Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57771893

Tender For Rate Contract For Day To Day Electrical Work At Sms Medical College Jaipur

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
25 Lakhs
Estimated cost
Bid Submission
08 Oct 2026
6 days left
EMD
50000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rate Contract For Day To Day Electrical Work At Sms Medical College Jaipur

BOQ

Name of Work:- Rate Contract for Day to Day Electrical work at SMS Medical College Jaipur
Sl. No. Item Description
1Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminum round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 6 A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
2Short point (up to 3 mtr.)
3Medium point (up to 6 mtr.)
4Long point (up to 10 mtr.)
5Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal,2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
6Short point (up to 3 mtr.)
7Medium point (up to 6 mtr.)
8Long point (up to 10 mtr.)
9Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
10On board
11S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including making jhiri in the wall,clamps at suitable spacing, covering conduit and making good the same as required.
1220 mm
1325 mm
1432 mm
1540 mm
1650 mm
17Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
18Short point (up to 3 mtr.)
19Medium point (up to 6 mtr.)
20Long point (up to 10 mtr.)
21Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, Aluminium round tiles, 2 Nos 1.2 mm thick Hot dipped Galavanized MS box with earth terminal, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
22Short point (up to 3 mtr.)
23Medium point (up to 6 mtr.)
24Long point (up to 10 mtr..)
25Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galavanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
26On board
27Short point (up to 3 mtr.)
28Medium point (up to 6 mtr.)
29Long point (up to 10 mtr..)
30S&F of following sizes of polypropelene corrugated flexible conduit including gland on both side of flexible conduit as required.
3116 mm OD
3220 mm OD
3325 mm OD
3432 mm OD
3540 mm OD
36Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal/Surface mounted UPVC molded modular box, 6 A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required.
37Short point (up to 3 mtr.)
38Medium point (up to 6 mtr.)
39Long point (up to 10 mtr.)
40Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 2 Nos 6 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate, screws, making connections, testing etc. as required.
41Short point (up to 3 mtr.)
42Medium point (up to 6 mtr.)
43Long point (up to 10 mtr.)
44Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal/Surface mounted UPVC molded modular box, 6 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.
45On board
46S&F following sizes (dia.) of ISI marked MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required on surface including heavy duty saddles with base at spacing of 0.60 mtr. etc as required.
4720 mm
4825 mm
4932 mm
5040 mm
5150 mm
52Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size , 6 A switch, 3 pin ceiling rose/holder / 3 way connector , 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
53Short point (up to 3 mtr.)
54Medium point (up to 6 mtr.)
55Long point (up to 10 mtr.)
56Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade (IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 2 Nos 6 A two way switch,3 pin ceiling rose / holder/ 3 way connector, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
57Short point (up to 3 mtr.)
58Medium point (up to 6 mtr.)
59Long point (up to 10 mtr..)
60Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible class 2 copper earth conductor 1.1 kV grade(IS:694) on surface ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick Hot dipped Galvanized MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required.
61On board
62S&F following sizes of ISI marked ( IS:14927 P - II ) uPVC trunking along with accessories like coupler, inner, outer, elbow, square box, tee, end cap etc. on surface with screws, expansion fasteners etc. as required.
6320 mm x 12 mm
6425 mm x 12 mm
6532 mm x 12 mm
6638 mm x 25 mm
6750 mm x 16 mm
6850 mm x 50 mm
6975 mm x 50 mm
70100 mm x 50 mm
71100 mm x 100 mm
72150 mm x 50 mm
73150 mm x 100 mm
74Supplying and laying FR PVC insulated & unsheathed flexible copper conductor of following nominal sizes with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.
751 x 1.5 sq.mm
762 x 1.5 sq.mm
773x 1.5 sq.mm
784 x 1.5 sq.mm
791 x 2.5 sq.mm
802 x 2.5 sq.mm
812 x 2.5 sq. mm. + 1x1.5sqmm
823 x 2.5 sq.mm
834 x 2.5 sq.mm
841 x 4.0 sq.mm
852 x 4.0 sq.mm
863 x 4 sq. mm.
874 x 4.0 sq.mm
882 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
891 x 6.0 sq.mm
902 x 6.0 sq.mm
913 x 6.0 sq. mm.
924 x 6.0 sq.mm
932 x 6.0 sq. mm. + 1 x 2.5 sq. mm.
942 x 6.0 sq. mm. + 1 x 4.0 sq. mm.
951 x 10.0 sq.mm
962 x 10.0 sq.mm
974 x 10.0 sq.mm
981 x 16.0 sq.mm
992 x 16.0 sq.mm
1004 x 16.0 sq.mm
101Supply and Laying of PE Insulated, PVC Inner Sheathed, armoured & PVC Sheathed Telephone Cable. with 0.5 mm thick Solid Annealed Bare Copper Conductor as per IS: 8130/84 telephone cable confirming to TEC specifications GR/WIR 06/03, Mar.-2002 in existing pipe / open trench / Cable tray / on surface including making necessary connection, testing etc. as required of size.
1025 pair
10310 pair
104Supply and Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1051.5 Sq.mm 3 core flat / Round
1062.5 Sq.mm 3 core flat / Round
1074.0 Sq.mm 3 core flat / Round
1086.0 Sq.mm 3 core flat / Round
10910.0 Sq.mm 3 core flat / Round
11016.0 Sq.mm 3 core flat / Round
111Supply and laying following size twin parallel type Speaker cables made with multi wire, bright annealed flexible bare electrolytic grade copper conductor, insulated with specially formulated transparent grade PVC compound, red strip for identification in existing conduit etc. as required.
1120.75 sq.mm
1131.0 Sq. mm
114Supply and laying PVC Insulated and PVC Round Sheathed Multi Core copper conductor (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from copper, stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing pipe / open trench / Cable tray / on surface including making connection etc. as required.
1151.5 sq.mm x 3 core
1161.5 sq.mm x 4 core
1171.5 sq.mm x 6 core
1181.5 sq.mm x 8 core
1192.5 sq.mm x 3 core
1202.5 sq.mm x 4 core
1212.5 sq.mm x 6 core
1222.5 sq.mm x 8 core
1234.0 sq.mm x 3 core
1244.0 sq.mm x 4 core
1254.0 sq.mm x 6 core
126P & F 1.2 mm thick Hot dipped galvanized boxes with brass earthing terminal of following sizes (nominal size) in recessed/surface as required.
12775mm x 75mm x 60mm
128100mm x 100mm x 60mm
129150mm x 75mm x 60mm
130175mm x 100mm x 60mm
131150mm x 150mm x 60mm
132225mm x 100mm x 60mm
133200mm x 150mm x 60mm
134200mm x 125mm x 75mm
135200mm x 250mm x 75mm
136200mm x 250mm x 100mm
137250mm x 300mm x 75mm
138250mm x 300mm x 100mm
139300mm x 375mm x 75mm
140300mm x 375mm x 100mm
141250mm x 100mm x 60mm
142300mm x 100mm x 60mm
143300mm x 300mm x 75mm
144P & F paper phenolic resin bonded laminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brass screws, washers/ zinc plated nut and bolts as required.
1453.0 mm thick
1465.0 mm thick
1476.0 mm thick
148P & F phenolic laminated sheet 2.0 mm thick of following size . Including screws, cup washer as required.
14975 mm dia
150100 mm dia.
151P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required.
15275 mm dia.
153100 mm dia.
154P & F Aluminium sheet 1.0 m thick of following size dia. Including screws, cup washer as required.
15575 mm dia.
156100 mm dia.
157P & F 1.2 mm thick M.S. Recessed concealed box, round of size 150 mm dia, depth 100 mm complete as required.
158Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required.
159Single pole MCB (With B / C curve tripping characteristics)
1600.5 A to 5 A rating
1616 A to 32 A rating
16240 A rating
16350/63 A rating
16480 A rating
165100 A rating
166125 A rating
167Double pole MCB (With B / C curve tripping characteristics)
1680.5 A to 5 A rating
1696 A to 32 A rating
17040 A rating
17150/63 A rating
17280 A rating
173100 A rating
174125 A rating
175Triple pole MCB (With B / C curve tripping characteristics)
1766 A to 32 A rating
17740 A rating
17850/63 A rating
17980 A rating
180100 A rating
181Four pole MCB (With B / C curve tripping characteristics)
18240 A rating
18350/63 A rating
18480 A rating
185100 A rating
186Triple pole MCB (With D curve tripping Characteristics)
1876 A to 32 A rating
18840 A rating
18950/63 A rating
190Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 25 sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
191Two pole 30 mA sensitivity
1926A-32 A rating
19340 A rating
19463 A rating
195Two pole 100/300mA sensitivity
1966A-32 A rating
19740 A rating
19863 A rating
199Four pole 30 mA sensitivity
2006A-32 A rating
20140 A rating
20263 A rating
203Four pole 100/300 mA sensitivity
2046A-32 A rating
20540 A rating
20663 A rating
207P&F 240/415 V AC Change Over Miniature circuit breaker with three positions (I-O-II) which allows supply change over from one source to second source & vice- versa, conforming to IS/ IEC 60947-3 in existing board/sheets including making connections, testing etc. as required.
208Double Pole
20925 Amp, 2 Module
21040 Amp, 2 Module
21163 Amp,3 Module
212FourPole
21340 Amp, 4 Module
21463 Amp, 6 Module
215Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 25 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required.
216Two pole 30 mA sensitivity
21716/25 A rating
21832/40 A rating
21963A rating
220100 A rating
221Two pole 100/300mA sensitivity
22216/25 A rating
22340 A rating
22463 A rating
225Four pole 30 mA sensitivity
22625 A rating
22740 A rating
22863 A rating
229100 A rating
230Four pole 100/300 mA sensitivity
23125 A rating
23240 A rating
23363 A rating
234100 A rating
235Providing & Fixing of din rail mounting surge protection device confirming to IEC 61643-11 for Type 1 + 2 protection and Maximum discharge current 50 kA with following configuration in existing distribution board / sheet including making connections, testing etc. as required.
2361P + N
2373P + N
238Providing & Fixing of din rail mounting LED Indicating Lights with following description and configuration in existing distribution board / sheet including making connections, testing etc. as required.
239Red / Yellow / Blue / Green
240Red-yellow-Blue
241Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with din rail making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required.
242Suitable for Two / Three / Four module for MCB
243Suitable for Six / Eight module for MCB/ RCCB
244Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door (Metal / Glazed / Acrylic) Distribution board with Metal end box made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, complete with 100 amp. insulated copper bus bar/shorting link , brass neutral link with shrouds, brass earth link , door earthing arrangement, color coded interconnecting wire set of minimum 10.0 sqmm size and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required.
245Metal door (single phase) IK-09 and IP-43 with Metal end box
2464 Way
2476 Way
2488 Way
24912 Way
25016 Way
251Glazed / Acrylic door (single phase) IK-09 and IP-43 with Metal end box
2524 Way
2536 Way
2548 Way
25512 Way
25616 Way
257Metal door (Three phase) IK-09 and IP-43 with Metal end box
2584 Way (8 incomer + 12 Outgoing)
2596 Way (8 incomer + 18 Outgoing)
2608 Way (8 incomer + 24 Outgoing)
26112 Way (8 incomer + 36 Outgoing)
262Glazed / Acrylic door (Three phase) IK-09 and IP-43 with Metal end box
2634 Way (8 incomer + 12 Outgoing)
2646 Way (8 incomer + 18 Outgoing)
2658 Way (8 incomer + 24 Outgoing)
26612 Way (8 incomer + 36 Outgoing)
267Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box
2684Way {8 Incomer + 6 Sub Incomer (2+2+2) + 12 out going }
2696Way {8 Incomer + 6 Sub Incomer (2+2+2) + 18 out going }
2708Way. {8 Incomer + 6 Sub Incomer (2+2+2) + 24 out going }
27112 Way {8 Incomer + 6 Sub Incomer (2+2+2) + 36 out going }
272P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required.
27320 amp, (2P + E), 1 Module
27420 amp, (2P + E), 2 Module
27520 amp, (2P + E), 3 Module
27632 amp, (3P + E), 3 Module
27732 amp, (3P + N + E) 8 Module (with Polyamide Plug & Socket)
27863 amp, (3P + N+ E), 8 Module (with Polyamide Plug & Socket)
279P & F of Industrial plug and socket conforming to IEC 60309-1/2 made out of self extinguishing engineering polymer / polyamide, nickel plated brass sleeve and pins, socket with shutter including making connection etc as reqd.
280IP -67, IK - 09 Panel mounted socket
28116 A (2P+E)
28232 A (2P+E)
28332 A (3P+N+E)
28463 A (3P+N+E)
285IP -67, IK-09 Surface/Wall mounted socket
28616 A (2P+E)
28732 A (2P+E)
28832 A (3P+N+E)
28963 A (3P+N+E)
290IP -66, Surface/Wall mounted Interlocked switched socket Outlet with Provision of MCB
29116 A (2P+E) 250 V
29232 A (2P+E), 250 V
29332 A (3P+E), 415 V
29432 A (3P+N +E), 415 V
29563 A (3P+N +E), 415 V
296IP - 67 Plug top
29716 A (2P+E)
29832 A (2P+E)
29932 A (3P+E)
30032 A (3P+N+E)
30163 A (3P+N+E)
302Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for MCB / RCCB/ RCBO up to 63 Amp and SP / TP MCB upto 32 Amp. as outgoing ,made out from Galvanized steel / CRCA sheet, powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3 complete with insulated 100 A rating copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
303Double door IK-09 & IP-43 with Metal end box
3044 Way (8 Incomer +12 Outgoing)
3056 Way (8 Incomer +18 Outgoing)
3068 Way (8 Incomer +24 Outgoing)
30712 Way (8 Incomer + 36 Outgoing)
308Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box with provision of incomer suitable for 3/4 pole MCCB and SP / TP MCB up to 63 Amps. as outgoing ,made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. complete with insulated 125/160/200/250 Amp. copper bus bar, brass neutral bars with shrouds, brass earth bar , color coded interconnecting wire set of suitable rating and din bar, door earthing arrangement, masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required.
309Double door IP-43 & IK-09 with Provision of Incomer MCCB up to 125 A Rating with Metal end box
3104 Way
3116 Way
3128 Way
31312 Way
314Double door IP-43 & IK-09 with Provision of Incomer MCCB 160 A Rating with Metal End Box
3154 Way
3166 Way
3178 Way
31812 Way
319Double door IP-43 & IK-09 with Provision of Incomer MCCB 200/250 A Rating with metal End Box
3204 Way
3216 Way
3228 Way
32312 Way
324P & F Surface mounting IP-65, IK-09 Class-II self extinguishing insulating material weather proof cabinets confirming to EN60439-3 with IP-65 Key lock, fully reversible door and cabinet, removable chasis and face plates, of following size.
3253/4 module
3266 module
3278 module
3281 row 12 module
3292 row 24 module
3303 row 36 module
331P & F ISI marked (IS:3854) 6 amp. flush type non modular switch with CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
332P & F ISI marked (IS :3854) 16 amp. flush type non modular switch CM/L no. printed and made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
333Providing & Fixing of 6 amp. Combined flush type non modular socket and switch set made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
334Providing & Fixing of 16 amp. Combined flush type non modular socket and switch set with indicator and fuse set, made out from industrial grade Polycarbonate material including cutting hole in tile and making connection testing etc. as required.
335Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push surface type CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
336Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch surface type, CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
337Providing & Fixing of ISI marked (IS :3854) non modular 6A bell push flush type CM/L no. printed and made out from industrial grade Polycarbonate materialincluding cutting hole in tile and making connection testing etc. as required.
338Providing & Fixing of ISI marked (IS :3854) twin control non modular 6A switch flush type CM/L no. printed , made out from industrial grade Polycarbonate material, including cutting hole in tile and making connection testing etc. as required.
339Providing & Fixing of non modular 6A hanging bell push/one way switch made out from industrial grade Polycarbonate material including making connection testing etc. as required.
340Providing & Fixing of IS:1293 marked of 3 pin 6 amp. flush type non modular socket CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
341Providing & Fixing of IS:1293 3/6 pin 16 amp flush type non modular socket CM/L no. printed and made out from Industrial grade Polycarbonate material, brass terminal with Porcelain based back cover & captive screws including cutting hole in tile and making connection testing etc. as required.
342Providing & Fixing of ISI marked (IS:371) 6 amp surface type 3 pin ceiling rose with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
343Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal & captive screws including making connection testing etc. as required.
344Providing & Fixing of ISI marked (IS:1293) 6 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
345Providing & Fixing of ISI marked (IS:1293) 16 amp unbreakable 3 pin plug top having lamp indicator with CM/L no. printed and made out from industrial grade Polycarbonate material, brass terminal including making connection testing etc. as required.
346Providing & Fixing of flush type non modular 2 pin telephone socket with plug top made out from industrial grade Polycarbonate material, brass terminals including making connection testing etc. as required.
347Providing & Fixing of flush type non modular single line telephone jack made out from industrial grade Polycarbonate material, including making connection testing etc. as required.
348Providing & Fixing of flush type non modular double line telephone jack made out from industrial grade Polycarbonate materialincluding making connection testing etc. as required.
349Providing & Fixing of flush type non modular coaxial T.V. socket made out from industrial grade Polycarbonate material,including making connection testing etc. as required.
350Providing & Fixing of IS 11037 marked non modular socket size flush type 100 watt rotary minimum 5 step fan regulator with CM/L no. printed and made out from industrial grade Polycarbonate material including making connection testing etc. as required.
351P & F ISI marked 32 A D.P. switch with fuse and indicating lamp including making connection testing etc. as required.
352Providing & Fixing of ISI marked (IS:302) gong bell with CM/L no. printed including making connection testing etc. as required.
353Providing & Fixing of Non Modular Neon Light including making connection testing etc. as required.
354Providing & Fixing of single / multi tone electronic call bell / remote bell including making connection testing etc. as required.
355Providing & Fixing of ISI marked (IS:302) ding dong/musical chime bell including making connection testing etc. as required.
356Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant virgin UV Stabilized Polycarbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating ,minimum width of switch toggle( PUSH PART ) should not less then 20mm, including making connections, testing etc as required.
3576 A one way switch
3586 A two way switch
3596 A bell push
36010 A one way switch
36110 A two way switch
36216 A one way switch 1M
36320 A one way switch 1M
36420 A one way switch 2M
36516 Amp. 2 Module switch With Led Indicator
36632 Amp. 2 Module switch With Led Indicator
367Providing & Fixing of IS:1293 marked modular type lockable feature socket with CM/L no. printed duly made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
3686 A 3 pin shuttered socket
3696/16 A shuttered socket
370Providing & Fixing of modular type 100W Step Fan regulator duly ISI marked (IS 11037) with CM/L no. printed made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , including making connections, testing etc as required.
3715 step fan regulator 2 Module
372Providing & Fixing of following modular accessories, made out of unbreakable and fire retardant virgin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating, including making connections, testing etc as required.
37325 Amp. 2 Module Motor Starter with on / off Push button
374Modular MCB 6 A to 32 A SP
375Modular MCB 6 A to 32 A DP
376Providing & Fixing of following size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
3771/2 Module
3783 Module
3794 Module
3805 Module
3816 Module
3828 Module
38310 Module
38412 Module
38516/18 Module
386Providing & Fixing of following size cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.
3871/2 Module
3883 Module
3894 Module
3905 Module
3916 Module
3928 Module
39310 Module
39412 Module
39516/18 Module
396Providing & Fixing of Hot dipped Galvanized metal box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.
3971-2 Module
3983 Module
3994-5 Module
4006-8 Module
40110-12 Module
40216/18 Module
403Providing & Fixing of Wiring Accessories OEM fabricated following size virgin material UPVC modular boxes on surface suitable for modular accessories as required.
4041-2 Module
4053 Module
4064/5 Module
4076 / 8 module
40810 / 12 module
40916/18 module
410Providing & Fixing of Multiple socket with surge and spikes protection cartridge not less then 5 KV with minimum four nos. universal 6 A sockets, one 6 A switch and 3 pin company fitted plug top and 3 core multistrand copper lead minimum 1.5 mtr. including making connection etc as required.
411Providing & Fixing of DLP PVC adaptable trunking system for cable management including finishing accessories like corners, tees, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. OEM have to submit NABL accrediated /CPET lab test reports /EN 50085-2-1 complaince certificate.
41280mm x 50mm
413100/105mm x 50mm
414150/160mm x 50mm
415195/200mm x 50mm
416Providing and fixing of power plug point with non modular accessories with Galvanized box of 1.2 mm thick with earth terminal with suitable size 3.0 mm thick phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16 amp. Switch (IS :3854) and 3/6 pin 16 amp. socket outlet making connection , testing , etc. as required.
417Supplying and fixing of power plug point with Modular accessories on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required.
418P & F Portable Residual Current Device (PRCD) 3 pin plug top 16 A, 30 mA sensitivity. Plug should have feature of power indicator, test button and reset function etc. as required.
419SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-
420(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided
421(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.
422[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )
423(d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.
424(e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.
425(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )
426(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.
427(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)
428Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator, with short circuit withstand capacity of 31 MVA for 1 Sec. , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves.
429Electrolytic grade Aluminium bus bar 6010 grade
430Providing & Fixing of IS: 1248(part-1) 2003 confirming Moving Iron panel meter, 90 degree Analog type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter of class 1.0 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
431Voltmeter ( 0 to 500V )
432Ammeter (Direct Reading / CT Operated)
433Providing & Fixing of IS: 13875 & IEC :61326/IEC:62053-22 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT opertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.
434Single Phase Ammeter
435Single Phase Voltmeter
436Three phase Ammeter with Inbuilt Selector Switch
437Three phase Voltmeter with Inbuilt Selector Switch
438Three phase KWH Meter
439Three phase KWH Meter Dual Source
440Frequency Meter
441Three phase AMP+HZ+PF+KW+KVA+KVAR+T.ENERGY+THD-I, THD-V & RUN HRS Meter
442Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS Meter
443Three phase with universal Auxiliary supply + AMP + HZ + PF + KW + KVA + KVAR + KVARH + KWH + DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 Meter
444Providing & Fixing of Current Transformer confirming IS 2705-I (1992) with secondary terminal and shorting Block , with all necessary support in existing panel including connection etc. as required Current transformer Ring Type Tape Wound/Resin Cast Wound Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required .
445Ring type tape wound CT
446C T Class 1, Ratio up to 150/5, Burden 5 VA
447C T Class 1, Ratio 200/5 to 600/5, Burden 10 VA
448C T Class 1, Ratio 800/5 to 1200/5, Burden 15 VA
449C T Class 1, Ratio 1500/5 to 3000/5, Burden 15 VA
450Providing & Fixing of selector switch of 10 A for voltmeter using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. Switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
451Voltage Between Phases with OFF ( 4 Position )
452Voltage Between Phases & Individual Phases to Neutral with OFF ( 7 Position )
453Providing & Fixing of CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range 25 degree C to 55 degree C, frequency upto 10 KHz. switch life under standard operating conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc. as required .
454Providing & Fixing of 10 A Cam operated rotary (Local- Remote, Auto - manual) switches on existing panel with 1 pole 2 way and off position using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc. as required .
455Providing & Fixing of 25 A TNC ( Trip - neutal - close ) switch to control remotely on existing panel as required.
456Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required.
457Red/yellow/Green colour
458Blue / white Colour
459Providing & Fixing of flush head push button actuators IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 27 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, including connection etc. as required.
460Non luminous type
461Luminous type Red , Yellow, Green, Amber
462Luminous type Blue , white
463Providing & Fixing of Electrical insulating rubber matts confirming to IS: 15652 / 2006 with one side anti skid aberration marks and pasting the mat with synthetic rubber adhesive as required.
4643.3 KV, class A 2 mm thick with proof voltage 10 KV AC (rms) and Break Down Voltage 30 KV AC (rms)
46511 KV, Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage 45 KV AC (rms)
466Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor confirming to IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.
4673 pole Power contactors with following AC 3 Rating
468Up to 12 Amp
46916 to 25 Amp
47032 Amp.
47140 Amp
47250 Amp
47370 Amp
47480 Amp
47595 Amp
476140 Amp
477185 Amp
478250 Amp
479300 Amp
480400 Amp
4814 pole Power contactors with following AC 1 Rating
48216 Amp.
48325/32 Amp.
48440 Amp
48550/55 Amp
48663 Amp
487100/105 Amp
488160 Amp
489200 Amp
490250 Amp
491325 Amp
492400 Amp
493500 Amp
494600 Amp
495900 Amp
496P & F of Control relays (Auxiliary Contactor) for AC control standard. 24 V Coil 110, 240 V, 415 V, 50 Hz conforming to IS:13947-4-1/IEC:60947-4-1 with required NO & NC combination including making connections, testing etc. as required.
497P & F of Front / Side mounting Add on Auxiliary Contact Block with required NO & NC combination including making connections, testing etc. as required.
498Providing & Fixing of thermal over load relay with built in single phase protection and having at least 1NO & 1NC contacts, manual /auto reset facility including making connection testing etc. as required.
499Up to 14 Amp
50014 to 23 Amp
50120 to 33 Amp
50224 to 40 Amp
50336 to 60 Amp
50445 to 75 Amp
50566 to 110 Amp
506P & F of 240 / 415 V Electronic ON - OFF Timer 3 -30 Sec / 12 - 120 Sec including making Connection etc. as required.
507Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.
508One day reserve (Electromechanical type )
509One day & week reserve (digital type )
510Providing & Fixing of 110 - 240 V, AC, 1 ph. , 2 W Astronomical time switch with surge suppressor, memory card, Sunrise / Sunset selectable, software for programming including making connection, etc. as required.
511Providing & Fixing of IP54 direct or CT operated, 1x240 / 3x240 volts , 50 Hz static watt-hour meter (kwh) , having resolution 0.1 / 0.01 kwh , confirming to IS:13779/ IS:15959, LED indicators for tamper operation ( Reverse &/or earth connection) , pulsating LED indicator for meterology , LCD Display, cover plate for body and terminal sealing , push button for all standard parameters, including making connection ,testing etc. as required.
512up to 30 ampere single phase meter acc. Cl 1
51310 A to 60 ampere Single phase meter acc. Cl 1
5143ph, 4W KWh CT Operated Base mounting 240 V-/5A acc. Cl 0.5s
5153ph, 4W KWh Direct Base mounting 240 V 10-60 Amp acc. Cl 1
516P & F of Automatic Transfer Switch (ATS) confirming to IEC60947-6-1, Utilization cateogory AC-33B with OEM fabricated enclosure for automatic on load transfer between two source power supply of 415V through Solenoid/Motorised mechanism and integrated with three positions realize fast transfer within 180 ms (for solenoid) and within 2.6 sec.(for motorised). ATS shall have three postions (S1-OFF-S2) , Manual / Auto Override feature, The two sources can be isolated in the off position with a padlock. capability to expand with RS 485 communication module, which can ensure real-time transmission of communication data. ATS shall have automatic generator start & stop control function; Auxillary contacts to indicate mechanical positions. Minimum Electrical operations 6000, of following Current ratings, including making connections etc. as required.
51763 Amps
518125 Amps
519160 Amps
520200 Amps
521250 Amps
522315 Amps
523400 Amps
524630 Amps
525800 Amps
526P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel with circuit breaker having inbuilt overload protection or separate thermal Overload relay , Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF, Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CT's, provision for potential free contacts making connection, testing etc. as required.
527Direct on line (DOL) Starter with following Motor rating
528Motor rating 0.55 KW
529Motor rating 0.75 KW
530Motor rating 1.5 KW
531Motor rating 2.2 KW
532Motor rating 4.0 KW
533Motor rating 5.5 KW
534Motor rating 7.5 KW
535Motor rating 9.0 KW
536Star - Delta Starter with following Motor rating
537Motor rating 4.0 KW
538Motor rating 5.5 KW
539Motor rating 7.5 KW
540Motor rating 9.0 KW
541Motor rating 11.0 KW
542Motor rating 15.0 KW
543Motor rating 18.5 KW
544SITC of Microprocessor based Draw out type 3/4 pole door interlock Air Circuit Breaker (ACB) as conforming to IS/IEC 60947 P - 2 :2003 in existing LT panel suitable for LT installation 440/415 V, 50 Hz and having adjustable over load, short-circuit, Instantaneous, earth fault (LSIG) with separate LED indication or Fault details on display for each type of fault shall confirm to EMI/ EMC test , LCD/LED display, last 10 trip history, Inbuilt ZSI, Current metering, Provision for Communication, Thermal memory, trip free mechanism, modular design and suitable for ambient 50 degree and utilization catagary B. In built electrical & mechanical anti pumping feature , pollution degree 3, 100% rated neutral . ACB shall have separate indication for service, test, isolation & maintenance position, Breaking capacity Icu = Ics = Icw ( 1 sec ) , U imp - 12 KV, break time not more then 30 ms. Provision for electrical & mechanical interlock between ACB sand other required accessories (Cost of accessories to be paid extra) Min.electrical operation 10000 upto 1600 A rating and 5000 for 2000 A to 4000 A. including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
545Manual spring charged type 4 Pole
546630/800 A Rating , 50 kA
5471000 A Rating , 50 kA
5481250 A Rating ,50 kA
549Supply and fixing of following accessories for Air circuit breaker (ACB) in existing ACB including making connection etc complete in all respect.
550Mechanical Interlocking Kit using key & Lock
551Closing Release
552Shunt Trip Release
553Under voltage Release
554External Neutral CT cast resin
555Microswitch for Indication
556Operation Counter
557Door Interlock
558Auxiliary Contact 4 NO + 4 NC
559SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.
5603 pole MCCB With Thermal Magnetic release
561up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
562125 Amp , 25 kA, adjustable O/L & fixed S/C setting,
563160 Amp , 25 kA, adjustable O/L & fixed S/C setting,
564200 Amp , 25 kA, adjustable O/L & fixed S/C setting,
565250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
566400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
567800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
5684 pole MCCB With Thermal Magnetic release
569up to 100 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
570125 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
571160 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
572200 Amp , 25 kA, adjustable O/L & Fixed S/C setting,
573250 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
574400 Amp , 35 kA, adjustable O/L & adjustable S/C setting,
575630 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
576800 Amp , 50 kA, adjustable O/L & adjustable S/C setting,
5774 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection.
578Upto 160 Amp , 50 kA
579250 Amp , 50 kA
580400 Amp , 50 kA
581630 Amp, 50 kA
582800 Amp , 50 kA
583Supply and fixing of following accessories for Moulded case circuit breaker (MCCB) compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect.
584Shunt Trip Release
585Under Voltage Release
586Extended Rotary Handle
587Direct Rotary Handle
588Mechanical Interlocking kit
589Motor mechanism for 250A MCCB (240V, 50Hz)
590Motor mechanism for 400A MCCB (240V, 50Hz)
591Motor mechanism for 630A MCCB (240V, 50Hz)
592Auxiliary contact
593Trip Alarm contact
594Auxiliary + Trip alarm contact
595Spreaders upto 125A, 3 Pole MCCB
596Spreaders for 160A, 3 Pole MCCB
597Spreaders for 160A, 4 Pole MCCB
598Spreaders for 250A, 3 Pole MCCB
599Spreaders for 250A, 4 Pole MCCB
600Spreaders for 400A, 3Pole MCCB
601Spreaders for 400A, 4Pole MCCB
602Spreaders for 630A, 3Pole MCCB
603Spreaders for 630A, 4Pole MCCB
604Spreaders for 800A, 3Pole MCCB
605Spreaders for 800A, 4Pole MCCB
606Phase Barriers up to 630A, 3/4Pole MCCB
607External Neutral CT with Adaptor Kit
608Current Metering Module
609Providing & Fixing of IK08 and IP-30 Recessed/surface mounting heavy duty Enclosure suitable for mounting 3 / 4 pole MCCB, Inbuilt neutral linkmade out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted complete with din rail making internal DB terminations, detachable gland plate, including making connections, testing etc. as required.
610Suitable to accommodate up to 70 sqmm 3.5 core Al arm. Cable
611Suitable to accommodate above 70 sqmm 3.5 core Al arm. Cable to 185 Sqm , 3.5 core Al Arm. Cable
612SITC of IP-43 surface mounting heavy duty modular Sub main Distribution board (SMDB) fabricated by MCCB OEM in his own factory having short circuit withstand current 35 kA (upto 400 amp.Incomer ) and 50 kA for 630 amp. Incomer with suitable bottom cabling box, 4 no. corner boxes, 2 no. side cabling boxes, metering Extension box with provision of incomer suitable for 3/4 pole MCCB and 3/4 pole MCCB as outgoing, Ammeter, Voltmeter, Indicating lamp, made out from Galvanized steel / CRCA sheet of 1.2/1.6 mm thick conforming to IEC 61439 Part 1 & 2. , U imp 8 KV, form of separation 2b, powder painted complete with insulated suitable rating tinned copper bus bar, neutral bars with shrouds, earth bar , din bar, making internal DB terminations with copper lugs, detachable gland plate, including making connections, testing etc. as required. (Without MCCB, ammeter, voltmeter, selector switch , Indicating lamp)
613SMDB with 250 Amp. Incoming and 4 no. 100 Amps Outgoing
614SMDB with 250 Amp. Incoming and 8 no. 100 Amps Outgoing
615SMDB with 250 Amp. Incoming and 12 no. 100 Amps Outgoing
616SMDB with 400 Amp. Incoming and 4 no. 100 Amps Outgoing
617SMDB with 400 Amp. Incoming and 8 no. 100 Amps Outgoing
618Providing & Fixing of on load change over switch, front handle operated, four pole 415 V confirming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.
619Open execution type
620125 A
621160 A
622200 A
623250 A
624320 A
625400 A
626630 A
627800 A
6281000 A
629With OEM fabricated sheet steel enclosure, powder coated, door locking system allow opening of door in OFF position only with 2 nos external earthing points.
630125 A
631160 A
632200 A
633250 A
634320 A
635400 A
636630 A
637800 A
6381000 A
639Providing & Fixing of Four Pole By pass Change Over Switch confirming to IS:13947(Part 3) : IEC:60947-3-1 and IEC:60947-6-1, Open execution type in the following ratings.
640100 A
641200 A
642320 A
643400 A
644630 A
645800 A
6461000 A
647Providing & Fixing of bus bar chamber housed in sheet metal box Confirming to IEC-60439/ IS-8623 & IEC-60529/ IS-2147 made out from 1.6 mm thick powder coated CRCA sheet,degree of protection IP-31 front openable bus bar made out of aluminium or wrought aluminium alloy suitable for 200 amp. Capacity , bus bar fixed on porcelain/DMC insulators at approved spacing including making connections etc. as required.
648300 mm long , 4 strip
649450 mm long , 4 strip
650600 mm long , 4 strip
651900 mm long , 4 strip
652Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.
6536.0 Sq. mm
6542 core
6553 core
6564 core
65710.0 Sq. mm
6582 core
6593 core
6604 core
66116.0 Sq. mm
6623 core
6634 core
66425.0 Sq. mm
6653.5 core
66635.0 Sq. mm
6673.5 core
66850.0 Sq. mm
6693.5 core
67070.0 Sq. mm
6711 core
6723 core
6733.5 core
67495.0 Sq. mm
6751 core
6763.5 core
677120.0 Sq. mm
6781 core
6793.5 core
680150.0 Sq. mm
6811 core
6823.5 core
683185.0 Sq. mm
6841 core
6853.5 core
686240.0 Sq. mm
6871 core
6883.5 core
689300.0 Sq. mm
6901 core
6913.5 core
692400.0 Sq. mm
6931 core
6943.5 core
695500.0 Sq. mm
6961 core
6973.5 core
698Excavation of trench of size 75 cm (Depth) x 35 cm(Width) for laying of suitable no. of LT cables (Inter spacing between cables should not be less than 2 D) in ground with following procedure :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 100 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable, (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth.
699Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
700Excavation of trench of size additional 20 cm in width, with procedure as per following points :- (a) Make a river sand bed of height 100 mm along the trench, (b) Lay another cable in middle of trench in such manner that spacing between another cable is 20 cm., (c) Provide river sand bed of height 100 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 /Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically (Longest side is vertical to cable) along the cable , (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
701Add Extra in Item no. 11.7 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
702Add Extra in item no. 11.1 to 11.4 for Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
703Up to 35 Sq.mm fixed with 25 mm x 2 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
704Above 35 sq. mm and upto 95 sq. mm fixed with 40 mm x 3 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
705Above 95 sq. mm and upto 185 sq. mm fixed with 40 mm x 4 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
706Above 185 sq. mm and upto 400 sq. mm fixed with 50 mm x 5 mm thick suitable length red oxide and enamel painted MS clamp and base, pvc rawl plug and screws of sufficient size with spacing 0.6 Mtr. Between Clamps.
707Add extra in item no. 11.1 to 11.4 for Laying Charges for cable through Manual Boggi by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
708Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required.
709Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.
7102 x 4.0 sq.mm
7112 x 6.0 sq.mm
7122 x 10.0 sq.mm
7132 x 16.0 sq.mm
7142 x 25.0 sq.mm
7152 x 35.0 sq.mm
7162 x 50.0 sq.mm
7172 x 70.0 sq.mm
7183 x 4.0 sq.mm
7193 x 6.0 sq.mm
7203 x 10.0 sq.mm
7213 x 16.0 sq.mm
7223 x 25.0 sq.mm
7233 x 35.0 sq.mm
7243 x 50.0 sq.mm
7253 x 70.0 sq.mm
7263.5 x 25.0 sq.mm
7273.5 x 35.0 sq.mm
7283.5 x 50.0 sq.mm
7293.5 x 70.0 sq.mm
7303.5 x 95.0 sq.mm
7313.5 x 120.0 sq.mm
7323.5 x 150.0 sq.mm
7333.5 x 185.0 sq.mm
7343.5 x 240.0 sq.mm
7353.5 x 300.0 sq.mm
7363.5 x 400.0 sq.mm
7373.5 x 500.0 sq.mm
7383.5 x 630.0 sq.mm
7394 x 4.0 sq.mm
7404 x 6.0 sq.mm
7414 x 10.0 sq.mm
7424 x 16.0 sq.mm
7431 x 70.0 sq.mm
7441 x 95.0 sq.mm
7451 x 120.0 sq.mm
7461 x 150.0 sq.mm
7471 x 185.0 sq.mm
7481 x 240.0 sq.mm
7491 x 300.0 sq.mm
7501 x 400.0 sq.mm
7511 x 500.0 sq.mm
7521 x 630.0 sq.mm
7531 x 800.0 sq.mm
7541 x 1000.0 sq.mm
755Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty Copper lugs (IS 8337- 1976) duly crimped with crimping tool, PVC tape for following size of PVC insulated & PVC sheathed/ XLPE copper conductor cable of 1100 volt grade as required.
7561 x 16.0 sq.mm
7571 x 25.0 sq.mm
7581 x 35.0 sq.mm
7591 x 50.0 sq.mm
7601 x 70.0 sq.mm
7611 x 95.0 sq.mm
7621 x 120.0 sq.mm
7632 x 4.0 sq.mm
7642 x 6.0 sq.mm
7652 x 10.0 sq.mm
7662 x 16.0 sq.mm
7672 x 25.0 sq.mm
7682 x 35.0 sq.mm
7692 x 50.0 sq.mm
7702 x 70.0 sq.mm
7712 x 95.0 sq.mm
7722 x 120.0 sq.mm
7733 x 1.5 sq.mm
7743 x 2.5 sq.mm
7753 x 4.0 sq.mm
7763 x 6.0 sq.mm
7773 x 10.0 sq.mm
7783 x 16.0 sq.mm
7793 x 25.0 sq.mm
7803 x 35.0 sq.mm
7813 x 50.0 sq.mm
7823 x 70.0 sq.mm
7833 x 95.0 sq.mm
7843 x 120.0 sq.mm
7854 x 1.5 sq.mm
7864 x 2.5 sq.mm
7874 x 4.0 sq.mm
7884 x 6.0 sq.mm
7894 x 10.0 sq.mm
7904 x 16.0 sq.mm
7914 x 25.0 sq.mm
7924 x 35.0 sq.mm
7934 x 50.0 sq.mm
7944 x 70.0 sq.mm
7954 x 95.0 sq.mm
7964 x 120.0 sq.mm
7976 x 1.5 sq.mm
7986 x 2.5 sq.mm
7998 x 1.5 sq.mm
8008 x 2.5 sq.mm
80110 x 1.5 sq.mm
80210 x 2.5 sq.mm
80312 x 1.5 sq.mm
80412 x 2.5 sq.mm
805Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
8061.5 Sq.mm
8072.5 Sq.mm
8084.0 Sq.mm
8096.0 Sq.mm
81010.0 Sq.mm
81116.0 Sq.mm
81225.0 Sq.mm
81335.0 Sq.mm
81450.0 Sq.mm
81570.0 Sq.mm
81695.0 Sq.mm
817120.0 Sq.mm
818150.0 Sq.mm
819185.0 Sq.mm
820240.0 Sq.mm
821300.0 Sq.mm
822400.0 Sq.mm
823500.0 Sq.mm
824630.0 Sq.mm
825800.0 Sq.mm
8261000.0 Sq.mm
827Supplying and making end termination with heavy duty Copper lugs ( ANY type ) confirming to IS 8309 -1993 duly crimped with crimping tool, PVC tape etc of following size.
8281.5 Sq.mm
8292.5 Sq.mm
8304.0 Sq.mm
8316.0 Sq.mm
83210.0 Sq.mm
83316.0 Sq.mm
83425.0 Sq.mm
83535.0 Sq.mm
83650.0 Sq.mm
83770.0 Sq.mm
83895.0 Sq.mm
839120.0 Sq.mm
840Supply, Fabricating & installing following sizes of perforated Hot dipped Galvanized iron cable tray ( Galvanized thickness not less then 50 microns) with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.
841100mm x 50mm x 1.6mm
842150mm x 50mm x 1.6mm
843225mm x 50mm x 1.6mm
844300mm x 50mm x 1.6mm
845375mm x 50mm x 2.0mm
846450mm x 50mm x 2.0mm
847600mm x 50mm x 2.0mm
848300mm x 62.5mm x 2.0mm
849375mm x 62.5mm x 2.0mm
850450mm x 62.5mm x 2.0mm
851600mm x 62.5mm x 2.0mm
852750mm x 62.5mm x 2.0mm
853600mm x 75mm x 2.0mm
854Supply, Fabricating & installing following sizes of Hot dipped Galvanized iron Ladder type cable tray ( Galvanized thickness not less then 50 microns) with rungs at span of 250mm including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling/wall with M.S. suspenders etc. as required.
855100mm x 50mm x 1.6mm
856150mm x 50mm x 1.6mm
857225mm x 50mm x 1.6mm
858300mm x 50mm x 1.6mm
859375mm x 50mm x 2.0mm
860450mm x 50mm x 2.0mm
861600mm x 50mm x 2.0mm
862300mm x 62.5mm x 2.0mm
863375mm x 62.5mm x 2.0mm
864450mm x 62.5mm x 2.0mm
865600mm x 62.5mm x 2.0mm
866750mm x 62.5mm x 2.0mm
867600mm x 75mm x 2.0mm
868750mm x 75mm x 2.0mm
869Supplying and fixing of CE certified and UL listed GI wire mesh cable tray made from spot welded steel wire hot dipped galvanised between 60 and 80 microns of zinc as per BS 729 including horizontal and vertical bends, reducers, tees, cross members and other OEM made accessories like wall clamp, hold down clamps, Earthing terminal, brackets as required, and duly suspended from the ceiling with electro-zinc coated TF rods, etc. as required of following sizes.
870100 mm x 50 mm x 3.5 - 5.9 mm
871150 mm x 50 mm x 3.5 - 5.9 mm
872200 mm x 50 mm x 3.5 - 5.9 mm
873300 mm x 50 mm x 3.5 - 5.9 mm
874400 mm x 50 mm x 3.5 - 5.9 mm
875500 mm x 50 mm x 3.5 - 5.9 mm
876100 mm x 100 mm x 3.5 - 5.9 mm
877150 mm x 100 mm x 3.5 - 5.9 mm
878200 mm x 100 mm x 3.5 - 5.9 mm
879300 mm x 100 mm x 3.5 - 5.9 mm
880400 mm x 100 mm x 3.5 - 5.9 mm
881500 mm x 100 mm x 3.5 - 5.9 mm
882S & Making Heat shrinkable type Tubular sleeve version outdoor straight through joint for following size of PVC/ XLPE insulated aluminium conductor cable of 1.1 KV grade as required.
8831 x 25 sq.mm-50 sq.mm
8841 x 70 sq.mm-150 sq.mm
8851 x 185 sq.mm-300 sq.mm
8861 x 400 sq.mm
8871 x 500 sq.mm
8883/3.5/4 x 1.5 sq.mm-6 sq.mm
8893/3.5/4 x 10.0-16.0 sq.mm
8903/3.5/4 x 25.0 sq.mm-50 sq.mm
8913/3.5/4 x 70.0 sq.mm-150 sq.mm
8923/3.5/4 x 185.0 sq.mm-300 sq.mm
8933/3.5/4 x 400 sq.mm
8943/3.5/4 x500 sq.mm
895S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required
896P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
89750 mm
89863 mm
89975 mm
90090 mm
901110 mm
902120 mm
903160 mm
904200 mm
905Providing and laying Non Pressure NP-3 class R.C.C. pipes confirming to IS:458 including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra).
906200 mm Dia.
907250 mm dia.
908300 mm dia
909450 mm dia.
910Plate Earthing as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
911Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
912SITC of Copper Bonded rod Earthing with high tensile strength (more than 600 N / sq.mm low carbon steel rod molecularly bonded with Copper thickness (250 microns) and confirming to UL 467 of following size and length and as per point mentioned (a), (b), [c), (d), (e) below :-
913(a) Bore a hole of dia. 100 mm of required length, Place the rod in the centre of Hole
914(b)Earth enhancing compound to ensure the moisture content and electrical conductivity, 25 kg for 3000 mm. The compound shall be tested form NABL accredited lab for low resistivity (less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content in accordance with IEC 62561-7
915© Connect the rod with copper Strip/Conductor/Wire with suitable clamp made from tinned copper and SS 304 Bolt
916(d) Place Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm.
917(e) Testing of earth resistance for value of 5 ohms or less as required.
918(f) Test certificates for confirming above standards from OEM is mandatory.
91917.2 mm thick and 3 Mtr. Long
92025 mm thick and 3 Mtr. Long
921Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.
92220mm x 3mm copper strip
92325mm x 3mm copper strip
92425mm x 5mm copper strip
92520mm x 3mm tinned copper strip
92625mm x 3mm tinned copper strip
92725mm x 5mm tinned copper strip
92820mm x 3mm G.I. ( Hot Dipped ) Strip
92925mm x 3mm G.I. ( Hot Dipped ) Strip
93025mm x 6mm G.I. ( Hot Dipped ) Strip
931Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required.
9326 SWG tinned copper Wire
9338 SWG tinned copper Wire
93410 SWG tinned copper. Wire
9356 SWG copper Wire
9368 SWG copper Wire
93710 SWG copper. Wire
9386 SWG G.I. ( Hot Dipped ) Wire
9398 SWG G.I. ( Hot Dipped ) Wire
94010 SWG G.I. ( Hot Dipped ) Wire
94116 Sq.mm Copper coated steel stranded conductor (Wt. 130 Kg/Km)
94225 Sq.mm Copper coated steel stranded conductor ( Wt. 200Kg/Km)
943Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. (Earth Excavation will be Paid Extra)
94415 mm dia.
94520 mm dia.
94625 mm dia.
94732mm dia
94840 mm dia.
94950 mm dia.
95065 mm dia.
95180 mm dia.
952100 mm dia.
953150 mm dia.
954Supply and installation of an 8 mm aluminum down conductor, designed for efficient dissipation of lightning currents. The conductor shall be securely fixed using corrosion-resistant clamps at appropriate intervals, ensuring a continuous, low-resistance path from the air terminal to the earthing system. The conductor length shall be determined based on actual site conditions, with all necessary accessories, including clamps, connectors, and fasteners.
955Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size.
956Up to 457 mm size
957more than 457 mm & up to 610 mm
958Supply & Fixing of phenolic laminated board of 6.0 mm thick for fresh air fan/exhaust fan up to size of 300 mm on existing window frame including cost of board, cutting of hole , Nut bolts etc. as required.
959Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor, Cotter pin, rubber grommet making connection testing etc. as required.
960With regulator
961Without regulator
962Providing & Fixing BLDC technology step regulator compatible ceiling fan, with aluminium body & aluminium blade, power factor not less then 0.9 , following service value (CMM/W) , with following air delivery , speed 350 RPM ( tolerance as per IS:374 2019 ) THD less then 10%, copper winding with class of Insulation 'F' complete with with secondary support safety cable ( steel rope), down rod up to 30 cm, cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required.
9631200 mm sweep with Air delivery >/= 230 CMM and Service Value 8.20
9641400 mm sweep with Air delivery >/= 270 CMM and Service Value 7.70
965Providing & Fixing of of BLDC Technology ventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutter including making connection, testing etc. as required.
966150 mm sweep with Min. Air delivery 350 Cubic meter/Hr, 2000 RPM
967200 mm sweep with Min. Air delivery 800 Cubic meter/Hr, 1600 RPM
968250 mm sweep with Min. Air delivery 1150 Cubic meter/Hr, 1300 RPM
969Providing & Fixing of 400 mm Sweep BLDC technology Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Double Wall bearing with front and back 120 or more ribs guard; Three no. blades, noise level should be <= 75 dB, including fixing with anchor bolts, making connection testing etc. as required. ( With Remote )
970Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM
971Pedestal Type having Adjustable Height with Service value 2.6 CMM /W, Min. Air Delivery 85 CMM
972Providing & Fixing of BEE Star rated copper wounded with class of Insulation 'F', double ball bearing capacitor start, aluminium body & aluminium blade ceiling fan conforming to all the performance requirements laid down in IS 374:2019 with down rod up to 30 cm with secondary support safety cable ( steel rope) , cotter pin, shackle kit with 3 x 1.5 sq.mm pvc insulated flexible copper conductor and making connection testing etc. as required.
9731200 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
9741400 mm Sweep BEE 1 Star rated (service value >=4.0 to < 4.5 )
975Providing & Fixing of shackle (iron hook) made from 2mm nominal thick CRCA sheet and bolts (2nos) of 6mm with spring washer nut, checknut & split pin as required.
976Providing & Fixing of of M.S. J- hook of standard design made out of 16 mm dia. M.S. round bar and fixed with cement concrete mortar with required support as required.
977P & F 1.2 mm thick M.S. Recessed fan box and top lid screwed on Box, hexagonal/ round of size 130 mm dia, depth 75mm, 12 mm dia rod fan hook with 150 mm length extended on each side as required.
978P & F 3.0 mm thick Poly propelene plastic polished concealed fan box, squre of size (106x106) mm dia, depth 50 mm , 10 mm dia rod of MS with chrome plated with 55 mm length extended on each side as required.
979Providing & Fixing of of Double ball bearing, copper wounded capacitor start single phase metallic blade fresh air fan, in existing opening including cost of hardware , flexible 3 core 1.5 Sq.mm copper conductor ,making connections, testing etc. as required.
980230 mm sweep, Minimum air delivery 750 Cum / hour
981300 mm sweep Minimum air delivery 1600 Cum / hour
982Providing & Fixing of Heavy duty capacitor start, copper wound Double ball bearing 900/1400 RPM single phase Exhaust fan conforming to IS:2312 marked in existing opening including making connections testing etc. as required.
983300 mm sweep(900 RPM)
984380 mm sweep(900 RPM)
985450 mm sweep(1400 RPM)
986600 mm sweep(900 RPM)
987Providing & Fixing of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required.
988150 mm sweep Minimum Air Delivery 150 Cum / hour
989200 mm sweep Minimum Air Delivery 450 Cum / hour
990250 mm sweep Minimum Air Delivery 750 Cum / hour
991Providing & Fixing of Wall mounting / Pedestal type Heavy duty Air Circulator , Double ball bearing and with metal sturdy mesh guard; Aluminium alloy one piece blade and conforming to IS:2997, including fixing with anchor bolts, making connection testing etc. as required.
992450 mm sweep Wall mounting and three speed regulator with Minimum Air Delivery 150 Cum. / Minute
993450 mm sweep Pedestal type and three speed regulator with Minimum Air Delivery 150 Cum. / Minute
994600 mm sweep Wall mounting with Minimum Air Delivery 270 Cum. / Minute
995Providing & Fixing of 450 mm Sweep Oscillating type Wall mounting / Pedestal type fans with Three speed, ON and OFF position, Sintered Iron bush oil impregnated, with metal front and back 120 or more ribs guard; Three no. Aluminium blades, minimum Air delivery 100 Cum. / Minute , Minimum Service Value 1.11 Cum./min/watt, noise level should be <= 75 dB, power consumption <= 120 watts, motor protection through thermal overload protection device, including fixing with anchor bolts, making connection testing etc. as required.
996Wall mounting type with Adjustable Vertical Angle
997Pedestal Type with Adjustable Height
998Providing & Fixing of extra down rod of 15 mm dia . ERW (Electrical resistance welded ) of 1.6mm nominal thick medium duty steel pipe including cutting, threading, drilling, fixing quarter pin etc as required.
999Numbering of ceiling fans/ fixtures with approved enamel paint etc as required.
1000P & F of Gravity Louver shutter of superior quality made out of frame of 18 swg M.S. sheet & Louvers made from 24 swg MS Sheet with enamel paint including cost of nuts, bolts, etc as required.
1001Up to 380 mm size
1002above 380 mm size
1003P & F of Wall cowl with Bird Screen Suitable for Outside Wall of Exhaust Fan Opening of following size and made out from 24 SWG GI sheet as per instructions of Engineer in charge including fixing with suitable fasteners etc. as required.
1004Suitable for 300 mm sweep Exhaust Fan
1005Suitable for 380 mm sweep Exhaust Fan
1006Suitable for 450 mm sweep Exhaust Fan
1007S & F Extruded Aluminium Fresh Air / External Weather Louver, Small Format type with 38 mm flange width & 50 mm depth. finish - powder coated off white with aluminium mesh of required size.
1008SITC of single phase 230 V, 50 Hz, Permanent Magnet synchronous motorised (PMSM) High volume low speed (HVLS) fan comprising of aviation grade extruded Alluminium alloy 6063-T grade aerofil 5/6 blade, Suitable Hanging bracket with extension tube for suitable clearance from blade to ceiling, Fastners, Nut bolts, PVC coated GI guy Wire rope, VFD control panel, sound level 45-50 dB, suitable cable from control panel to Fan motor of following sizes.
100924' dia, floor to fan blade height 27-30 ft,. Area coverage 18500 sq.ft, air delivery 380000 cfm, 55 RPM
1010Providing & Fixing of Vertical(BEE 5 star rated) / Horizontal( BEE 3 star rated) storage water heater with outer casing made of Engineering Plastic sheet (Upto 25 Ltr) / Metal rust proof Body (35 & 50 Ltr), Glass - line / Titanium Enamel coated Pressure Pump Compatible 8 bar pressure Inner tank, Glass Line Coated , mineral filled heating element, stem type, snap action adjustable thermostat , Dual indicating lamps Injected PUF insulation, Multi Function Valve etc. as required held in position with 2/4 no. 10/12 mm anchor Fastener, duly wired with 3 core 2.5/4.0 Sqmm PVC insulated & sheathed copper conductor and 16 A/25A three pin plug top , including making inlet, outlet Flexible alloy connection, testing etc. as required.
101125 Ltr.
101250 Ltr.
1013Providing & Fixing of stem type ISI marked (IS 3017 / 85) snap action adjustable thermostat for storage water heater including making connection testing etc. complete in all respect.
1014Providing & Fixing of stem type ISI marked (IS 3017 / 85) , snap action bipolar adjustable thermostat with built in auto thermal cut out for storage water heater including making connection testing etc. complete in all respect.
1015Providing & Fixing 2 / 3 KW nickle plated, mineral filled heating element including making connection testing etc complete in all respect.
1016Providing & Fixing of 2 / 3 KW Glass Line Coated , mineral filled heating element including making connection testing etc complete in all respect.
1017Providing & Fixing of Multi safety valve of 8.5 bar capacity with built in drain, NRV, Vacuum release, Pressure release etc. as required complete in all respect.
1018Providing & Fixing of Twin neon indicating lamp of superior quality for storage water heater complete in all respect.
1019Providing & Fixing of 13 mm Brass with C.P. finished ISI marked angle valve for storage water heater as required complete in all respect.
1020Providing & Fixing of heavy duty flexible alloy pipe for storage water heater for inlet and outlet of suitable length including the cost of nuts, washers etc complete in all respect.
1021450 mm
1022600 mm
1023Charges for descaling of storage water heater including replacement of Multi Function Valve as required.
1024Charges for Fixing of storage water heater including 10/12 mm Anchor fasteners of suitable size, testing, carrying from store to site,etc. as required.
1025Providing & Fixing of 2.0 KW twin ceremic cartridge, Withstands temperatures up to 1000 C long lasting even in hard water including making connection testing etc complete in all respect.
1026SITC of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output only at CW (5700K to 6500K) , internal surge protection of 4.0 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
10271170mm(+/-10%) LED batten with min. lumen output 2200 lm
1028SITC of IP-20 LED Recessed / Surface Mounted, Round / Square backlit & SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS compliance 4.0 KV surge protected Isolated driver, with Short & Open circuit protection input 320VAC-48 hr protection, input 350VAC-2 hr protection), having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt,at CW (5700K to 6500K) , THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1029Recessed Mounting
1030Minimum lumen output 1950 lm
1031Minimum lumen output 2400 lm
1032Surface Mounting (with extruded alumn. Housing )
1033Minimum lumen output 1950 lm
1034Minimum lumen output 2400 lm
1035SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V . High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection ( input 320VAC-48 hoursprotection,input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1036Recessed Mounting
1037Minimum lumen output 4800 lm
1038Surface Mounting (Driver should be Inside the Luminaire)
1039Minimum lumen output 4800 lm
1040SITC of IP20, 1'X1' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution.operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1041Recessed Mounting
1042Minimum lumen output 2880 lm
1043Minimum lumen output 3600 lm
1044Surface Mounting (Driver should be Inside the Luminaire)
1045Minimum lumen output 2880 lm
1046Minimum lumen output 3600 lm
1047SITC of IP20, 1'x4' LED Surface/ Recessed mounting Mid power SMD type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmisivity UV stabilized Non -yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85% , with Short & Open circuit protection (Integral with light fixture). System lumen efficacy of ≥ 120 lm/Watt ,THD < 10 % , p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
1048Recessed Mounting
1049Minimum lumen output 4800 lm
1050Surface Mounting (Driver should be Inside the Luminaire)
1051Minimum lumen output 4800 lm
1052SITC of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) as required.
105318/20 Watt
1054Providing & Fixing of IP-65 Protected LED aviation obstruction light luminaire comprising of die cast aluminium alloy housingwith Polycarbonate enclosure having more than 200 No's Low Power LED's having minimum power consumption 15 watts complete in all respect.
1055aviation obstruction LED light luminaire 12/15 Watts
1056Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass with suitable lenses on LED / integrated lens diffuser to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated metal case potted driver as a unique BIS R number (as per IS 15885) having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate(Fitting & driver both have separate BIS R number). The System level Luminaire efficacy >=130 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , LED driving output current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K as required.
1057High Power LED Flood Light Minimum lumen outpu 3900 lm
1058High Power LED Flood Light Minimum lumen output 6500 lm
1059High Power LED Flood Light Minimum lumen output 10400 lm
1060High Power LED Flood Light Minimum lumen output 13000 lm
1061High Power LED Flood Light Minimum lumen output 15600 lm
1062High Power LED Flood Light Minimum lumen output 65000 lm
1063Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED/ integrated lens diffuser & should be High power LED of 3 to 5 watt each . The System efficacy >=125 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.
1064LED Street Light fixture with Minimum lumen output 5625 lm
1065LED Street Light fixture with Minimum lumen output 7500 lm
1066LED Street Light fixture with Minimum lumen output 8750 lm
1067LED Street Light fixture with Minimum lumen output 11250 lm
1068LED Street Light fixture with Minimum lumen output 12500 lm
1069LED Street Light fixture with Minimum lumen output 26250 lm
1070Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mm fabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 6 Amp MCB complete in all respect.
1071Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect.
1072125 mm X 200 mm X 122 mm
1073160 mm X 225 mm X 100 mm
1074200 mm X 200 mm X 122 mm
1075225 mm X 225 mm X 100 mm
1076Providing & Fixing of Street light bracket made out from following size of ' B ' class , Medium class G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with heavy duty pole clamp, Saddles suitable fastners etc. as required.
107720 mm Dia.
107825 mm Dia.
107932 mm Dia.
108040 mm Dia.
1081Providing & Fixing of IP - 65 protected impact resistant polycarbonate / Polysterene enclosures with knock out for cable entry/out including fixing with nut, bolt, fatner etc as required complete in all respect of following sizes.
1082180 x 180 x 91 mm
1083250 x 200 x 115 mm
1084300 x 450 x 132 mm
1085320 x 440 x 179 mm
1086320 x 640 x 179 mm
1087S & F of 12V VRLA Lead Acid Sealed maintenance free (SMF) batteries of following capacity with Warranty of 2 years
10887.0 AH
108912 AH
109018 AH
109126 AH
109228 AH
109334 AH
109442 AH
109565 AH
1096100 AH
1097120 AH
1098150 AH
1099Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect.
1100Delowering and Lowering
1101Providing & Fixing of HDPE pipe Confirming to IS:4984:2021 for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect.
1102for vertical installation
110340 mm OD 6 kg / cm2
110450 mm OD 6 kg / cm2
110563 mm OD 6 kg / cm2
110675 mm OD 6 kg / cm2
110790 mm OD 10 kg / cm2
1108for Horizontal installation
110940 mm OD 4kg/ cm2
111050 mm OD 4 kg/ cm2
111163 mm OD 4 kg/ cm2
111275 mm OD 4 kg/ cm2
111390 mm OD 6 kg/ cm2
1114SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal. The motor body of single phase pump shall be of SS and rest of all shall be of cast iron. Shaft of three phase pump shall be of SS 410 grade. All casting parts should be cathod electro deposition (CED) coated. Motor winding shall be 100% copper wire material. Dynamically balanced rotating parts to ensure min. vibration etc. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.
11150.5 HP, 1-Ø, (7 -18) Mtr, (180 - 20) LPM
11161.0 HP, 1-Ø, (12 -27) Mtr, (200- 30) LPM
11171.5 HP, 1-Ø, (18 -33) Mtr, (160-35) LPM
11182.0 HP, 1-Ø, (9 -21) Mtr, (475 - 130) LPM
11193.0 HP, 3-Ø, (17 -27) Mtr, (680 - 250) LPM
11205.0 HP, 3-Ø, (13 -36) Mtr, (995-200) LPM
1121SITC of Radial / mixed flow water and anti-corrosive liquid filled submersible motor pump sets suitable for 100/150mm dia borewell. The size of adopter fixed on top of the motor should exceed the top of coupler , for safegaurd the coupler. The job includes labour part of lowering of riser pipe G.I./ H.D.P.E. with rope, cables & pump, installation of complete fitting and accessories, jointing of electrical cables up to Starter. All labour for testing of submersible pumps set and supply of water to water mains, complete in all respect.
1122100 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
11231.0 HP, 1-Ø, (10 - 83)Mtr, (40- 10) LPM
11241.5HP, 1-Ø, (11 - 94)Mtr, (40 - 10) LPM
11252.0 HP, 1-Ø, (7- 95)Mtr, (55-22) LPM
11263.0 HP, 1-Ø, (40 -170)Mtr, (60- 20) LPM Copper Wound
11275.0 HP, 1-Ø, (56 - 236)Mtr, (90 - 25) LPM Copper wound
1128150 mm diameter Submersible pump shall have following HP Rating, phase, Head range, Discharge range respectively.
11293.0 HP, 3-Ø, (40 -110)Mtr, (280-50) LPM
11305.0 HP, 3-Ø, (72 - 161)Mtr, (230-48) LPM
11317.5 HP, 3-Ø, (85-165)Mtr, (300-100) LPM
113210.0 HP, 3-Ø, (110 - 212)Mtr, (400-167) LPM
113312.5 HP, 3-Ø, (129 - 250)Mtr, (400-163) LPM
113415.0 HP, 3-Ø, (150 - 280)Mtr, (400-167) LPM
1135SITC of Monoblock closed coupled motor pump set with TEFC motor, motor should be IP55-F class and IE2 efficiency for monobloc, with carbon steel /SS-410 shaft, Mechanical seal, Single/Three phase Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively and Dynamically balanced rotating parts to ensure min. vibration etc. complete in all respect.
11360.5 HP, 1-Ø, (8 - 26)Mtr, (50-10) LPM (SS Impellor & SS Body)
11371.0 HP, 1-Ø, (10-30)Mtr, (76-28) LPM ( Bronze impeller & CI Body)
11381.5 HP, 1-Ø, (15-40)Mtr, (78-15) LPM ( Bronze impeller & CI Body)
11392.0 HP, 3-Ø, (6-27)Mtr, (250-100) LPM ( Bronze impeller & CI Body)
11403.0 HP, 3-Ø, (12 - 26)Mtr, (470-275) LPM ( Bronze impeller & CI Body)
11415.0 HP, 3-Ø, (19-44)Mtr, (550-300) LPM ( Bronze impeller & CI Body)
1142SITC of Dewatering Submersible Motor Pump set, motor should be IP68/F class/IE3class suitable to handle raw sewage suitable for Minimum 25 mm solid and CI Impellor, CI body & housing ( as per IS-210 standard) and SS shaft, Double mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly.
11431.0 HP, 3-Ø, (5 - 10)Mtr, (350 - 50) LPM
11442.0 HP, 3-Ø, (8 - 15)Mtr, (480 - 50) LPM
11453.0 HP, 3-Ø, (8 - 18)Mtr, (800 - 76) LPM
11465.0 HP, 3-Ø, (10 - 20)Mtr, (940 - 75) LPM
1147SITC of Drain Sewage pump Non-clog, Semi-open, single vane with alloy cutter fully floodable submersible pump motor should be IP68/F class/IE3, suitable to handle raw sewage suitable for Minimum 25 mm solid with CI Impellor, CI body & housing, SS shaft, Double Mechanical seal etc. as required. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively, 10 Mtr cable length etc. complete in all respect. The submersible pumpset shall be suspended with chain for ease of connection and disconnection from discharge pipe assembly.
11481.0 HP, 3-Ø, (4 - 12)Mtr, (400 - 45) LPM
11492.0 HP, 3-Ø, (8 - 16)Mtr, (375 - 40) LPM
11503.0 HP, 3-Ø, (8 - 22)Mtr, (590 - 80) LPM
1151SITC of Pressure boosting pump with MS Tank, pressure switch, pressure gauge, and all standard fittings fully automatic ON / OFF system, 2900 RPM with stainless steel casing, & impellor suitable for following capacity complete in all respect.
11520.5 HP ( 12 - 26 ) Mtr, (50 - 10 ) with 8 Ltr tank
11530.75 HP -0.90 HP ( 10 - 34 ) Mtr, (72 - 5 ) LPM with 24 Ltr Tank
11541.0 HP ( 10 - 38 ) Mtr, (76 - 8 ) LPM with 24 Ltr Tank
11551.5 HP ( 18-44 ) Mtr, (10-78 ) LPM with 35 ltr tank
1156Providing & Fixing of CI foot valve complete in all respect as required.
115750/ 60 mm
115880/ 100 mm
1159Supply & fixing of GI pipes confirming to IS : 1239 P - 1 ( 2004 ) with socket,elbow,tee, flanges duly screwed & welded including rubber washer, nuts & bolts of 8mm dia complete in all respect. ( If Pipe Laid Underground Excavation and refilling cost will be paid extra)
116032mm dia
116140 mm dia.
116250 mm dia.
116365 mm dia.
116480 mm dia.
1165100 mm dia.
1166SITC of IP 54 OEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Coordination Chart and made out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection(for three phase pumps), Illuminated ON / OFF push buttons, ammeter, voltmeter, indicating lamps, 2P/4P MCB etc. suitable for following rating motors complete in all respect.
1167For single phase Submersible / Monoblock pump
11680.5 HP to 1.5 HP (DOL starter)
11692.0 HP to 3.0 HP (DOL starter)
11705.0 HP (DOL starter)
1171For Three phase Submersible / Mono block pump
1172Upto 3.0 HP ( DOL starter )
11733.0 HP to 5.0 HP ( DOL starter )
11747.5 HP to 10.0 HP ( DOL starter )
11753.0 HP to 5.0 HP ( Star / Delta starter )
11767.5 HP to 10.0 HP ( Star / Delta starter )
117712.5 HP to 15.0 HP ( Star / Delta starter )
117820.0 HP ( Star / Delta starter )
117925.0 HP ( Star / Delta starter )
118030.0 HP ( Star / Delta starter )
1181Supply, Fixing and testing of following capacity IS:8448 marked wall mounted stabilizer having output voltage variation from 200 V to 250 V(+/-5%) with input voltage variation from 170 V to 260 V, time delay facility from 2 to 4 minute and high cutoff at 270 V with providing of 16 Amp /20 Amp Industrial plug top making connection etc complete in all respect.
11823 kVA
11834 KVA
11845 kVA
1185Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia
118650 mm dia per running inch length
1187100 mm dia per running inch length
1188150 mm dia per running inch length
1189200 mm dia per running inch length
1190Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. .
1191Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mm including leveling, Dressing etc. as Required.
1192Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day for 26 Working Days in a month) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
1193Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
1194Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
1195Technical Helper Having basic Knowledge of E&M Services
1196Providing Manpower through Contracting agency for Supervision / Execution / Operation of various Electromechanical Installations. (one shift of 8 working Hrs per day ) on basis of minimum wages + VDA order Dt. 28.03.2025 Ministry of Labour and Employement Govt. of India
1197Engineer with B.Tech and1 Yrs, experience ,/Diploma Engineer with 3 Yrs. Experience in relevant field
1198Wireman, Electrician, Welder, Lineman, AC Mechanic, Fireman, , Supervisor, ELV technician or equivalent professional with ITI or Equivalent course and Experience of 2 years in relevant field )
1199Technical Helper Having basic Knowledge of E&M Services
1200Rewinding of ceiling fan motor (starting and running winding) including all necessary material. The motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor. (New model ceiling fan)
1201900/1200 mm sweep (New model ceiling fan)
12021400 mm sweep (New model ceiling fan)
1203All sizes (Old model ceiling fan)
1204Labour charges for removing and refixing of Ceiling fan/ Exhaust fan from site
1205Charges for oiling, overhauling of ceiling fan, table fan, pedestal fan irrespect to the size of fan including removing,refixing of fan from site and testing etc. as required.
1206Fans w/o Removing & Refixing
1207Fans with Removing & Refixing at Suitable Location
1208Providing and Replacement of ball bearing of ceiling/ exhaust fan and refixing the same at suitable location as requiredand as per OEM recommendations. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material shall be retained by the contractor.
1209Provinding & Replacement of M.S. Shaft of ceiling fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1210P & Replacement of cover/ bearing seat of ceiling/ exhaust fan. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1211P & F Aluminium Blades (a set of 3 blades) duly painted and well finished 900/ 1200 mm. The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008
1212P & F Aluminium Blades (a set of 3 blades) duly painted/ powder coated. ( 1400/ 1500 mm) The material of the fan blade shall be of designation 31500B with condition HX6 aluminium alloy sheet confirming to IS 737/2008
1213P & F of rubber gromet (fan insulator)
1214Providing and Replacement of Gun metal bush of ceiling/exhaust/cooler fan/ as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1215Spray painting of ceiling fan of size 900/1200/ 1400/ 1500 mm with two coats of white/ brown enamelled paint after cleaning with sand paper. Filling etc. as required.
1216P & replacement of 4 nos. supporting legs of 20'' fan motor with rubber pads of desert cooler as required.Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1217Rewinding of Heavy duty Exhaust fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1218300/ 380 mm sweep
1219450 mm sweep
1220600 mm sweep
1221Rewinding of 400 mm table fan/pedestal fan motor including all necessary material,The motor is to be wound taking no. of coils,turns and pitch as it was originally wound with required size super enamelled wire with 'E' class insulation material and making connections etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1222Rewinding of single phase motor of 1400 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
12230.25 H.P. To 0.50 H.P.
12240.75 H.P. To 1.0 H.P.
12252.0 H.P.
1226Rewinding of three phase squirrel cage induction motor of 1400 to 2800 RPM including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
12273.0 H.P.
12285.0 H.P.
12297.5 H.P.
123010.0 H.P.
123112.5 H.P.
123215.0 H.P.
1233S & F of capacitor of 230V/ 275V, 50Hz rating of plastic casing and terminals -Lugs or copper wire.
1234Starting capacitor
123520-30 micro farad
123640-60 micro farad
123760-80 micro farad
123880-100 micro farad
1239100-120 micro farad
1240120-150 micro farad
1241Running capacitor
12422.5/3.15 micro farad
12434.0 micro farad
12446.0 micro farad
12458.0 micro farad
124610.0 micro farad
124715.0 micro farad
124820.0 micro farad
124925.0 micro farad
1250P & Replacement of plastic/metallic sheet condensor holder suitable for ceiling fan/ exhaust fan /motor etc complete as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
1251Rewinding of single phase/3phase submersible motor including all necessary material and of the same characteristics as original with required size of super enamelled wire 'E' class insulation material and testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
12520.5 H.P. To 1.0 H.P.
12532.0 H.P.
1254Above 3.0 HP to 5.0 HP
1255From7. 5 HP to 10.0 HP
1256Repairing of submersible pump of with replacement of broken impellers ,diffuser,bush/bearing set , oil seal complete with testing etc. as required. Replacement of material or components shall be use as per guidelines of OEM of original product. All the scrap material should be retained by the contractor.
12570.5 H.P. To 1.0 H.P.
12582.0 H.P.
1259Above 3.0 HP to 5.0 HP
1260From7. 5 HP to 10.0 HP Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57771893
AUTHORITY Government Departments
TENDER VALUE 25 Lakhs
LAST DATE 08-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Rate Contract For Day To Day Electrical Work At Sms Medical College Jaipur
Basic Detail
Tender No EE_PWD_Medical_NIT_23_2026_27
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 29 Sep 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 25 Lakhs
Tender Fee 500
EMD 50000
Exemption Available
Document List
03conditions.pdf
5d11ec47-9b78-46a6-9493-cc43f4571998.html
BOQ_1066539.xls
Schedulecover3.pdf
Tendernotice_1 (79).pdf
Tendernotice_2 (16).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
pdf

03conditions.pdf

html

5d11ec47-9b78-46a6-9493-cc43f4571998.html

xls

BOQ_1066539.xls

pdf

Schedulecover3.pdf

pdf

Tendernotice_1 (79).pdf

pdf

Tendernotice_2 (16).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders