ.
23Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57772504
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 20.43 Lakhs
LAST DATE 21-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Replacement Of Lt Oh Line To Underground Electric Cable Against Job No W/Sr (E/M)-03/Stn Hq Khunmoh/2025-26 At Khunmoh Grn Under Ge 861 Ews
Basic Detail
Tender No GE 861 EWS-37(T)/2026-27
Bidding Type Tender
Location
City Anantnag
State Jammu and Kashmir
Key Dates
Publish Date 29 Sep 2026
Submission Date 21 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 20.43 Lakhs
Tender Fee 500
EMD 40900
Exemption Not Available
Document List
509cc32e-50e3-4466-bae3-cab0b8bdaa5d.html
BOQ_887262.xls
NIT37T.pdf
Tender37T.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

509cc32e-50e3-4466-bae3-cab0b8bdaa5d.html

xls

BOQ_887262.xls

pdf

NIT37T.pdf

pdf

Tender37T.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders