Tender For Rate Contract For Day To Day Electrical Work At Sms Medical College Jaipur
Tender Value
25 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
6 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rate Contract For Day To Day Electrical Work At Sms Medical College Jaipur
BOQ
| Sl. No. | Item Description |
| 1 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 2 | Short point (up to 3 mtr.) |
| 3 | Medium point (up to 6 mtr.) |
| 4 | Long point (up to 10 mtr.) |
| 5 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 6 | Short point (up to 3 mtr.) |
| 7 | Medium point (up to 6 mtr.) |
| 8 | Long point (up to 10 mtr.) |
| 9 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 10 | On board |
| 11 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required. |
| 12 | 20 mm |
| 13 | 25 mm |
| 14 | 32 mm |
| 15 | 40 mm |
| 16 | 50 mm |
| 17 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 18 | Short point (up to 3 mtr.) |
| 19 | Medium point (up to 6 mtr.) |
| 20 | Long point (up to 10 mtr.) |
| 21 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 22 | Short point (up to 3 mtr.) |
| 23 | Medium point (up to 6 mtr.) |
| 24 | Long point (up to 10 mtr..) |
| 25 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 26 | On board |
| 27 | Short point (up to 3 mtr.) |
| 28 | Medium point (up to 6 mtr.) |
| 29 | Long point (up to 10 mtr..) |
| 30 | S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required. |
| 31 | 16 mm OD |
| 32 | 20 mm OD |
| 33 | 25 mm OD |
| 34 | 32 mm OD |
| 35 | 40 mm OD |
| 36 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. |
| 37 | Short point (up to 3 mtr.) |
| 38 | Medium point (up to 6 mtr.) |
| 39 | Long point (up to 10 mtr.) |
| 40 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 41 | Short point (up to 3 mtr.) |
| 42 | Medium point (up to 6 mtr.) |
| 43 | Long point (up to 10 mtr.) |
| 44 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. |
| 45 | On board |
| 46 | S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required. |
| 47 | 20 mm |
| 48 | 25 mm |
| 49 | 32 mm |
| 50 | 40 mm |
| 51 | 50 mm |
| 52 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 53 | Short point (up to 3 mtr.) |
| 54 | Medium point (up to 6 mtr.) |
| 55 | Long point (up to 10 mtr.) |
| 56 | Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 57 | Short point (up to 3 mtr.) |
| 58 | Medium point (up to 6 mtr.) |
| 59 | Long point (up to 10 mtr..) |
| 60 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. |
| 61 | On board |
| 62 | S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required. |
| 63 | 20 mm x 12 mm |
| 64 | 25 mm x 12 mm |
| 65 | 32 mm x 12 mm |
| 66 | 38 mm x 25 mm |
| 67 | 50 mm x 16 mm |
| 68 | 50 mm x 50 mm |
| 69 | 75 mm x 50 mm |
| 70 | 100 mm x 50 mm |
| 71 | 100 mm x 100 mm |
| 72 | 150 mm x 50 mm |
| 73 | 150 mm x 100 mm |
| 74 | Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. |
| 75 | 1 x 1.5 sq.mm |
| 76 | 2 x 1.5 sq.mm |
| 77 | 3x 1.5 sq.mm |
| 78 | 4 x 1.5 sq.mm |
| 79 | 1 x 2.5 sq.mm |
| 80 | 2 x 2.5 sq.mm |
| 81 | 2 x 2.5 sq. mm. + 1x1.5sqmm |
| 82 | 3 x 2.5 sq.mm |
| 83 | 4 x 2.5 sq.mm |
| 84 | 1 x 4.0 sq.mm |
| 85 | 2 x 4.0 sq.mm |
| 86 | 3 x 4 sq. mm. |
| 87 | 4 x 4.0 sq.mm |
| 88 | 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. |
| 89 | 1 x 6.0 sq.mm |
| 90 | 2 x 6.0 sq.mm |
| 91 | 3 x 6.0 sq. mm. |
| 92 | 4 x 6.0 sq.mm |
| 93 | 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. |
| 94 | 2 x 6.0 sq. mm. + 1 x 4.0 sq. mm. |
| 95 | 1 x 10.0 sq.mm |
| 96 | 2 x 10.0 sq.mm |
| 97 | 4 x 10.0 sq.mm |
| 98 | 1 x 16.0 sq.mm |
| 99 | 2 x 16.0 sq.mm |
| 100 | 4 x 16.0 sq.mm |
| 101 | Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size. |
| 102 | 5 pair |
| 103 | 10 pair |
| 104 | Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 105 | 1.5 Sq.mm 3 core flat / Round |
| 106 | 2.5 Sq.mm 3 core flat / Round |
| 107 | 4.0 Sq.mm 3 core flat / Round |
| 108 | 6.0 Sq.mm 3 core flat / Round |
| 109 | 10.0 Sq.mm 3 core flat / Round |
| 110 | 16.0 Sq.mm 3 core flat / Round |
| 111 | Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required. |
| 112 | 0.75 sq.mm |
| 113 | 1.0 Sq. mm |
| 114 | Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required. |
| 115 | 1.5 sq.mm x 3 core |
| 116 | 1.5 sq.mm x 4 core |
| 117 | 1.5 sq.mm x 6 core |
| 118 | 1.5 sq.mm x 8 core |
| 119 | 2.5 sq.mm x 3 core |
| 120 | 2.5 sq.mm x 4 core |
| 121 | 2.5 sq.mm x 6 core |
| 122 | 2.5 sq.mm x 8 core |
| 123 | 4.0 sq.mm x 3 core |
| 124 | 4.0 sq.mm x 4 core |
| 125 | 4.0 sq.mm x 6 core |
| 126 | P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required. |
| 127 | 75mm x 75mm x 60mm |
| 128 | 100mm x 100mm x 60mm |
| 129 | 150mm x 75mm x 60mm |
| 130 | 175mm x 100mm x 60mm |
| 131 | 150mm x 150mm x 60mm |
| 132 | 225mm x 100mm x 60mm |
| 133 | 200mm x 150mm x 60mm |
| 134 | 200mm x 125mm x 75mm |
| 135 | 200mm x 250mm x 75mm |
| 136 | 200mm x 250mm x 100mm |
| 137 | 250mm x 300mm x 75mm |
| 138 | 250mm x 300mm x 100mm |
| 139 | 300mm x 375mm x 75mm |
| 140 | 300mm x 375mm x 100mm |
| 141 | 250mm x 100mm x 60mm |
| 142 | 300mm x 100mm x 60mm |
| 143 | 300mm x 300mm x 75mm |
| 144 | P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required. |
| 145 | 3.0 mm thick |
| 146 | 5.0 mm thick |
| 147 | 6.0 mm thick |
| 148 | P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required. |
| 149 | 75 mm dia |
| 150 | 100 mm dia. |
| 151 | P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. |
| 152 | 75 mm dia. |
| 153 | 100 mm dia. |
| 154 | P & F Aluminium sheet 1.0 m thick of following size dia. Including screws, cup washer as required. |
| 155 | 75 mm dia. |
| 156 | 100 mm dia. |
| 157 | P & F 1.2 mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required. |
| 158 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 159 | Single pole MCB (With B / C curve tripping characteristics) |
| 160 | 0.5 A to 5 A rating |
| 161 | 6 A to 32 A rating |
| 162 | 40 A rating |
| 163 | 50/63 A rating |
| 164 | 80 A rating |
| 165 | 100 A rating |
| 166 | 125 A rating |
| 167 | Double pole MCB (With B / C curve tripping characteristics) |
| 168 | 0.5 A to 5 A rating |
| 169 | 6 A to 32 A rating |
| 170 | 40 A rating |
| 171 | 50/63 A rating |
| 172 | 80 A rating |
| 173 | 100 A rating |
| 174 | 125 A rating |
| 175 | Triple pole MCB (With B / C curve tripping characteristics) |
| 176 | 6 A to 32 A rating |
| 177 | 40 A rating |
| 178 | 50/63 A rating |
| 179 | 80 A rating |
| 180 | 100 A rating |
| 181 | Four pole MCB (With B / C curve tripping characteristics) |
| 182 | 40 A rating |
| 183 | 50/63 A rating |
| 184 | 80 A rating |
| 185 | 100 A rating |
| 186 | Triple pole MCB (With D curve tripping Characteristics) |
| 187 | 6 A to 32 A rating |
| 188 | 40 A rating |
| 189 | 50/63 A rating |
| 190 | Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. |
| 191 | Two pole 30 mA sensitivity |
| 192 | 6A-32 A rating |
| 193 | 40 A rating |
| 194 | 63 A rating |
| 195 | Two pole 100/300mA sensitivity |
| 196 | 6A-32 A rating |
| 197 | 40 A rating |
| 198 | 63 A rating |
| 199 | Four pole 30 mA sensitivity |
| 200 | 6A-32 A rating |
| 201 | 40 A rating |
| 202 | 63 A rating |
| 203 | Four pole 100/300 mA sensitivity |
| 204 | 6A-32 A rating |
| 205 | 40 A rating |
| 206 | 63 A rating |
| 207 | P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required. |
| 208 | Double Pole |
| 209 | 25 Amp, 2 Module |
| 210 | 40 Amp, 2 Module |
| 211 | 63 Amp,3 Module |
| 212 | FourPole |
| 213 | 40 Amp, 4 Module |
| 214 | 63 Amp, 6 Module |
| 215 | Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 25 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. |
| 216 | Two pole 30 mA sensitivity |
| 217 | 16/25 A rating |
| 218 | 32/40 A rating |
| 219 | 63A rating |
| 220 | 100 A rating |
| 221 | Two pole 100/300mA sensitivity |
| 222 | 16/25 A rating |
| 223 | 40 A rating |
| 224 | 63 A rating |
| 225 | Four pole 30 mA sensitivity |
| 226 | 25 A rating |
| 227 | 40 A rating |
| 228 | 63 A rating |
| 229 | 100 A rating |
| 230 | Four pole 100/300 mA sensitivity |
| 231 | 25 A rating |
| 232 | 40 A rating |
| 233 | 63 A rating |
| 234 | 100 A rating |
| 235 | Providing & Fixing of din rail mounting surge protection device confirming to IEC 61643-11 for Type 1 + 2 protection and Maximum discharge current 50 kA with following configuration in existing distribution board / sheet including making connections, testing etc. as required. |
| 236 | 1P + N |
| 237 | 3P + N |
| 238 | Providing & Fixing of din rail mounting LED Indicating Lights with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required. |
| 239 | Red / Yellow / Blue / Green |
| 240 | Red-yellow-Blue |
| 241 | Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. |
| 242 | Suitable for Two / Three / Four module for MCB |
| 243 | Suitable for Six / Eight module for MCB/ RCCB |
| 244 | Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 245 | Metal door (single phase) IK-09 and IP-43 with Metal end box |
| 246 | 4 Way |
| 247 | 6 Way |
| 248 | 8 Way |
| 249 | 12 Way |
| 250 | 16 Way |
| 251 | Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box |
| 252 | 4 Way |
| 253 | 6 Way |
| 254 | 8 Way |
| 255 | 12 Way |
| 256 | 16 Way |
| 257 | Metal door (Three phase) IK-09 and IP-43 with Metal end box |
| 258 | 4 Way (8 incomer + 12 Outgoing) |
| 259 | 6 Way (8 incomer + 18 Outgoing) |
| 260 | 8 Way (8 incomer + 24 Outgoing) |
| 261 | 12 Way (8 incomer + 36 Outgoing) |
| 262 | Glazed / Acrylic door (Three phase) IK-09 and IP-43 with Metal end box |
| 263 | 4 Way (8 incomer + 12 Outgoing) |
| 264 | 6 Way (8 incomer + 18 Outgoing) |
| 265 | 8 Way (8 incomer + 24 Outgoing) |
| 266 | 12 Way (8 incomer + 36 Outgoing) |
| 267 | Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box |
| 268 | 4Way {8 Incomer + 6 Sub Incomer (2+2+2) + 12 out going } |
| 269 | 6Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going } |
| 270 | 8Way. {8 Incomer + 6 Sub Incomer (2+2+2) + 24 out going } |
| 271 | 12 Way {8 Incomer + 6 Sub Incomer (2+2+2) + 36 out going } |
| 272 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required. |
| 273 | 20 amp, (2P + E), 1 Module |
| 274 | 20 amp, (2P + E), 2 Module |
| 275 | 20 amp, (2P + E), 3 Module |
| 276 | 32 amp, (3P + E), 3 Module |
| 277 | 32 amp, (3P + N + E) 8 Module (with Polyamide Plug & Socket) |
| 278 | 63 amp, (3P + N+ E), 8 Module (with Polyamide Plug & Socket) |
| 279 | P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd. |
| 280 | IP -67, IK - 09 Panel mounted socket |
| 281 | 16 A (2P+E) |
| 282 | 32 A (2P+E) |
| 283 | 32 A (3P+N+E) |
| 284 | 63 A (3P+N+E) |
| 285 | IP -67, IK-09 Surface/Wall mounted socket |
| 286 | 16 A (2P+E) |
| 287 | 32 A (2P+E) |
| 288 | 32 A (3P+N+E) |
| 289 | 63 A (3P+N+E) |
| 290 | IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB |
| 291 | 16 A (2P+E) 250 V |
| 292 | 32 A (2P+E), 250 V |
| 293 | 32 A (3P+E), 415 V |
| 294 | 32 A (3P+N +E), 415 V |
| 295 | 63 A (3P+N +E), 415 V |
| 296 | IP - 67 Plug top |
| 297 | 16 A (2P+E) |
| 298 | 32 A (2P+E) |
| 299 | 32 A (3P+E) |
| 300 | 32 A (3P+N+E) |
| 301 | 63 A (3P+N+E) |
| 302 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 303 | Double door IK-09 & IP-43 with Metal end box |
| 304 | 4 Way (8 Incomer +12 Outgoing) |
| 305 | 6 Way (8 Incomer +18 Outgoing) |
| 306 | 8 Way (8 Incomer +24 Outgoing) |
| 307 | 12 Way (8 Incomer + 36 Outgoing) |
| 308 | Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. |
| 309 | Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box |
| 310 | 4 Way |
| 311 | 6 Way |
| 312 | 8 Way |
| 313 | 12 Way |
| 314 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box |
| 315 | 4 Way |
| 316 | 6 Way |
| 317 | 8 Way |
| 318 | 12 Way |
| 319 | Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box |
| 320 | 4 Way |
| 321 | 6 Way |
| 322 | 8 Way |
| 323 | 12 Way |
| 324 | P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size. |
| 325 | 3/4 module |
| 326 | 6 module |
| 327 | 8 module |
| 328 | 1 row 12 module |
| 329 | 2 row 24 module |
| 330 | 3 row 36 module |
| 331 | P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 332 | P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 333 | Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 334 | Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required. |
| 335 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 336 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 337 | Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required. |
| 338 | Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required. |
| 339 | Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 340 | Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 341 | Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required. |
| 342 | Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 343 | Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required. |
| 344 | Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 345 | Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required. |
| 346 | Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required. |
| 347 | Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required. |
| 348 | Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required. |
| 349 | Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required. |
| 350 | Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required. |
| 351 | P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required. |
| 352 | Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required. |
| 353 | Providing & Fixing of Non Modular Neon Light including making connection testing etc. as required. |
| 354 | Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required. |
| 355 | Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required. |
| 356 | Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required. |
| 357 | 6 A one way switch |
| 358 | 6 A two way switch |
| 359 | 6 A bell push |
| 360 | 10 A one way switch |
| 361 | 10 A two way switch |
| 362 | 16 A one way switch 1M |
| 363 | 20 A one way switch 1M |
| 364 | 20 A one way switch 2M |
| 365 | 16 Amp. 2 Module switch With Led Indicator |
| 366 | 32 Amp. 2 Module switch With Led Indicator |
| 367 | Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 368 | 6 A 3 pin shuttered socket |
| 369 | 6/16 A shuttered socket |
| 370 | Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required. |
| 371 | 5 step fan regulator 2 Module |
| 372 | Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required. |
| 373 | 25 Amp. 2 Module Motor Starter with on / off Push button |
| 374 | Modular MCB 6 A to 32 A SP |
| 375 | Modular MCB 6 A to 32 A DP |
| 376 | Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 377 | 1/2 Module |
| 378 | 3 Module |
| 379 | 4 Module |
| 380 | 5 Module |
| 381 | 6 Module |
| 382 | 8 Module |
| 383 | 10 Module |
| 384 | 12 Module |
| 385 | 16/18 Module |
| 386 | Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. |
| 387 | 1/2 Module |
| 388 | 3 Module |
| 389 | 4 Module |
| 390 | 5 Module |
| 391 | 6 Module |
| 392 | 8 Module |
| 393 | 10 Module |
| 394 | 12 Module |
| 395 | 16/18 Module |
| 396 | Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required. |
| 397 | 1-2 Module |
| 398 | 3 Module |
| 399 | 4-5 Module |
| 400 | 6-8 Module |
| 401 | 10-12 Module |
| 402 | 16/18 Module |
| 403 | Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required. |
| 404 | 1-2 Module |
| 405 | 3 Module |
| 406 | 4/5 Module |
| 407 | 6 / 8 module |
| 408 | 10 / 12 module |
| 409 | 16/18 module |
| 410 | Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required. |
| 411 | Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate. |
| 412 | 80mm x 50mm |
| 413 | 100/105mm x 50mm |
| 414 | 150/160mm x 50mm |
| 415 | 195/200mm x 50mm |
| 416 | Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required. |
| 417 | Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. |
| 418 | P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required. |
| 419 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:- |
| 420 | (a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided |
| 421 | (b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. |
| 422 | [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) |
| 423 | (d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. |
| 424 | (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging. |
| 425 | (f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra ) |
| 426 | (g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. |
| 427 | (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted) |
| 428 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. |
| 429 | Electrolytic grade Aluminium bus bar 6010 grade |
| 430 | Providing & Fixing of IS: 1248(part-1) 2003 confirming Moving Iron panel meter, 90 degree Analog type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter of class 1.0 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 431 | Voltmeter ( 0 to 500V ) |
| 432 | Ammeter (Direct Reading / CT Operated) |
| 433 | Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. |
| 434 | Single Phase Ammeter |
| 435 | Single Phase Voltmeter |
| 436 | Three phase Ammeter with Inbuilt Selector Switch |
| 437 | Three phase Voltmeter with Inbuilt Selector Switch |
| 438 | Three phase KWH Meter |
| 439 | Three phase KWH Meter Dual Source |
| 440 | Frequency Meter |
| 441 | Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter |
| 442 | Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter |
| 443 | Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter |
| 444 | Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . |
| 445 | Ring type tape wound CT |
| 446 | C T Class 1, Ratio up to 150/5, Burden 5 VA |
| 447 | C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA |
| 448 | C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA |
| 449 | C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA |
| 450 | Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 451 | Voltage Between Phases with OFF ( 4 Position ) |
| 452 | Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position ) |
| 453 | Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required . |
| 454 | Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required . |
| 455 | Providing & Fixing of 25 A TNC ( Trip - neutal - close ) switch to control remotely on existing panel as required. |
| 456 | Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. |
| 457 | Red/yellow/Green colour |
| 458 | Blue / white Colour |
| 459 | Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required. |
| 460 | Non luminous type |
| 461 | Luminous type Red , Yellow, Green, Amber |
| 462 | Luminous type Blue , white |
| 463 | Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required. |
| 464 | 3.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms) |
| 465 | 11 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms) |
| 466 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. |
| 467 | 3 pole Power contactors with following AC 3 Rating |
| 468 | Up to 12 Amp |
| 469 | 16 to 25 Amp |
| 470 | 32 Amp. |
| 471 | 40 Amp |
| 472 | 50 Amp |
| 473 | 70 Amp |
| 474 | 80 Amp |
| 475 | 95 Amp |
| 476 | 140 Amp |
| 477 | 185 Amp |
| 478 | 250 Amp |
| 479 | 300 Amp |
| 480 | 400 Amp |
| 481 | 4 pole Power contactors with following AC 1 Rating |
| 482 | 16 Amp. |
| 483 | 25/32 Amp. |
| 484 | 40 Amp |
| 485 | 50/55 Amp |
| 486 | 63 Amp |
| 487 | 100/105 Amp |
| 488 | 160 Amp |
| 489 | 200 Amp |
| 490 | 250 Amp |
| 491 | 325 Amp |
| 492 | 400 Amp |
| 493 | 500 Amp |
| 494 | 600 Amp |
| 495 | 900 Amp |
| 496 | P & F of Control relays (Auxiliary Contactor) for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required. |
| 497 | P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required. |
| 498 | Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required. |
| 499 | Up to 14 Amp |
| 500 | 14 to 23 Amp |
| 501 | 20 to 33 Amp |
| 502 | 24 to 40 Amp |
| 503 | 36 to 60 Amp |
| 504 | 45 to 75 Amp |
| 505 | 66 to 110 Amp |
| 506 | P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required. |
| 507 | Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. |
| 508 | One day reserve (Electromechanical type ) |
| 509 | One day & week reserve (digital type ) |
| 510 | Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required. |
| 511 | Providing & Fixing of IP54 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) , having resolution 0.1 / 0.01 kwh , confirming to IS:13779/ IS:15959, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required. |
| 512 | up to 30 ampere single phase meter acc. Cl 1 |
| 513 | 10 A to 60 ampere Single phase meter acc. Cl 1 |
| 514 | 3ph, 4W KWh CT Operated Base mounting 240 V-/5A acc. Cl 0.5s |
| 515 | 3ph, 4W KWh Direct Base mounting 240 V 10-60 Amp acc. Cl 1 |
| 516 | P & F of Automatic Transfer Switch (ATS) confirming to IEC60947-6-1, Utilization cateogory AC-33B with OEM fabricated enclosure for automatic on load transfer between two source power supply of 415V through Solenoid/Motorised mechanism and integrated with three positions realize fast transfer within 180 ms (for solenoid) and within 2.6 sec.(for motorised). ATS shall have three postions (S1-OFF-S2) , Manual / Auto Override feature, The two sources can be isolated in the off position with a padlock. capability to expand with RS 485 communication module, which can ensure real-time transmission of communication data. ATS shall have automatic generator start & stop control function; Auxillary contacts to indicate mechanical positions. Minimum Electrical operations 6000, of following Current ratings, including making connections etc. as required. |
| 517 | 63 Amps |
| 518 | 125 Amps |
| 519 | 160 Amps |
| 520 | 200 Amps |
| 521 | 250 Amps |
| 522 | 315 Amps |
| 523 | 400 Amps |
| 524 | 630 Amps |
| 525 | 800 Amps |
| 526 | P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required. |
| 527 | Direct on line (DOL) Starter with following Motor rating |
| 528 | Motor rating 0.55 KW |
| 529 | Motor rating 0.75 KW |
| 530 | Motor rating 1.5 KW |
| 531 | Motor rating 2.2 KW |
| 532 | Motor rating 4.0 KW |
| 533 | Motor rating 5.5 KW |
| 534 | Motor rating 7.5 KW |
| 535 | Motor rating 9.0 KW |
| 536 | Star - Delta Starter with following Motor rating |
| 537 | Motor rating 4.0 KW |
| 538 | Motor rating 5.5 KW |
| 539 | Motor rating 7.5 KW |
| 540 | Motor rating 9.0 KW |
| 541 | Motor rating 11.0 KW |
| 542 | Motor rating 15.0 KW |
| 543 | Motor rating 18.5 KW |
| 544 | SITC of Microprocessor based Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440/415 V, 50 Hz and having adjustable over load, short-circuit, Instantaneous, earth fault (LSIG) with separate LED indication or Fault details on display for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, Inbuilt ZSI, Current metering, Provision for Communication, Thermal memory, trip free mechanism, modular design and suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , pollution degree 3, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 30 ms. Provision for electrical & mechanical interlock between ACB sand other required accessories (Cost of accessories to be paid extra) Min.electrical operation 10000 upto 1600 A rating and 5000 for 2000 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 545 | Manual spring charged type 4 Pole |
| 546 | 630/800 A Rating , 50 kA |
| 547 | 1000 A Rating , 50 kA |
| 548 | 1250 A Rating ,50 kA |
| 549 | Supply and fixing of following accessories for Air circuit breaker (ACB) in existing ACB including making connection etc complete in all respect. |
| 550 | Mechanical Interlocking Kit using key & Lock |
| 551 | Closing Release |
| 552 | Shunt Trip Release |
| 553 | Under voltage Release |
| 554 | External Neutral CT cast resin |
| 555 | Microswitch for Indication |
| 556 | Operation Counter |
| 557 | Door Interlock |
| 558 | Auxiliary Contact 4 NO + 4 NC |
| 559 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate. |
| 560 | 3 pole MCCB With Thermal Magnetic release |
| 561 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 562 | 125 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 563 | 160 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 564 | 200 Amp , 25 kA, adjustable O/L & fixed S/C setting, |
| 565 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 566 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 567 | 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 568 | 4 pole MCCB With Thermal Magnetic release |
| 569 | up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 570 | 125 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 571 | 160 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 572 | 200 Amp , 25 kA, adjustable O/L & Fixed S/C setting, |
| 573 | 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 574 | 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, |
| 575 | 630 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 576 | 800 Amp , 50 kA, adjustable O/L & adjustable S/C setting, |
| 577 | 4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection. |
| 578 | Upto 160 Amp , 50 kA |
| 579 | 250 Amp , 50 kA |
| 580 | 400 Amp , 50 kA |
| 581 | 630 Amp, 50 kA |
| 582 | 800 Amp , 50 kA |
| 583 | Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. |
| 584 | Shunt Trip Release |
| 585 | Under Voltage Release |
| 586 | Extended Rotary Handle |
| 587 | Direct Rotary Handle |
| 588 | Mechanical Interlocking kit |
| 589 | Motor mechanism for 250A MCCB (240V, 50Hz) |
| 590 | Motor mechanism for 400A MCCB (240V, 50Hz) |
| 591 | Motor mechanism for 630A MCCB (240V, 50Hz) |
| 592 | Auxiliary contact |
| 593 | Trip Alarm contact |
| 594 | Auxiliary + Trip alarm contact |
| 595 | Spreaders upto 125A, 3 Pole MCCB |
| 596 | Spreaders for 160A, 3 Pole MCCB |
| 597 | Spreaders for 160A, 4 Pole MCCB |
| 598 | Spreaders for 250A, 3 Pole MCCB |
| 599 | Spreaders for 250A, 4 Pole MCCB |
| 600 | Spreaders for 400A, 3Pole MCCB |
| 601 | Spreaders for 400A, 4Pole MCCB |
| 602 | Spreaders for 630A, 3Pole MCCB |
| 603 | Spreaders for 630A, 4Pole MCCB |
| 604 | Spreaders for 800A, 3Pole MCCB |
| 605 | Spreaders for 800A, 4Pole MCCB |
| 606 | Phase Barriers up to 630A, 3/4Pole MCCB |
| 607 | External Neutral CT with Adaptor Kit |
| 608 | Current Metering Module |
| 609 | Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosure suitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations, detachable gland plate, including making connections, testing etc. as required. |
| 610 | Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable |
| 611 | Suitable to accommodate above 70 sqmm 3.5 core Al arm. Cable to 185 Sqm , 3.5 core Al Arm. Cable |
| 612 | SITC of IP-43 surface mounting heavy duty modular Sub main Distribution board (SMDB) fabricated by MCCB OEM in his own factory having short circuit withstand current 35 kA (upto 400 amp.Incomer ) and 50 kA for 630 amp. Incomer with suitable bottom cabling box, 4 no. corner boxes, 2 no. side cabling boxes, metering Extension box with provision of incomer suitable for 3/4 pole MCCB and 3/4 pole MCCB as outgoing, Ammeter, Voltmeter, Indicating lamp, made out from Galvanized steel / CRCA sheet of 1.2/1.6 mm thick conforming to IEC 61439 Part 1 & 2. , U imp 8 KV, form of separation 2b, powder painted complete with insulated suitable rating tinned copper bus bar, neutral bars with shrouds, earth bar , din bar, making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. (Without MCCB, ammeter, voltmeter, selector switch , Indicating lamp) |
| 613 | SMDB with 250 Amp. Incoming and 4 no. 100 Amps Outgoing |
| 614 | SMDB with 250 Amp. Incoming and 8 no. 100 Amps Outgoing |
| 615 | SMDB with 250 Amp. Incoming and 12 no. 100 Amps Outgoing |
| 616 | SMDB with 400 Amp. Incoming and 4 no. 100 Amps Outgoing |
| 617 | SMDB with 400 Amp. Incoming and 8 no. 100 Amps Outgoing |
| 618 | Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating. |
| 619 | Open execution type |
| 620 | 125 A |
| 621 | 160 A |
| 622 | 200 A |
| 623 | 250 A |
| 624 | 320 A |
| 625 | 400 A |
| 626 | 630 A |
| 627 | 800 A |
| 628 | 1000 A |
| 629 | With OEM fabricated sheet steel enclosure, powder coated, door locking system allow opening of door in OFF position only with 2 nos external earthing points. |
| 630 | 125 A |
| 631 | 160 A |
| 632 | 200 A |
| 633 | 250 A |
| 634 | 320 A |
| 635 | 400 A |
| 636 | 630 A |
| 637 | 800 A |
| 638 | 1000 A |
| 639 | Providing & Fixing of Four Pole By pass Change Over Switch confirming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings. |
| 640 | 100 A |
| 641 | 200 A |
| 642 | 320 A |
| 643 | 400 A |
| 644 | 630 A |
| 645 | 800 A |
| 646 | 1000 A |
| 647 | Providing & Fixing of bus bar chamber housed in sheet metal box Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required. |
| 648 | 300 mm long , 4 strip |
| 649 | 450 mm long , 4 strip |
| 650 | 600 mm long , 4 strip |
| 651 | 900 mm long , 4 strip |
| 652 | Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size. |
| 653 | 6.0 Sq. mm |
| 654 | 2 core |
| 655 | 3 core |
| 656 | 4 core |
| 657 | 10.0 Sq. mm |
| 658 | 2 core |
| 659 | 3 core |
| 660 | 4 core |
| 661 | 16.0 Sq. mm |
| 662 | 3 core |
| 663 | 4 core |
| 664 | 25.0 Sq. mm |
| 665 | 3.5 core |
| 666 | 35.0 Sq. mm |
| 667 | 3.5 core |
| 668 | 50.0 Sq. mm |
| 669 | 3.5 core |
| 670 | 70.0 Sq. mm |
| 671 | 1 core |
| 672 | 3 core |
| 673 | 3.5 core |
| 674 | 95.0 Sq. mm |
| 675 | 1 core |
| 676 | 3.5 core |
| 677 | 120.0 Sq. mm |
| 678 | 1 core |
| 679 | 3.5 core |
| 680 | 150.0 Sq. mm |
| 681 | 1 core |
| 682 | 3.5 core |
| 683 | 185.0 Sq. mm |
| 684 | 1 core |
| 685 | 3.5 core |
| 686 | 240.0 Sq. mm |
| 687 | 1 core |
| 688 | 3.5 core |
| 689 | 300.0 Sq. mm |
| 690 | 1 core |
| 691 | 3.5 core |
| 692 | 400.0 Sq. mm |
| 693 | 1 core |
| 694 | 3.5 core |
| 695 | 500.0 Sq. mm |
| 696 | 1 core |
| 697 | 3.5 core |
| 698 | Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth. |
| 699 | Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 700 | Excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 100 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically (Longest side is vertical to cable) along the cable , (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 701 | Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 702 | Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 703 | Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 704 | Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 705 | Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 706 | Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps. |
| 707 | Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 708 | Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 709 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required. |
| 710 | 2 x 4.0 sq.mm |
| 711 | 2 x 6.0 sq.mm |
| 712 | 2 x 10.0 sq.mm |
| 713 | 2 x 16.0 sq.mm |
| 714 | 2 x 25.0 sq.mm |
| 715 | 2 x 35.0 sq.mm |
| 716 | 2 x 50.0 sq.mm |
| 717 | 2 x 70.0 sq.mm |
| 718 | 3 x 4.0 sq.mm |
| 719 | 3 x 6.0 sq.mm |
| 720 | 3 x 10.0 sq.mm |
| 721 | 3 x 16.0 sq.mm |
| 722 | 3 x 25.0 sq.mm |
| 723 | 3 x 35.0 sq.mm |
| 724 | 3 x 50.0 sq.mm |
| 725 | 3 x 70.0 sq.mm |
| 726 | 3.5 x 25.0 sq.mm |
| 727 | 3.5 x 35.0 sq.mm |
| 728 | 3.5 x 50.0 sq.mm |
| 729 | 3.5 x 70.0 sq.mm |
| 730 | 3.5 x 95.0 sq.mm |
| 731 | 3.5 x 120.0 sq.mm |
| 732 | 3.5 x 150.0 sq.mm |
| 733 | 3.5 x 185.0 sq.mm |
| 734 | 3.5 x 240.0 sq.mm |
| 735 | 3.5 x 300.0 sq.mm |
| 736 | 3.5 x 400.0 sq.mm |
| 737 | 3.5 x 500.0 sq.mm |
| 738 | 3.5 x 630.0 sq.mm |
| 739 | 4 x 4.0 sq.mm |
| 740 | 4 x 6.0 sq.mm |
| 741 | 4 x 10.0 sq.mm |
| 742 | 4 x 16.0 sq.mm |
| 743 | 1 x 70.0 sq.mm |
| 744 | 1 x 95.0 sq.mm |
| 745 | 1 x 120.0 sq.mm |
| 746 | 1 x 150.0 sq.mm |
| 747 | 1 x 185.0 sq.mm |
| 748 | 1 x 240.0 sq.mm |
| 749 | 1 x 300.0 sq.mm |
| 750 | 1 x 400.0 sq.mm |
| 751 | 1 x 500.0 sq.mm |
| 752 | 1 x 630.0 sq.mm |
| 753 | 1 x 800.0 sq.mm |
| 754 | 1 x 1000.0 sq.mm |
| 755 | Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required. |
| 756 | 1 x 16.0 sq.mm |
| 757 | 1 x 25.0 sq.mm |
| 758 | 1 x 35.0 sq.mm |
| 759 | 1 x 50.0 sq.mm |
| 760 | 1 x 70.0 sq.mm |
| 761 | 1 x 95.0 sq.mm |
| 762 | 1 x 120.0 sq.mm |
| 763 | 2 x 4.0 sq.mm |
| 764 | 2 x 6.0 sq.mm |
| 765 | 2 x 10.0 sq.mm |
| 766 | 2 x 16.0 sq.mm |
| 767 | 2 x 25.0 sq.mm |
| 768 | 2 x 35.0 sq.mm |
| 769 | 2 x 50.0 sq.mm |
| 770 | 2 x 70.0 sq.mm |
| 771 | 2 x 95.0 sq.mm |
| 772 | 2 x 120.0 sq.mm |
| 773 | 3 x 1.5 sq.mm |
| 774 | 3 x 2.5 sq.mm |
| 775 | 3 x 4.0 sq.mm |
| 776 | 3 x 6.0 sq.mm |
| 777 | 3 x 10.0 sq.mm |
| 778 | 3 x 16.0 sq.mm |
| 779 | 3 x 25.0 sq.mm |
| 780 | 3 x 35.0 sq.mm |
| 781 | 3 x 50.0 sq.mm |
| 782 | 3 x 70.0 sq.mm |
| 783 | 3 x 95.0 sq.mm |
| 784 | 3 x 120.0 sq.mm |
| 785 | 4 x 1.5 sq.mm |
| 786 | 4 x 2.5 sq.mm |
| 787 | 4 x 4.0 sq.mm |
| 788 | 4 x 6.0 sq.mm |
| 789 | 4 x 10.0 sq.mm |
| 790 | 4 x 16.0 sq.mm |
| 791 | 4 x 25.0 sq.mm |
| 792 | 4 x 35.0 sq.mm |
| 793 | 4 x 50.0 sq.mm |
| 794 | 4 x 70.0 sq.mm |
| 795 | 4 x 95.0 sq.mm |
| 796 | 4 x 120.0 sq.mm |
| 797 | 6 x 1.5 sq.mm |
| 798 | 6 x 2.5 sq.mm |
| 799 | 8 x 1.5 sq.mm |
| 800 | 8 x 2.5 sq.mm |
| 801 | 10 x 1.5 sq.mm |
| 802 | 10 x 2.5 sq.mm |
| 803 | 12 x 1.5 sq.mm |
| 804 | 12 x 2.5 sq.mm |
| 805 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size. |
| 806 | 1.5 Sq.mm |
| 807 | 2.5 Sq.mm |
| 808 | 4.0 Sq.mm |
| 809 | 6.0 Sq.mm |
| 810 | 10.0 Sq.mm |
| 811 | 16.0 Sq.mm |
| 812 | 25.0 Sq.mm |
| 813 | 35.0 Sq.mm |
| 814 | 50.0 Sq.mm |
| 815 | 70.0 Sq.mm |
| 816 | 95.0 Sq.mm |
| 817 | 120.0 Sq.mm |
| 818 | 150.0 Sq.mm |
| 819 | 185.0 Sq.mm |
| 820 | 240.0 Sq.mm |
| 821 | 300.0 Sq.mm |
| 822 | 400.0 Sq.mm |
| 823 | 500.0 Sq.mm |
| 824 | 630.0 Sq.mm |
| 825 | 800.0 Sq.mm |
| 826 | 1000.0 Sq.mm |
| 827 | Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size. |
| 828 | 1.5 Sq.mm |
| 829 | 2.5 Sq.mm |
| 830 | 4.0 Sq.mm |
| 831 | 6.0 Sq.mm |
| 832 | 10.0 Sq.mm |
| 833 | 16.0 Sq.mm |
| 834 | 25.0 Sq.mm |
| 835 | 35.0 Sq.mm |
| 836 | 50.0 Sq.mm |
| 837 | 70.0 Sq.mm |
| 838 | 95.0 Sq.mm |
| 839 | 120.0 Sq.mm |
| 840 | Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required. |
| 841 | 100mm x 50mm x 1.6mm |
| 842 | 150mm x 50mm x 1.6mm |
| 843 | 225mm x 50mm x 1.6mm |
| 844 | 300mm x 50mm x 1.6mm |
| 845 | 375mm x 50mm x 2.0mm |
| 846 | 450mm x 50mm x 2.0mm |
| 847 | 600mm x 50mm x 2.0mm |
| 848 | 300mm x 62.5mm x 2.0mm |
| 849 | 375mm x 62.5mm x 2.0mm |
| 850 | 450mm x 62.5mm x 2.0mm |
| 851 | 600mm x 62.5mm x 2.0mm |
| 852 | 750mm x 62.5mm x 2.0mm |
| 853 | 600mm x 75mm x 2.0mm |
| 854 | Supply, Fabricating & installing following sizes of Hot dipped Galvanized iron Ladder type cable tray ( Galvanized thickness not less then 50 microns) with rungs at span of 250mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with M.S. suspenders etc. as required. |
| 855 | 100mm x 50mm x 1.6mm |
| 856 | 150mm x 50mm x 1.6mm |
| 857 | 225mm x 50mm x 1.6mm |
| 858 | 300mm x 50mm x 1.6mm |
| 859 | 375mm x 50mm x 2.0mm |
| 860 | 450mm x 50mm x 2.0mm |
| 861 | 600mm x 50mm x 2.0mm |
| 862 | 300mm x 62.5mm x 2.0mm |
| 863 | 375mm x 62.5mm x 2.0mm |
| 864 | 450mm x 62.5mm x 2.0mm |
| 865 | 600mm x 62.5mm x 2.0mm |
| 866 | 750mm x 62.5mm x 2.0mm |
| 867 | 600mm x 75mm x 2.0mm |
| 868 | 750mm x 75mm x 2.0mm |
| 869 | Supplying and fixing of CE certified and UL listed GI wire mesh cable tray made from spot welded steel wire hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods, etc. as required of following sizes. |
| 870 | 100 mm x 50 mm x 3.5 - 5.9 mm |
| 871 | 150 mm x 50 mm x 3.5 - 5.9 mm |
| 872 | 200 mm x 50 mm x 3.5 - 5.9 mm |
| 873 | 300 mm x 50 mm x 3.5 - 5.9 mm |
| 874 | 400 mm x 50 mm x 3.5 - 5.9 mm |
| 875 | 500 mm x 50 mm x 3.5 - 5.9 mm |
| 876 | 100 mm x 100 mm x 3.5 - 5.9 mm |
| 877 | 150 mm x 100 mm x 3.5 - 5.9 mm |
| 878 | 200 mm x 100 mm x 3.5 - 5.9 mm |
| 879 | 300 mm x 100 mm x 3.5 - 5.9 mm |
| 880 | 400 mm x 100 mm x 3.5 - 5.9 mm |
| 881 | 500 mm x 100 mm x 3.5 - 5.9 mm |
| 882 | S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required. |
| 883 | 1 x 25 sq.mm-50 sq.mm |
| 884 | 1 x 70 sq.mm-150 sq.mm |
| 885 | 1 x 185 sq.mm-300 sq.mm |
| 886 | 1 x 400 sq.mm |
| 887 | 1 x 500 sq.mm |
| 888 | 3/3.5/4 x 1.5 sq.mm-6 sq.mm |
| 889 | 3/3.5/4 x 10.0-16.0 sq.mm |
| 890 | 3/3.5/4 x 25.0 sq.mm-50 sq.mm |
| 891 | 3/3.5/4 x 70.0 sq.mm-150 sq.mm |
| 892 | 3/3.5/4 x 185.0 sq.mm-300 sq.mm |
| 893 | 3/3.5/4 x 400 sq.mm |
| 894 | 3/3.5/4 x500 sq.mm |
| 895 | S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required |
| 896 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). |
| 897 | 50 mm |
| 898 | 63 mm |
| 899 | 75 mm |
| 900 | 90 mm |
| 901 | 110 mm |
| 902 | 120 mm |
| 903 | 160 mm |
| 904 | 200 mm |
| 905 | Providing and laying Non Pressure NP-3 class R.C.C. pipes confirming to IS:458 including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). |
| 906 | 200 mm Dia. |
| 907 | 250 mm dia. |
| 908 | 300 mm dia |
| 909 | 450 mm dia. |
| 910 | Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 911 | Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required. |
| 912 | SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :- |
| 913 | (a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole |
| 914 | (b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7 |
| 915 | © Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt |
| 916 | (d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. |
| 917 | (e) Testing of earth resistance for value of 5 ohms or less as required. |
| 918 | (f) Test certificates for confirming above standards from OEM is mandatory. |
| 919 | 17.2 mm thick and 3 Mtr. Long |
| 920 | 25 mm thick and 3 Mtr. Long |
| 921 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. |
| 922 | 20mm x 3mm copper strip |
| 923 | 25mm x 3mm copper strip |
| 924 | 25mm x 5mm copper strip |
| 925 | 20mm x 3mm tinned copper strip |
| 926 | 25mm x 3mm tinned copper strip |
| 927 | 25mm x 5mm tinned copper strip |
| 928 | 20mm x 3mm G.I. ( Hot Dipped ) Strip |
| 929 | 25mm x 3mm G.I. ( Hot Dipped ) Strip |
| 930 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 931 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. |
| 932 | 6 SWG tinned copper Wire |
| 933 | 8 SWG tinned copper Wire |
| 934 | 10 SWG tinned copper. Wire |
| 935 | 6 SWG copper Wire |
| 936 | 8 SWG copper Wire |
| 937 | 10 SWG copper. Wire |
| 938 | 6 SWG G.I. ( Hot Dipped ) Wire |
| 939 | 8 SWG G.I. ( Hot Dipped ) Wire |
| 940 | 10 SWG G.I. ( Hot Dipped ) Wire |
| 941 | 16 Sq.mm Copper coated steel stranded conductor (Wt. 130 Kg/Km) |
| 942 | 25 Sq.mm Copper coated steel stranded conductor ( Wt. 200Kg/Km) |
| 943 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra) |
| 944 | 15 mm dia. |
| 945 | 20 mm dia. |
| 946 | 25 mm dia. |
| 947 | 32mm dia |
| 948 | 40 mm dia. |
| 949 | 50 mm dia. |
| 950 | 65 mm dia. |
| 951 | 80 mm dia. |
| 952 | 100 mm dia. |
| 953 | 150 mm dia. |
| 954 | Supply and installation of an 8 mm aluminum down conductor, designed for efficient dissipation of lightning currents. The conductor shall be securely fixed using corrosion-resistant clamps at appropriate intervals, ensuring a continuous, low-resistance path from the air terminal to the earthing system. The conductor length shall be determined based on actual site conditions, with all necessary accessories, including clamps, connectors, and fasteners. |
| 955 | Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. |
| 956 | Up to 457 mm size |
| 957 | more than 457 mm & up to 610 mm |
| 958 | Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required. |
| 959 | Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. as required. |
| 960 | With regulator |
| 961 | Without regulator |
| 962 | Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. |
| 963 | 1200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20 |
| 964 | 1400 mm sweep with Air delivery >/= 270 CMM and Service Value 7.70 |
| 965 | Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required. |
| 966 | 150 mm sweep with Min. Air delivery 350 Cubic meter/Hr, 2000 RPM |
| 967 | 200 mm sweep with Min. Air delivery 800 Cubic meter/Hr, 1600 RPM |
| 968 | 250 mm sweep with Min. Air delivery 1150 Cubic meter/Hr, 1300 RPM |
| 969 | Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) |
| 970 | Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM |
| 971 | Pedestal Type having Adjustable Height with Service value 2.6 CMM /W, Min. Air Delivery 85 CMM |
| 972 | Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required. |
| 973 | 1200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 974 | 1400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 ) |
| 975 | Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required. |
| 976 | Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required. |
| 977 | P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required. |
| 978 | P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side as required. |
| 979 | Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required. |
| 980 | 230 mm sweep, Minimum air delivery 750 Cum / hour |
| 981 | 300 mm sweep Minimum air delivery 1600 Cum / hour |
| 982 | Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required. |
| 983 | 300 mm sweep(900 RPM) |
| 984 | 380 mm sweep(900 RPM) |
| 985 | 450 mm sweep(1400 RPM) |
| 986 | 600 mm sweep(900 RPM) |
| 987 | Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. |
| 988 | 150 mm sweep Minimum Air Delivery 150 Cum / hour |
| 989 | 200 mm sweep Minimum Air Delivery 450 Cum / hour |
| 990 | 250 mm sweep Minimum Air Delivery 750 Cum / hour |
| 991 | Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required. |
| 992 | 450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 993 | 450 mm sweep Pedestal type and three speed regulator with Minimum Air Delivery 150 Cum. / Minute |
| 994 | 600 mm sweep Wall mounting with Minimum Air Delivery 270 Cum. / Minute |
| 995 | Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required. |
| 996 | Wall mounting type with Adjustable Vertical Angle |
| 997 | Pedestal Type with Adjustable Height |
| 998 | Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required. |
| 999 | Numbering of ceiling fans/ fixtures with approved enamel paint etc as required. |
| 1000 | P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required. |
| 1001 | Up to 380 mm size |
| 1002 | above 380 mm size |
| 1003 | P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required. |
| 1004 | Suitable for 300 mm sweep Exhaust Fan |
| 1005 | Suitable for 380 mm sweep Exhaust Fan |
| 1006 | Suitable for 450 mm sweep Exhaust Fan |
| 1007 | S & F Extruded Aluminium Fresh Air / External Weather Louver, Small Format type with 38 mm flange width & 50 mm depth. finish - powder coated off white with aluminium mesh of required size. |
| 1008 | SITC of single phase 230 V, 50 Hz, Permanent Magnet synchronous motorised (PMSM) High volume low speed (HVLS) fan comprising of aviation grade extruded Alluminium alloy 6063-T grade aerofil 5/6 blade, Suitable Hanging bracket with extension tube for suitable clearance from blade to ceiling, Fastners, Nut bolts, PVC coated GI guy Wire rope, VFD control panel, sound level 45-50 dB, suitable cable from control panel to Fan motor of following sizes. |
| 1009 | 24' dia, floor to fan blade height 27-30 ft,. Area coverage 18500 sq.ft, air delivery 380000 cfm, 55 RPM |
| 1010 | Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required. |
| 1011 | 25 Ltr. |
| 1012 | 50 Ltr. |
| 1013 | Providing & Fixing of stem type ISI marked (IS 3017 / 85) snap action adjustable thermostat for storage water heater including making connection testing etc. complete in all respect. |
| 1014 | Providing & Fixing of stem type ISI marked (IS 3017 / 85) , snap action bipolar adjustable thermostat with built in auto thermal cut out for storage water heater including making connection testing etc. complete in all respect. |
| 1015 | Providing & Fixing 2 / 3 KW nickle plated, mineral filled heating element including making connection testing etc complete in all respect. |
| 1016 | Providing & Fixing of 2 / 3 KW Glass Line Coated , mineral filled heating element including making connection testing etc complete in all respect. |
| 1017 | Providing & Fixing of Multi safety valve of 8.5 bar capacity with built in drain, NRV, Vacuum release, Pressure release etc. as required complete in all respect. |
| 1018 | Providing & Fixing of Twin neon indicating lamp of superior quality for storage water heater complete in all respect. |
| 1019 | Providing & Fixing of 13 mm Brass with C.P. finished ISI marked angle valve for storage water heater as required complete in all respect. |
| 1020 | Providing & Fixing of heavy duty flexible alloy pipe for storage water heater for inlet and outlet of suitable length including the cost of nuts, washers etc complete in all respect. |
| 1021 | 450 mm |
| 1022 | 600 mm |
| 1023 | Charges for descaling of storage water heater including replacement of Multi Function Valve as required. |
| 1024 | Charges for Fixing of storage water heater including 10/12 mm Anchor fasteners of suitable size, testing, carrying from store to site,etc. as required. |
| 1025 | Providing & Fixing of 2.0 KW twin ceremic cartridge, Withstands temperatures up to 1000 C long lasting even in hard water including making connection testing etc complete in all respect. |
| 1026 | SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1027 | 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 1028 | SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1029 | Recessed Mounting |
| 1030 | Minimum lumen output 1950 lm |
| 1031 | Minimum lumen output 2400 lm |
| 1032 | Surface Mounting (with extruded alumn. Housing ) |
| 1033 | Minimum lumen output 1950 lm |
| 1034 | Minimum lumen output 2400 lm |
| 1035 | SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1036 | Recessed Mounting |
| 1037 | Minimum lumen output 4800 lm |
| 1038 | Surface Mounting (Driver should be Inside the Luminaire) |
| 1039 | Minimum lumen output 4800 lm |
| 1040 | SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1041 | Recessed Mounting |
| 1042 | Minimum lumen output 2880 lm |
| 1043 | Minimum lumen output 3600 lm |
| 1044 | Surface Mounting (Driver should be Inside the Luminaire) |
| 1045 | Minimum lumen output 2880 lm |
| 1046 | Minimum lumen output 3600 lm |
| 1047 | SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1048 | Recessed Mounting |
| 1049 | Minimum lumen output 4800 lm |
| 1050 | Surface Mounting (Driver should be Inside the Luminaire) |
| 1051 | Minimum lumen output 4800 lm |
| 1052 | SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required. |
| 1053 | 18/20 Watt |
| 1054 | Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith Polycarbonate enclosure having more than 200 No's Low Power LED's having minimum power consumption 15 watts complete in all respect. |
| 1055 | aviation obstruction LED light luminaire 12/15 Watts |
| 1056 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required. |
| 1057 | High Power LED Flood Light Minimum lumen outpu 3900 lm |
| 1058 | High Power LED Flood Light Minimum lumen output 6500 lm |
| 1059 | High Power LED Flood Light Minimum lumen output 10400 lm |
| 1060 | High Power LED Flood Light Minimum lumen output 13000 lm |
| 1061 | High Power LED Flood Light Minimum lumen output 15600 lm |
| 1062 | High Power LED Flood Light Minimum lumen output 65000 lm |
| 1063 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required. |
| 1064 | LED Street Light fixture with Minimum lumen output 5625 lm |
| 1065 | LED Street Light fixture with Minimum lumen output 7500 lm |
| 1066 | LED Street Light fixture with Minimum lumen output 8750 lm |
| 1067 | LED Street Light fixture with Minimum lumen output 11250 lm |
| 1068 | LED Street Light fixture with Minimum lumen output 12500 lm |
| 1069 | LED Street Light fixture with Minimum lumen output 26250 lm |
| 1070 | Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mm fabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 6 Amp MCB complete in all respect. |
| 1071 | Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. |
| 1072 | 125 mm X 200 mm X 122 mm |
| 1073 | 160 mm X 225 mm X 100 mm |
| 1074 | 200 mm X 200 mm X 122 mm |
| 1075 | 225 mm X 225 mm X 100 mm |
| 1076 | Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required. |
| 1077 | 20 mm Dia. |
| 1078 | 25 mm Dia. |
| 1079 | 32 mm Dia. |
| 1080 | 40 mm Dia. |
| 1081 | Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes. |
| 1082 | 180 x 180 x 91 mm |
| 1083 | 250 x 200 x 115 mm |
| 1084 | 300 x 450 x 132 mm |
| 1085 | 320 x 440 x 179 mm |
| 1086 | 320 x 640 x 179 mm |
| 1087 | S & F of 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years |
| 1088 | 7.0 AH |
| 1089 | 12 AH |
| 1090 | 18 AH |
| 1091 | 26 AH |
| 1092 | 28 AH |
| 1093 | 34 AH |
| 1094 | 42 AH |
| 1095 | 65 AH |
| 1096 | 100 AH |
| 1097 | 120 AH |
| 1098 | 150 AH |
| 1099 | Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect. |
| 1100 | Delowering and Lowering |
| 1101 | Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. |
| 1102 | for vertical installation |
| 1103 | 40 mm OD 6 kg / cm2 |
| 1104 | 50 mm OD 6 kg / cm2 |
| 1105 | 63 mm OD 6 kg / cm2 |
| 1106 | 75 mm OD 6 kg / cm2 |
| 1107 | 90 mm OD 10 kg / cm2 |
| 1108 | for Horizontal installation |
| 1109 | 40 mm OD 4kg/ cm2 |
| 1110 | 50 mm OD 4 kg/ cm2 |
| 1111 | 63 mm OD 4 kg/ cm2 |
| 1112 | 75 mm OD 4 kg/ cm2 |
| 1113 | 90 mm OD 6 kg/ cm2 |
| 1114 | SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal. The motor body of single phase pump shall be of SS and rest of all shall be of cast iron. Shaft of three phase pump shall be of SS 410 grade. All casting parts should be cathod electro deposition (CED) coated. Motor winding shall be 100% copper wire material. Dynamically balanced rotating parts to ensure min. vibration etc. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. |
| 1115 | 0.5 HP, 1-Ø, (7 -18) Mtr, (180 - 20) LPM |
| 1116 | 1.0 HP, 1-Ø, (12 -27) Mtr, (200- 30) LPM |
| 1117 | 1.5 HP, 1-Ø, (18 -33) Mtr, (160-35) LPM |
| 1118 | 2.0 HP, 1-Ø, (9 -21) Mtr, (475 - 130) LPM |
| 1119 | 3.0 HP, 3-Ø, (17 -27) Mtr, (680 - 250) LPM |
| 1120 | 5.0 HP, 3-Ø, (13 -36) Mtr, (995-200) LPM |
| 1121 | SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect. |
| 1122 | 100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 1123 | 1.0 HP, 1-Ø, (10 - 83)Mtr, (40- 10) LPM |
| 1124 | 1.5HP, 1-Ø, (11 - 94)Mtr, (40 - 10) LPM |
| 1125 | 2.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM |
| 1126 | 3.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound |
| 1127 | 5.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound |
| 1128 | 150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively. |
| 1129 | 3.0 HP, 3-Ø, (40 -110)Mtr, (280-50) LPM |
| 1130 | 5.0 HP, 3-Ø, (72 - 161)Mtr, (230-48) LPM |
| 1131 | 7.5 HP, 3-Ø, (85-165)Mtr, (300-100) LPM |
| 1132 | 10.0 HP, 3-Ø, (110 - 212)Mtr, (400-167) LPM |
| 1133 | 12.5 HP, 3-Ø, (129 - 250)Mtr, (400-163) LPM |
| 1134 | 15.0 HP, 3-Ø, (150 - 280)Mtr, (400-167) LPM |
| 1135 | SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect. |
| 1136 | 0.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body) |
| 1137 | 1.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & CI Body) |
| 1138 | 1.5 HP, 1-Ø, (15-40)Mtr, (78-15) LPM ( Bronze impeller & CI Body) |
| 1139 | 2.0 HP, 3-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body) |
| 1140 | 3.0 HP, 3-Ø, (12 - 26)Mtr, (470-275) LPM ( Bronze impeller & CI Body) |
| 1141 | 5.0 HP, 3-Ø, (19-44)Mtr, (550-300) LPM ( Bronze impeller & CI Body) |
| 1142 | SITC of Dewatering Submersible Motor Pump set, motor should be IP68/F class/IE3class suitable to handle raw sewage suitable for Minimum 25 mm solid and CI Impellor, CI body & housing ( as per IS-210 standard) and SS shaft, Double mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly. |
| 1143 | 1.0 HP, 3-Ø, (5 - 10)Mtr, (350 - 50) LPM |
| 1144 | 2.0 HP, 3-Ø, (8 - 15)Mtr, (480 - 50) LPM |
| 1145 | 3.0 HP, 3-Ø, (8 - 18)Mtr, (800 - 76) LPM |
| 1146 | 5.0 HP, 3-Ø, (10 - 20)Mtr, (940 - 75) LPM |
| 1147 | SITC of Drain Sewage pump Non-clog, Semi-open, single vane with alloy cutter fully floodable submersible pump motor should be IP68/F class/IE3, suitable to handle raw sewage suitable for Minimum 25 mm solid with CI Impellor, CI body & housing, SS shaft, Double Mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively, 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly. |
| 1148 | 1.0 HP, 3-Ø, (4 - 12)Mtr, (400 - 45) LPM |
| 1149 | 2.0 HP, 3-Ø, (8 - 16)Mtr, (375 - 40) LPM |
| 1150 | 3.0 HP, 3-Ø, (8 - 22)Mtr, (590 - 80) LPM |
| 1151 | SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect. |
| 1152 | 0.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank |
| 1153 | 0.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank |
| 1154 | 1.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank |
| 1155 | 1.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank |
| 1156 | Providing & Fixing of CI foot valve complete in all respect as required. |
| 1157 | 50/ 60 mm |
| 1158 | 80/ 100 mm |
| 1159 | Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra) |
| 1160 | 32mm dia |
| 1161 | 40 mm dia. |
| 1162 | 50 mm dia. |
| 1163 | 65 mm dia. |
| 1164 | 80 mm dia. |
| 1165 | 100 mm dia. |
| 1166 | SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect. |
| 1167 | For single phase Submersible / Monoblock pump |
| 1168 | 0.5 HP to 1.5 HP (DOL starter) |
| 1169 | 2.0 HP to 3.0 HP (DOL starter) |
| 1170 | 5.0 HP (DOL starter) |
| 1171 | For Three phase Submersible / Mono block pump |
| 1172 | Upto 3.0 HP ( DOL starter ) |
| 1173 | 3.0 HP to 5.0 HP ( DOL starter ) |
| 1174 | 7.5 HP to 10.0 HP ( DOL starter ) |
| 1175 | 3.0 HP to 5.0 HP ( Star / Delta starter ) |
| 1176 | 7.5 HP to 10.0 HP ( Star / Delta starter ) |
| 1177 | 12.5 HP to 15.0 HP ( Star / Delta starter ) |
| 1178 | 20.0 HP ( Star / Delta starter ) |
| 1179 | 25.0 HP ( Star / Delta starter ) |
| 1180 | 30.0 HP ( Star / Delta starter ) |
| 1181 | Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect. |
| 1182 | 3 kVA |
| 1183 | 4 KVA |
| 1184 | 5 kVA |
| 1185 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 1186 | 50 mm dia per running inch length |
| 1187 | 100 mm dia per running inch length |
| 1188 | 150 mm dia per running inch length |
| 1189 | 200 mm dia per running inch length |
| 1190 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. . |
| 1191 | Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required. |
| 1192 | Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day for 26 Working Days in a month) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India |
| 1193 | Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field |
| 1194 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 1195 | Technical Helper Having basic Knowledge of E&M Services |
| 1196 | Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India |
| 1197 | Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field |
| 1198 | Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field ) |
| 1199 | Technical Helper Having basic Knowledge of E&M Services |
| 1200 | Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan) |
| 1201 | 900/1200 mm sweep (New model ceiling fan) |
| 1202 | 1400 mm sweep (New model ceiling fan) |
| 1203 | All sizes (Old model ceiling fan) |
| 1204 | Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site |
| 1205 | Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required. |
| 1206 | Fans w/o Removing & Refixing |
| 1207 | Fans with Removing & Refixing at Suitable Location |
| 1208 | Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor. |
| 1209 | Provinding & Replacement of M.S. Shaft of ceiling fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1210 | P & Replacement of cover/ bearing seat of ceiling/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1211 | P & F Aluminium Blades (a set of 3 blades) duly painted and well finished 900/ 1200 mm. The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008 |
| 1212 | P & F Aluminium Blades (a set of 3 blades) duly painted/ powder coated. ( 1400/ 1500 mm) The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008 |
| 1213 | P & F of rubber gromet (fan insulator) |
| 1214 | Providing and Replacement of Gun metal bush of ceiling/exhaust/cooler fan/ as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1215 | Spray painting of ceiling fan of size 900/1200/ 1400/ 1500 mm with two coats of white/ brown enamelled paint after cleaning with sand paper. Filling etc. as required. |
| 1216 | P & replacement of 4 nos. supporting legs of 20'' fan motor with rubber pads of desert cooler as required.Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1217 | Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1218 | 300/ 380 mm sweep |
| 1219 | 450 mm sweep |
| 1220 | 600 mm sweep |
| 1221 | Rewinding of 400 mm table fan/pedestal fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1222 | Rewinding of single phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1223 | 0.25 H.P. To 0.50 H.P. |
| 1224 | 0.75 H.P. To 1.0 H.P. |
| 1225 | 2.0 H.P. |
| 1226 | Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1227 | 3.0 H.P. |
| 1228 | 5.0 H.P. |
| 1229 | 7.5 H.P. |
| 1230 | 10.0 H.P. |
| 1231 | 12.5 H.P. |
| 1232 | 15.0 H.P. |
| 1233 | S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire. |
| 1234 | Starting capacitor |
| 1235 | 20-30 micro farad |
| 1236 | 40-60 micro farad |
| 1237 | 60-80 micro farad |
| 1238 | 80-100 micro farad |
| 1239 | 100-120 micro farad |
| 1240 | 120-150 micro farad |
| 1241 | Running capacitor |
| 1242 | 2.5/3.15 micro farad |
| 1243 | 4.0 micro farad |
| 1244 | 6.0 micro farad |
| 1245 | 8.0 micro farad |
| 1246 | 10.0 micro farad |
| 1247 | 15.0 micro farad |
| 1248 | 20.0 micro farad |
| 1249 | 25.0 micro farad |
| 1250 | P & Replacement of plastic/metallic sheet condensor holder suitable for ceiling fan/ exhaust fan /motor etc complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1251 | Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1252 | 0.5 H.P. To 1.0 H.P. |
| 1253 | 2.0 H.P. |
| 1254 | Above 3.0 HP to 5.0 HP |
| 1255 | From7. 5 HP to 10.0 HP |
| 1256 | Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. |
| 1257 | 0.5 H.P. To 1.0 H.P. |
| 1258 | 2.0 H.P. |
| 1259 | Above 3.0 HP to 5.0 HP |
| 1260 | From7. 5 HP to 10.0 HP Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender