Tender For Augmentation Of Infrastructure At Saw Mill Mankhurd At Nd (Mbi)
Tender Overview
Project Description
Tender for Augmentation Of Infrastructure At Saw Mill Mankhurd At Nd (Mbi)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 26-Oct-2026 | datecorrigendum | Date | 10-Nov-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CE (DGNP) MUMBAI Name of Work: AUGMENTATION OF INFRASTRUCTURE AT SAW MILL MANKHURD AT ND (MBI) Contract No: CA No: DDG & CE(MB)/TEMP-03 of 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | LIST OF WORKS (Schedule A Part I to Part XVII) |
| 3 | Total amount of Sch 'A' Part-I (Building Works) brought forwarded from sl page No 27 . |
| 4 | Total amount of Sch 'A' Part-II (Internal Electrification) brought forwarded from sl page No 33 . |
| 5 | Total amount of Sch 'A' Part-III (Internal Water supply) brought forwarded from sl page No 35 . |
| 6 | Total amount of Sch 'A' Part-IV (External water supply) brought forwarded from sl page No 36 . |
| 7 | Total amount of Sch 'A' Part-V (External Electric supply ) brought forwarded from sl page No 44. |
| 8 | Total amount of Sch 'A' Part-VI (Sewage Disposal) brought forwarded from sl page No 46 . |
| 9 | Total amount of Sch 'A' Part-VII (Area Drainage) brought forwarded from sl page No 47. |
| 10 | Total amount of Sch 'A' part- VIII (Fire fighting system) brought forwarded from sl page No 59. |
| 11 | Total amount of Sch 'A' part- IX (Fire Alarm) brought forwarded from sl page No 63. |
| 12 | Total amount of Sch 'A' part- X (Cooling appliances) brought forwarded from sl page No 64. |
| 13 | Total amount of Sch 'A' part- XI (Lift) brought forwarded from sl page No 67. |
| 14 | Total amount of Sch 'A' part- XII (Air conditioning ) brought forwarded from sl page No 68. |
| 15 | Total amount of Sch 'A' part- XIII (Lighting protection system) brought forwarded from sl page No 69. |
| 16 | Total amount of Sch 'A' part- XIV (Road,Path & Culverts) brought forwarded from sl page No 72. |
| 17 | Total amount of Sch 'A' part- XV (EOT Crane) brought forwarded from sl page No 73. |
| 18 | Total amount of Sch 'A' part- XVI (Demolition & Dismantling) brought forwarded from sl page No 74. |
| 19 | Total amount of Sch 'A' part- XVII (Excavation and Earth Work) brought forwarded from sl page No 75. |
| 20 | Subtotal |
| 21 | Sch 'A' Part- XVIII (MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as \\"Rs. 0.00\\" under Col.5 signifies this fact only. |
| 22 | INTERNAL ELECTRIFICATION |
| 23 | S & F surface mounted circular downlight with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1500 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 13.5W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, IEC Safety Class I, and suitable for 220- 240V input voltage, 50Hz line frequency, ambient temperature range 0 to 45 °C and fixture height ≤ 60mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify SM296C LED15S-6500 PSU WHNOTES:[i] The Contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory. |
| 24 | S & F surface mounted circular downlight with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1200 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 11W, power consumption tolerance ±10%, initial correlated colour temperature (CCT) 4000K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5kV, etc. with pressure die-cast aluminium housing, polycarbonate diffuser, steel clip (spring), IP20 & IK02 protection, IEC Safety Class I, and suitable for 220- 240V input voltage, 50Hz line frequency, ambient temperature range 0 to 45 °C and fixture height ≤ 60mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify SM296C LED12S-4000 PSU WHNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory. |
| 25 | S & F industrial batten designed to provide flicker free, consistent light output with integral fixed output driver, LED light engine source having 120° beam angle, 120° luminaire light beam spread, 4000 lm luminous flux, power consumption ≤ 34W, rated nominal luminous efficacy ≥ 120 lm/W, colour rendering index (CRI) > 80, correlated colour temperature (CCT) 6500K, Power Factor ≥ 0.95, initial chromaticity < 5, median useful life L70B50 @ Ta = 45°C ≥ 50000hrs, surge protection level until 4kV differential mode and 4kV common mode with steel housing, polycarbonate optical cover, surface & suspended (asymmetric / symmetric) mounting device, IP20 & IK02 protection, IEC Safety class I, suitable for 140- 270V input voltage, 50Hz line frequency, ambient temperature range 0 to 45 °C along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify BN308C LED40S-6500 L120 PSU WHNOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory. |
| 26 | S & F high bay luminaire offering excellent beam and glare control & suitable for indoor industrial environment with integral fixed output driver, LED light engine source having 55° beam angle, 110° luminaire light beam spread, 10000 lm luminous flux, power consumption ≤ 80W, rated nominal luminous efficacy ≥ 125 lm/W, colour rendering index (CRI) ≥ 80, correlated colour temperature (CCT) 6500K, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000hrs, surge protection level until 4kV differential mode and 4kV common mode with aluminium pressure die cast housing, polycarbonate optical cover, eye-bolt mounting device of pressure die cast aluminium, IP66 & IK08 protection, IEC Safety class I, suitable for 120- 277V input voltage, 50Hz line frequency, ambient temperature range 0 to 45°C along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify BY325P LED100S CW PSU GR FG WB XTFCL V1NOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory. |
| 27 | S & F high bay luminaire offering excellent beam and glare control & suitable for indoor industrial environment with integral fixed output driver, LED light engine source having 55° beam angle, 110° luminaire light beam spread, 10000 lm luminous flux, power consumption ≤ 160W, rated nominal luminous efficacy ≥ 125 lm/W, colour rendering index (CRI) ≥ 80, correlated colour temperature (CCT) 6500K, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000hrs, surge protection level until 4kV differential mode and 4kV common mode with aluminium pressure die cast housing, polycarbonate optical cover, eye-bolt mounting device of pressure die cast aluminium, IP66 & IK08 protection, IEC Safety class I, suitable for 120- 277V input voltage, 50Hz line frequency, ambient temperature range 0 to 45°C along with all necessary accessories complete all as specified and directed by the engineer-in-charge.Make: Signify BY325P LED195S CW PSU GR FG WB XTFCL V1NOTES:[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory. |
| 28 | S & F 3-star (EEL) T-shape lamp of capacity of 10W capable delivering 1000 lumen having luminous efficacy of > 100 lm/W, starting time < 0.5 s, CRI > 80, CCT 6500K, PF >0.9, input voltage range 140- 270 V, input frequency 50- 60 Hz and B22 socket complete all as specified and directed by the engineer-in-charge. Make: Philips Stellar Bright LED T-Bulb or equivalent model of Crompton, Wipro, Bajaj |
| 29 | S & F LED security light having LED light source engine, integral driver, 2400 lm luminous flux, 120 lm/W luminous efficacy, correlated colour temperature 5700K, colour rendering index (CRI) > 70, power consumption ≤ 25W, power factor ≥ 0.95, surge protection 4/4 kV, safety class I, median useful life L70B50 @ 50000 hrs, IP 66 & IK 02 protection, aluminium pressure die cast housing, polycarbonate optical cover, spigot for diameter 34 mm to 42 mm, symmetric wide outdoor distribution, suitable for input voltage 140- 270 V and line frequency 50 Hz including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete in all respect as specified and directed by engineer-in-charge.Make: Signify BRP330 LED24 CW R5N PC PSU S1 or equivalent model of iGuzzini, Trilux or ENDO Lighting[i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.[ii] The standard warranty of the light fitting shall be of 5 years. |
| 30 | M & L for GI fan box having a steel hook in the middle to provide secure mounting to ceiling fan and multiple (not less than 6) knockouts of size not less than 20 mm NB to extend the wiring in any direction, embedded in the ceiling, including making good of disturbed surface of ceiling all complete as specified in IS 732: 2019 and directed by engineer-in-charge. |
| 31 | S & F 8 module factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure having zinc coating not less than 120 GSM,conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed by the engineer-in-charge. Make: Legrand Myrius 6890 42 or equivalent model of Havells or Anchor Roma |
| 32 | M & L modular type 25 A 1-way SP switch with indicator conforming to IS 3854: 2012 with finger-proof terminal complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Make: Legrand Arteor 5734 17 or equivalent model of Schneider, MK Electric by Honeywell |
| 33 | S & F modular type 3 pin 25A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Make: Legrand Arteor 5734 17 or equivalent model of Schneider, MK Electric by Honeywell |
| 34 | S & F wall-mounted industrial socket protected by disconnect fuse carriers having housing made of self-extinguishing polymer in RAL 7035 colour, stainless steel external pins & screws, resistance to fire and abnormal heat conforming to IEC 60695-2-11 (glow wire test @ 750 °C), fuse holder conforming to IEC 60269, door to accede to the fuse holder equipped with key-lock and opened only with the (externally padlocked into position \\"0\\" and \\"1\\") switch in position “0”, DIN rail, etc., with IP65 & IK09 protection, cable entry from the top, complete with fair-lead for 25 mm NB max. diameter cables and PG21 cable gland, construction conforming to IEC 60309-2-4, captive screw connection terminals along with all necessary accessories complete all as specified and directed by the engineer-in-charge. |
| 35 | 3P + N + E, 20A wall-mounted socket protected by fuse carriers with DIN rail suitable for 3-Ph, 415V input voltage, 50Hz line frequency.Make: Legrand Ekinox³ P-17 5078 63 or equivalent model of Schneider, MK Electric by Honeywell |
| 36 | 3P + N + E, 40A wall-mounted socket protected by fuse carriers with DIN rail suitable for 3-Ph, 415V input voltage, 50Hz line frequency.Make: Legrand Ekinox³ P-17 5078 62 or equivalent model of Schneider, MK Electric by Honeywell. |
| 37 | 3P + N + E, 63A wall-mounted socket protected by fuse carriers with DIN rail suitable for 3-Ph, 415V input voltage, 50Hz line frequency.Make: Legrand Ekinox³ P-17 5078 64 or equivalent model of Schneider, MK Electric by Honeywell |
| 38 | S & F triple pole & neutral double door, modular type, double door, per phase isolation metallic distribution board conforming to IS/IEC 61439-1 & 3, suitable for flush / surface mounting having reversible door, cassette type removable chassis, neutral bar with isolated cover, insulated phase busbars, earthing bar, interconnecting FRLS wire set, door earthing, EPDM gasket, DB identification label, field fitted lock provision, IK 09 & IP 43 protection with provision for modular (4P MCB / Isolator) or 3P/4P MCCB (up to 100A) incomer, 2P RCCB / RCBO sub-incomer and 1P MCBs outgoing, cable ties for cable management, pre fitted masking sheet, cement spill protector, full length plastering guide on all four sides for depth guidance & alignment convenience etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 39 | triple pole & neutral double door PPI DB, 4 wayMake: Legrand Ekinox 5076 70 with PPI kit 5079 44 or equivalent model of ABB, Schneider, Siemens |
| 40 | triple pole & neutral double door PPI DB, 6 wayMake: Legrand Ekinox 5076 71 with PPI kit 5079 45 or equivalent model of ABB, Schneider, Siemens |
| 41 | triple pole & neutral double door PPI DB, 8 wayMake: Legrand Ekinox 5076 72 with PPI kit 5079 46 or equivalent model of ABB, Schneider, Siemens |
| 42 | triple pole & neutral double door PPI DB, 12 wayMake: Legrand Ekinox 5076 73 with PPI kit 5079 47 or equivalent model of ABB, Schneider, Siemens |
| 43 | NOTES:[i] RCCB, RCBO, Isolator, MCB & MCCB shall be measured and paid separately.[ii] Field fitted lock shall be measured and paid separately. |
| 44 | S & F vertical triple pole & neutral double door, modular type, double door, per phase isolation metallic distribution board conforming to IS/IEC 61439-1 & 3, suitable for flush / surface mounting having reversible door, cassette type removable chassis, neutral bar with isolated cover, insulated phase busbars, earthing bar, interconnecting FRLS wire set, door earthing, EPDM gasket, DB identification label, field fitted lock provision, IK 09 & IP 43 protection with provision for 3P / 4P MCCB incomer, and 3P / 1P MCBs outgoing, 25kA short-circuit current withstand capacity for 500 ms, secure connections with fixed spreader links, cable ties for cable management, pre fitted masking sheet, cement spill protector, full length plastering guide on all four sides for depth guidance & alignment convenience, knockouts of 50mm or higher dia. etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. |
| 45 | vertical triple pole & neutral double door DB, 4 wayMake: Legrand Ekinox³ 5077 45 or equivalent model of ABB, L&T or Schneider |
| 46 | vertical triple pole & neutral double door DB, 8 wayMake: Legrand Ekinox³ 5077 47 or equivalent model of ABB, L&T or Schneider |
| 47 | vertical triple pole & neutral double door DB, 12 wayMake: Legrand Ekinox³ 5077 48 or equivalent model of ABB, L&T or Schneider |
| 48 | NOTES:[i] MCCB & MCB shall be measured and paid separately.[ii] Field fitted lock shall be measured and paid separately. |
| 49 | S & F moulded case circuit breaker (MCCB), four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge. |
| 50 | 40 A, 415V, 25 kA, 50 Hz 4P MCCB Make: Legrand DX³ 4200 52 or equivalent model of ABB, L&T or Schneider |
| 51 | 80 A, 415V, 25 kA, 50 Hz 4P MCCBMake: Legrand DX³ 4200 54 or equivalent model of ABB, L&T or Schneider |
| 52 | 100 A, 415V, 36 kA, 50 Hz 4P MCCBMake: Legrand DX³ 4200 54 or equivalent model of ABB, L&T or Schneider |
| 53 | 250 A, 415V, 36 kA, 50 Hz 4P MCCBMake: Legrand DX³ 4202 19 or equivalent model of ABB, L&T or Schneider |
| 54 | INTERNAL WATER SUPPLY |
| 55 | Supply & fixing of two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35041PMGE or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge |
| 56 | Supply & fixing of Pillar Cock (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35001PMG or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge |
| 57 | Supply and fixing Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves Make - Jaquar Model No KUP-35053PM or equivalent complete all as specified and directed. |
| 58 | Supply, Fixing in position of 100 mm dia. heavy PVC Nahani Trap with SS cockroach trap with 150mm dia SS grating including constructing necessary brick masonry etc., complete as per drawings and directions.(Approved Make: Astral/Supreme/Prince or approved equivalent.) |
| 59 | Providing and fixing Square Mouth PVC gully trap of grade 'A' complete with C.I. grating embedded in brick masonry chamber with first class bricks in CM 1:5 and trap to be set in cement concrete 1:2:4, both side 12mm thick plastering with floating coat of neat cement, making necessary connections and providing water tight double seal FRP Heavy duty cover with frame of 300 x 300 mm internal size. The rate also includes necessary excavation (mechanically / manually) to the required depth, dewatering, backfilling earth in exposed side, watering, ramming and removing the surplus excavated material and making good the same etc. complete as directed by Engineer-in-charge.600 x 600 mm chamber with 230 x 160 mm size `P’ trapFRP Cover Make: Thermodrain / Fibrocast / Sintex |
| 60 | EXTERNAL ELECTRIC SUPPLY |
| 61 | M & L perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete including cable tray supports and associated accessories, all as specified and directed by the engineer-in-charge.Make: Elcon, Indiana, OBO |
| 62 | 150 mm X 50 mm X 1.6 mm |
| 63 | 300 mm X 75 mm X 2.0 mm |
| 64 | 375 mm X 75 mm X 2.0 mm |
| 65 | 450 mm X 75 mm X 2.0 mm |
| 66 | Supply, installation, testing and commissioning of totally type tested (TTA) LV switchboard of suitable size, made out of CRCA steel sheet of minimum 2.0 mm thickness with all necessary wiring, fully compartrmentalized, bolted & modular design conformning to IEC 61439-1 & 2, doors hinged on either side offering greater fiexibility to configure the panel as per site conditions, up to Form 4b separation, locking arrangement, design verification tested and certified by an STL full member organization, arc fault containment of prospective short-circuit current up to 100 kA for 0.4 duration as per the criteria 1 to 7 of IEC TR 61641. CI 3C2 Corrosion resistance conforming to IEC 60721-3-3, degree protection up to IP 54 conforming to IEC 60529, electromagnetic compatibility (EMC) as per IEC 61000-X-X standards, suitable for 3-Phase power supply having rated frequency 50 Hz, rated operating voltage Ue up to 690 V, rated insulation voltage Ui up to 1000 V. rated impulse withstand voltage Uimp up up to 12 kV, overvoltage category up to IV, rated current le up to 7000 A for main busbar & up to 3200 A for distribution busbar, rated peak withstand current Ipk up to 220 KA, rated short-time withstand current Icw up to 100 KA rms (1 s), degree of pollution 3 conforming to IEC 60664-1, IACSE10(b) (7) vibration test performance conforming to IEC 60068-2-6, seismic performance conforming to IEEE 693, operating temperature from -5 to 50°C, suppoted and fixed on structural frame of angle iron of suitable |size including earthing stud, labelling, painting to all internal and external exposed steel surfaces with powder coating paint through 7 tank process, duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour complete all as specified and directed by the engineer-in-charge. |
| 67 | NOTES:(i) The busbars shall be of double deck arrangement for rating ≥ 1600A interleaved /non-interleaved design as per OEM. ACBs shall have separately powered, individual fault tip indication LEDs (For overload, short circuit, eath fault and trip-unit failure) shall be available on the trip unit which shall functíon even in the absence of external power supply to the breaker.ACB shall be suitable for ZSI. Trip units shall have thermal memeory as standard. (iii) All the MCCBs Up to 250Ashall be with thermal magnetic trip unit & above 260A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs / MCCBs), it shall be supplied with continuous rated shunt trip coils. (iv) Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. (V) The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. (Vi) All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure- horizontal & vertical) of the Panel shall be supplied by the OEM.(vii) The Contractor shall furnish dimensional drawings of the iterns offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval. (viii) The Contractor shal intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative norninated by the Engineer-in-Charge before dispatch .- 04# |
| 68 | MAIN LT PANEL- M.L.TP The MAIN LT PANEL- M.L.T.P shall comprise of the following: [A] BUSBAR CHAMBER (i) Set (3L + N) of copper busbar of rated capacity 1000A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01#(B) INCOMING(i) Circuit Breaker(i) 800AA 415V lcs = 100% Icu = lcw (1sec for total selectivity) = 50kA,50 Hz electrical draw-out type 4P ACB, conforming to IS/IEC 60947-2 &3, having 100% neutral with inbuilt release protection, no derating up to 50 °C, microprocessor based trip & LED based display systems with thermal memory providing overload, short-circuit, instantaneous & earth-fault protection, zone selective interlocking. pre-trip alarm & individual fault indicating LEDs, 20 trip record, % loading, bar graph, max. & min, meter and pre-alarm function for overload, short-circuit & earth |fault - 01 Nos.(ii) lnstrumentation & Measurement(a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, WNA, WhNAh, Runhrs. Onhrs & interupts- 01# (b) 800/1A CI. 1.0 C.T. with 15 VA burden- 01#(iii) Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01# (b) LED status indicators (ON, OFF, TRIP)- 01# (c) LED trip indicators (SC, SP, TP)- 01# (d) 6A, 10KA, 415V, 50 Hz 4P MCB- 01# |
| 69 | [C] OUTGOING (i) Circuít Breaker (a) 250 A, 415 V, lcs = 100% lcu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting. etc.- 03# adjustable short-circuit setting, front indication LEDs, (b) 200 A, 415 V, lcs = 100% lcu = 25 kA, 50 Hz 4P MCCB, Conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload seting. |adjustable short-circuit setting, front indication LEDs, etc.- 01# (c) 100 A, 415 V, lcs = 100% lcu = 25 KA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting. adjustable short-circuit setting, front indication LEDs, etc 04 #(d) 80A415Vlc8= 100% lcu = 25kA,50 Hz4P MCCB.conforming o 1EC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload adjustable short-circuit setting, front indication LEDs, etc.- 01#(e) 63 A, 415 V, lcs = 100% lcu = 25 KA, 50 Hz 4P MCCB, conforming to IEC setting. 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting. adjustable short-circuit setting, front indication LEDs, etc.- 03#(f) 40 A 415 V, Ics = 100% lcu = 25 KA, 50 Hz 4PI 60947-2: 2016, having themal magnetic trip unit, adjustable overload seting. MCCB, conforming to IEC adjustable short-circuit setting, front indication LEDs, etc. -02# (i) Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 14# |
| 70 | M&L for 1.1 KV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per CI. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 71 | 4 core 6 mm2, 2XWY |
| 72 | 4 core 10 mm2, 2XWY |
| 73 | 4 core 16 mm2, 2XWY |
| 74 | FIRE FIGHTING SYSTEM |
| 75 | Supply, installation, testing and commissioning of totally type tested (TTA) LV switchboard (Fire MCC) of suitable size, made out of CRCA steel sheet of minimnum 2.0 mm thickness with all necessary wiring, fully compartment alized, bolted & modular design conforming to IEC 61439-1&2, doors hinged on either side offering greater flexibility to confiqure the panel as per site conditions, up to Form 4b separation, locking arrangenent, design verification tested and certified by an STL full member organization, arc fault containment of prospective short-circuit Current up to 100 kA for 0.4 s duration as per the criteria 1 to 7 of IEC TR 61641, CI. 3C2 corrosion resistance conforming to IEC |60721-3-3, degree protection up to IP 54 conforming to IEC 60529, electromagnetic compatibility (EMC) as per IEC 61000-x-x standards, suitable for 3-Phase power supply having rated frequency 50 Hz, rated operating voltage Ue up to 690 V, rated insulation voltage Ui up to 1000 V, rated impulse withstand voltage Uimp up to 12 kV, overvoltage category up to V, rated current le up to 7O00 A for main busbar & up to 3200 A for distribution busbar, rated peak withstand current Ipk up to 220 kA, Tated short-time withstand curent lcw up to 100 kA rms (1 s), degree of pollution 3 conforming to IEC 60664-1, IACSEIO(b)(7) vibration test performance conforming to IEC 60068-2-6, seismic performance conforming to lEEE 693, operating tenperature from -5 to 50°C, |supported and fixed on structural frame of angle iron of suitable size including earthing stud, labelling, painting to all internal arnd external exposed steel surfaces with powder coating paint through 7 tank process, duly fixed in ground with PCC foundation (1:2:4) type Bl with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour complete all as specified and directed by engineer- in- charge.The MCC shall comprise of the following: |
| 76 | [A] BUSBAR CHAMBER[i] Set (3L + N) of copper busbar of rated capacity 320 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 1#[B] INCOMING[i] Circuit Breaker(a) 250 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 01# [ii] Instrumentation & Measurement(a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01#(b) 250/1A Cl. 1.0 C.T. with 15 VA burden- 01#(c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01#[iii] Indication & Annunciation(a) LED phase indicators (Red, Yellow, Blue)- 01 Set(b) LED status indicators (ON, OFF, TRIP)- 01 Set[C] OUTGOING[i] Circuit Breaker(a) 160 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz, 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 03#(b) 40 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 05#(c) 32 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 03# with all accessories and wiring etc.- 02# |
| 77 | [ii] Motor Starter / Drive(a) Fully automatic digital soft starter suitable for Electric driven main fire pump drive having adaptive acceleration control, built-in RTD & thermistor inputs, programmable auto start/stop, emergency run operation, fully programmable overload trip, etc. complete with contactors, push button, LED type indicators, auto/manual selector switch, current sensing type single phase preventer complete.(b) Fully automatic DOL starter, suitable for Electric driven pressurization pump (Jockey Pump) motor, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 02#(c) Fully automatic DOL starter, suitable for Electric driven Booster Pump motor, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.- 03# |
| 78 | M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge. |
| 79 | 2 core, 2.5 mm² (for instrumentation) |
| 80 | 3 core, 2.5 mm² (for auto start/stop panel) |
| 81 | 12 core, 2.5 mm² (for diesel engine pump) |
| 82 | M & L for 1.1 KV grade fire survival cable with fire rating FS (950/FWS) conforming to IS 17505-1: 2021, and having electrolytic annealed plain / tinned copper (Class 1/2) conductor conforming to IS 8130: 2013, mica tape layer (s) primary insulation, cross linked PE (XLPE) / cross linked HFFR secondary insulation, thermoplastic HFFR inner sheath, glass fibre heat barrier tape, galvanized round wire armour, thermoplastic HFFR (HFS-TP 90) / Cross Linked HFFR (HSF-XL 90) outer sheath including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 83 | 3 core, 95 mm² FS (950/FWS) Cable |
| 84 | 3 core, 6 mm² FS (950/FWS) Cable |
| 85 | S & F of perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete including cable tray supports supports and associated accessories, all as specified and directed by the engineer-in-charge. |
| 86 | 300 mm X 50 mm X 1.6 mm |
| 87 | 150 mm X 50 mm X 1.6 mm |
| 88 | 100 mm X 50 mm X 1.6 mm |
| 89 | M & L for PN 1.6 rated 200 mm NB polypropylene Vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed by the engineer-in-charge. |
| 90 | M & L for FM approved and UL listed, PN 1.6 rated lever operated, wafer type CI Butterfly valve, conforming to IS 13095: 1991,fitted with visual indicator & temper switch, having Cast iron (CI) body with ductile iron EPDM coated disc, SS431 stub shaft, PTFE bushing, flange drilling standard end connection conforming to IS: 1538- 1993 along with necessary accessories complete as specified and directed by the engineer-in-charge (for Zone control valve assembly). |
| 91 | 150 mm NB |
| 92 | 100 mm NB |
| 93 | M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (Test and Drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed by the engineer-in-charge. |
| 94 | S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge. |
| 95 | Supply, installation, testing and commissioning of automatic air-vent valve with 20 mm end connections, brass body and cover, plastic float, brass cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 100 °C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed. |
| 96 | FIRE ALARM |
| 97 | Supply, installation, testing and commissioning of FM approved and UL listed Network Control Display (NCD) / Repeater Panel capable of full supervision of all inputs and network integrity, having 10\\" high definition 1024 X 600 colour touchscreen display, environmental adjustment controls to maximize LCD legibility, LED status indicators (for power supply and off normal condition), network connection, three USB connections, trouble relay, tamper and trouble inputs, etc. and features viz. network-wide acknowledge silence, reset, lamp test, fully programmable node-mapping subsystem, colour coded icon based event notification, event vectoring, etc. along with UL listed non-resettable 24 VDC power source complete all as specified and directed by the engineer-in-charge. |
| 98 | Supply, installation, testing and commissioning of FM approved & UL listed Remote power supply conforming to UL 864 & 1481 and NFPA 72 with integral battery charger capable of charging up to 18 Ah batteries to provide regulated and filtered 24 VDC power to notification appliance circuits, having power-supervision relay, fully regulated and filtered power output, AC trouble report selectable for immediate 2-hour delay, selectable earth fault detection, etc. complete all as specified and directed by engineer-in-charge. |
| 99 | M & L flame retardant, low smoke & low halogen fire alarm armoured cable having stranded class 2 copper conductor conforming to EN 60228, insulated with XLPE type GP8 conforming to BS 7655-1.3, extruded inner sheath with PVC conforming to BS 5467, armoured with galvanised steel round wire and sheathed with extruded FRPL PVC conforming to BS 5467, suitable for voltage rating 600/1000 V, maximum operation temperature 90 °C, maximum conductor temperature at short-circuit 250 °C, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. |
| 100 | 2 core, 1.5 mm² |
| 101 | 2 core, 2.5 mm² |
| 102 | Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. |
| 103 | Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge. |
| 104 | M & L for transparent FR PVC insulated, twin core copper conductor flexible Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. |
| 105 | S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. |
| 106 | S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. |
| 107 | S & F of 25 kg Chemical power trolley mounted fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. |
| 108 | S & F of 50 litre Compressed air foam trolley mounted type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand applicable on class A,B which involves flammable silds & liquids CAFS Fire Extinguisher with nominal charege of 50 ltr .Constructed of MS Sheet by mig wedding process and designed foam making cap complete all as specified and directed by the engineer-in-charge. |
| 109 | S & F 4 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge. |
| 110 | S & F of 3 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. |
| 111 | S & F of 9 litre Water / Stored pressure type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge. |
| 112 | Supply, installation, testing and commissioning of FM approved and UL listed addressable relay module to provide FACP a dry-contact output for activating a variety of auxiliary devices, viz. fans, dampers, control equipment, etc. having built-in type identification, integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dial entry of address, etc. complete all as specified and directed by engineer-in-charge. |
| 113 | S & F of Signage having size 300 mm X 150 mm reading \\"EXIT\\" in 12.5 mm block letters in Green and white background, self illuminated properly spaced to provide good legibility located directly in corridor near to each staircase and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level.These lights shall emit the maximum light required even during the electricity supply or in Black out period with high energy efficiency manufactured using superior quality Aluminium Extrusion body raw material.EXIT Signage shall meet the following technical / operational requirements:[i] Product Material: Alluminium ALLOY Extrusion[ii] Product Finish:- Matt Black / Snow white finish after phosphochromate treatment[iii] Wattage:- 5 Watt[iv] Mounting: Surface / Hanging |
| 114 | S & F of Signage having size of 500 mm X 500 mm, indicating the \\"Floor Number\\" in bold type and at 75 mm high numerals in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, posted and maintained within each stair enclosure on every floor, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level |
| 115 | S & F of Signage having size of 450 MM X 150 MM reading \\"FIRE EXTINGUISHER\\" in 12.5 mm block letters in White and Red background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,properly spaced to provide good legibility located directly in corridor near to each Manual call point/Fire Extinguisher and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level. |
| 116 | S & F of Signage having size of 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the \\"STAIRCASE\\" by an alphabetical letter in bold type and at 75 mm high letters in red and white background, made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board,securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level. |
| 117 | COOLING APPLIANCES |
| 118 | Supply, installation, testing and commissioning of 1-Phase mainline voltage stabilizer of 2 kVA rating having input voltage range 90 V to 300 V and output voltage range 180 V to 250 V and conforming to IS 8448: 1989, complete all as specified and directed by the engineer-in-charge. |
| 119 | LIFT & MISC |
| 120 | M & L for 4 core 10 mm2, 2XWY, 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 121 | M & L for 4 core 16 mm2, 2XWY, 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 122 | AIR CONDITIONING |
| 123 | S&F Voltage stablizer for automatic operation single phase naturally air cooled indoor type & disigned for input variation between 130V to 280V with output voltage stablizer at 230V with accuracy of +- 2.5% suitable for 2 Ton AC Model No VG500 of V-Guard or equivalent. |
| 124 | EOT CRANE |
| 125 | Design, manufacture and supply of 15.0 Ton capacity double girder electrically operated EOT crane along with 'VVVF' Drive control and conforming to the standards given in IS: 807/3177 and other relevant IS standards having span of 15.7 metres (±0.5 m), long travel of 60 mtr approx. and lifting height 10 m, bay 5 m (±0.5 m) with 10 & 5 Ton hook, complete all as specified and directed by the engineer-in-charge.The EOT crane shall be designed, manufactured, inspected, supplied, erected and successfully commissioned as per the following technical specifications:[i] Type of Crane: Double Box Girder EOT Crane[ii] Capacity: 15 Tons[iii] Span: 15.7 metre[iv] Height of Lift: 10 metre[v] Weight of Crane: 25 Ton[vi] Duty: Class II (M5) Heavy duty as per IS 3177 / IS 807[vii] Service: Indoor[viii] Operation: Push Button Pendant Operated[ix] Speed of C.T.: 10 metre / min ±5%[x] Speed of L.T.: 20 metre / min ±15%[xi] Speed of Hoisting: 5 metre / min ±5%[xii] Rope Dia.: 12 mm dia. Const. 6 X 36 UTS 180 kg/sq.mm Ungalvanised, with fibre core to give maximum tensile strength as per IS 226 (234 kN Br, Cap)[xiii] Power Supply: 415 V ±10%, 50 Hz ±3%, 3-Ph 4 Wire AC [xIv] Control Voltage: 110 V AC[xv] Ambient Temperature: 45 °C[xvi] Motor: Motors are squirrel cage induction motor with VWF drive crane duty with 40% CDF, Class B, B/F insulation |
| 126 | [xvii] Brakes: Main Hoist: 200 mm dia thrustor brake + EM brake (shoe type), Cross Travel: 100 mm dia thrust brake, Long travel: 100 mm dia * 2 nos thrustor brake.[xviii] Grear Boxes: Main Hoist: 3 H 550, Cross travel: 3 V 290, Long Travel: Double reduction.NOTE:[i] The scope includes testing of hoist at 125% load at manufacturers place. |
| 127 | M & L for 1.1 kV grade 4C, 16 SQMM, 2XWY Cable, fire survival cable, conforming to IS 17505-1: 2021, and having electrolytic annealed plain / tinned copper (Class 1/2) conductor conforming to IS 8130: 2013, mica tape layer (s) primary insulation, cross linked PE (XLPE) / cross linked HFFR secondary insulation, thermoplastic HFFR inner sheath, glass fibre heat barrier tape, galvanized round wire armour, thermoplastic HFFR (HFS-TP 90) / Cross Linked HFFR (HSF-XL 90) outer sheath including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. |
| 128 | S & F moulded case 100 A, 415V, 25 kA, 50 Hz 4P MCCB, circuit breaker (MCCB), in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge. |
| 129 | DEMOLITION & DISMANTLING |
| 130 | Taking down steel rollong shutter including frame of any size. |
| 131 | Removing old existing light fitting/florescent lamp/ high bay fittings or any Each type and handed over to user/Taken as schedule of credit as directed by Engineer-in- Charge. |
| 132 | Removing old existing exhaust fans and ceiling fan, wall mounted fan handed over to the user. |
| 133 | Removing old existing distribution board any type including accessories Eact and handed over to user/Taken as schedule of credit as directed by Engineer-in- Charge.. |
| 134 | Removing old existing LT panel any type including accessories and handed over to user/Taken as schedule of credit as directed by Engineer-in- Charge.. |
| 135 | Removing old existing Gl strips of any size and handed over to the user. |
| 136 | Disconnecting and taking down LT Cable various size. |
| 137 | ARBOURICULTURE |
| 138 | Preparing the ground surface by removing all vegetation, debris, stone etc and loosening / tiling the top layer of soil to a depth of 225mm including digging out unsuitable soil and remove the same to a distance not exceeding 50m replace the removed quantity of soil with approved suitable soil obtained from outside MD land and preparing combination of soil and manure spreading leveling so as to form a layer of 225mm average thickness complete all as specified and directed at site. |Note: Supply only additionly qunatity of approved soil and manure will be measured and paid separately. |
| 139 | Supply only suitable soil for lawn/bed/hedge etc as specified and directed. |
| 140 | M&L for brick edging along outer faces of mehendi hedge and flower bed complete all as specified. |
| 141 | Supply only manure (cow dung) for bed/lawn/hedge etc all as specified and Cum directed. |
| 142 | Development of the area by planting of mexicon grass with dibbling method by keeping the spacing of 30 cm between the tufts of grass including trenching the ground, watering rolling, moving (if required) and de-weeding completee all as specified and directed till the grass form a thick carpet free from weeds including the cost of labour, tools and tackles complete. |
| 143 | Supply and plantation of flowering bed with min 3Ocm spacing between the plants (with tantena plant) including preparation of flower beds by doing all horticulture activities like trenching, watering, de-weeding etc, including the cost of labour, tool and tackles complete for a period till flower plants become live properly and flower bed takes proper form complete in all respect all as specified. |
| 144 | All as per item above but the flowering hence with minimum 3 plants per sqm Sqm feet (feet tantena plant) 30cm wide along the inner face of mehendi. |
| 145 | Development and plantation of hedge (with mehendi plant) 30cm wide and 30cm high in two rows minimum 12 sticks per meter in a row including preparation of hedge beds by doing all horticulture activities like trenching, watering, de-weeding etc including the cost of labours,tools and tackles complete for a period hedges plants become live properly and hedge take proper form complete all as specified and directed. |
| 146 | Manning operation for maintenance of grass and flower beds for 6 months periods Months =6 x 30 = 180days |
| 147 | Maintenance of plants /hedges/ grass by weeding hosing saucer making once in Per every month for plants/ hedge once in every 15 days for carpet grass/ country day branches once in every week depositing the material at places as directed by Engineer-in-Charge and planting the new plants in place of dead plants of same species and height tuning with dods wherever required by replacing the dead patches of grass with the same grass as required without extra cost to the deptt and las directed complete for all above works |
| 148 | EXTERNAL WATER SUPPLY |
| 149 | Construction of brick masonary valve/hydrant pit of internal size 50 cm x 50 cm x 50 cm deep with mild steel sheet cover 3 mm thick and MS angle iron frame 50 mm x 50 mm x6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer incl excavation and earth work, 150mm thick PCC 1:4:8 type D2 as in foundetion, bick work in cement mortar,locking arrangement, and all inner side of pit shall be plastered 15 mm thick in cement mortar (1:4) and coping in 1:2:4 type B1 over brick wall complete all as specified and as directed. |
| 150 | Cutting existing steel tubing for alterations or additions and Screwing existing steel tubing for alterations or additions. |
| 151 | Subtotal Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender