Tender For Special Repairs To Bldg No P-983 (Or Living Line) Against (Job No.81 Sa/Btd/Sr (Bldg)-32/2026-27) Under Ge South At Bathinda Mil Stn
Tender Overview
Project Description
Tender For Special Repairs To Bldg No P-983 (Or Living Line) Against (Job No.81 Sa/Btd/Sr (Bldg)-32/2026-27) Under Ge South At Bathinda Mil Stn
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Oct-2026 | Corrigendum 1 | Other | 27-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkats or frames with shutters (without taking off shutters from the frames) area not exc 1.5 Sqm each as doors, windows and ventilators and removal from site complete all as specified and as directed by Engineer-in-charge |
| 2 | Taking down chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5 sqm but not exc 4 Sqm each each as doors, windows and ventilators and removal from site complete all as specified and as directed by Engineer-in-charge . |
| 3 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat of Size 45mm x 70 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge. |
| 4 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 30 mm thick , size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long handle complete all specified and directed by Engineer -in-charge. |
| 5 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 100 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge. |
| 6 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Door Frame / Chowkhat with double rebate of Size 65mm x 125 mm comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) fabricated with miter joints after applying PVC Solvant cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg /cum and screw withdrawl strength of 2200 N (face ) & 1100 N (Edge) minimum Compressive strength of 58 N /sqmm modulus of elasticity 900 N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retaident and fixed in position with and including MS hold Fast lugs / SS Dash Fastner of required dia and length with and including Supply and Fixing (03 Nos Per Frame ) 100 mm long SS Butt Hinges complete all as specified and as directed by Engineer-in- charge. |
| 7 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) Solid Plain flush door shutter of 35 mm thick , size comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long handle complete all specified and directed by Engineer -in-charge. |
| 8 | Supply & Fixing Factory made single extruded WPC ( Wood Polymer Composite ) glazed and skeleton shutters of 35mm size open rebated and prepared to receive guage etc (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc comprising of virgin polymer of K value 58-60 (suspension grade ), Calcium Carbonate and nautral fibers ( Wood Powder / Rice husk / Wheat husk ) and non toxic additives (maximum toxcity index of 12 for 100 gms ) having minimum density of 650 kg /cum and screw withdrawl strength of 1800 N (face ) & 900 N (Edge) minimum Compressive strength of 50 N /sqmm modulus of elasticity 850N/Sqmm and resisitence to spread of flame of class A category with property of being termite / borer proof , water moisture proof and fire retardant and with and including Supply & Fixing of 02 Nos (per Leaf) SS 150mm long Tower Bolt, Supply & Fixing of 02 Nos (per door) SS 300mm long Sliding Bolt with and including Supply & Fixing of 02 Nos (per Leaf) Stainless Steel 150mm long handle complete all specified and directed by Engineer -in-charge. |
| 9 | Material and labour Cup Board Shutter, shelves made out of WPC board 18/19mm thick, density over 600 kg/Cum, shelves fixed with SS bracket/cleats as required and including dismantling of boarding any description (wooden/PVC/Gypsum board etc) fixed in any position complete all as specified and as directed Note : Accessories such as soft close hinges and handle shall be measured and paid separately as supply only |
| 10 | Supply and fixing 150mm long stainless steel handle fabricated type complete all as specified and as directed by Engineer-in-charge |
| 11 | Supply and fixing 200mm long stainless steel barrel tower bolts of extruded section and fixed complete all as specified and as directed by Engineer-in-charge |
| 12 | Supply and fixing 300mm long stainless steel sliding door bolts with hasp staple (bolt type) and fixing bolts with rolled or drawn stainless steel bolts complete all as specified and as directed by Engineer-in-charge |
| 13 | Supply and fixing Stainless Steel magnetic Catcher suitable for doors of cupboards / wardrobes fixed with steel screw complete all as specified and directed |
| 14 | Supply only soft closing/ self closing concealed hinges (cabinet hinge) full overlay opening angle 105 degree, made of stainless steel (SS 304 grade) nickel plated finish complete all as specified and as directed by Engineer-in-charge . |
| 15 | Supply only Handle 200mm size (SS 304 grade, nickel finish, fancy type complete all as specified and as directed by Engineer-in-charge |
| 16 | Supply and fixing 100 mm long Aluminium anodised hasp & staple, safety type, with hinge pin including bolt to hinge plate fixed with and including SS Screws complete all as specified and as directed by Engineer-in-charge |
| 17 | Material and labour Providing and fixing factory made uPVC white colour fixed window/ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners. Hardware : 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and Wire mesh and includes all other connected accessoriesNet opening will be measured for payment purpose.). Area not exceeding 1.00 Sqm each |
| 18 | Supply and fixing factory made uPVC white colour casement (Openable) window/ ventilator (Area not exceeding 1.00 sqm ) made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 19 | Supply and fixing factory made uPVC white colour casement (Openable) window/ ventilator (Area exceeding 1.00 sqm but not exceeding 2.00 sqm each) made of extruded profiles with wall thickness of 2.3mm ( + – 0.2mm). Window profile with hollow section with multi chamber, frame (60mm x 58mm), sash (60mm x 73mm), T profile (One vertical length in between two shutters) (60mm x 74mm), Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 +– 0.2mm thick, galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27.5mm). T profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall with 8 mm x 100mm long fasteners. Hardware: [casement handle made of zinc alloyed (white powder coated), But Hinges of'zinc alloyed (white powder coated), transmission gear made of mild steel with multi point locking system] and 5mm thick glazing with selected quality glass.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) |
| 20 | Supply & Fixing stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed with tinned tacks to stainless steel wire staple complete all as specified and as directed by Engineer-in-charge. |
| 21 | Supply & fixing for 4.0 mm thick, sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and as directed by Engineer-in- charge. |
| 22 | Supply & fixing 4.0 mm thick Figured glass pin head type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed by Engineer-in-charge |
| 23 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge |
| 24 | Supply & fixing Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified & directed by Engineer-in-charge. |
| 25 | Supply & fixing in repair Door closer hydraulically regulated,aluminium (die cast) body designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between61 to 80 kg and fixed complete all as specified and as directed by Engineer-in- charge. |
| 26 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc Laid dry or bedded and pointed in any mortar complete all as specified and as directed by Engineer-in-Charge. |
| 27 | Material and labour for Non Skid ceramic coloured tiles (Light shade ) 10 mm thick square or rectangular area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge by Engineer-in-Charge. |
| 28 | Material and labour for Non Skid ceramic coloured tiles (light shade) 10mm thick square or rectangular (same as floor tile, as per above item ), as in skirting, dado etc. set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and as directed by Engineer-in-Charge. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the permises etc. complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge. |
| 30 | Material and labour for Non Skid ceramic coloured tiles (Light shade ) 10 mm thick square or rectangular area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floor, set and jointed in neat cement slurry @ 3.00 Kg/ Per Sqm and pointed in white or coloured cement to match the shade of tile including necessary cutting as per site requirement, tiles laid over and including 15 mm thick bedding layer (screed) in cement mortar (1:6) complete all as specified and as directed by Engineer-in-charge by Engineer-in-Charge. |
| 31 | Material and labour for joint free glazed ceramic coloured tiles of approved quality in vertical surfaces 450mm x 300mm x 7mm / 600mm x 300mm x 7mm thick set jointed in neat cement slurry / paste and pointed in white or coloured cement to match the shade of tiles over and including 10mm thick backing coat in CM 1:4 complete all as specified and as directed by Engineer-in-charge |
| 32 | Material and labour 25mm thick cement concrete type B-0, 1:2:4 (12.5 mm graded stone aggregate) as in levelling course where as rerquired complete all as specified and as directed by Engineer-in-charge by Engineer-in-Charge. |
| 33 | Material and labour 18-20 mm thick Granite machine cut (table rubbed and polished) in steps / dado, riser, cooking plateform etc laid over cement screed and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone and rounding off / moulding to edges (half round) including grinding and polishing complete including 10mm thick backing coat in CM 1:4 and including demolition of stone/tiles complete all as specified and as directed by Engineer-in-charge |
| 34 | Material and labour 16-18mm thick approved shade green marble machine cut duly factory grinding and polishing (table rubbed and polished) as in steps, skirting / dado, riser, jambs, pillars, window cills, for counter sunk wash basin and like where directed laid over and including 15mm thick cement mortar (1:4) screed bed including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of marble including cutting as required including cleaning and extra polishing if required complete all as specified. |
| 35 | Supply and Fixing 20 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 20mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge. |
| 36 | Supply and Fixing 25 mm bore CPVC pipe SDR 11and plain CPVC SDR 11 fitting with all fitting and fixed to walls & ceilings or laid in floors, including taking down unservicable existing GI tubing of 20mm bore and fittings complete complete all as specified and as directed by Engineer-in-charge. |
| 37 | Supply and fixing in repair bib taps cost copper alloy with crutch or butterfly handle , screwed down , chromium plated screwed for iron pipe or brass ferrul for 15MM bore dia pipe complete all as specified and as directed by Engineer-in-charge |
| 38 | Supply and fixing in repairs 15mm bore swan neck Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed by Engineer-in-charge |
| 39 | Supply and fixing 15mm bore Stop valves, fancy type, chromium plated with long shank and cup cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 40 | Supply & fixing in repair chromium plated shower rose 125mm size, with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engineer-in-charge. |
| 41 | Supply and fixing in repair 15mm bore Stop valves, fancy type, chromium plated with long shank and cup (concealed type) cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed for iron pipe or for brass ferrule complete all as specified & directed by Engineer-in-charge. |
| 42 | Material and Labour in repair vitreous china wash down water closet pan wall hanging single piece (with and including flushing cistern EWC) 'P' trap, with and including white coloured closed pattern plastic seat cover, hand faucet , with and including mild steel chromium plated or aluminised hinging device complete all as specified and as directed by Engineer-in- charge. |
| 43 | Supply and fixing in repair concealed flushing cistern of PVC 8 litre capacity with dual flushing cistern, valveless syphonic action type with inlet/outlet, ball valve, float and including brackets and connection to pipe etc and incl Supply and fixing of all necessary accessories/installation kit and 'S' type drain pipe connection set for wall hung WC etc as recommanded by manufacturer for fixing packing and including Supply and fixing of actuator knob/flush plates and taking down existing cistern of any description / size complete all as specified. |
| 44 | Supply and fixing in repair vitreous China wash hand basin counter top of size 565 x 425 x 140 mm white including CP waste coupling complete all as specified and as directed by Engineer-in-charge |
| 45 | Supply and fixing in repair Vitreous China Urinals, half stall type white including 40mm waste coupling making connection and fixed in position complete all as specified and as directed by Engineer-in-charge |
| 46 | Supply and fixing Urinal spreader of PTMT any colour for fixing with 15mm dia pipe (minimum weight 60 gms). complete all as specified and as directed by Engineer-in-charge |
| 47 | Supply & fixing Hand shower (health faucet) ABS body mild steel chromium plated including 1.25 meter long 8mm dia flexible tube and including wall hook for 15mm bore pipe complete all as specified and as directed by Engineer-in-charge. |
| 48 | Supply and fixing in repair, water jet for EWC chromium plated traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixing in 32mm bore of trap complete all as specified and as directed |
| 49 | Supply and Fixing in repair Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe ir connections including necessary packing, union and cap and fixed in 32mm bore of trap complete all as specified and as directed by Engineer-in-charge. |
| 50 | Supply and fixing toilet paper holder of chromium plated with falt recessed type stainless steel\\"fixid to walls with chromium plated(cp) brass screw complete all as specified and as directed by Engineer-in-charge |
| 51 | Supply and fixing in repair PVC connection 15 mm size with PTMT nuts of length 600 mm of approved quality complete all as specified and as directed by Engineer-in-charge. |
| 52 | Supply & fixing in repair brass chromium plated tubular towel rail 20mm dia 'D' type, 600mm long between flanges fixed to plug , bracket with chromium plated brass screws complete all as specified and as directed by Engineer-in-charge by Engineer-in-Charge. |
| 53 | Supply and fixing chromium plated soap tray any type and fixed to plugs on wall with chromium plated brass screws complete all as specified and as directed by Engineer-in-charge |
| 54 | Supply and fixing 125mm dia grating with/without waste hole of PTMT including circular cutting on tiles etc complete all as specified and as directed by Engineer-in-charge |
| 55 | Supply and fixing looking mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and moulding/wooden fillets (cross sectional area exc 6 sqcm & n.exc 13 Sqcm) on top side around edges including necessary screws and cup washers and fixing to wall with suitable hanging/fixing arrangement of any size each exceeding 0.50 sqm complete all as specified and as directed by Engineer-in-charge |
| 56 | Supply and fixing in repairs corners glass shelf (25cm/30cm) chromium plated brass bracket & railing etc complete all as specified and as directed by Engineer-in-charge |
| 57 | Supply and fixing in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass self 12cm wide with chromium plated bracket guard and railing 60 cm long complete all as specified and as directed by Engineer-in-charge |
| 58 | Supply & Fixing Rotational moulded poly-ethylene three layer water storage tanks (cylinderical vertical with closed top) 1000 litres capacity,hoisted and fixed in position and including dismantling water tanks and removing to store all as specified and directed. |
| 59 | Supply and Fixing in repair Ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe of size 20 mm bore (minimum weight 20mm-210 gram) complete all as specified and as directed by Engineer-in- charge. |
| 60 | Supply and fix gun metal gate valve of 20 mm dia bore size (IS -778) Class 1 with iron wheel head, screwed inside, non-rising stem, complete all as specified and as directed by Engineer-in-charge . |
| 61 | Supply and fix gun metal gate valve of 25 mm dia bore size (IS -778) Class 1 with iron wheel head, screwed inside, non-rising stem, complete all as specified and as directed by Engineer-in-charge . |
| 62 | Supply and fixing stainless Steel curtain rod 25mm dia, wall thickness of pipe not less than 16 gauge and grade SS 304, including brackets and pair of decorated end knobs (finials), stop roller etc as per site requirement fixed to wall with fixing accessories, including taking down old existing curtain rods any type or condition complete all as specified and as directed |
| 63 | Supply and fixing peg set / coat hooks made of stainless steel complete all as specified and as directed by Engineer-in- charge. |
| 64 | Demolition of RCC of any description such as Kitchen chimney, shelves, OHT Tanks etc and in any position not other wise specifically provided for complete all as specified and as directed by Engineer-in-charge by Engineer in Charge ( reinforcement cut as required to facilitate demolition) |
| 65 | Material and labour Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 metre mean radius built in Cement Mortar 1:6 and including demolition of brick work or stone masonary built in cement mortar or cement lime mortar complete all as specified and as directed by Engineer-in-Charge . |
| 66 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed by Engineer-in-charge. |
| 67 | Material and Labour for plastering 10mm thick with ready mix cement plaster material on internal surfaces of brick wall or concrete surfaces, finished even and fair complete all as specified and as directed |
| 68 | Material and Labour plastering 15mm thick with ready mix cement plaster material on external surfaces of brick wall/chajja/fins or concrete surfaces, finished even and fair complete all as specified and as directed by Engineer-in-charge |
| 69 | Material and Labour plastering 5mm thick with ready mix cement plaster material on concrete surfaces of ceiling finishing fair and even complete all as specified and as directed by Engineer-in-charge |
| 70 | Material and Labour for pre-cast Cement Concrete (1:2:4) Type- B-1 , using 20mm graded stone aggregate as in manhole cover, placed in position, including chamfers weatherings, throating etc and setting in mortar complete with joints to match complete all as specified and as directed by Engineer-in-charge |
| 71 | Material and labour for mild steel TMT bars 10mm dia and over cut to length bent to shape, required including cranking, bending spirally for hoping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge. (NOTE : Weight of binding wire shall not be considered for measurement and payment purpose.) |
| 72 | Material and Labour for Cutting holes in brick walls built in cement mortar exceeding half brick but not exceeding one brick for inserting hold fast and making good dismantled portion in CM 1:3 or Cement concrete 1 : 2 : 4 , type B1 as required, Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall complete all as specified and as directed by Engineer-in- charge. |
| 73 | Material and Labour for Cement Concrete 1 : 2 : 4 Type B-1 , using 20 mm graded stone aggregates as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating,complete all as specified and as directed by Engineer-in- charge. |
| 74 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in- charge. |
| 75 | Demolition and breaking up drain pipes SGSW,AC or reinforced concrete pipe set in cement mortar up to and including 150 mm bore pipes all as specified and directed by Engineer-in-Charge. |
| 76 | Material and labour for PCC (1:3:6) type C-2 using 40 mm graded stone aggregates as in concrete bed of SGSW drain pipes of 150 mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed by Engineer-in-charge. Note :- (i) Thickness of concrete bed below the barrel of pipe shall be 10 cm. (ii) Width of concrete bed shall be outer diameter of drain pipes (not of sockets / collar) plus 30cm. |
| 77 | Material and labour for 150 mm dia (internal) DWCPE pipes laid in trenches & jointed complete all as specified |
| 78 | Material and Labour for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for Internal dia of pipe in 150 mm complete all as specified and as directed by Engineer-in-charge. |
| 79 | Returning and filling including spreading, leveling watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed by Engineer-in-charge. |
| 80 | Removing excavated material (Soils ) not exceeding 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge. |
| 81 | Material and Labour for precast cement concrete louvers and jallies 35mm thick , 1:2:4 Type B-0 using12.5 mm graded stone aggregates, set in cement mortar 1:4 (measured solid) including all mouldings complete all as specified and as directed by Engineer-in- charge. |
| 82 | Supply and fixing for 0.56 mm thick Plain Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth is fixed) |
| 83 | Dismantling and disconnecting of existing CI soil vent pipe 100 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-charge . |
| 84 | Dismantling and disconnecting of existing CI soil vent pipe 75 mm bore fixed to wall,laid in trenches incl all fittings & accessories complete all as specified and as directed by Engineer-in-charge . |
| 85 | Supply and fixing 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls and fixing with clamps complete all as specified and as directed by Engineer-in-charge |
| 86 | Supply and fixing 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to walls and fixing with clamps complete all as specified and as directed by Engineer-in-charge |
| 87 | Supply and fixing 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint, laid in trenches or in floor complete all as specified |
| 88 | Supply and fixing 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joint, laid in trenches or in floor complete all as specified and as directed by Engineer-in-charge |
| 89 | Supply and fixing in repair 110mm bore, PVC (SWR) bends any radius complete all as specified and as directed by Engineer-in-charge |
| 90 | Supply and fixing in repairs 110 mm bore, PVC (SWR) branch piece, single (singel Y) equal or unequal as complete all as specified and as directed by Engineer-in-charge |
| 91 | Supply and fixing in repairs 110 mm bore, PVC (SWR) junction single (single T) equal or unequal as complete all as specified and as directed by Engineer-in-charge |
| 92 | Supply and fixing in repairs 75 bore, PVC (SWR) bends any radius as complete all as specified and as directed by Engineer-in-charge |
| 93 | Supply and fixing in repairs 110mm dia bore PVC (SWR) P' trap with grating including jointing with solvent complete all as specified and as directed by Engineer-in-charge |
| 94 | Supply and fixing 75mm outlet dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed by Engineer-in-charge |
| 95 | Supply & fixing 110 mm bore of pipe PVC (SWR) type B ring fit pipes single socket in any length with Stack clamps as shown in BTD Drg No. 916 sheet 1/4 to 4/4 and BTD-917 sheet sheet 1/1 of stays to wall at a distance of 100-120mm away from walls complete all as specified and as directed by Engineer-in- charge including Taking down old AC eaves gutters and rain water pipes ( of any size and pattern) including all fittings, compete all as specified and as directed by Engineer - in-charge. |
| 96 | Supply and fixing for 100mm bore of pipe Stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays including bolts and nuts and securing ends of stay to wall or roof all as specified and directed |
| 97 | Demolition of cement concrete (unreinforced) of any description & in any position not otherwise specifically provided for ,complete all as specified and as directed by Engineer-in-charge . |
| 98 | Material and Labour for 75 mm thick PCC 1:3:6 , Type C-2 using 40 mm graded stone aggregate as in flooor, hard standing, plinth protection/path finishing the surface even and smooth without using extra cement including joints filled with sealing compound complete all as specified and as directed by Engineer-in- charge. |
| 99 | Material and labour for preparation of new plastered internal wall suraface and applying putty 1mm thickness over plastered surface to prepare the surface even and smooth including priming coat of interior primer and two coats of distempering with is quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltr of approved manufacture of reuquired shade and colour complete as per manufacture specification |
| 100 | Material and labour for complete removal of existing treatment on old plastered internal wall surface and applying putty 1mm thickness over plastered surface to prepare the surface even and smooth including priming coat of interior primer and two coats of distempering with is quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ltr of approved manufacture of required shade and colour complete as per manufacture specification |
| 101 | Material and labour for preparation fo new palstered wall surface and finshing wall with two coats of Acrylic smooth exterior paint of required shade : (applied @ 1.67 ltr / 10 sqm over and including priming coat of exterior primer applied @2.20 kg / 10Sqm complete all as specified and as directed by Engineer-in-charge |
| 102 | Material and labour for complete removal of existing treatment on old palstered wall ssuraface and finshing wall with two coats of Acrylic smooth exterior paint of required shade : (applied @ 1.67 ltr / sqm over and including priming coat of exterior primer applied @2.20 kg / 10Sqm complete all as specified and as directed by Engineer-in-charge |
| 103 | Material and labour for 1.5 mm thick wall care putty on wall surfaces to make the surface smooth complete all as specified and as directed by Engineer-in-charge |
| 104 | Material and labour for preparing newly plastered or unplastered surface of ceiling and applying three coats of white wash complete all as specified & directed by Engineer-in- charge. |
| 105 | Material and labour for preparing old plastered or unplastered surface of ceiling and applying two coats of white wash complete all as specified & directed by Engineer-in- charge. |
| 106 | Material and labour for preparation of new steel and iron surfaces of any description not otherwise described over 10cm in width or girth and applying two coats of synthetic enamel paint complete all as specified & directed by Engineer-in- charge. |
| 107 | Removal of existing PCC/Brick bat Coba/Mud phuska/ APP membrane from the roof stacking the reuseable material and disposal of unserviceable rubbish out side the campus as direction by Engineer-in-Charge but outside in 3 Km complete all as specified & directed by Engineer-in- charge. |
| 108 | Material and labour for repair of surface with GP-2 (General Purpose Grout) or repair mortar as and where required as per site condition/manufactures instruction upto 15mm thick and including cracks shall be repaired with cement admixed with polymers as per manufactures instructions complete all as specified |
| 109 | Material and labour for cleaning the surface or any loose dust, and dirt or slurry by means of wire brush, dust removing brush etc. Cracks shall be repaired with cement admixed with polymer as per manufacturers instructions. After preparation of surface the following treatment shall be provided complete all as specified and as directed by Engineer-in-charge and surface treated with PU epoxy primer to seal the pores and enhance the adhesive of the coating, supply and applying single component waterproofing liquid membrane based on pure, polyurethane resin cold applied with spray, applied membrane with an elongation of 650% +50 and tensile strength not less than 2Mpa. No leakage up to five bars water pressure. Shore hardness >70 shall be 2.00mm (overall) DFT (Dry Film Thickness), in five layers (each layer minimum 750 micron) or as per manufacturers instructions so as to achieve thickness not less than 2.00mm DFT\\" PU membrane shall be UV resistant with SRI (Sun reflective Index) of 98. complete all as specified & directed by Engineer-in- charge. |
| 110 | Material for providing PCC coving/gola along vertical parapets of size 75mm x 75mm with cement concrete, 1:2:4 type B1 (using 20mm crushed stone aggregate) and mixing liquid WPC in mortar @ as per manufacture instruction per bag of cement of 50 Kg complete. (WPC will be measured and paid separately as supply only under appropriate item of schedule 'A' of BOQ |
| 111 | Material and Labour PCC padding in 1:2:4 Type B-1 (using 20mm graded stone aggregates) as in roof slab finishing the surface even and fair and maintain roof slope during the execution of work including Liquid water proofing compound complete all as specified and as directed by Engineer-in-charge . Liquid Water proofing compound shall be measured and paid separetly as supply only under appropriate item of Schedule 'A' BoQ. |
| 112 | Material and labour for cement slurry @ 1.2 kg /sqm spreading with bristle brush and rendering 15 mm (average thickness) in cement mortar 1:3 finished even and fair mixing with Liquid water proof compound 200ml per 50 kg cement bag on roof surface complete all as specified and as directed by Engineer-in-Charge. Note :- Liquid water proof compound shall be measured and paid separately. |
| 113 | Supply only liquid water proofing compound complete all as specified and as directed by Engineer-in-charge by Engineer-in- charge. |
| 114 | Material and Labour for Cleaning of existing reinforcement bars in Roof, ceiling, Chajja, Fascia, Fins, Drops and similar items with wire brush / rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and with and including applying alkline rust converting primer on the existing rebar and allowing it to react with rust for 06 Hrs and from a corrosion resistant , insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturer's instructions, complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge.Note:- Mode of measurement per sqm of breaking area of concrete only. |
| 115 | Material and Labour for Rebuilding the section of structural damaged RCC/PCC elements of Roof, Ceiling, Chajja, Fascia, Fins, Drops repair to spalling concrete to its original size and shape in layers of 10 mm average thickness in 1st layer by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79 complete all as per manufacturer's instructions , complete all as specified and as directed by Engineer-in-charge. |
| 116 | Material and labour for 75 mm thick cement concrete 1:4:8 , type D-2 using 40 mm graded stone aggregate as in sub base of floor. finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. |
| 117 | Material nad labour for 25mm thick Sand filling under interlocking tiles including watering and consolidation complete as specified and as directed by Engineer-in-charge.Note:- Sand shall be approved by GE before incorporation in the work |
| 118 | Material and labour for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade colour and pattern as approved by GE with grey cement and pigment complete all as specified and as directed by the Engineer-in-Charge. |
| 119 | Taking down carefully copper /aluminium point wiring (light, fan, socket or power point ) complete including fitting such as hylem , sheet switches, ceiling rose, pendent holder , sockets, fan regulator , bell push, Electronic bell , sunken box except concealed conduit etc. complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge. Notes:(i) The weight of aluminium scrap , copper scrap and Iron scrap shall be ascertained by BOO as ordered by GE and same duly countersinged by GE shall be enclosed with final Bill. (ii) The rate of cutting chases (as required) and making good surfaces to match with adjoining surface shall be measured and paid seperately under serial item no. 120.00, 121.00, 122.00, 123.00, 124.00 & 125.00 of BoQ. |
| 120 | Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia in medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall complete and including modular metal flush boxes not less than 1.6mm thick alongwith modular cover plate with frame of any size for mounting of any type modular switches/sockets/bell switch/fan regulator and brass screws, cup washers etc complete making good the distributed surfaces completely matched and finished with existing surfaces including painting of walls etc complete all as specified and as directed by Engineer-in-charge |
| 121 | All as per srl item item no.120.00(here-in-before) but one 3 pin socket outlet 6 amp on same board point, complete all as specified and as directed by Engineer-in-charge . |
| 122 | All as per srl item item no.120.00(here-in-before) but one 3 pin socket outlet 6 amp on the independent board point, complete all as specified and as directed by Engineer-in-charge . |
| 123 | All as per srl item item no.120.00(here-in-before) but One light point controlledd by two way switch, complete all as specified and as directed by Engineer-in-charge . |
| 124 | All as per srl item item no.120.00(here-in-before) but for 15/16 Amp socket outlet by using 2.5 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 2.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc, complete all as specified and as directed by Engineer-in-charge . |
| 125 | All as per srl item item no.120.00 (here-in-before) but for 15/16 Amp Geysers/ AC let by using 4.0 Sqmm PVC insulated unsheathed copper conductor cable FR-LSH multi strand on independent board including provn of 4.0 Sqmm unsheathed, multi stranded copper conductor cable FR-LSH continues as earth wire connected to earth dolly etc, complete all as specified and as directed by Engineer-in-charge . |
| 126 | Supply and fixing Modular Switch one way 6A/10A 1 module single pole complete all as specified and as directed by Engineer-in-charge . |
| 127 | Supply and fixing Modular Switch one way 16A 1 module single pole complete all as specified and as directed by Engineer-in-charge . |
| 128 | Supply and fixing socket outlet modular type, multipurpose,2/3 pin,single pole one way ,6amp two module, complete all as specified and as directed by Engineer-in-charge |
| 129 | Supply and fixing socket outlet modular type, multipurpose,2/3 pin,single pole one way ,6/16 amp two module, 230 volt, complete all as specified and as directed by Engineer-in-charge |
| 130 | Supply and fixing of Modular switch 2 way 6A, 1 module single pole complete all as specified and as directed by Engineer-in-charge |
| 131 | Supply and fixing fan regulator, modular type, 5 step, 120W, high speed, two module complete all as specified and as directed by Engineer-in-charge. |
| 132 | Supply and fixing ceiling rose surface bake lite with 3 terminlas complete all as specified and as directed by Engineer-in-charge |
| 133 | Supply and fixing Lamp holder PVC/polycarbonate type with back plate complete all as specified and as directed by Engineer-in-charge |
| 134 | Supply and fixing of 9 watt LED Bulb suitable for B-22 type holder complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge |
| 135 | Supply and fixing of SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cutting & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and as directed by Engineer-in-charge |
| 136 | Supply and Fixing replacement of INVERTER LED Tube Light Fittings 1200mm, 25 W, 6500K higher energy saving , Decorative ultra slim square profile LED lighting fixture with extruded aluminum housing, environmental friendly, energy efficient ready to use pack and comprising of batten with all accessories internally prewired complete all as per manufacturer's instructions, and with and including connecting up with twin core twisted copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and as directed by engineer-in-charge. |
| 137 | Supply and fixing in repalcement of LED tube light fitting Mirror type with high output diffuser 2 feet 10 /12 Watt, 230 Volts, decorative type environmental friendly, energy efficient ready to use pack and comprising of batten with all accessories internally prewired and connecting up with twin core copper cable of size 23/.00076 complete all as specified and as directed by Engineer-in-charge |
| 138 | Supply and Fixing decorative wall light fixture made of stainless steel suitable for retrofit 9W LED Lamp (base B-22) complete with PC diffusor & including one 9W LED lamp (base B-22), 6500K, not less than 90 lumen/watt efficacy ,complete all as per manufacturer's instructions and connection with flexible twin core copper cable of size 23/.00076, wall mounted bracket including making connection complete all as specified and as directed by Engineer-in- charge. |
| 139 | Supply and fixing Building Security light LED Type of capacity 35W comprising with pressure die cast aluminum housing IP 66 protection with all accessories internally prewired complete all as per manufacturer's instructions with and including bracket made of 40mm dia GI Light grade pipe of 1.20mtr long bent to shape fixed with suitable MS clamps, bolts, nuts and washers duly painted with aluminum paint and including connection up with twin core twisted copper conductor cable of suitable size with complete all as specified and as directed by engineer-in-charge. |
| 140 | Supply, installation, testing and commissioning of 1200 mm sweep, Max-30 watt BEE 5 rated, ceiling fan with Brush less Direct Current (BLDC) Motor (Copper wound), Class of insulation : B, 3 nos. aerodynamic Aluminium blades, Power Factor not less then 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (As per IS: 374-2019 or latest amendments), THD less than 10% Double ball bearing, Stranded white colour, remote for speed control 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope and all remaining accessories including safety pin, nut bolts, washers, temperature rise = 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for voltage range 120 to 285 Volts, 50 Hz, single phase AC Supply, including taking down old and deposit to E/M store complete all as specified and as directed by Engineer-in-charge |
| 141 | Supply and fixing of steel body exhaust fan of sweep 380 mm heavy duty AC single phase, 230 Volts along with metallic louver complete including cutting of wall, making of proper hole sufficient fix exhaust fan and smoothing of the surface before fixing of exhaust including taking down existing unserviceable ceiling fan and deposit to E/M store all as directed and as specified |
| 142 | Supply and fixing in replacement of Post Top Lantern Type LED 25 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistance complete with driver and lamp as per manufacturer's instructions complete, fixed on with and including GI pipe light grade 40mm of suitable length as directed by Engineer-in-charge and embeded in PCC 1:2:4, Type-B1, using 20mm graded stone aggregates, with and including electrical connection with 1.5 mtr long with twin core round copper conductor cable of suitable size and testing complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge |
| 143 | Material and labour Three phase sub main wiring with 10.0 Sq mm nominal cross sectional area, Four single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 10.0 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 32 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finished with existing surface are included in the rate complete all as specified and as directed by Engineer-in-charge Note :-(i) 4 run of 10.0 Sqmm main cable, one run of 10.0 Sqmm earth wire and one run length of PVC conduit of size 32mm shall be considered as one running length(ii) The wiring shall be done in proper colour coding using Red, Yellow, Blue for phases, Black for neutral and Green for earth |
| 144 | Material and labour sub main wiring with 06 Sq mm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sq mm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to matched and finished with existing surface are included in the rate complete all as specified and as directed by Engineer-in-charge Note :-(i) 2 run of 6.0 Sqmm main cable, one run of 6.0 Sqmm earth wire and one run length of PVC conduit of size 25mm shall be considered as one running length(ii) The wiring shall be done in proper colour coding using Red, Yellow, Blue for phases, Black for neutral and Green for earth |
| 145 | Supply and fixing in replacement sheet metal enclouser DB (made out of CRCA sheet not less than 1.2mm thick) SPN, 12 Way 230V AC, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43 & IK09 suitable for mounting MCB/Isolator, conforming to IS-8623, BS-5484 dust and vermin proof, including making good disturbed surfaces of walls as necessaty, complete all as specified and as directed by Engineer-in-charge by Engineer-in-charge.Note: MCB & MCCB shall be measured and paid seperately in respective items of Schedule'A' BoQ |
| 146 | Supply and Fixing in replacement Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB V TPN 4 way, 415 V AC with 200 Amps rated bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ. |
| 147 | Supply and Fixing in repairs Sheet metal enclousers made out of CRCA mild steel sheet not less than 1.2mm thick,, IP-54 protection, flush mounted for metal door, powder coated DB V TPN 4 way, 415 V AC with 200 Amps rated bus bar, Double door, dust and vermin proof suitable for incorporation of Incoming MCCB and outgoing MCB SP/TP and earth & neutral bus bar etc complete all as specified and as directed by Engineer-in- charge.Note: MCB/ Isolators shall be measured and paid seperately under appropriate item of BOQ. |
| 148 | Supply and fixing in replacement of SP MCB 6-32 Amp,240 Volt 10KA 'C' series complete all as specified and as directed by Engineer-in-charge |
| 149 | Supply and fixing in replacement of SPN MCB 40-63 Amp,240 Volt 10KA 'C' series complete all as specified and as directed by Engineer-in-charge |
| 150 | Supply and fixing MCB 'C' curve suitable for 415 volts AC supply, 100 Amps, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA, fixing in DB/panel complete all as specified and as directed by Engineer-in-charge |
| 151 | Supply and fixing MCB 'C' curve suitable for 415 volts AC supply, 100 Amps, TP with over load and short circuit protection and rupturing capacity not less than 10 KA, alongwith suitable Sheet Metal enclosure power coated 415 Volts complete all as specified and as directed by Engineer-in-charge |
| 152 | Supply and fixing in replacement of MCCB 160 Amp, 4 pole, 415 volt, ISI marked, short circuit breaking capacity not less than 35/36KA, thermal magnetic trip, setting 80-100%, Icu-100% Ics conforming to IEC-947, IS-13947, thimbles, nuts, bolts, washers etc. complete all as specified and as directed by Engineer-in-charge |
| 153 | Material and Labour for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia light grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and as directed by Engineer-in-charge . (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 154 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 70 Sqmm x 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 155 | Supply and spread river sand 8 cm thick to required width at bottom and 15cm thick on top for cable cushioning (total thickness of sand cushion will be measured after hand punning and shall be not less than 18 cm thick in layer) all as specified and directed |
| 156 | Supply and laying un-reinforced precast concrete cable cover, class LV, type-1, Flat ,size 250mmX150mmX40mm, ISI marked laid flat across the cable length all as per specification and directed by engr-in-charge. |
| 157 | Supply installation, testing and commissoing of of Air cooled Heat Pump delivering actual capacity as per the following parameters. Heat pump shall be rated at Nominal Input Power -2.22KW with Output Heating capacity - 8 KW, Electrical Backup - 12 KW having Inbuilt Tank capacity - 455 litres having glass lining. Water Temp in efficiency mode using compressor should be 65 degree C. Heat pump should have all the safety protections like high/low voltage, high temperature, refrigeratnt leak, compressor overheting protection with operational noise level not more than 60 dbA. Heat pump should have a user freindly control panel to set the desired temperature showcasing the actual temp also with flexiblity of installing the same 15-30m away from the heat pumps complete. Including 01 x No Pressure pump with SS304 horizontal Hydropneumatic system, comprising of 1 no. electrical driven pump of 1 LPS to a head to 30 meter with all accessories coupled to motor suitable for operation on 400/440 volts, 1/3 phase 2900 RPM. including with motor with 24 Liters of pressure vessel complete with all conection of pipe line in/out, PCC work for foundation, and other retrofit work complete with all respect for smooth working of heat pump.The following specifiction must be included as mentioned below:-Power supply - 415 voltswater production - 142 Ltr/hrs or as per standardRefrigerant - R 134 APressure loss - 36 KPaMax operating current - 10.5 Ampwater connection pipe - 1\\"Water Temp in efficiency mode - 65 °COperation Temperature Range -37-75 °C Unit Operation Noise - 54 dB (A)Air Outlet Noise - 58 dB (A) |
| 158 | Hot Water Storage Tank 455 Ltr should be consisting of S.S 304 cylindrical shape clarifier tank. (Inlet temperature of hot water storage tank 60-85 deg.C) stainless Steel inner tank to be designed/ suitable for pressure upto 10 Kg/ Sq. cm (minimum Th. 0.63 mm) and tested and coated with Enamel Glass coating and Anode rod to control scaling. Tank shall be provided inlet/outlet, pressure release connection arrangements. SS tank to be designed/ suitable for working pressure of 6 Kg/ Sq. cm and above, pressure relief valves. pressure gauge at outlet with isolation cock, Digital thermometer at the centre of the Tank with, ball Valve, safety valve, check valve etc. The complete system to be tested to a pressure of 10 Kg/cm2 complete in all respects including temperature indicators, thermostat. Also Attached with following heating elements and its connection with the thermostat for auto cut off and other required accessories. Tank shall be insulated with 100 mm thick crown 150 grade & 50 mm or more thick rock wool pads of approved quality and cladded with 20 SWG powder coated M.S. Sheet cladding. Insulated Storage Hot Water Tank for heat pump should becomprising with the following points:-Capacity-455 LPDType Non-PressurizedConfiguration HorizontalInner Container- SS304Outer Shell Pre-coated Steel/AluminumWelding of inner Tank M IG we Id in gInsulation - PuffThickness -50 mm |
| 159 | Hot Water Recirculation Pumps in Heat pump and tank Providing, suitable complete horizontal/ vertical multistage centrifugal pumping set having stainlesssteel (SS304) impellers & shaft and single mechanical seal with pumps suitable for 415Volts 3 Phase 50 cycles A.C Supply complete with all standard accessories including, M.S.channel, base plate complete with vibration isolators, isolating valve onsuction anddischarge, non returnvalve on discharge, pressure gauges with stop cock and dial type thermometer on suction or discharge. (suitable for hot water temperature up to 85 deg C.) The pump 2 No (1 working+1stand by)complete with Control Unit Panel for automatic Cold & Hot water circulation, manifolds, as per the approval complete with base frame, necessary foundation as per requirement.No of Pump 2 (1W+1S)Flow 1000 LPH PerPump Head 15 MNote for item No 1 to 1.02:-1. The Replacement Guarantee 02 Year on complete and 05 Year for Compressor and stoarge tank. 2. All inter connection pipe line /valve between heat pump to storage tank will be scop of the firm withall respect.3. The PCC work and iron work for making foundation and structure for installtion of heat pump andstorage tank will be scope of the firm with all respect complete |
| 160 | Material and labour for Cutting existing GI tubing 40mm for alternations or additions for making new connection of size 25mm dia complete with all respect including retrofit work complete all as specified and as directed by Engineer-in-charge |
| 161 | Supply and Fixing 32 mm bore CPVC pipe SDR 11 with and including CPVC SDR 11 fittings and fixed to walls & ceilings or laid in floors, complete all as specified and as directed by Engineer-in-charge |
| 162 | Supply and fixing of CPVC Ball valve 32mm outer dia with handle head heavy duty screwed both ends for CPVC for union ISI marked complete all as specified and as directed by Engineer-in-charge |
| 163 | Supply and fixing of CPVC Ball valve 20mm outer dia with handle head heavy duty screwed both ends for CPVC for union ISI marked complete all as specified and as directed by Engineer-in-charge Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender