Tender For Repairing Of Fire Hydrant And Fire Detection System At Aiims Bhubaneswar Satellite Center ,Balasore

Issued by Government Departments · Khordha, Odisha
Tender Value
16.08 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
18 days left
EMD
32169
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairing Of Fire Hydrant And Fire Detection System At Aiims Bhubaneswar Satellite Center ,Balasore

BOQ

Name of Work:- REPAIRING OF FIRE HYDRANT AND FIRE DETECTION SYSTEM AT AIIMS BHUBANESWAR SATELLITE CENTER ,BALASORE
Sl. No. Item Description
1Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. (i) Two Loop Panel (EDWARDS)
2Per Device Servicing
3Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required.
4Supplying, installation, testing & commissioning of addressable fire control module complete as required.
5Supplying, installation, testing & commissioning of addressable manual call point complete as required.
6Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required.
7Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.
8Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
9Providing and fixing in position industrial type pressure gauges with gun metal / brass valves complete etc. as required.
10Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
11150 mm dia
1280 mm dia
1350 mm dia
14Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
1580 mm dia
1650 mm dia
1760 HP Fire engine commossoning with C check (Make-Kirloskar)
18SITC of DG Battery (12 Volt, 180 Ah) with buyback
19Hydrent and Sprinkler system Commissoning with Jocky and Main Fire pump
20Providing, laying, testing & commissioning of 'C' class 80 mm dia heavy duty MS pipe conforming to IS 1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete.
21Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
22Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
23Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
24Supplying, fixing, testing & commissioning of 150 mm double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780.
25Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-incharge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately).
26Providing and fixing 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) with all accessories
27Painting (two or more coats) on rain water, soil waste and vent pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.(i) 150 mm diameter pipes
28Refilling of CO2 fire Extinguisher (4.5kg)
29Refilling of ABC Fire Extinguisher (6kg)
30Refilling of Clean Agent Fire Extinguisher (2kg) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57769961
AUTHORITY Government Departments
TENDER VALUE 16.08 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Tender for Repairing Of Fire Hydrant And Fire Detection System At Aiims Bhubaneswar Satellite Center ,Balasore
Basic Detail
Tender No AIIMS/BBSR/ENGG/ELECT/33/2026
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 29 Sep 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 16.08 Lakhs
Tender Fee Ref. Documents
EMD 32169
Exemption Not Available
Document List
33NIT.pdf
69090eb4-bb99-48e6-b2e4-37fa35b80ac9.html
BOQ_975393.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
pdf

33NIT.pdf

html

69090eb4-bb99-48e6-b2e4-37fa35b80ac9.html

xls

BOQ_975393.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders