Tourism Government Departments Closing in 11 days TDR #57771017

Tender For Development Works At Shakambhari Mata Temple ,Sambhar (Rajasthan).

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
19.16 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
11 days left
EMD
38320
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Works At Shakambhari Mata Temple ,Sambhar (Rajasthan).

BOQ

Name of Work:- Development Works at Shakambhari Mata Temple ,Sambhar (Rajasthan).
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils
2Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift.
3Random rubble dry stone Kharanja under floor.
4Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
5Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification .75mm thick.
6Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. ('Original producers' who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code)Thermo-mechanically Treated bars (Conforming of relevent IScode)
7Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix
8Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix
9Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
10Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
11RandomRubble stone masonry for with hard stone infoundationandplinth inCementSandmortar above30CMthick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand).
12Brick work with mechanised autoclaved flyash lime bricksconforming to IS: 12894 :2002 of class designation 100 insuperstructure above plinth level upto floor V level in. Cement mortar 1 : 6 (1 cement : 6 coarse sand)
13Half brick masonry in Superstructure , above plinth level uptofloor V level using bricks of designation 75Cement mortar 1 : 4 (1 cement : 4 coarse sand)
14Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand). For area of each slab from 2001 to 5000 Sq.Cm
15Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. For area of each slab upto 2001 Sqcm
16Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish :20mm thick.
176 mm thick cement plaster to ceiling of mix 1:3 (1cement : 3-fine sand)
18Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.New Plastered Surface (three or more coats)
19Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of basewith primer, putty, lippy etc complete in all respect.
20Finishing walls with textured exterior paint of required shadeas per approved colour complete as per manufacturersspecifications including primer coat and protecting coatincluding scaffolding and safety provisionTrowel Finish av. thickness 1500 to 2000 microns.
21Providing and fixing external grade board solid core singleleaf flush door shutters ISI 2202-67 marked using Phenolformal dehyderesin in glue both sides with approved steelfittings complete as per annexure 'A' :30 mm thick . Commercial Veneer both side
22Providing & Fixing mica of approved make for inner/outer side of shutters with fevicol & nails complete as per approved by engineer in charge.0.8mm thick mica
23Providing and fixing pressed steel door frames confirming toIS 4351 manufactured from commercial mild steel sheet of1.25 mm thickness including hinges jamb, lock jamb, bead andif required angle threshold of mild steel angle of section50x25mm, or base ties of 1.25mm pressed mild steel weldedor rigidly fixed together by mechanical means, adjustable lugswith split end tail to each jamb including steel butt hinges2.5mm thick with mortar guards, lock strike-plate and shockabsorbers as specified and applying a coat of approved steelprimer after pre-treatment of the surface including filling withCC 1:2:4(M15 grade) complete as directed by Engineer-incharge :
24Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to code IS : 15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).
25Extra for using Marble printed / Granite shade or darkshade tiles instead of white, grey, ivory, fume red brown,light green, light blue and other light shades in glazedtiles and MAT finished tiles.
26Extra for using size above 200x300mm in glazed tiles andfor using 400mm x 400mm MAT finished tiles in place of300mm x 300mm size
27Providing and fixing 1st quality MAT finished ceremic tilesize 300x300mm confirming to code IS : 15622 colour suchas white, grey, ivory, fume red brown, light green, light blueand other light shades in floors, steps, pillars etc. laid on a bedof neat cement slurry finished with flush pointing in the whitecement mixed with pigment to match the shade of the tilecomplete (including the cost of cement mortar bed 1:4).
28Extra for using Marble printed / Granite shade or dark shade tiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MAT finished tiles.
29Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size
30Providing and fixing factory made P.V.C. door frame of size50x47mm with a wall thickness of 5mm, made out ofextruded 5mm rigid PVC foam sheet mitred at corners andjoined with 2 Nos. of 150mm long brackets of 15x15mm M.S.square tube, the vertical door profiles to be reinforced with19x19mm M.S. square tube of 19 gauge, EPDM rubber gasketweather seal to be provided through out the frame. The doorframe to be fixed to the wall using M.S. screws of 65/100mmsize complete as per manufacturers specification and directionof Engineer-in-Charge.
31Providing and fixing to existing door frames 30mm thickfactory made polyvinyl chloride (PVC) door shutter made ofstiles and rails of a uPVC hollow section of size 60x30 mmand wall thickness 2mm +/- 0.2mm with inbuilt decorativemoulding edging on one side. The stiles and rails mitred andjoined and the corners by means of M.S.galvanized/plasticbrackets of size 75x220 mm having wall thickness 1.0mmandstainless steel screws. The stiles of the shutter reinforced byinserting galvanized M.S.tube of size 25x20 mm and 1mm +/0.1mm wall thickness. The lock rail made up of „H‟ section, auPVC hollow section of size 100x30 mm and 2mm +/- 0.2mmwall thickness fixed to the shutter stiles by means ofplastic/galvanized M.S.tube „U‟ cleats. The shutter framefilled with a uPVC multi-chambered single panel of size notless than 610mm,having overall thickness of 20mm and1mm+/- 0.1mm wall thickness.The panels filled vertically and tie bar at two places byinserting horizontally 6mm galvanized M.S.rod and fastenedwith nuts and washers.complete as per manufacturer‟sspecification and direction of Engineer-in-charge.(ForW.C.and bathroom door shutter)
32Providing and fixing aluminum work for doors ,windows,ventilators and partition with extruded built up standardtubular / appropriate Z sections and other sections of approvedmake conforming to IS :733 and IS :1285, fixed with rawlplugs and screws or with fixing clips ,or with expansion holdfasteners including necessary filling up of gap. at junctions , attop ,bottom and sides with required PVC/neoprene felt etc.Aluminium section shall be smooth ,rust free, straight ,miteredand jointed mechanically wherever required including cleatangle Aluminium snap beading for glazing /paneling , C.P.brass/ stainless steel screws Al. Tower bolt & Al. handle & Al.Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in– charge .(Glazing and paneling tobe paid for separately). For fixed portionPowder coating aluminum ( minimum thickness of powdercoating 50 micron)
33Providing and fixing aluminum work for doors ,windows,ventilators and partition with extruded built up standardtubular / appropriate Z sections and other sections of approvedmake conforming to IS :733 and IS :1285, fixed with rawlplugs and screws or with fixing clips ,or with expansion holdfasteners including necessary filling up of gap. at junctions , attop ,bottom and sides with required PVC/neoprene felt etc.Aluminium section shall be smooth ,rust free, straight ,miteredand jointed mechanically wherever required including cleatangle Aluminium snap beading for glazing /paneling , C.P.brass/ stainless steel screws Al. Tower bolt & Al. handle & Al.Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in– charge .(Glazing and paneling tobe paid for separately). For shutters builtup standard tubular sections of openabledoors ,windows & ventilators including providing & fixinghinges / rollers etc. and making provision for fixing offittings wherever required (lockes shall be paid forseparately).Powder coating aluminum ( minimum thickness of powdercoating 50 micron)
34Extra for shutters of sliding aluminum windows
35Providing and fixing glazing in aluminium door, window,ventilator shutters and partitions etc. with PVS / neoprenegasket etc. complete as per the architectural drawings and thedirections of engineer-in-charge.(Cost of aluminium snapbeading shall be paid in basic item.) With float glass panes of 5.0 mm thickness ( weight not lessthan 13.50 kg/sqm)
36Providing and fixing expanded grill made of aluminum as per designand drawing having members section of size 7.5mm x 6.0mm andopening of size 102mm x 99mm to aluminum window/vent withrequired screws, Y and H aluminium section (as per drawing) at theends and middle joints respectively complete in all respect as perdirection of engineer in charge. Powder coating aluminum ( minimum thickness of powder coating50 micron)
37Grading roof for water proofing treatment with water proffing compound. Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
38Crazy marble stone flooring 20mm thick marble stone with black or of specified colour topping including filling the gaps with cement marble chips mix in proportion of 4 : 7 (4cement : 7 white black or white or black marble chips) size from 1mm to 4mm by volume and under layer of 25mm thick cement concrete [1:2:4, graded stone aggregate 12.5mm nominal size] rubbing and polishing and cement slurry etc. complete :In ordinary cement.
39Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).Grade 304
40Providing and fixing steel gate, grating , and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide
41Providing and installation of Poly Carbonate Sheet roofing over existing steel framing as per drawing and design including fixing with non-corrodible nuts and water proof washers as per instruction of Engineer-in-charge. 10 mm thick
42P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580x440mm.
43P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 550 mm x 400 mm dia for counter top
441.0mm thick stainless steel AISI-304& IS 13983-1994 kitchensinkofapprovedmakeasperEngineer-in-chargewith large waste coupling.37 x 18 x 7 17x15x7 (with drain board)
45P & F Bottle Trap of approved make : C.P Brass 32 mm
46P&FlstqualityWVCUrinal (IS:2556mark)with25mmdia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back (large) or half stall size 610x400x80mm.
47P&FC.P.brassUrinalSpreader forstallurinalofapproved make.
48P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm. Makrana II quality marble having light spots
49P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: WVC with C.P. brass bend. PVC with PVC bend as per IS : 7231
50P & F Square-mouth gully trap `A` grade (IS 651-1992 :marked) of approved make complete with C.I. grating, frame & Cover masonary chamber in C.M. 1:6, 100mm thick C.C. 1:5:10 base concrete, 40mm thick C.C.M-15 grade coping, 12mm thick cement plaster in CM 1:3 complete as per approved design & type.Trap size 150 X 100mm, ferrow cement cover with frame, Internal Chamber size 300 X 300mm.
51Construction of chamber in all type of soil with 300 mm thick masonry in CM 1:6 m,10 cm thick C.C. 1:5:10 in foundation, 20mm thick insider plaster in Cm 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring , earthwork etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.
52Inside size size 450 x 450mm depth upto 0.5 M Cement cover with frame
53Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering, jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth work etc . complete including disposal of surplus earth within a lead of 50 mtr . Inner dia 90 Cm & 10 to 12 Mtr deep.
54Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M 15 grade C.C floor & RCC slab covering with M15 grade c.c. floor, 50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cement cover with frame, earth work etc. complete as per approved drawing including disposal of surplus earthwithin a lead of 50 mtr:- Size 230 x110 x150 cm.(for 20 users) with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect.
55Construction of open Drain with 112mm thick brick masonry in CM 1:4 Semi circular S.W. glazed channel (confirming to IS Standards) fixed with cement mortar 1:1 over a bed of 100mm thick C.C. 1:5:10, filling of edged with M-15 grade C.C. flooring, 12mm cement plaster 1:4, over all exposed faces, excavation & disposal of earth with in a lead of 50 mtrcomplete as per approved drawings : 250 mm drain,225mm Av. depth width 25 Cm S.W. glazed channel.
56Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
5720 mm nominal size
5825 mm nominal size
5932 mm nominal size
6040 mm nominal size
61P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make :
62Gun-metal 25 mm nominal bore.
63Gun-metal 40 mm nominal bore.
64P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 .) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant.
6575 mm dia
66110 mm dia
67160 mm dia
68P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cement rubber ring and lubricant:
69Coupler(socket)
7075mm dia
71110mm dia
72Bend 45
7375mm dia
74110mm dia
75Bend 87.5
7675mm dia
77110mm dia
78Door 'Y'
7975mm dia
80110mm dia
81Socket Plug
8275mm dia
83110mm dia
84Door Bend (Left & Right)
8575mm dia
86110mm dia
87Reducer 110 X 75 mm
8875mm dia
89110mm dia
90Door Cap
9175mm dia
92110mm dia
93Double 'Y'
9475mm dia
95110mm dia
96Vent Cowel
97110mm dia
98Nahni Trap with Jali 4”
99110mm dia
100Pipe Clip
10175mm dia
102110mm dia
103P&FPVCStorageTank ISIMarked(IS:12701) indicating theBISlicenseNo), ofapprovedmakewithcover,25mmdia 1MlongG.I. over-flowpipe&25Cm. longwashout pipe with plug & socket, including making connection etc., complete of approved design:
104500 litres capacity.
105Providing and fixing following Superior quality CP Brass fittings of approved make as per direction of Engineer-in-charge
106Pillar Cock 15 mm nominal size
107Long body Bib Cock 15 mm nominal size
108Angular stop cock with long thread 15 mm nominal size
109Soap dish
110Paper holder
111Health focet (Premium heavy Quality) as approved by Engineer-in-Charge
112P & F Grating of approved quality/make:Stainless Steel Sheet size 125mmdia. Heavy Quality of approved make
113P & F 15 mm. Dia Connection Pipe of approved quality/make :PVC pipe with C.P. Brass nuts upto length 450mm.
114P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers. Size 600 x 450mm x 4 mm thick
115Providing,Laying&JointingR.C.C.classNP-2Non-Pressure pipes (IS: 458mark)of approved make with collars, jointed with C.M.1:2 or having Spigotand socket ends with flexible rubber rings joint including testing of joints etc. complete :
116150mm dia Internal
117Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07
118Short point (up to 3 mtr.)
119Medium point (up to 6 mtr.)
120Long point (up to 10 mtr..)
121Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419-1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07
122ON Board
123Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires.
1243x 1.5 sq.mm (For Extra Point Wiring)
1252 x 2.5 sq. mm. + 1x1.5sqmm (For Light & emergency circuit)
1262 x 4.0 sq. mm. + 1 x 2.5 sq. mm. (For Power & AC Circuit)
1274 x 6.0 sq.mm (For Sub Mains)
1281 x 4.0 sq.mm (For Earthing)
129P & F P.V.C. sheet 2.0 mm thick of following size Including screws, cup washer as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 100 mm dia.
130Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item.
131S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required.
13225 mm
13332 mm
134Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
135Single pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating
136Double pole MCB(With B/C curve tripping Characteristics) 50/63 A rating
137Four pole MCB (With B/C curve tripping Characteristics)
13850/63 A rating
139Providing & Fixing of 240/415 V factory fitted RCBO with overload, short-circuit and earth leakage protection with ISI marked (IS12640-2)/ conforming to IEC 61009-1, breaking capacity 10 KA, provision for pad lock, min. Electrical operation 10,000 upto 63 A rating , minimum phase termination capacity of 35sq.mm. , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.Two pole 100/300mA sensitivity 6A-32 A rating
140Providing & Fixing of Recessed/surface mounting heavy dutyhorizontal typeDoubleDoor (Metal /Glazed)DistributionboardwithMetalendboxmadeout fromGalvanizedsteel /CRCAsheetnot less then1.2mmthick conforming to IS-8623-1&3 / IEC61439-1&3,powderpaintedcompletewithreversibledoor (fordoubledoorDBonly)100amp. insulatedcopperbusbar/shortinglink , copper neutral link, copper earth link , color codedinterconnectingwire set of suitable rating anddinbar,maskingsheet, makinginternalDB terminationswithcopperlugs,Ferrules,detachableglandplate,includingmakingconnections,testingetc.asrequired.OEMshallhavesubmitNABL/CPRI/ERDAaccrediatedlabtypetestreports&AllasperpreapprovedbyEngineerincharge.Foradditionaltechnicalparametersofproduct/workreferAnnexure 'A' attached with this BSR Metal door (Three phase) IK-09 and IP-43 with Metal end box 4 Way
141Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.
1421170mm(+/-10%) LED batten with min. lumen output 2200 lm
143Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulb in existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70, minimum life time of minimum 25000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge.
14415 Watt
145Providing & Fixing of ISI marked (IS:1258) batten/angle lamp holder with CM/L no. printed and made out from industrial grade Polycarbonate or fire resistant ABS material, brass terminal & captive screwsincluding making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
146Water Cooler: Providing and Installation of Water Cooler for storage capacity 500 liters made of 22 SWG SS Sheet, Inner body made of 22 SWG SS Sheet, Puff Insulation 75 mm with MS Fram work Compressor Unit, Fitted on Bottom, compressor & Power Consumption 2 K.W. including 3 nos. of faucets to be placed on a 0.45 meter raised surface, Blue Star or equivalent make complete in all respect e.g. electrical, water fitting, etc. as per Direction of Engineer in charge .
147Providing and Fixing Cast iron Benches of size 1500 x 500 mm-1800x600mm approx with iron Rectangular tube battens on top and back rest of iron Rectangular tube battens on cast iron members and rest on 150 mm thick P.C.C. (1:2:4) as per design and drawing in all respect as per directed by Engineer In charge. (Photograph/ Drawing Attached)
148SITC of all in one Solar LED street light fixturewith integrated high monocrystalline panel with lithium (LIFEP04) ferro phosphate battery with BIS approved make, Iluminaire should be secondary optic lenses for better distribution with delivered efficiency of >100 Lumen per watt. Manufacturer shall have in house R&D Laboratory duly recognised by Ministry of Science and Technology, Govt of India/ NABL. Manufacturer shall have inhouse pole and Luminire manufacturing facility. Luminaire can be supplied with hybrid switch along with indicator to under stand the source of power (either from Solar or AC Supply) shall have certificate tested from MNRE approved Lab. Guarantee for total system will be two years. Compact solar LED street light- Solar Panel Max- 60W (Mono) 18V, Battery capacity- 14.8V 36AH, LED Light- 60W, 100wp module. It includes SITC of GI pole dia 75mm, Pole should be hot dip galvanised class B 80 micron, total height of pole should be 6 mtr all as approved by EIC. Note- all the above should be integrated and should be one system Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57771017
AUTHORITY Government Departments
TENDER VALUE 19.16 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Rajasthan Tourism Development Corporation Limited
Work Description Tender for Development Works At Shakambhari Mata Temple ,Sambhar (Rajasthan).
Basic Detail
Tender No NIT no 08 2439 dated 28-09-2026
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 29 Sep 2026
Submission Date 14 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 19.16 Lakhs
Tender Fee 1000
EMD 38320
Exemption Not Available
Document List
78229693-20dc-4ced-bfb2-2860cc2f3f25.html
BOQ_1066488.xls
Sambhar.pdf
Tendernotice_1 (79).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
html

78229693-20dc-4ced-bfb2-2860cc2f3f25.html

xls

BOQ_1066488.xls

pdf

Sambhar.pdf

pdf

Tendernotice_1 (79).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender