Tender For Provn Of Certain Minor Work (Mw-05 And Mw-09) (E/M) At Air Force Station Barwala Under Age (I) Highground Chandigarh
Tender Value
3.42 Lakhs
Estimated cost
Bid Submission
20 Oct 2026
20 days left
EMD
6900
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Certain Minor Work (Mw-05 And Mw-09) (E/M) At Air Force Station Barwala Under Age (I) Highground Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc. 1.5 m wide and not exc 1.5 m deep in soft/loose soil) for laying of cables or GI pipe and getting out including levelling of bottom suface to required level complete all as specified and directed.Note : Excavation work of treanches should be done by labour. |
| 2 | Returning, filling in, includingspreading, levelling, watering and well ramming in layers not exc 25 cm. Complete all as specified and as directed. |
| 3 | Removing excavated material n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point. Complete all as specified and as directed. |
| 4 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 63 mm outer dia and 50 mm inner dia complete all as specified and as directed. |
| 5 | Supply, laying, jointing and commissioning in replacment LT underground cables XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade 2 core, cross sectional area 10 sq. mm with all fighting lugs, nuts and bolt etc. all as specified and as directed. |
| 6 | M&L for Point Flame proof wiring with 1.5 Sqmm single core unsheathed cable Zero halogen fire retardant (ZHFR/HFFR), smoke free, non toxic, non corrosive, 1100 volt grade with multi stranded copper conductor drawn through and incuding med grade, ISI marked incl ERW mettalic rigid steel conduit not less than 20 mm dia with accessories concealed on wall/ceiling and incuding provision of 1.5 Sqmm single core PVC insulated , unsheathed cable ZHFR, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, incl making good the disturbed surfaces and painted as per existing for for one light/fan point controlled by one switch complete all as per specified and directed. |
| 7 | Supply and fixing LED light fitting 2x16 Watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed. |
| 8 | Supply and fixing Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V, CMRI certified complete all as specied and directed. |
| 9 | Supply and fixing Aluminum Flame proof Exhaust Fan 12 Inch 1440 RPM Single Phase with louver.Complete all as specified and directed. |
| 10 | Supply and fixing LED flood light 100 watt 230 VAC outdoor type with thermal management inmultiple optics and equipped with IP66protection, with impact and corrosion resistantcomplete with driver and lamp.All as specified and directed. |
| 11 | Supply and fix sheet metal enclosures distribution board SPN 4 ways double door , IP 43 protection, 240 volts, with shrouded neutral bar & insulated bus bar (200 Amps) and earth link, suitable for MCBs/RCBOs as incomer and out going complete dully grouted on the wall (flush) and making good the disturbed surface matchig with existing surface all as specified and directed. |
| 12 | Supply and Fix MCB 32/ 40 Amp, 415 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed. |
| 13 | Supply and fix in repair MCB 6 to 40 Amp, 230 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified. |
| 14 | M&L for earthing complete with Galvanised steel earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of earth plate not less than 1.5 Mtrs deep below normal ground level, connected to GI wire 4 mm Dia by means of brazing and connected to earthing test point / distribution board/equipments or any other indicated situation by means of brazing all as shown in electrical plate No.3 of SSR Part I (2009) and testing on completion including necessary excavation and earth work in any type of soil, returning filling, removing of soil. GI medium grade pipe 20 mm dia 1.5 mtr long with funnel wire mesh as watering pipe, and GI medium grade pipe 32mm dia as earth lead protection pipe.Earth pit chamber made of PCC 1:2:4 type B1 using 20mm graded stone aggregate including 40mm thick chamber cover made of 1:2:4 type B1 using 20mm graded stone aggregate and reinforced with 8mm dia TMT bars at 100 c/c on both ways precast chamber cover with lifting handle 16mm dia round bars including chorcoal and common salt in alternate layer of 15cm thick covering all faces of earth electrode plate, complete all as specified and directed.(Note :- (i) The rates quoted for the complete earthing shall deemed to include the cost of GI wire 4.00 mm dia and GI medium grade protection pipe upto 7.5 Mtrs.(ii) GI earth strip and GI medium grade protection pipe beyond 7.5 Mtrs length shall be measured and paid separately.(iii) Fresh red soil required to be re-filled and existing calcium carbonate skeleton mixed soil to be removed from site. |
| 15 | Supply and laying double wall corrugated pipe (DWC) conforming to IS 19430 Part - I of size 110 mm outer dia and 95 mm inner dia complete all as specified and as directed. |
| 16 | Supply, laying, jointing and commissioning in replacment LT underground cables XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts, grade 3.5 core, cross sectional area 70 sq. mm with all fighting lugs, nuts and bolt etc. all as specified and as directed. |
| 17 | M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron earth strip 32x6mm (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm bore, and watering pipe 20mm bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip/wire and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. Please Enable Macros to View BoQ information |
| 18 | M&L for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron earth strip 32x6mm (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm bore, and watering pipe 20mm bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete all as specified and as directed.Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm.(ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit.(iii) Rate shall include GI strip/wire and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately.(iv) Earth resistance should be less than 3 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 27, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 27 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender