Housing Urban and Rular Development Government Departments Closing in 15 days TDR #57767402

Tender For Supply Installation Testing and Commissioning of Fire Detection System At Salt Lake S.D Hospital, Salt Lake.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
23.20 Lakhs
Estimated cost
Bid Submission
27 Oct 2026
15 days left
EMD
46400
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Fire Detection System At Salt Lake S.D Hospital, Salt Lake.

BOQ

Name of Work:- SITC of Fire Detection system at Salt Lake S.D Hospital, Salt Lake.
Sl. No. Item Description
1Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Multisensor Detector (VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
2Supply, Installation, Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
3Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
4Supply, Installation, Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS / UL /ERTL/ LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel)
5Supply, Installation, Testing & Commissioning of Addressable Monitor Modules ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel)
6Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS / UL /ERTL/ LPCB / FM approved) that is built up with potential free change over contact. Each of the relay contact should be Fail/Safe programmable and each contact to operate in three condition viz. NO FIRE CONDITION/FIRE CONDITION/LOOP POWER FAILURE CONDITION complete in single or multiple housing with degree of protection IP-54.(Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel)
7Supplying, Installation, Testing and Commissioning of LED type Response Indicator ( VDS / UL /ERTL/ LPCB / FM approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel )
8Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make : Finolex/ Gloster/ RR Kable/ Polycab/ KEI ) through S & F of 20 mm dia PVC 'FR' type Rigid Conduit pipe / 19 mm dia polythene pipe with necessary arrangement as per G.S. (Precision / Polycab )(Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall.
9Supply, Installation, Testing & Commisioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel ( VDS / UL /ERTL/ LPCB / FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capcity twice.
10The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required.
11The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software.(Approved Make : Cerberus Pro / Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo / Morley / Eaton / GST/ Ravel/ Notofire)
12(Rate should be quotated including all taxes and duties, GST and considering the value of less cost materials.) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57767402
AUTHORITY Government Departments
TENDER VALUE 23.20 Lakhs
LAST DATE 27-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Supply Installation Testing and Commissioning of Fire Detection System At Salt Lake S.D Hospital, Salt Lake.
Basic Detail
Tender No WBPWD/EE/KNHED/e-NIQ-38/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 29 Sep 2026
Submission Date 27 Oct 2026
Open Date 29 Oct 2026
Finance
Tender Value 23.20 Lakhs
Tender Fee Ref. Documents
EMD 46400
Exemption Not Available
Document List
2911.pdf
BOQ_5169341.xls
f67c654c-2c71-4c67-81c6-238f98ddffac.html
suspension.pdf
Tendernotice_1 (44).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Oct 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

xls

BOQ_5169341.xls

html

f67c654c-2c71-4c67-81c6-238f98ddffac.html

pdf

suspension.pdf

pdf

Tendernotice_1 (44).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders